• Title/Summary/Keyword: stability of deterioration

Search Result 280, Processing Time 0.029 seconds

Dehydration of foamed sardine-starch paste by microwave heating. (고주파가열을 이용한 정어리 발포건조제품의 가공 II. 제품저장중의 품질변화와 저장기간)

  • 이병호
    • Journal of the Korean Professional Engineers Association
    • /
    • v.17 no.4
    • /
    • pp.8-14
    • /
    • 1984
  • In this part of the studies on dielectric dehydration of foamed fish-starch paste, quality stability and shelflife of the product of which the preparation formula and processing conditions were described in the previous report (Lee et at., 1982) were determined by means of accelerated reaction test. The product was stored for 50 days under the conditions of temperatures at 35, 45, and 55$^{\circ}C$ in steady state and various water activities of 0.44, 0.52, 0.65, and 0.75, respectively. The loss of available lysine, the extent of TBA value, and the development of browning during the storage were measured and reaction kinetically analysed to assess quality stability and shelf-life of the product for the storage at room temperature of 25$^{\circ}C$. The extent of browning was accelerated with the increase of water activity and temperature marking the time to reach a limit of color and flavor deterioration, or to reach brown color density of 0.17 O.D./g at 420nm, 106 days at a$\_$w/=0.44, 35$^{\circ}C$, and 41 days at aw=0.65, 55$^{\circ}C$. These reaction rates resulted in a prediction of shelf-life, 130 to 110 days in the storage at au=0.44 to 0.75, 25$^{\circ}C$. The quality limit assessed by TBA values and sensory evaluation of rancidity was 87 days at a$\_$w/=0.44, 35$^{\circ}C$, and 30 days at aw=0.73, 55$^{\circ}C$ which gave a predicted shelf-life, 128 to 113 days at a$\_$w/=0.44 to 0.75, 25$^{\circ}C$ storage.

  • PDF

Design Improvement of the Road Expansion on a Deep Thick Soft Ground (대심도 연약지반 도로확장 공사에서의 설계 개선)

  • Kim, Tae-Hyung;Park, Tae-Young;Kim, Sung-Ryul;You, Sang-Ho;Kim, Kook-Han;Kim, Yun-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.8
    • /
    • pp.89-99
    • /
    • 2012
  • The expansion of a road on soft ground could induce an additional settlement to the existing road because of the consolidation characteristics of the soft soil layer subjected to additional load by an adjacent banking. In such case, the existing road could be faced with various problems during the stages of the construction and maintenance, such as deterioration of not only the surface smoothness yielding the decrease in automobile performance safety but also the structural stability of the embankment. These kinds of problems are expected to occur more freguently especially for the deep ground level with a fairly thick soft soil layer. Therefore, they should be examined and studied adequately during the design stage. As a reference case study, this paper deals with the project named Namhae Expressway of 2nd Branch with the soft soil layer with the thickness upto about 50m. After a lengthy review of the original design, an improved design is proposed.

The Development of Integrated Power Quality Diagnosis System for Power System (전력계통 전력품질 통합진단시스템 개발)

  • Kwak, N.H.;Jeon, Y.S.;Park, S.H.;Lee, I.M.;Park, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.277-279
    • /
    • 2005
  • Recently, due to the increase of power conversion devices and nonlinear loads with the development of information, communication and control technologies, the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, flicker etc. have greatly threatened the power quality, and the deterioration of electric power facilities and the functional error of controllers are increasing. As such an instantaneous minute interruption appears to be small and local, accurate evaluation with measurement is difficult and total analysis system is required through a wide range of power quality effect analysis such as the simultaneous measurement on various power supply phenomena and the analysis on the interrelation with system loads. Most of conventional power quality diagnosis equipments have beer developed and applied, which were able to measure the stability rate of frequency, the stability rate of voltage, the electricity-failure duration etc, However, they were insufficient to analyze the system present situation, understand the cause of the failure occurred by the problem of power quality and analyze out the phenomena. Accordingly, this study will address the development of the system for a wide range of power quality diagnosis over the present level, the system for supporting the determination such as the analysis on risk factors, failure mode and impact, the system for harmonic evaluation based on international standards(IEC 61000 Series) and the total power quality diagnosis network & system with the extension and openness as a local and national-scale broadband power quality diagnosis system.

