• Title/Summary/Keyword: stable core

Search Result 456, Processing Time 0.028 seconds

Electromagnetic properties of magnetic core materials used in the blocking filter for Power Line Communication (전력선 통신 Blocking filter용 자심 재료의 전자기적 특성)

  • Lee, H.Y.;Kim, H.S.;Huh, J.S.;An, Y.W.;Oh, Y.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.68-71
    • /
    • 2002
  • The electromagnetic properties and thermal behavior of ferrite cores used in the blocking filter for PLC were investigated as a function of additives. The highest density of 4.98 $g/cm^2$ and permeability of 8221 were obtained to the specimen added $MoO_3$ 400 ppm, $SiO_2$ 100 ppm and CaO 200 ppm since the microstructures were compacted through reduction of pores in the specimen. The permeability was increased up to 13094 at $110^{\circ}C$ with increasing temperature of specimen, however, it was decreased precipitously to under 100 over $110^{\circ}C$. The exothermic behavior was observed that the temperature of specimens became $102^{\circ}C$ at 1MHz. In the consequence, the ferrite core developed by this research will maintain the stable electromagnetic properties since the temperature of ferrite core rose to $93^{\circ}C$ in the range of 10kHz to 450kHz bandwidth qualified for PLC.

  • PDF

A Study on the Compensation Method for Unbalance Parallel Operation of Parallel Connected Thyristor Dual Converters using Circulating Current (순환 전류를 이용한 병렬 연결된 사이리스터 듀얼 컨버터의 불균형 병렬 운전 보상 기법에 관한 연구)

  • Kim, Sung-An;Han, Sung-Woo;Moon, Dong-Ok;Kim, Young-Woo;Lee, Chang-Hee;Cho, Yun-Hyun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.473-480
    • /
    • 2016
  • This study proposes a performance improvement for parallel-connected thyristor dual converters using a circulating current with an unbalanced parallel operation compensator. The proposed control method determines a variable reference value for the voltage PI controller according to voltage error at firing angle control applied to a difference current control. This method uses circulating current control to maintain a stable voltage and excellent current response during parallel operation. The effectiveness of the proposed control is verified with a simulation and an experiment based on the comparison of the performance of the proposed control method with other conventional methods.

Estimation of Delta Winding Current and Its Application to a Compensated-Current-Differential Relay for a Y-Δ Transformer

  • Kang, Yong-Cheol;Lee, Byung-Eun;Jin, En-Shu
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.255-263
    • /
    • 2010
  • The compensated-current-differential relay uses the same restraining current as a conventional relay, but the differential current is modified to compensate for the effects of the exciting current. Delta winding current is necessary to obtain the modified differential current for a $Y-\Delta$ transformer. This paper describes an estimation algorithm of the delta winding current and its application to a compensated-current-differential relay for a $Y-\Delta$ transformer. Prior to saturation, the core-loss current is calculated and used to modify the differential current. When the core first enters saturation, the initial value of the core flux is obtained by inserting the modified differential current into the magnetization curve. This flux value is used to derive the magnetizing current and consequently the modified differential current. The operating performance of the proposed relay was compared against a conventional current differential relay with harmonic blocking. Test results indicate that the proposed relay remained stable during severe magnetic inrush and over-excitation, and its operating time is significantly faster than a conventional relay. The relay is unaffected by the level of remanent flux and does not require an additional restraining or blocking signal to maintain stability. This paper concludes by implementing the proposed algorithm into a prototype relay based on a digital signal processor.

Safety Analysis of APR+ PAFS for CDF Evaluation (노심손상빈도 평가를 위한 APR+ PAFS의 안전 해석)

  • Kang, Sang Hee;Moon, Ho Rim;Park, Young Seop
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.123-128
    • /
    • 2013
  • The Advanced Power Reactor Plus(APR+), which is a GEN III+ reactor based on the APR1400, is being developed in Korea. In order to enhance the safety of the APR+, a passive auxiliary feedwater system(PAFS) has been adopted in the APR+. The PAFS replaces the conventional active auxiliary feedwater system(AFWS) by introducing a natural driving force mechanism while maintaining the system function of cooling the primary side and removing the decay heat. As the PAFS completely replaces the conventional AFWS, it is required to verify the cooling capacity of PAFS for the core damage frequency(CDF) evaluation. For this reason, this paper discusses the cooling performance of the PAFS during transient accidents. The test case and scenarios were picked from the result of the sensitivity analysis in APR+ Probabilistic Safety Assessment(PSA). The analysis was performed by the best estimate thermal-hydraulic code, RELAP5/.MOD3.3. This study shows that the plant maintains the stable state without the core damages under the given test scenarios. The results of PSA considering this analysis' results shows that the CDF values are decreased. The analysis results can be used for more realistic and accurate performance of a PSA.

