• Title/Summary/Keyword: stability measure

Search Result 855, Processing Time 0.023 seconds

Controller Design and Stability Analysis of Affine System with Dead-Time (불감시간을 갖는 Affine 시스템의 안정도 해석과 제어기 설계)

  • Yang Hai-Won;Byun Hwang-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.2
    • /
    • pp.93-102
    • /
    • 2005
  • The Nyquist robust stability margin is proposed as a measure of robust stability for systems with Affine TFM(Transfer Function Matrix) parametric uncertainty. The parametric uncertainty is modeled through a Affine TFM MIMO (Multi-Input Multi-Output) description with dead-time, and the unstructured uncertainty through a bounded perturbation of Affine polynomials. Gershgorin's theorem and concepts of diagonal dominance and GB(Gershgorin Bands) are extended to include model uncertainty. Multiloop PI/PID controllers can be tuned by using a modified version of the Ziegler-Nichols (ZN) relations. Consequently, this paper provides sufficient conditions for the robustness of Affine TFM MIMO uncertain systems with dead-time based on Rosenbrock's DNA. Simulation examples show the performance and efficiency of the proposed multiloop design method for Affine uncertain systems with dead-time.

Assessment of Stability and Safety of Maskne Cosmetic

  • Minjung, Kim;Jeonghee, Kim
    • Journal of Fashion Business
    • /
    • v.26 no.6
    • /
    • pp.105-115
    • /
    • 2022
  • Wearing a mask is still advised since COVID-19 continues to spread. However, masks may also irritate the skin and cause mask acne, often known as "maskne", which is a type of acne mechanica caused by friction between the skin and clothing. Therefore, there is a need to develop an effective maskne cosmetic. In this study, we made the maskne cosmetics containing humulus lupulus extract and copper tripeptide-1 and investigated its stability and safety. To measure stability, a centrifugation test and heat-cool cycling were done, and changes in viscosity and pH were measured for 8 weeks. The Cumulative Irritation Test (CIT, WKIRB-202111-HR-096) was performed and positive reactions were determined by the ICDRG criteria. The results indicated that the samples were stable after centrifugation, temperature cycling, viscosity, and pH tests. In addition, cosmetic safety test results revealed that maskne cosmetics containing humulus lupulus extract and copper tripeptide-1 did not cause any skin responses. These findings indicate that prepared maskne cosmetics' stability and safety were comparable to those of currently available commercial cosmetics.

Evaluation of the stability of sandblasted, large-grit, acid-etched implants with tapered straight body design (테이퍼드 직선형 SLA 임플란트의 안정성 평가)

  • Kim, Yong-Gun;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.80-88
    • /
    • 2018
  • Purpose: Implant surface modification and implant design are the principle targets for achieving successful primary stability. The aim of this study was to measure implant stability quotient (ISQ) values of sandblasted, large-grit, acid-etched (SLA) implants with tapered straight body design during the healing period, and to determine the various factors affecting implant stability. Materials and Methods: To measure implant stability, resonance frequency analysis (RFA) was performed in 26 patients (13 women and 13 men) with 44 SLA implants with tapered straight body design. Implant stability (ISQ values) was evaluated at baseline and healing abutment connection (12 weeks), and the correlations between RFA and insertion torque (IT), bone quality, and jawbone were determined. Results: The mean ISQ value of the implants was $69.4{\pm}10.2$ at the time of implant placement (baseline) and $81.4{\pm}6.9$ at the time of healing abutment connection (P < 0.05). Significant differences were found between RFA and bone quality and between RFA and jawbone (P < 0.05). No significant differences were found between RFA and IT, insertion area, fixture diameter, and implant length (P > 0.05). Conclusion: ISQ values of SLA implants with tapered straight body design were high at baseline and healing abutment connection. It was concluded that SLA implants with tapered straight body design show improved primary and secondary stability, and that immediate or early loading may be applicable.

Transient Stability assessment in the real power system using Energy Function. (에너지함수를 이용한 실계통에의 과도 안정도 평가 적용)

  • Kwon, Tae-Won;Lee, Kyung-Jae;Lee, Byung-Ha;Ham, Wan-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.153-156
    • /
    • 1992
  • Transient stability analysis of Korea Electric power Corporation(KEPCO) system is conducted by time simulation method, and the method is robust and reliable. But, time simulation consumes enormous computing resources and engineering time, and it does not provide a measure of the degree of stability of the system. Therefore, this method does not apply to every changed condition appropriately and quickly in planning and operating. And Transient Energy Function (TEF) method whis can assess quickly and quantatively the degree of stability of the system and which judges the stability and the instability to analyse transient dynamic charater of the system by mutual changing kinetic energy and potential energy, is developed. TEF method analyses the first Swing transient stability of the system by using the thought that if after disturbance happening, the increase of all the rotator kinetic energy changes into the potential energy after diturbance clearing, the system is stable, otherwise the system is unstable. This paper represents the availabiIity of the TEF method by comparing with time simulation method on the two cases.