  • PDF

Corrosion Behavior of As-Cast and Solution-Treated AZ91-4%RE Magnesium Alloy (주조 상태 및 용체화처리한 AZ91-4%RE 마그네슘 합금의 부식 거동)

  • Han, Jin-Gu;Hyun, Soong-Keun;Jun, Joong-Hwan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.31 no.5
    • /
    • pp.220-230
    • /
    • 2018
  • The objective of this study is to investigate the effect of solution treatment on the microstructure and corrosion behavior of cast AZ91-4%RE magnesium alloy. In the as-cast state, microstructure of the AZ91-4%RE alloy was characterized by intermetallic ${\beta}(Mg_{17}Al_{12})$, $Al_{11}RE_3$ and $Al_2RE$ phase particles distributed in ${\alpha}-(Mg)$ matrix. After solution treatment, the ${\beta}$ particles with low melting point dissolved into the matrix, but Al-RE phases still remained due to their high thermal stabilities. It was found from the immersion and potentiodynamic polarization tests that corrosion rate of the AZ91-4%RE alloy increased after the solution treatment. On the contrary, EIS tests and EDS compositional analyses on the surface corrosion products indicated that the stability of the corrosion product was improved after the solution treatment. Examinations on the corroded microstructures for the ascast and solution-treated samples revealed that dissolution of the ${\beta}$ particles which play a beneficial role in suppressing corrosion propagation, would be responsible for the deterioration of corrosion resistance after the solution treatment. This result implies that the microstructural features such as amount, size and distribution of secondary phases that determine corrosion mechanism, are more influential on the corrosion rate in comparison with the stability of surface corrosion product.

Evaluation on Quality of Life in Urban with Weighting Analysis by Cohort (연령별 가중치 분석을 통한 도시의 삶의 질 지표선정)

  • Kim, Sun-Ho;Cheong, Hye-Young;Lee, Myeong-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.7
    • /
    • pp.453-462
    • /
    • 2012
  • The purpose of this study is to analyze the quality of life and provide an objective evaluation, and differentiated according to the local population for the realization of the quality of life policies are intended to provide baseline data. This study analyzed to the Development of Quality of Life indicators and weights for age differences in the quality of life, first to select the literature and previous studies analyzing the primary evaluation criteria. Second, the final evaluation of professional conduct FGI indicators are derived. Third, experts will conduct analysis to target weights. As a result of the first domain-specific weights family safety, economic stability, residential culture, health and welfare, and traffic environment in order. In particular, a family safe zone more than twice that of the other areas appeared to be important. Is determined. Second, age weighted analysis, the higher the age, economic stability, while important, safe area for families, the more the weight of age shows a deterioration. As income increases per capita housing area and the city park area, the exhibition shows the importance of housing across all age, environment, culture, suggests that increasing interest will.

Hydrogen Brittleness on Welding Part for SDS Bottles (삼중수소 저장용기 이종 접합부의 수소 취성)

  • Kim, Raymund K.I.;Jung, Seok;Kang, Hyungoo;Chang, Minho;Yun, Seihun;Hong, Tae-Whan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.2
    • /
    • pp.121-127
    • /
    • 2013
  • Tritium was attracted with high energy source in neutron fusion energy systems. A number of research was performed in tritium storage materials. The Korea was raised storage and delivery systems (SDS) of international thermonuclear experimental reactor (ITER) research. However, bottles of SDS would be important because of stability. The bottles have a welding zone, this zone will be vulnerable to hydrogen embrittlement. This zone have a high thermodynamic energy and heat deterioration. Therefore bottles were studied about hydrogen embrittlement to retain stability. The heat treatment of hydrogen was carried under pressure-composition-temperature (PCT) apparatus because of checking at real time. And then, mechanical properties were evaluated by tensile test and hardness test. In results of this study, hydrogen atmosphere condition is very important by tensile test and kinetics test. The samples were evaluated, that is more weak hydrogen pressure, increasing temperature and time. This results could be useful in SDS bottle designs.

