• Title/Summary/Keyword: stability of deterioration

Search Result 280, Processing Time 0.03 seconds

Development of Equipment to Measure Insulation Resistance and Evaluate the Lifetime of High-voltage Cable in Operation (운전 중인 고전압 케이블의 절연저항 측정 및 수명평가장치의 개발)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.237-242
    • /
    • 2014
  • In this paper, we find out the lifetime index in order to determine the time-dependent trend of deteriorating performance of 6.6kV high-voltage power cable in operation at a power station. The cable systems used in our study have been in operation for 13 years. With measurements for the 13 years, we analyzed the insulation resistances. By developing measuring equipment (comprized mainly of transformer, temperature sensor, and LPF) operating by the three-phase electric power, we analyzed the changing characteristics of insulation resistance of power cable. In contrast to 22kV cables, 6.6 kV cables have thicker insulation. Therefore the characteristics of 6.6kV cables are different from that of 22kV cables. The study found that as time passes, the insulation resistance does not decrease continuously; it decreases to a certain value, then does not decrease any more and shows properties of oscillation. We could not detect the process of deterioration in the preceding twelve years. The cable system showed great stability so that deterioration was not apparent. In this case, it is not possible to measure the future life indices of power cables because the lifetime indices are not predictable

Tensile Strength Changes of Pinus densiflora root in Fire Damaged Forest Area (산불피해지에 있어서 소나무 뿌리의 인장강도특성 변화)

  • Cha, Du Song;Oh, Jae-Heun;Lee, Jung Su
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.4
    • /
    • pp.392-397
    • /
    • 2008
  • To characterize the root strength changes of Pinus densiflora by elapsed years after forest fire, we measured and analyzed the tensile force and strength of the roots using the universal testing machine for 4 years. The deterioration rate of the root strength was higher in small diameter class than that in large diameter class. Especially, the deterioration was highest of the root strength at the second year in all surveyed diameter classes and the mean deterioration rate of the root strength was 61% by that time. The tensile strength based on the simulation by ordinary differential equations deteriorated more than 50% in all diameter classes within 2 years after forest fire.

Effects of sodium diacetate or microbial inoculants on aerobic stability of wilted rye silage

  • Li, Yan Fen;Wang, Li Li;Jeong, Eun Chan;Kim, Hak Jin;Ahmadi, Farhad;Kim, Jong Geun
    • Animal Bioscience
    • /
    • v.35 no.12
    • /
    • pp.1871-1880
    • /
    • 2022
  • Objective: The primary goal was to identify the effectiveness of chemical or biological additives in delaying the deterioration of early-harvested wilted rye silage after exposure to air. Methods: Rye harvested as a whole plant at the early heading stage was wilted for 24 h. The wilted forage was divided into treatments including sodium diacetate (SDA) at 3 (SDA3) and 6 g/kg (SDA6), Lactobacillus plantarum (LP), L. buchneri (LB), or their equal mixture (LP+LB) at 1×106 colony-forming unit/g fresh matter. Results: After 60 d of conservation in 20-L silos, lactic acid was greater in LP and LP+LB silages than other treatments (102 vs 90.2 g/kg dry matter [DM]). Acetic acid was greatest in SDA6 (32.0 g/kg DM) followed by LB (26.1 g/kg DM) and was lowest in LP treatment (4.73 g/kg DM). Silage pH was lower with microbial inoculation and the lowest and highest values were observed in LP and untreated silages, respectively. After 60 d, neutral detergent fiber concentration was lowest in SDA6 silages, resulting in the greatest in vitro DM digestibility (846 g/kg DM). Aerobic stability was longest in SDA6 (176 h) followed by LB treatment (134 h). Instability after aerobiosis was greatest in LP silages (68 h), about 8 h less than untreated silages. After aerobic exposure, yeast and mold numbers were lowest in SDA6 silages, resulting in DM loss minimization. Exhaustion of acetic acid and lactic acid after aerobic exposure was lowest with SDA6 but greatest with untreated and LP silages. Conclusion: Treatment of early-cut wilted rye forage with SDA at 6 g/kg resulted in silages with higher feeding value and fermentation quality, and substantially delayed deterioration after aerobic exposure, potentially qualifying SDA at this load for promotion of silage quality and delaying aerobic spoilage of early-harvested (low DM) rye forage.

Thermal Stability of SiO2 Doped Ge2Sb2Te5 for Application in Phase Change Random Access Memory

  • Ryu, Seung-Wook;Ahn, Young-Bae;Lee, Jong-Ho;Kim, Hyeong-Joon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.3
    • /
    • pp.146-152
    • /
    • 2011
  • Thermal stability of $Ge_2Sb_2Te_5$ (GST) and $SiO_2$ doped GST (SGST) films for phase change random access memory applications was investigated by observing the change of surface roughness, layer density and composition of both films after isothermal annealing. After both GST and SGST films were annealed at $325^{\circ}C$ for 20 min, root mean square (RMS) surface roughness of GST was increased from 1.9 to 35.9 nm but that of SGST was almost unchanged. Layer density of GST also steeply decreased from 72.48 to 68.98 $g/cm^2$ and composition was largely varied from Ge : Sb : Te = 22.3 : 22.1 : 55.6 to 24.2 : 22.7 : 53.1, while those of SGST were almost unchanged. It was confirmed that the addition of a small amount of $SiO_2$ into GST film restricted the deterioration of physical and chemical properties of GST film, resulting in the better thermal stability after isothermal annealing.

