• Title/Summary/Keyword: stable current

Search Result 1,882, Processing Time 0.029 seconds

Operation evaluation of DAF pilot plant for water treatment process in Hoedong Reservoir (회동수원지의 정수처리 공정을 위한 DAF pilot plant 운영 성능평가)

  • Maeng, Minsoo;Shahi, Nirmal Kumar;Kim, Donghyeun;Shin, Gwyam;Dockko, Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.6
    • /
    • pp.463-471
    • /
    • 2020
  • A 1,000 ㎥/d DAF(dissolved air flotation) pilot plant was installed to evaluate the performance of the floating process using the Nakdong River. Efficiency of various DAF operations under different conditions, such as hydraulic loading rate, coagulant concentration was evaluated in the current research. The operation conditions were evaluated, based on the removal or turbidity, TOC(total organic carbon), THMFP(trihalomethane formation potential), Mn(manganese), and Al(aluminum). Also, particle size analysis of treated water by DAF was performed to examine the characteristics of particles existing in the treated water. The turbidity removal was higher than 90%, and it could be operated at 0.5 NTU or less, which is suitable for the drinking water quality standard. Turbidity, TOC, and THMFP resulted in stable water quality when replacing the coagulant from alum to PAC(poly aluminum chloride). A 100% removal of Chl-a was recorded during the summer period of the DAF operations. Mn removal was not as effective as where the removal did not satisfy the water quality standards for the majority of the operation period. Hydraulic loading of 10 m/h, and coagulant concentrations of 40 mg/L was determined to be the optimal operating conditions for turbidity and TOC removal. When the coagulant concentration increases, the Al concentration of the DAF treated water also increases, so coagulant injection control is required according to the raw water quality. Particle size distribution results indicated that particles larger than 25 ㎛ showed higher removal rates than smaller particles. The total particel count in the treated water was 2,214.7 counts/ml under the operation conditions of 10 m/h of hydraulic loading rate and coagulant concentrations of 60 mg/L.

Effects of strain on the optical and magnetic properties of Ce-doped ZnO

  • Xu, Zhenchao;Hou, Qingyu;Guo, Feng;Jia, Xiaofang;Li, Cong;Li, Wenling
    • Current Applied Physics
    • /
    • v.18 no.12
    • /
    • pp.1465-1472
    • /
    • 2018
  • The magnetic and optical properties of Ce-doped ZnO systems have been widely demonstrated, but the effects of different strains of Ce-doped ZnO systems remain unclear. To solve these problems, this study identified the effects of biaxial strain on the electronic structure, absorption spectrum, and magnetic properties of Ce-doped ZnO systems by using a generalized gradient approximation + U (GGA + U) method with plane wave pseudopotential. Under unstrained conditions, the formation energy decreased, the system became stable, and the doping process became easy with the increase in the distances between two Ce atoms. The band gap of the systems with different strains became narrower than that of undoped ZnO without strain, and the absorption spectra showed a red shift. The band gap narrowed, and the red shift became weak with the increase of compressive strain. By contrast, the band gap widened, and the red shift became significant with the increase of tensile strain. The red shift was significant when the tensile strain was 3%. The systems with -1%, 0%, and 1% strains were ferromagnetic. For the first time, the magnetic moment of the system with -1% strain was found to be the largest, and the system showed the greatest beneficial value for diluted magnetic semiconductors. The systems with -3%, -2%, 2%, and 3% strains were non-magnetic, and they had no value for diluted magnetic semiconductors. The ferromagnetism of the system with -1% strain was mainly caused by the hybrid coupling of Ce-4f, Ce-5d, and O-2p orbits. This finding was consistent with Zener's Ruderman-Kittel-Kasuya-Yosida theory. The results can serve as a reference for the design and preparation of new diluted magnetic semiconductors and optical functional materials.

Neuro-controller for Broadcast Lighting LED to Express xy Chromaticity Coordinates (xy 색도좌표 표현을 위한 방송 조명용 LED 신경망 제어기)

  • Park, Sung-Chan;Park, Jin-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.6
    • /
    • pp.706-713
    • /
    • 2020
  • To control the LED lighting for broadcasting, LED current control using tri-stimulus values is used for RGB LEDs. For the convenience of control, this control is approximated as a linear function or used as an appropriate value through trial and error. Also, it is not suitable for broadcast lighting because it does not use a diffuser plate applied for mixing sufficient light and color required for actual it. In this study, a neural network with excellent nonlinear function approximation is used as a control method for LED panels for broadcast lighting. We intend to implement an LED panels controller suitable for the desired chromaticity coordinates and dimming values of intensity. As a result of the performance evaluation, the errors of the xy chromaticity coordinates are mostly ±0.02 and the acceptable range of ANSI C78.377A was satisfied. The average errors of the xy chromaticity coordinate are xerror=0.0044 and yerror=0.0030, respectively, and we confirmed the superiority and stable performance of the proposed algorithm.

