Development of the silver-white decoy for squid automatic jigging machine and fishing performance (오징어채낚기용 은백색 유인체 개발과 어획성능)

  • An, Young-Il;Jang, Ung-Jeong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.3
    • /
    • pp.208-217
    • /
    • 2013
  • Decoys for automatic jigging machines, the body part of a squid hook, have been developed in small and existing sizes in consideration of squid food, color blindness, and retinomotor responses and in utilization of pearl pigment, PP of high transparency, and combined mixture. In comparison of the developed silver-white decoy and existing decoys, the optical characteristics were examined, and the fishing performance of small size silver-white squid hooks was assessed in application of 4 fishing boats with the squid automatic jigging machine and metal halide fishing lamp in July, 2012. The luminances of the three squid hook colors-green, dark green and silver-white-increased as the intensity of illumination increased. Among these, the increase of silver-white was particularly distinguished. As to the average contrast of squid hooks, that of silver-white was 10.33, which was the highest, and then green 1.86 and dark green -0.10 in the order. As to the fishing performance of the silver-white hook, that of the 202 Geumyeong-ho and 101Yongjin-ho which caught squids were similar to that of the existing green hook and was relatively low in the case of the Dongbu-ho. However, that of the Haengbok-ho which caught relatively small squids whose average length was 19.9cm and installed silver-white hook in all automatic jigging machines was significantly excellent. In order to enhance the fishing performance of small size silver-white hooks, therefore, it would be effective to install in every automatic jigging machines of fishing boat and to start fishing before July by which small squids are caught.

Effect of Heating Condition, Additives and Solvents on Rheology of Squid Meat Paste Products (오징어 연제품의 물성 개선을 위한 탄력증강제 및 용매처리 효과)

  • 배태진;김해섭;최옥수
    • The Korean Journal of Food And Nutrition
    • /
    • v.16 no.2
    • /
    • pp.130-137
    • /
    • 2003
  • The squid had not been utilized for gel products because of its lower gel forming ability. The objectives of this study were as followed; 1) the optimum heating condition on squid meat paste products and 2) the optimum added level for jelly strength of squid meat paste products. Optimum heating conditions of squid meat kamaboko were as followed; setting(pre-heating) at 15$^{\circ}C$ or 55$^{\circ}C$ for 2 hours and heating at 9$0^{\circ}C$ for 60 minutes. The additives examined were as follows; 20mM EDTA, 10mM PMSF, 5 $\mu$mol/100g TGase, 0.2% potassium bromate, 2% collagen, 2% sucrose ester of stearic acid and 1% egg shell powder. The effects of additives on jelly strength were observed as follow, in descending order; 10mM of PMSF>5 $\mu$mo1/100g of TGase>0.2% of potassium bromate>20mM of EDTA. But sucrose ester of stearic acid and 1% egg shell powder were no effect. The solvents examined were as follows; n-amyl alcohol, n-butyl alcohol, n-hexyl alcohol, ethyl alcohol, ethylene glycol, propylene glycol and glycerin glycol. It showed that high jelly strength as 787gㆍcm for 3% of n-butyl alcohol and 749gㆍcm for 3% of n-amyl alcohol. To adding 5% of n-butyl alcohol and n-amyl alcohol, gave the highest jelly strength and water holding capacity(WHC). Effect of alcohol on jelly strength appeared higher value at added 5% of n-butyl alcohol than n-amyl alcohol, and flying squid product was higher than jumbo squid product.

Design of a 40 channel SQUID system (40채널 SQUID 시스템의 설계)

  • Lee, Y.H.;Kim, J.M.;Kwon, H.C.;Lim, C.M.;Lee, S.K.;Park, Y.K.;Park, J.C.;Lee, D.H.;Shin, J.K.;Ahn, C.B.;Park, M.S.;Hur, Y.;Hong, J.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.191-192
    • /
    • 1998
  • We report on the design of a low-noise 40 channel SQUID system for biomagnetism. We used low-noise SQUID sensor with the pickup coil integrated on the same wafer as the SQUID. The SQUID electronics were simplified by increasing the voltage output of the SQUID. The SQUID insert was designed to have low thermal load, minimizing the liquid helium loss. The digital signal processing provides versatile analysis tools and the software is based on the object-oriented programming. For the effective localization of the source location, solutions of the inverse problems based on the lead-field and the simulated anneal ins were studied.

  • PDF

Effect of Electron Beam Irradiation on the Microbial Safety and Qualities of Sliced Dried Squid (전자선 조사가 건조 오징어의 미생물학적 안정성 및 품질에 미치는 영향)

  • Ko, Jong-kwan;Ma, Yu-hyun;Song, Kyung-Bin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.3
    • /
    • pp.433-437
    • /
    • 2005
  • Electron beam irradiation was applied to examine the microbial safety and qualities of sliced dried squid. Sliced dried squid was irradiated at dose of 2, 4, 8, 12, and 16 kGy. Microorganisms contaminated in sliced dried squid were significantly decreased by irradiation. Decimal reduction dose (D/sub 10/ value) of total bacteria count, yeast and mold, coliforms in sliced dried squid were 8.57, 4.60, and 8.10 kGy, respectively. Electron beam irradiation caused negligible changes in Hunter color L, a, and b value. Sensory evaluations of irradiated sliced dried squid showed that there were no significant changes among the samples. These results indicate that electron beam irradiation improves the microbial safety and qualities of sliced dried squid.