Analysis of Development Trends on Bio-based Environmental Transformers Oils in Power Sector (전력분야의 바이오 기반 친환경 전기 절연유 적용에 관한 개발 동향 분석)

  • Kim, Jae-Kon;Min, YoungJe;Kim, Mock-Yeon;Kwark, ByeongSub;Park, Hyunjoo
    • Tribology and Lubricants
    • /
    • v.38 no.2
    • /
    • pp.41-52
    • /
    • 2022
  • Mineral electrical insulating oil, which is widely used in transformers, exhibits excellent cooling performance and transformer efficiency. However, given that it is composed of petroleum-based components, it is weak in terms of biodegradability. This causes environmental problems in case of leakage and a low flash point, which is a factor that would cause great damage in the event of a fire in a substation. In this context, the use of eco-friendly electric insulating oil composed of bio-based vegetable oil and synthetic ester, which has excellent biodegradability and flame retardancy performance, has recently been expanded to the field of electric power, and various research and development (R&D) studies are in progress. According to different research results, vegetable oil and synthetic ester manufacturing technology, thermal stability, oxidation stability, property change, and quality control, which are characteristics of eco-friendly electrical insulating oils, are major factors affecting the maintenance of insulating oil properties. In addition, power companies have established and operated quality control standards according to the use of eco-friendly electrical insulating oil as they expand the exploitatoin of renewable energy in electricity production. In particular, deterioration and oxidation characteristics were jointly identified in R&D as an important influencing factor according to the content of saturated and unsaturated fatty acids present in vegetable oils and synthetic esters in power transformer applications.

A Study on the Combustion Stability and Characteristics for D.O - Methanol Blending Oil in Diesel Engine (디젤기관에서의 경유-메탄올 혼합유의 연소 안전성과 연소특성에 관한 연구)

  • Kim, Sang-Am;Wang, Woo-Gyeong
    • Journal of Power System Engineering
    • /
    • v.22 no.1
    • /
    • pp.48-55
    • /
    • 2018
  • It has recently been reported that methanol fuel has been used in the product carrier with established duel fuel engine, which has been greatly reducing emissions of $CO_2$, NOx and SOx from the engine. However, to use methanol alone as fuel oil in a general diesel engine, design modification of cylinder head is needed because the ignition aid device or the duel fuel injection system is needed. On the other hand, only if the mixer is installed on the fuel oil supply line, diesel oil - methanol blending oil can be used as fuel oil for the diesel engine, but there is a problem of the phase separation when two fuels are mixed. In this study, diesel oil and methanol were blended compulsorily in preventing the phase separation with installing agitators and a fuel oil boost pump on fuel line of a test engine. Also, cylinder pressure and fuel consumption quantity were measured according to engine load and methanol blending ratio, and indicated mean effective pressure, heat release rate and combustion temperature obtained from the single zone combustion model were analyzed to investigate the effects of latent heat of vaporization of methanol on combustion stability and characteristics. As a result, the combustion stability and characteristics of 10% methanol blending oil are closest to the those of diesel oil, and it could be used as fuel oil in existing diesel engines without deterioration of engine performance and combustion characteristics.

The Addition Effect of Lentil and Opuntia ficus-indica on Storage Stability for Sausages (렌틸과 백년초의 첨가가 소시지의 저장 안정성에 미치는 영향)

  • Lee, Namrye;Park, Man Chun;Noh, Dan Bee;Yook, Hong Sun
    • Korean journal of food and cookery science
    • /
    • v.31 no.5
    • /
    • pp.565-573
    • /
    • 2015
  • This study was carried out to clarify the addition effects of lentil and Opuntia ficus-indica instead of nitrite on storage stability for sausages. The antioxidant activity, acid value, peroxide value, volatile basic nitrogen and total aerobes were determined. As the concentration of lentils and Opuntia ficus-indica increased, total polyphenol and DPPH radical scavenging effects increased significantly. The F6 batch which had the maximum concentration of lentil and Opuntia ficus-indica, had the highest polyphenol value and DPPH radical scavenging effects. In addition, lentil and Opuntia ficus-indica supplementation lowered acidity, peroxide value and volatile basic nitrogen of sausages. Therefore, addition of lentil and Opuntia ficus-indica showed inhibition effects on lipid oxidation and protein deterioration of sausages. Also, Opuntia ficus-indica dropped pH, while lentil raised the pH. Bacterial counts didn't have an effect with the concentration of lentil and Opuntia ficus-indica on initial storage day. Overtime, the bacterial growth in the supplemented sausage group was less than the growth in no supplementation sausages. These results indicate that the addition of lentil and Opuntia ficus-indica increase antioxidative activity and inhibit lipid oxidation, protein deterioration and microbial growth. Lentil and Opuntia ficus-indica are useful materials in sausage production.

