• Title/Summary/Keyword: square root function

Search Result 243, Processing Time 0.021 seconds

An Algorithm for Optimized Accuracy Calculation of Hull Block Assembly (선박 블록 조립 후 최적 정도 계산을 위한 알고리즘 연구)

  • Noh, Jac-Kyou
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.5
    • /
    • pp.552-560
    • /
    • 2013
  • In this paper, an optimization algorithm for the block assembly accuracy control assessment is proposed with consideration for the current block assembly process and accuracy control procedure used in the shipbuilding site. The objective function of the proposed algorithm consists of root mean square error of the distances between design and measured data of the other control points with respect to a specific point of the whole control points. The control points are divided into two groups: points on the control line and the other points. The grouped data are used as criteria for determining the combination of 6 degrees of freedom in the registration process when constituting constraints and calculating objective function. The optimization algorithm is developed by using combination of the sampling method and the point to point relation based modified ICP algorithm which has an allowable error check procedure that makes sure that error between design and measured point is under allowable error. According to the results from the application of the proposed algorithm with the design and measured data of two blocks data which are verified and validated by an expert in the shipbuilding site, it implies that the choice of whole control points as target points for the accuracy calculation shows better results than that of the control points on the control line as target points for the accuracy of the calculation and the best optimized result can be acquired from the accuracy calculation with a fixed point on the control line as the reference point of the registration.

Development of a predictive model describing the growth of Staphylococcus aureus in processed meat product galbitang (식육추출가공품 중 갈비탕에서의 Staphylococcus aureus 성장예측모델 개발)

  • Son, Na-Ry;Kim, An-Na;Choi, Won-Seok;Yoon, Sang-Hyun;Suh, Soo-Hwan;Joo, In-Sun;Kim, Soon-Han;Kwak, Hyo-Sun;Cho, Joon-Il
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.3
    • /
    • pp.274-278
    • /
    • 2017
  • In this study, predictive mathematical models were developed to estimate the kinetics of Staphylococcus aureus growth in processed meat product galbitang. Processed meat product galbitang was inoculated with 0.1 mL of S. aureus culture and stored at 4, 10, 20, $37^{\circ}C$. The ${\mu}_{max}$ (maximum specific growth rate) and LPD (lag phase duration) values were calculated. The primary model was used to develop a response surface secondary model. The growth parameters were analyzed using the square root model as a function of storage temperature. The developed model was confirmed by calculating RMSE (Root Mean Square Error) values as statistic parameters. The LPD decreased, but ${\mu}_{max}$ increased with an increase in the storage temperature. At 4, 10, 20 and $37^{\circ}C$, $R^2$ was 0.99, 0.98, 0.99 and 0.99, respectively; RMSE was 0.39. The developed predictive growth model can be used to predict the risk of S. aureus contamination in processed meat product galbitang; hence, it has potential as an input model for the risk assessment.

A Reflectance Normalization Via BRDF Model for the Korean Vegetation using MODIS 250m Data (한반도 식생에 대한 MODIS 250m 자료의 BRDF 효과에 대한 반사도 정규화)

  • Yeom, Jong-Min;Han, Kyung-Soo;Kim, Young-Seup
    • Korean Journal of Remote Sensing
    • /
    • v.21 no.6
    • /
    • pp.445-456
    • /
    • 2005
  • The land surface parameters should be determined with sufficient accuracy, because these play an important role in climate change near the ground. As the surface reflectance presents strong anisotropy, off-nadir viewing results a strong dependency of observations on the Sun - target - sensor geometry. They contribute to the random noise which is produced by surface angular effects. The principal objective of the study is to provide a database of accurate surface reflectance eliminated the angular effects from MODIS 250m reflective channel data over Korea. The MODIS (Moderate Resolution Imaging Spectroradiometer) sensor has provided visible and near infrared channel reflectance at 250m resolution on a daily basis. The successive analytic processing steps were firstly performed on a per-pixel basis to remove cloudy pixels. And for the geometric distortion, the correction process were performed by the nearest neighbor resampling using 2nd-order polynomial obtained from the geolocation information of MODIS Data set. In order to correct the surface anisotropy effects, this paper attempted the semiempirical kernel-driven Bi- directional Reflectance Distribution Function(BRDF) model. The algorithm yields an inversion of the kernel-driven model to the angular components, such as viewing zenith angle, solar zenith angle, viewing azimuth angle, solar azimuth angle from reflectance observed by satellite. First we consider sets of the model observations comprised with a 31-day period to perform the BRDF model. In the next step, Nadir view reflectance normalization is carried out through the modification of the angular components, separated by BRDF model for each spectral band and each pixel. Modeled reflectance values show a good agreement with measured reflectance values and their RMSE(Root Mean Square Error) was totally about 0.01(maximum=0.03). Finally, we provide a normalized surface reflectance database consisted of 36 images for 2001 over Korea.