Sequences and Phylogenic Analysis of Squid New Kinesin Superfamily Proteins (KIFs) (오징어과의 Kinesin Superfamily Proteins (KIFs)의 유전자분석 및 계통분석)

  • Kim, Sang-Jin;Seog, Dae-Hyun
    • Journal of Life Science
    • /
    • v.22 no.3
    • /
    • pp.293-297
    • /
    • 2012
  • The movement of vesicles from the neuronal cell body to specific destinations requires molecular motors. The squid giant axon represents a powerful model for studies of the axonal transport mechanism because the axoplasm can readily be separated from the sheath by simple extrusion. In a previous study, vesicular movements in the axoplasm of the squid giant axon were inhibited by the kinesin antibody. In the present study, we cloned and sequenced the cDNAs for squid brain KIFs. Amplification of the conserved nucleotide sequences of the motor domain by polymerase chain reaction (PCR) using first-strand cDNAs of the squid optic lobe identified six new KIF proteins. Motif analysis of the motor domains revealed that the squid KIFs are homologous to the consensus sequences of the mouse KIFs. The phylogenetic tree generated by using the maximum parsimony (MP) method, the neighbor-joining (NJ) method, the minimum evolution (ME) method, and the maximum likelihood (ML) method showed that squid KIFs are closest to mouse KIFs. These data prove the phylogenetic relationships between squid KIFs and mouse ones.

Emulator Circuit for a Flux Locked Loop for Detection of Magnetocardiography Signal (심자도 신호 검출을 위한 Flux Locked Loop (FLL) Emulation 회로)

  • 안창범;이동훈;김인기;장경섭;김기태;정동현;최중필
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2749-2752
    • /
    • 2003
  • Magnetocardiography is a very weak biomagnetic field generated from the heart. Since the magnitude of the biomagnetic field is in the order of a few pico Tesla, it is measured with a superconducting quantum interference device (SQUID). SQUID is a transducer converting magnetic flux to voltage, however, its range of linear conversion is very restricted. In order to overcome the narrow dynamic range. a flux locked loop is used to feedback the output field with opposite polarity to the input field so that the total Held becomes zero. This prevents the operating point of the SQUID from moving too far away from the null point thereby escape from the linear region. In this paper, an emulator for the SQUID sensor and feedback coil is proposed. Magnetic courting between the original field and the generated field by the feedback coil is emulated by electronic circuits. By using the emulator, FLL circuits are analyzed and optimized without SQUID sensors. The emulator may be used as a test signal for multi-channel gain calibration and system maintenance.

  • PDF

Measurement of weak magnetic signals using high-$T_c$ SQUID magnetometers in magnetically disturbed environment (High-$T_c$ SQUID 자력계를 이용한 자기잡음 환경에서의 미세자기신호 측정 및 분석)

  • 김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.121-126
    • /
    • 2003
  • The single layer direct-coupled YBCO SQUID magnetometers have been fabricated and characterized for the purpose of the measurement of weak magnetic signals in unshielded environment. Two types of magnetometers have been designed and fabricated using 10 mm$\times$ 10 mm substrates. We could operate the conventional 3-mm-wide solid pickup loop magnetometers more stably than the 12-parallel-line pickup loop magnetometers in laboratory environment. We developed a first-order electronic gradiometer system using the SQUID sensors with axial displacement of 80 mm without any mechanical alignment of magnetometers. The system with a software filter using calculation of discrete Fourier transform could record clearly weak pulse signal of 100 pT in a magnetically disturbed environment.

  • PDF

Direct-coupled First-order SQUID gradiometer for Nondestructive Evaluations (비파괴 평가용 직접결합형 1차 미분형 SQUID gradiometer)

  • Hwang, Yun-Seok;Choi, Hee-Seok;Kim, Jin-Tae;Lee, Soon-Gul;Lee, Dong-Hoon;Park, Yong-Ki;Park, Jong-Chul
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.161-164
    • /
    • 1999
  • We have fabricated the direct-coupled planar type 1st-order SQUID gradiometers. The gradiometer consists of moats or slots in SQUID loop. It is made by YBa$_2Cu_3O_7$ thin films using pulsed laser deposition method on SrTiO$_3$ single crystal and bi-crystal substrates. We have studied the effects of slots and moats in SQUID loop by measuring the voltage modulation signals under uniform field and 1st-order gradient, and the noise properties under non-shielded environment.

  • PDF

Nondestmctive Evaluation of Cracks in Metal Plates by using SQUID Gradiometer

  • 황윤석;김진태;이순걸;박용기
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.159-162
    • /
    • 2002
  • We have detected cracks inside multi-layer metal sheets with nondestructive evaluation system consisting of SQUID gradiometer. Double D-shape coil was carefully designed with computer simulation for spatial distribution of magnetic field. It was aligned and placed in between SQUID and metal sheets in order to reduce the field effect to SQUID and to maximize eddy current in the sheets. The metal plate in bottom of the metal stack contained artificial cracks which were scanned by an X-Y scanning system. The information of crack position and size could be estimated by analysis of SQUID signal. Details of the results will be discussed .

  • PDF

Noise Properties of Directly-coupled Single-layer High-Tc 2nd-order SQUID Gradiometer

  • 황윤석;안종록;강찬석;이순걸;김진태
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.163-167
    • /
    • 2002
  • We have fabricated planar-type single-layer second-order high-Tc SQUID gradiometers. The devices consisted of symmetrically designed three parallel-connected square pickup loops that were directly coupled to the SQUID. $YBa_2$$Cu_3$$O_{7}$ film was deposited on $SrTiO_3$ substrate by a PLD system and patterned into a device by the photolithography with ion milling technique. Junctions of the SQUID were either step-edge or bicrystal type. All the structures were formed on a 10 mm $\times$ 5 mm substrate. Balancing of the gradiometer was achieved by adjusting the width of the central pickup loop. The gradiometer noise was measured both inside and outside a magnetically shielded room. Details of the results will be discussed.

  • PDF