  • PDF

An Overview of Flutter Prediction in Tests Based on Stability Criteria in Discrete-Time Domain

  • Matsuzaki, Yuji
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.12 no.4
    • /
    • pp.305-317
    • /
    • 2011
  • This paper presents an overview on flutter boundary prediction in tests which is principally based on a system stability measure, named Jury's stability criterion, defined in the discrete-time domain, accompanied with the use of autoregressive moving-average (AR-MA) representation of a sampled sequence of wing responses excited by continuous air turbulences. Stability parameters applicable to two-, three- and multi-mode systems, that is, the flutter margin for discrete-time systems derived from Jury's criterion are also described. Actual applications of these measures to flutter tests performed in subsonic, transonic and supersonic wind tunnels, not only stationary flutter tests but also a nonstationary one in which the dynamic pressure increased in a fixed rate, are presented. An extension of the concept of nonstationary process approach to an analysis of flutter prediction of a morphing wing for which the instability takes place during the process of structural morphing will also be mentioned. Another extension of analytical approach to a multi-mode aeroelastic system is presented, too. Comparisons between the prediction based on the digital techniques mentioned above and the traditional damping method are given. A future possible application of the system stability approach to flight test will be finally discussed.

Effects of Kinesio Taping and Massage Application to Calf Muscle on Ankle Stability

  • Kim, Chan-Woo;Roh, Hyo-Lyun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.4
    • /
    • pp.35-42
    • /
    • 2018
  • PURPOSE: This study was conducted to investigate the effects of Kinesio taping and massage application to the calf muscles on ankle stability. METHODS: The study subjects were 66 healthy adults (male: 32, female: 34) who had no instability in their ankles. Subjects were randomly assigned to a Kinesio taping group or a massage group. The research tool used the Y-balance test to measure instability of the ankle. The distance between the right and left foot was measured from the center in the anterior, posterior-medial, and posterior-lateral directions. Massage was applied to the calf muscles three times over two weeks and Kinesio tape was attached to the calf muscle and tibialis anterior for 10 hours twice during the experimental period. RESULTS: The results showed that application of Kinesio taping resulted in increases in the distance between the feet increased in some directions. After the massage, the distance extended from the anterior and posterior-lateral directions was prolonged, and the ankle stability on the right and left sides was partially improved by massage application. CONCLUSION: Kinesio taping and massage applied to the calf muscles are appropriate interventions for the improvement of ankle stability. Based on the application times of massage, Kinesio taping appears to work more effectively for ankle stability.

The Effect of Progressive Lumbar Stability Exercise on the Transversus Abdominis Muscle Thickness and Lower extremity muscle Fatigue Index in Soccer Players (축구선수의 진행형 요부안정화운동이 복횡근 두께와 하지근육 피로지수에 미치는 영향)

  • Lee, Joon-Hee;Park, Seung-Kyu;Kang, Jeong-Il;Yang, Dae-Jung;Kim, Je-Ho;Jeong, Yong-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.3
    • /
    • pp.349-356
    • /
    • 2012
  • This study aimed to assess the effects of progressive lumbar stability exercises and lumbar stability exercises on changes in the transversus abdominis muscle thickness and lower extremity muscle fatigue index in soccer players. Ten subjects were assigned to undergo training in each of the 2 groups, namely, the progressive lumbar stability exercise group and lumbar stability exercise group. Each intervention session lasted for 30 min, and 4 sessions were conducted in a week for 6 weeks for soccer players of S. University in Jeonnam, Korea. Changes in the transversus abdominis muscle thickness and lower extremity muscle fatigue index were measured using ultrasound and surface electromyogram. The results of the ultrasound measurement for the transversus abdominis muscle thickness indicated that progressive lumbar stability exercises were more effective than lumbar stability exercises. The results of the lower extremity muscle fatigue index measurements using surface electromyogram indicated that the fatigue index decreased in the progressive lumbar stability exercise group. Progressive lumbar stability exercise is believed to have put more workload during the shaking of the limbs, leading to increased stability and increased efficiency of the lower extremity muscle, thereby decreasing the fatigue index. Therefore, progressive lumbar stability exercises can be an effective measure for preventing injuries and improving the game performance of sports players by increasing the transversus abdominis muscle thickness and decreasing the lower extremity muscle fatigue index.