Reproducibility of Gated Myocardial Perfusion SPECT for the Assessment of Myocardial Function: Comparison with Thallium-201 and Technetium-99m-MIBI (심근 기능 측정에 사용된 게이트 심근 관류 SPECT 방법의 재현성 평가: $^{201}Tl$$^{99m}Tc$-MIBI 게이트 SPECT의 비교)

  • Hyun, In-Young;Seo, Jeong-Kee;Hong, Eui-Soo;Kim, Dae-Hyuk;Kim, Sung-Eun;Kwan, Jun;Park, Keum-Soo;Choe, Won-Sick;Lee, Woo-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.381-392
    • /
    • 2000
  • Purpose: We compared the reproducibility of $^{201}Tl\;and\;^{99m}Tc$-sestamibi (MIBI) gated SPECT measurement of myocardial function using the Germano algorithm Materials and Methods: Gated SPECT acquisition was repeated in the same position in 30 patients who received $^{201}Tl$ and in 26 who received $^{99m}Tc$-MIBI. The quantification of end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) on $^{201}Tl\;and\;^{99m}Tc$-MIBI gated SPECT was processed independently using Cedars quantitative gated SPECT software. The reproducibility of the assessment of myocardial function on $^{201}Tl$ gated SPECT was compared with that of $^{99m}Tc$-MIBI gated SPECT Results: Correlation between the two measurements for volumes and EF was excellent by the repeated gated SPECT studies of $^{201}Tl$ (r=0.928 to 0.986; p<0.05) and $^{99m}Tc$-MIBI (r=0.979 to 0.997; p<0.05). However, Bland Altman analysis revealed the 95% limits of agreement (2 SD) for volumes and EF were tighter by repeated $^{99m}Tc$-MIBI gated SPECT (EDV: 14.1 ml, ESV: 9.4 ml and EF: 5.5%) than by repeated $^{201}Tl$ gated SPECT (EDV: 24.1 ml, ESV: 18.6 ml and EF: 10.3%). The root mean square (RMS) values of the coefficient of variation (CV) for volumes und EFs were smaller by repeated $^{99m}Tc$-MIBI gated SPECT (EDV: 2.1 ml, ESV 2.7 ml and EF: 2.3%) than by repeated $^{201}Tl$ gated SPECT (EDV: 3.2 ml, ESV: 3.5 ml and EF: 5.2%). Conclusion: $^{99m}Tc$-MIBI provides more reproducible volumes and EF than $^{201}Tl$ on repeated acquisition gated SPECT. $^{99m}Tc$-MIBI gated SPECT is the preferable method for the clinical monitoring of myocardial function.

  • PDF

Study on the Radial Pulse Wave Variables and Heart Rate Variability after Acupuncture Stimulation (침자극이 좌관맥상과 심박수 미세변화에 미치는 영향)

