• Title/Summary/Keyword: stabilizing cable

Search Result 12, Processing Time 0.03 seconds

Design of aerodynamic stabilizing cables for a cable-stayed bridge during construction

  • Choi, Sung-Won;Kim, Ho-Kyung
    • Wind and Structures
    • /
    • v.11 no.5
    • /
    • pp.391-411
    • /
    • 2008
  • A design procedure of stabilizing cable is proposed using buffeting analysis to stabilize the seesaw-like motion of the free cantilevered structure of a cable-stayed bridge during its construction. The bridge examined is a composite cable-stayed bridge having a main span length of 500 m. Based on the buffeting analysis, the stress in bare structure exceeded the allowable limit and a set of stabilizing cable was planned to mitigate the responses. The most efficient positions of the hold-down stabilizing cables were numerically investigated by means of an FE-based buffeting analysis and the required dimensions and pretension of the stabilizing cables were also calculated. The proposed stabilizing measure would be expected to secure the aerodynamic safety of a cantilevered structure under construction with considerable mitigation of buffeting responses.

An Analysis of Stabilizing Process of Cable Dome and Its Application (케이블 돔의 안정화 이행과정해석 및 적용)

  • HwangBo, Seok;Yoo, Yong-Ju;Han, Sang-Eul
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.2 s.20
    • /
    • pp.69-76
    • /
    • 2006
  • Cable dome is one of tension structure which is gradually stabilized by tensioning tables from initially unstable state to finally stable state. This stabilizing process is not able to be developed by general analysis because some cables endure compression forces during stabilizing process. Thus, this paper uses dynamic relaxation method to solve this problem. To apply this stabilizing process analysis to the actual project, this paper deals with cable dome roof of Seoul Olympic Gymnasium. Finally, this paper prove the usefulness of stabilizing process analysis by comparing the analysis results and the measurements.

  • PDF

Temporary Stabilizing Measures during Construction of a Steel Composite 2-Edge Girder Cable Stayed Bridge (강합성 2주형 사장교의 시공중 내풍 안정성 확보 방안 연구)

  • Kim, Young-Min;Kim, Dae-Young
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.63-66
    • /
    • 2008
  • The bridge deck section composed of a concrete slab resting on two I-beam girders are known to be susceptible to flutter instability and vortex shedding. Moreover, the cable stayed bridge in construction is more vulnerable to wind rather than in service when the free cantilever construction method is applied. This paper describes the effect of the dynamic wind loads on the bridge during construction and the effect of alternative temporary stabilizing measures. Therefore, a series of wind tunnel tests and numerical analysis were carried out to determine if any countermeasures were required.

  • PDF

Comparison of Aerodynamic Responses for Cable-Stayed Bridges during Construction with Temporary Stabilizing Measures (내풍케이블 배치에 따른 가설 중 사장교의 공기역학적 거동 비교)

  • Cho, Jae Young;Kim, Young Min;Lee, Hak Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.2
    • /
    • pp.147-160
    • /
    • 2007
  • In this paper, we described the aeroelastic full-bridge model tests that were conducted to investigate the effect of alternative temporary stabilizing measures for thecable-stayed bridge during construction to ensure aerodynamic stability in the event of a typhoon or similar disasters. The effect of alternative temporary stabilizing measures was investigated through various configurations on two cable-stayed bridges with a main span of 475 m and 230 m, respectively. To investigate the bridge's aerodynamic behaviour and dynamic wind force during construction, the deflections at the end of the cantilever, the accelerations atthe top of the pylon and the moments at the lower part of the pylon were measured. As the result, the system with two sets of vertical cables per cantilever seemed to be the overall most effective solution, but the system with single vertical cable may also work. The combined system using the caisson support and vertical cables and the system with two sets of inclined cables per cantilever on the same anchor block may also be a solution. The inclined cables from the caisson to the girder were effective for some early stages of erecting the deck.

A Study on the Stabilizing Process and Structural Characteristics of Cable-Dome Structure (케이블돔 구조물의 안정화 이행과정 및 구조적 거동특성에 관한 연구)

  • 한상을;이경수;이주선;황보석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.04a
    • /
    • pp.260-267
    • /
    • 1999
  • In this paper, We propose the initial shape finding and dynamic analysis of cable dome structure are presented. Cable dome that is consist of three component such as cable, strut and fabric membrane have complex structural characteristics. Main structural system of cable dome is cable-strut tensegric system, and fabric membrane element Is conceived as cladding roof material. One of the important problem of cable dome is shape finding of those subjected to cable and membrane forces, which stabilize the structures. And the other is structural response from external load effect such as snow and wind When cable dome are subjected to dynamic load such as wind load each structural component has many important problem because of their special structural characteristics. One problem is that geometrical nonlinearity should be considered in the dynamic analysis because large deformation is occurred from their flexible characteristic. The other problem is that wrinkling occurs occasionally because cable and membrane elements can not transmit compressive forces. So this paper describe the physical structural response of cable dome structure.