Research on 5G Core Network Trust Model Based on NF Interaction Behavior

  • Zhu, Ying;Liu, Caixia;Zhang, Yiming;You, Wei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.10
    • /
    • pp.3333-3354
    • /
    • 2022
  • The 5G Core Network (5GC) is an essential part of the mobile communication network, but its security protection strategy based on the boundary construction is difficult to ensure the security inside the network. For example, the Network Function (NF) mutual authentication mechanism that relies on the transport layer security mechanism and OAuth2.0's Client Credentials cannot identify the hijacked NF. To address this problem, this paper proposes a trust model for 5GC based on NF interaction behavior to identify malicious NFs and improve the inherent security of 5GC. First, based on the interaction behavior and context awareness of NF, the trust between NFs is quantified through the frequency ratio of interaction behavior and the success rate of interaction behavior. Second, introduce trust transmit to make NF comprehensively refer to the trust evaluation results of other NFs. Last, classify the possible malicious behavior of NF and define the corresponding punishment mechanism. The experimental results show that the trust value of NFs converges to stable values, and the proposed trust model can effectively evaluate the trustworthiness of NFs and quickly and accurately identify different types of malicious NFs.

First-principles study of the initial-stage oxidation of Si(1110)-(7x7)

  • Lee, Sung-Hoon;Kang, Myung-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.147-147
    • /
    • 2000
  • Chemisorption of oxygen molecules on the Si(111)-(7x7) surface has been studied extensively as a model for the initial-stage oxidation of the surface. The basic step to the surface oxidation is the dissociation of the adsorbed O2 molecules, but the dissociation procedure and the atomic structure of the reaction products still remains as a subject of debates. We present here density-functional theory calculations on the initial-stage oxidation states of the Si adatom site for all possible dissociation configurations that can be generated by multiple O2 reactions. We determine the equilibrium structures and analyze their electronic and vibrational properties in comparison with measured UPS, XPS, and EELS spectra. The O(ad) atom bonded on top of the Si adatom is always less stable than the O(ins) atom inserted into one of the adatom backbonds. Our electronic and vibrational analysis demonstrates further that the O(ad) and O(ins) atoms account well for the metastable and stable features in previous experiments, respectively. Moreover, the calculated decay pathways of the metastable structures and the comparison of the calculated O ls core-level shifts with XPS data provides a convincing argument in unambiguously identifying the experimental metastable and stable structures, thereby making it possible to build a correct atomic-scale picture of the initial-stage oxidation process on this surface.

  • PDF

High-resolution Stable Isotope Analyses of the Otolith of Argyrosomus argentatus (고해상 시료 채취를 통한 보구치 이석의 안정동위원소 분석)

  • Khim, Boo-Keun;Lee, Tae-Won
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.1
    • /
    • pp.83-88
    • /
    • 2008
  • Using micromill, discrete carbonate powders from the otolith of Argyrosomus argentatus were sampled along the growth band, and high-resolution stable isotope profiles were obtained. The ${\delta}^{18}O$ and ${\delta}^{13}C$ values are increasing gradually from the core to the margin. However, such increases do not seem to be attributed to the environmental property changes during the growth, but to the dominant effect of metabolic carbons during the early growth, and then, the isotopic composition seems to be equilibrium to the environmental condition. This paper allows the diverse applicability of high-resolution isotope research to the fish otoliths in the future.

The Influence of Unstability of Supporting Surface on Trunk and Lower Extremity Muscle Activities During Bridging Exercise Combined With Core-Stabilization Exercise (중심 안정성 운동을 적용한 교각운동 시 지지면 불안정성이 체간 및 하지의 근 활성도에 미치는 영향)