Study on the Mechanical Properties of Polyketone Fiber according to Dyeing and Finishing Process (폴리케톤 섬유의 염색 및 후가공 처리에 따른 기계적 물성에 관한 연구)

  • Kim, Sang Yong;Kim, Kyung Min;Lee, Won;Lee, Deuk Jin;Whang, Sun Dong;Yang, Sung Yong
    • Textile Coloration and Finishing
    • /
    • v.29 no.2
    • /
    • pp.97-103
    • /
    • 2017
  • Polyketone fiber, a newly developed high strength fiber, has a tenacity and modulus similar to the p-aramid fiber, and can be used for reinforcing mechanical rubber goods(MRG), such as tires, hoses, and technical textiles. It will be expected for replacement of super fiber such as aramids and increasing the technical textile market share. This paper surveys the mechanical properties of polyketone fiber for technical textiles. For this purpose, dyed polyketone fabric is prepared, mechanical properties of coated and uncoated polyketone fabrics such as tensile strength, elongation and tear strength were examined before and after weather resistance test(temperature $63{\pm}3^{\circ}C$, humidity 60%, amount of power $0.35w/m^2$). The differences of mechanical properties between uncoated and coated fabrics for high functional technical textiles and composite materials are estimated through this study. The UV-stability of polyketone fabric showed obvious improvement after coating. After 168h(7day) of UV exposure, the coated fabric showed less deterioration in mechanical properties with the retained tensile strength and elongation at break greater than 22 and 17% of the uncoated polyketone fabrics values, respectively.

Study on Improving Proximity Evaluation Standards when Excavating Tunnels Adjacent to Urban Infrastructure (도시기반시설 인접 터널 굴착시 근접도 평가기준 개선방안 연구)

  • Chul Lee;Guk-Hwan Cho
    • Tunnel and Underground Space
    • /
    • v.34 no.4
    • /
    • pp.283-300
    • /
    • 2024
  • Due to the revitalization of urban development, the number of cases of excavating tunnels adjacent to existing subways is increasing. This may affect the structure and track of the existing subway, resulting in reduced stability and usability. In this study, we verified the adequacy of the proximity evaluation range to ensure the stability of new tunnels and existing subways when excavating adjacent to tunnels, and proposed a quantitative correction rate considering various conditions. Conditions for applying the correction rate considered rock grade, geologically weak section, structurally weak section, and structural deterioration section. It is hoped that a more accurate proximity evaluation will be performed by applying a quantitative correction rate that considers rock and geological conditions, structure status, etc. to the proximity evaluation standard.

A Numerical Analysis on the Collapse and Backfill Mechanism of the Abandoned Mine Cavity (폐광의 점진적 파괴 및 뒷채움 효과에 대한 해석적 연구)

  • Lee, Jun-Suk;Bang, C.S.
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.2 no.2
    • /
    • pp.62-71
    • /
    • 2000
  • The abandoned mines causing settlement of the surface above and collapse of the cavities are the major influencing factor on the stability of the nearby underground structures. To prevent the harmful effect, the backfill methods are commonly applied to the cavities although the design criteria and the analysis method are not properly addressed in some cases. An approximate analytical method together with the numerical technique is considered in this study to simulate the gradual deterioration of the rock masses around the cavities and, therefore, the influential zone to the underground structures passing through the cavities. Also considered in this study is the backfill effect on the stability of the rock masses around the cavities. Specifically, the incomplete backfill effect is compared with that of the idealized backfill method by adopting elasto-plastic analysis involving a strain softening material law.

  • PDF

Fabrication and Stability of Pd Coated Ta/YSZ Cermet Membrane for Hydrogen Separation (Pd 코팅된 Ta/YSZ 수소분리막의 제조 및 안정성)

  • Lee, Sang-Jin;Jeon, Sung-Il;Park, Jung-Hoon
    • Membrane Journal
    • /
    • v.20 no.1
    • /
    • pp.69-75
    • /
    • 2010
  • Cermet membrane was fabricated with tantalum as hydrogen-permeable metal and $Y_2O_3$-stabilized $ZrO_2$ (YSZ) as ceramic supporter. Ta/YSZ cermet membrane was prepared through pre-sintering in He atmosphere and then main sintering under high vacuum and the impurities to originate from sintering and brazing could be removed by mechanical polishing. As-prepared membrane showed dense structure with continuous channel of tantalum. Hydrogen permeation experiment was conducted in the region of $200{\sim}350^{\circ}C$ using Ta/YSZ membrane coated with Pd for hydrogen dissociation. The crack in membrane was formed at $300^{\circ}C$ and the Pd coating layer has flaked off in spots. XRD results showed that tantalum reacted with hydrogen to form $Ta_2H$. The lattice expansion by $Ta_2H$ caused deterioration for membrane.