Large deformation modeling of flexible manipulators to determine allowable load

  • Esfandiar, Habib;Korayem, Moharam H.;Haghpanahi, Mohammad
    • Structural Engineering and Mechanics
    • /
    • v.62 no.5
    • /
    • pp.619-629
    • /
    • 2017
  • This paper focuses on the study of complete dynamic modeling and maximum dynamic load carrying capacity computation of N-flexible links and N-flexible joints mobile manipulator undergoing large deformation. Nonlinear dynamic analysis relies on the Timoshenko theory of beams. In order to model the system completely and precisely, structural and joint flexibility, nonlinear strain-displacement relationship, payload, and non-holonomic constraints will be considered to. A finite element solution method based on mixed method is applied to model the shear deformation. This procedure is considerably more involved than displacement based element and shear deformation can be readily included without inducing the shear locking in the element. Another goal of this paper is to present a computational procedure for determination of the maximum dynamic load of geometrically nonlinear manipulators with structural and joint flexibility. An effective measure named as Moment-Height Stability (MHS) measure is applied to consider the dynamic stability of a wheeled mobile manipulator. Simulations are performed for mobile base manipulator with two flexible links and joints. The results represent that dynamic stability constraint is sensitive when calculating the maximum carrying load. Furthermore, by changing the trajectory of end effector, allowable load also changes. The effect of torsional spring parameter on the joint deformation is investigated in a parametric sensitivity study. The findings show that, by the increase of torsional stiffness, the behavior of system approaches to a system with rigid joints and allowable load of robot is also enhanced. A comparison is also made between the results obtained from small and large deformation models. Fluctuation range in obtained figures for angular displacement of links and end effector path is bigger for large deformation model. Experimental results are also provided to validate the theoretical model and these have good agreement with the simulated results.

Concurrent Validity and Test-retest Reliability of the Core Stability Test Using Ultrasound Imaging and Electromyography Measurements

  • Yoo, Seungju;Lee, Nam-Gi;Park, Chanhee;You, Joshua (Sung) Hyun
    • Physical Therapy Korea
    • /
    • v.28 no.3
    • /
    • pp.186-193
    • /
    • 2021
  • Background: While the formal test has been used to provide a quantitative measurement of core stability, studies have reported inconsistent results regarding its test-retest and intraobserver reliabilities. Furthermore, the validity of the formal test has never been established. Objects: This study aimed to establish the concurrent validity and test-retest reliability of the formal test. Methods: Twenty-two young adults with and without core instability (23.1 ± 2.0 years) were recruited. Concurrent validity was determined by comparing the muscle thickness changes of the external oblique, internal oblique, and transverse abdominal muscle to changes in core stability pressure during the formal test using ultrasound (US) imaging and pressure biofeedback, respectively. For the test-retest reliability, muscle thickness and pressure changes were repeatedly measured approximately 24 hours apart. Electromyography (EMG) was used to monitor trunk muscle activity during the formal test. Results: The Pearson's correlation analysis showed an excellent correlation between transverse abdominal thickness and pressure biofeedback unit (PBU) pressure as well as internal oblique thickness and PBU pressure, ranging from r = 0.856-0.980, p < 0.05. The test-retest reliability was good, intraclass correlation coefficient (ICC1,2) = 0.876 for the core stability pressure measure and ICC1,2 = 0.939 to 0.989 for the abdominal muscle thickness measure. Conclusion: Our results provide clinical evidence that the formal test is valid and reliable, when concurrently incorporated into EMG and US measurements.

The influence of bone graft procedures on primary stability and bone change of implants placed in fresh extraction sockets

  • Jun, Sang Ho;Park, Chang-Joo;Hwang, Suk-Hyun;Lee, Youn Ki;Zhou, Cong;Jang, Hyon-Seok;Ryu, Jae-Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.8.1-8.6
    • /
    • 2018
  • Background: This study was to evaluate the effect of bone graft procedure on the primary stability of implants installed in fresh sockets and assess the vertical alteration of peri-implant bone radiographically. Methods: Twenty-three implants were inserted in 18 patients immediately after tooth extraction. The horizontal gap between the implant and bony walls of the extraction socket was grafted with xenografts. The implant stability before and after graft procedure was measured by Osstell Mentor as implant stability quotient before bone graft (ISQ bbg) and implant stability quotient after bone graft (ISQ abg). Peri-apical radiographs were taken to measure peri-implant bone change immediately after implant surgery and 12 months after implant placement. Data were analyzed by independent t test; the relationships between stability parameters (insertion torque value (ITV), ISQ abg, and ISQ bbg) and peri-implant bone changes were analyzed according to Pearson correlation coefficients. Results: The increase of ISQ in low primary stability group (LPSG) was 6.87 ± 3.62, which was significantly higher than the increase in high primary stability group (HPSG). A significant correlation between ITV and ISQ bbg (R = 0.606, P = 0.002) was found; however, age and peri-implant bone change were not found significantly related to implant stability parameters. It was presented that there were no significant peri-implant bone changes at 1 year after bone graft surgery. Conclusions: Bone graft procedure is beneficial for increasing the primary stability of immediately placed implants, especially when the ISQ of implants is below 65 and that bone grafts have some effects on peri-implant bone maintenance.