Analysis of Electrochemical Corrosion Resistance of Inconel 625 Thermal Spray Coated Fin Tube of Economizer (Inconel 625 용사코팅된 절탄기 핀튜브의 전기화학적 내식성 분석)

  • Park, Il-Cho;Han, Min-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.187-192
    • /
    • 2021
  • In this study, Inconel 625 was used as a thermal spray material to prevent dew point corrosion damage to the economizer tube, and sealing treatment was performed after applying the arc thermal spray coating technology. Various electrochemical experiments were conducted in the 0.5 wt% sulfuric acid solution to analyze the corrosion resistance of the thermal spray coating (TSC) layer. After the anodic polarization experiment, the degree of corrosion damage was determined through a scanning electron microscope and EDS component analysis. When measuring the open circuit potential, the effect of the sealing treatment was confirmed through stable potential formation of the TSC+sealing treatment (TSC+Sealing). As a result of the anodic polarization experiment, the passivation region was confirmed in TSC and TSC+Sealing, and corrosion resistance was improved as no corrosion damage was observed. In addition, the corrosion resistance of TSC+Sealing was the best when analyzing the corrosion potential and corrosion current density calculated by Tafel analysis.

Development of Augmented Reality Based Electronic Circuit Education System (증강현실 기반 전자회로 교육 시스템 개발)

  • Oh, DoBong;Shim, SeungHwan;Choi, HanGo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.9 no.12
    • /
    • pp.333-338
    • /
    • 2020
  • This paper proposes an augmented reality-based electronic circuit education system as a way for electronic circuit education, which is the basis of ICT convergence technology field. It consists of a hardware module that can identify the actual circuit and a mobile educational content that can check the current flow, input, output, and measured value by applying augmented reality technology. An experiment was conducted on image recognition, which is the main performance, for the purpose of stable operation of the system, and as the experimental method the recognition rate was measured by changing the distance between the hardware module and the mobile device to a certain interval. As a result of the experiment, the recognition rate was 100 percent at a distance of 25[Cm] or higher, and it was confirmed that the recognition rate decreased by 12% at a distance below 25[Cm], which can be said to be the effect of an error that results in image loss taken due to close distance. In the future, we plan to apply the education system presented in this paper to classes, which increases the efficiency of classes and improve students' interest and understanding of the subject.

Analysis of Failure and Electrical Fire for Bolt Induction Heating System Using FTA (FTA를 이용한 볼트 유도가열시스템의 고장 및 전기화재 분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Eom, Haneol;Kang, Moon-Soo;Jeong, Cheon-Kee
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.4
    • /
    • pp.12-19
    • /
    • 2021
  • This paper presents a safety assessment method for FTA-based induction heating systems; the failures and causes of electrical fire are first analyzed for each part and module qualitatively, and methods to manage high probabilities of failure and electrical fire are considered, thereby improving the reliability of the induction heating system. The cumulative importance value (ACC) of the minimal cut set is drawn by setting failure as the top event, and STACK and SMPS are observed to account for about 70% of the induction heating system failures. Thus, intensively managing the basic events contained in the minimal cut set of failures for STACK and SMPS is expected to provide effective and stable operation of the induction heating system. When electrical fire is set as the top event, the STACK percentage is 90%. Accordingly, the current IGBT is changed to a FET to increase the applied voltage and prevent induction heating system failure, and a heat sink plane is installed to prevent FET heating caused by switching, thereby preventing an electrical fire. By classifying the parts and modules of the induction heating system in detail and by applying FTA based on actual failure rates and relevant data, more practical and reasonable results may be expected. Hence, continuous research must be conducted to ensure safety when using induction heating systems.