  • Lee, Sim-Chul;Kim, Tack-Hoon;Cynn, Heon-Seock;Roh, Jung-Suk
    • Physical Therapy Korea
    • /
    • v.17 no.1
    • /
    • pp.17-25
    • /
    • 2010
  • The aim of this study was to investigate the effect of supporting surface instability to trunk and lower extremity muscle activities during bridging exercise combined with core-stabilization exercise. Thirty young healthy adults (15 males and 15 females) voluntarily participated in this study. Each subject was asked to perform bridging exercise combined with core-stabilization exercise on three different supporting surfaces (stable ground surface, the wooden balancing board, and the air cushion). The muscle activities were measured using surface electromyography (EMG) during performing exercise. To test statistical significance, one-way ANOVA with repeated measures was used with the significance level of .05. The findings of this study are summarized as follows. (1) There were significant differences in muscle activities on internal oblique, external oblique, gluteus medius, semitendinosus, biceps femoris, medial gastrocnemius and lateral gastrocnemius during exercise (p<.05). (2) The biceps femoris and lateral gastrocnemius showed significantly higher muscle activity on the wooden balancing board rather than on the ground, and semitendinosus, biceps femoris, medial gastrocnemius and lateral gastrocnemius showed significantly higher muscle activity on the air cushion rather than on the ground (p<.05). Therefore, it is concluded that muscle activities in the trunk and the lower limbs during bridging exercise combined with core-stabilization exercise was affected with instability of supporting surface. Further researches are needed to investigate the long term effect of bridging exercise on muscle activity with patient group.

Major Element Changes in the Upper Quaternary Sediment of the East Sea (Sea of Japan): Their Implications for the Onset of Holocene

  • Hyun, Sang-Min;Han, Sang-Joon;Bahk, Jang-Jun
    • Journal of the korean society of oceanography
    • /
    • v.33 no.4
    • /
    • pp.185-195
    • /
    • 1998
  • Two piston cores (94PC-2 and 95PC-4) taken from the East Sea (Sea of Japan) are studied to evaluate the paleoceanographic changes and its interaction with climatic variation. The bulk geochemistry of the non-biogenic fractions of 54 sediment samples is determined using X-ray fluorescence. Four geochemical stratigraphic units at both core sediments are recognized based on the variations in major element concentration. These chemical stratigraphic units correspond well with the sedimentological and paleontological facies. Source materials are considered as basic and/or intermediate rocks judging from silica content. A distinctive boundary around 11 kyr may correspond to Younger Dryas event. The switch of most major elements at this level and the distinctive changes in concentration of typical terrigenous elements (TiO$_2$ and Al$_2$O$_3$) are the strong evidence for the difference in sources of terrigenous materials. The weathering indices exhibit high degree in Core 94PC-2 and low degree in Core 95PC-4. The changes in weathering degree can be distinguished by the lowest value occurred at 11 kyr in Core 94PC-2 and by a gradual decrease from top to bottom in Core 95PC-4. The profiles of potassium and sodium exhibit specific excursions between the Holocene and the late Pleistocene. This implies that sediments of the two cores originating from different sources with different weathering degrees. The distinct two-group distributions in K$_2$O/CaO vs. Na$_2$O/K$_2$O also support the difference in provenance of aluminosilicate materials at the boundary of 11 kyr. Thus, supply patterns of terrigenous materials are stable in Holocene and more complicated in the last glacial period.

  • PDF

Energy analysis-based core drilling method for the prediction of rock uniaxial compressive strength

  • Qi, Wang;Shuo, Xu;Ke, Gao Hong;Peng, Zhang;Bei, Jiang;Hong, Liu Bo
    • Geomechanics and Engineering
    • /
    • v.23 no.1
    • /
    • pp.61-69
    • /
    • 2020
  • The uniaxial compressive strength (UCS) of rock is a basic parameter in underground engineering design. The disadvantages of this commonly employed laboratory testing method are untimely testing, difficulty in performing core testing of broken rock mass and long and complicated onsite testing processes. Therefore, the development of a fast and simple in situ rock UCS testing method for field use is urgent. In this study, a multi-function digital rock drilling and testing system and a digital core bit dedicated to the system are independently developed and employed in digital drilling tests on rock specimens with different strengths. The energy analysis is performed during rock cutting to estimate the energy consumed by the drill bit to remove a unit volume of rock. Two quantitative relationship models of energy analysis-based core drilling parameters (ECD) and rock UCS (ECD-UCS models) are established in this manuscript by the methods of regression analysis and support vector machine (SVM). The predictive abilities of the two models are comparatively analysed. The results show that the mean value of relative difference between the predicted rock UCS values and the UCS values measured by the laboratory uniaxial compression test in the prediction set are 3.76 MPa and 4.30 MPa, respectively, and the standard deviations are 2.08 MPa and 4.14 MPa, respectively. The regression analysis-based ECD-UCS model has a more stable predictive ability. The energy analysis-based rock drilling method for the prediction of UCS is proposed. This method realized the quick and convenient in situ test of rock UCS.