  • PDF

The study on the prevention of DC feeder line cable grounding fault (DC 급전케이블 지락사고 보호방안에 관한 연구)

  • Park, Ji-Soo;Song, Joong-Ho;Park, Joung-Wook
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.202-207
    • /
    • 2008
  • This study provides review and improvement plans for the possible problems caused when the CV cable is used as a positive feeder line which supplies power from the DC HSCB (high-speed circuit breaker) to the catenariesin Seoul Metro which is using direct-current feeder method. In detail, this study contributes to stabilizing the power line by triggering a protective device by instantly detecting potential rise which happens when grounding fault occurs in non-grounding type CV cable shield.

  • PDF

Analysis of Stabilizing Process for the Unstable Truss Structures using a Topology of Member Connection (구성부재의 위상을 이용한 불안정 트러스 구조물의 안정화 이행과정)

  • 권택진;김진우;김재열
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.251-258
    • /
    • 2001
  • Cable and membrane structures can be classified as a unstable structure in the view point of shape determination process. An unstable stucture at the initial state generally cannot take a role as the resistance for the external force. Therefore, there should be a stabilizing process to get the stable state of a structure and it is necessary to visualize the shape finding from unstable state to stable state. In this paper, a numerical method of stabilizing procedure for the link structures is presented. The structures are assumed to have rigid movements and thus only changing of the topology of member is considered during the analysis. The generalized inverse matrix and the principle of minimum potential energy are used in the process. Illustrative examples are presented and the results show good convergence.

  • PDF

Experimental and numerical studies on VIV characteristics of π-shaped composite deck of a cable-stayed bridge with 650 m main span

  • Wei Lei;Qi Wang;Haili Liao;Chengkai Shao
    • Wind and Structures
    • /
    • v.38 no.2
    • /
    • pp.93-107
    • /
    • 2024
  • A π-shaped composite deck in the form of an open section is a type of blunt body that is highly susceptible to wind loads. To investigate its vortex-induced vibration (VIV) performance, a large-scale (1/20) section model of a cable-stayed bridge with a main span of 650 m was tested in a wind tunnel. The vibration suppression mechanism of the countermeasures was analyzed using computational fluid dynamic. Experimental results demonstrate that the vertical and torsional VIVs of the original section can be suppressed by combining guide plates with a tilt angle of 35° and bottom central stabilizing plates as aerodynamic countermeasures. Numerical results indicate that the large-scale vortex under the deck separates into smaller vortices, resulting in the disappearance of the von Kármán vortex street in the wake zone because the countermeasures effectively suppress the VIVs. Furthermore, a full-bridge aeroelastic model with a scale of 1/100 was constructed and tested to evaluate the wind resistance performance and validate the effectiveness of the proposed countermeasures.

Design of Dielectric Detector for FRP Hot Stick in EHV Live line Maintenance

  • Chawporn, Talerngkiat;Sriratana, Witsarut;Trisuwannawat, Thanit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2063-2066
    • /
    • 2005
  • This paper presents an approach to detect the dielectric condition of FRP Hot Stick in EHV high voltage cable whereas shutting down the power system is not necessary. The radio frequency generating method is adopted by transmitting radio wave into the Electrodes. This instrument is small, easy to use and also inexpensive. Furthermore, the impurity level of dirt on high voltage insulator (non-ceramic type) will be analyzed by using the methods based on IEEE Std.978-1984 at 105 kV.DC. /305 mm. and OSHA Regulation 1910.269 Part J - live line tools. The frequency at 10-20 MHz is applied to FRP Hot Stick via Electrode1 and from FRP Hot Stick surface to Electrode 2. After that the results will be evaluated by testing in each condition of FRP Hot Stick, such as dry surface, hot surface, foil winding and conductor inserting. Finally, the watt loss will be examined and compared with the loss from humidity and Carbon tracking. The important components of this system are radio frequency generating unit, frequency stabilizing unit, frequency amplifier, FRP Hot Stick frequency counter, processing unit, and display unit.

  • PDF