A study on AC-powered LED driver IC (교류 구동 LED 드라이버 IC에 관한 연구)

  • Jeon, Eui-Seok;An, Ho-Myoung;Kim, Byungcheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.4
    • /
    • pp.275-283
    • /
    • 2021
  • In this study, a driver IC for an AC-powered LED that can be manufactured with a low voltage semiconductor process is designed and the performances of the driver IC were simulated. In order to manufacture a driver IC that operates directly at AC 220V, a semiconductor manufacturing process that satisfies a breakdown voltage of 500V or higher is required. A semiconductor manufacturing process for a high-voltage device requires a much higher manufacturing cost than a general semiconductor process for a low-voltage device. Therefore, the LED driver IC is designed in series so that it can be manufactured with semiconductor process technology that implements a low-voltage device. This makes it possible to divide and apply the voltage to each LED block even if the input voltage is high. The LED lighting circuit shows a power factor of 96% at 220V. In the pnp transistor circuit, a very high power factor of 99.7% can be obtained, and it shows a very stable operation regardless of the fluctuation of the input voltage.

Improvements of Unit System for nationwide expansion of Early Warning Service for Agrometeorological Disaster (농업기상재해 조기경보시스템의 전국 확대를 위한 단위 시스템의 개선)

  • Park, Joo Hueon;Shin, Yong Soon;Shim, Kyo-Moon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.4
    • /
    • pp.356-365
    • /
    • 2021
  • The nationwide expansion of the agricultural early warning service for agrometeorological disaster would require assessment of geographical and agricultural environmental characteristics by individual region. The development of an efficient computing environment would facilitate such services for the area of study region to deal with various crops and varieties for many farms. In particular, the design of the computing environment would have a considerable impact on the service quality of agriculture meteorology when the scale of computing environments increases for extended service areas. The objectives of this study were to derive the issues on the current computing environment under which services are provided by each region and to seek the solutions to these problems. The self-evaluation through experimental operation for about a year indicated that integration of the early warning service system distributed over different regions would reduce redundant computing procedures and ensure efficient storage and comprehensive management of data. This suggested that the early warning service for agrometeorological disaster would become more stable even when the service areas are to be expanded to the national scale. This would contribute to higher quality services for individual farmers.

Pre-Coronavirus Disease 2019 Pediatric Acute Appendicitis: Risk Factors Model and Diagnosis Modality in a Developing Low-Income Country

  • Salim, Jonathan;Agustina, Flora;Maker, Julian Johozua Roberth
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.1
    • /
    • pp.30-40
    • /
    • 2022
  • Purpose: Pediatric acute appendicitis has a stable incidence rate in Western countries with an annual change of -0.36%. However, a sharp increase was observed in the Asian region. The Indonesian Health Department reveals appendicitis as the fourth most infectious disease, with more than 64,000 patients annually. Hence, there is an urgent need to identify and evaluate the risk factors and diagnostic modalities for accurate diagnosis and early treatment. This study also clarifies the usage of pediatric appendicitis score (PAS) for children <5 years of age. Methods: The current study employed a cross-sectional design with purposive sampling through demographic and PAS questionnaires with ultrasound sonography (USG) results. The analysis was performed using the chi-square and Mann-Whitney tests and logistic regression. Results: This study included 21 qualified patients with an average age of 6.76±4.679 years, weighing 21.72±10.437 kg, and who had been hospitalized for 4.24±1.513 days in Siloam Teaching Hospital. Compared to the surgical gold standard, PAS and USG have moderate sensitivity and specificity. Bodyweight and stay duration were significant for appendicitis (p<0.05); however, all were confounders in the multivariate regression analysis. Incidentally, a risk prediction model was generated with an area under the curve of 72.73%, sensitivity of 100.0%, specificity of 54.5%, and a cut-off value of 151. Conclusion: PAS outperforms USG in the sensitivity of diagnosing appendicitis, whereas USG outperforms PAS in terms of specificity. This study demonstrates the use of PAS in children under 5 years old. Meanwhile, no risk factors were significant in multivariate pediatric acute appendicitis risk factors.

A Study on HVDC and BESS Application for High Penetration of Renewable Energy Sources (제주지역 재생에너지 수용을 위한 HVDC 및 BESS 활용에 관한 연구)

  • Kwak, Eun-Sup;Min, Jae-Hyun;Jung, Ho-Chul;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1339-1348
    • /
    • 2021
  • There are variety of reasons for renewable energy curtailment, including lack of transmission availability and grid system stability. In the Jeju island region, there are many cases in which the supply of electricity is already increased compared to the demand for electricity due to the increase of solar and wind power generation facilities, and accordingly, the number of curtailments for wind power generation is increasing. This research aims to find the direction of efficient reception of renewable energy and stable operation of the power system using HVDC(High Voltage Direct Current) and BESS(Battery Energy Storage System) facilities that are in charge of power supply in Jeju island. And the paper suggests a practical operation plan for optimal system operation, and the direction of system operation of the land power system due to the expansion of solar and wind power generation facilities in the future.