Mechanical and Electrical Failure of ITO Film with Different Shape during Twisting Deformation (비틀림 변형 중 ITO 필름의 시편 형태에 따른 기계적 전기적 파괴 연구)

  • Kwon, Y.Y.;Kim, Byoung-Joon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.53-57
    • /
    • 2017
  • The most representative transparent electrode in the modern society is ITO (Indium Tin Oxide). ITO is widely used in general for touch panels and displays due to its high electrical and optical properties. However, in general, mechanical deformation causes deterioration and destruction of device properties because ITO is basically vulnerable to mechanical deformation. Therefore, the in-depth understanding on the stability of ITO film during various mechanical deformations is necessary. In this study, the reliability and mechanical properties ITO sample having different length, width, and area were investigated. The electrical stability was estimated according to electrical resistance change. The stability was dropped as the sample length, and width increased and the sample area decreased. The electrical stability of ITO film was correlated with twisting strain including tensile, compressive and shear stress.

Strength and failure characteristics of the rock-coal combined body with single joint in coal

  • Yin, Da W.;Chen, Shao J.;Chen, Bing;Liu, Xing Q.;Ma, Hong F.
    • Geomechanics and Engineering
    • /
    • v.15 no.5
    • /
    • pp.1113-1124
    • /
    • 2018
  • Geological dynamic hazards during deep coal mining are caused by the failure of a composite system consisting of the rock and coal layers, whereas the joint in coal affects the stability of the composite system. In this paper, the compression test simulations for the rock-coal combined body with single joint in coal were conducted using $PFC^{2D}$ software and especially the effects of joint length and joint angle on strength and failure characteristics in a rock-coal combined body were analyzed. The joint length and joint angle exhibit a deterioration effect on the strength and affect the failure modes. The deterioration effect of joint length of L on the strength can be neglected with a tiny variation at ${\alpha}$ of $0^{\circ}$ or $90^{\circ}$ between the loading direction and joint direction. While, the deterioration effect of L on strength are relatively large at ${\alpha}$ between $30^{\circ}$ and $60^{\circ}$. And the peak stress and peak strain decrease with the increase of L. Additionally, the deterioration effect of ${\alpha}$ on the strength becomes larger with the increase of L. With the increase of ${\alpha}$, the peak stress and peak strain first decrease and then increase, presenting "V-shaped" curves. And the peak stress and peak strain at ${\alpha}$ of $45^{\circ}$ are the smallest. Moreover, the failure mainly occurs within the coal and no apparent failure is observed for rock. At ${\alpha}$ between $30^{\circ}$ and $60^{\circ}$, the secondary shear cracks generated in or close to the joint tips, cause the structural instability failure of the combined body. Therefore, their failure models present as a shear failure along partial joint plane direction and partially cutting across the coal body or a shear failure along the joint plane direction. However, at ${\alpha}$ of $60^{\circ}$ and L of 10 mm, the "V-shaped" shear cracks cutting across the coal body cause its final failure. While crack nucleations at ${\alpha}$ of $0^{\circ}$ or $90^{\circ}$ are randomly distributed in the coal, the failure mode shows a V-shaped shear failure cutting across the coal body.

Material Characteristics and Nondestructive Deterioration Assessment for the Celestial Chart Stone, Korea (천상열차분야지도 각석의 재질특성과 비파괴 훼손도 평가)

  • Yoo, Ji Hyun;Lee, Myeong Seong;Choie, Myoungju;Ahn, Yu Bin;Kim, Yuri
    • The Journal of the Petrological Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.207-222
    • /
    • 2018
  • Celestial Chart Stones (original and reproduction) in the National Palace Museum are representative scientific cultural heritage of Korea. Material analysis and nondestructive deterioration assessment were conducted for long-term preservation of these stones. Material analysis revealed that the original was composed of slate and the reproduction was made of dolostone. The original consists of quartz, mica, dolomite minerals, while the reproduction was made up of dolomite, calcite and forsterite. Major deterioration factors of the original stone were cracks and breakouts. In case of the reproduction, scratches and artificial materials were mainly observed. The green and black surface contaminants present at the sides and back of the two celestial chart stones were interpreted as resin-based paint materials. The physical property evaluation using ultrasonic velocity showed a low velocity in the upper left side of the original, while the front right side of the reproduction showed a weak property. Meanwhile, the To-Tc method using ultrasonic velocity was applied to major cracks that impede stability of the original. As a result, it has been calculated that the beginning and the center of the crack are the deepest.