  • Won, Jae-Kyun;Jung, Soon-Kwan;Kim, Dong-Eun;Lim, Jin-Young;Kwon, Young-Dal;Yeom, Seung-Ryong;Lee, Su-Kyung;Song, Yung-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.237-244
    • /
    • 2009
  • We investigated the effects of acupuncture stimulation on pulse wave variables and heart rate variability (HRV) in healthy adults. To evaluate twenty healthy volunteers (10 men, 10 women) had acupuncture into both Hapkok (Ll4) and Taechung (Liv3) for 15 minutes. Radial pulse, Heart Rate Variability, body temperature and blood pressure were checked before and after acupuncture to evaluate Pulse Wave Variability and Autonomous Function. The results were as follows; Heart rate was significantly increased while systolic blood pressure (mmHg) and diastolic blood pressure (mmHg) were significantly increased after acupuncture treatment. Sixteen subjects didn't change representative pulse wave variables after acupuncture treatment. Energy, height of main peak (H1), height of pre-dicrotic valley (H2) and height of descending valley (H4) were decreased while height of dicrotic peak (H5) was significantly decreased after acupuncture treatment. Time to main peak (T1), time to pre-dicrotic valley (T2), time to dicrotic peak (T5), total time (T) and T-T4 were decreased while time to descending valley (T4) was increased after acupuncture treatment. Total area (At), area of main peak (Aw) and ratio of diastolic period area (Ad) were decreased while ratio of systolic period area (As) and angle of main peak (MPA) were increased after acupuncture treatment. The standard deviation of all normal RR intervals (SDNN) was increased while the root mean square of successive differences between the normal heart beats (RMSSD) was significantly increased after acupuncture treatment by time domain analysis. Low frequency power (LF) and LF/HF ratio were decreased while high frequency power (HF) was significantly increased after acupuncture treatment by frequency domain analysis. This study suggests that acupuncture treatment changes pulse wave variability and heart rate variability. Further study on various acupuncture treatment for pulse wave variability and heart rate variability is required.

Mass Transfer during Salting and Desalting Processes of Chinese Cabbage (배추의 염절임 및 탈염 공정중 물질이동)

  • Kim, Dong-Kwan;Kim, Myung-Hwan;Kim, Byung-Yong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.22 no.3
    • /
    • pp.317-322
    • /
    • 1993
  • The diffusion phenomena of water, solid and reducing sugar in Chinese cabbage during salting (5$0^{\circ}C$, 25% salt solution) and desalting (5$0^{\circ}C$, distilled water) were investigated. Water loss and solid gain during salting were rapid in the first 6hrs and then almost leveled off. After 24hrs of salting, water loss and solid gain in 100g of initial wet Chinese cabbage were 33.35g and 6.26g respectively. Moisture content was changed from 94.29% to 83.11% during 24hrs of salting. The reducing sugar concentration was also changed from 29.2 mg/$m\ell$ to 6.5mg/$m\ell$, which was linearized as a function of the square root of salting time and showing that Y=30.1841-5.0269√t. After 24hrs salting, water gain and solid loss during desalting were rapid in the first 4hrs and then increased linearly. After 12hrs of desalting, the water gain and solid loss in 100g of initial wet Chinese cabbage were 20.82g and 9.14g respectively. The amount of solid loss after 12hrs desalting was higher than that of solid gain after 24hrs salting due to the diffusion of solute presented initially in the Chinese cabbage during salting and desalting. The concentration of salt in Chinese cabbage after 12hrs desalting was 2.98% which was a suitable salt concentration for the preparation of Kimchi. At this time, the concentration of reducing sugar was only 1.6mg/$m\ell$. The linear regression equation of reducing sugar concentration during desalting was Y=6.7854-1.5992√t.

  • PDF

Development of a Hydrograph Triggered by Earth-Dam-Break for Compiling a Flood Hazard Map (홍수위험지도 작성을 위한 댐 붕괴 지점에서의 유량곡선 산정)

  • Lee, Khil-Ha;Kim, Sung-Wook;Yu, Soonyoung;Kim, Sang-Hyun;Cho, Jinwoo;Kim, Jin-Man
    • The Journal of Engineering Geology
    • /
    • v.23 no.4
    • /
    • pp.381-387
    • /
    • 2013
  • In compiling flood hazard maps for the case of dam-failure, a scenario-based numerical modeling approach is commonly used, involving the modeling of important parameters that capture peak discharge, such as breach formation and progress. In this study, an earth-dam-break model is constructed assuming an identical mechanism and hydraulic process for all dam-break processes. A focus of the analysis is estimation of the hydrograph at the outlet as a function of time. The constructed hydrograph then serves as an upper boundary condition in running the flood routing model downstream, although flood routing is not considered here. Validation was performed using the record of the Tangjishan dam-break in China. The results were satisfactory, with a coefficient of determination of 0.974, Nash-Sutcliffe Coefficient of Efficiency (NSC) of 0.94, and Root Mean Square Error (RMSE) of $610m^3/sec$. The proposed model will contribute to assessments of potential flood hazards caused by dam-break.

Comparative Study of Change in Salmonella Enteritidis and Salmonella Typhimurium Populations in Egg white and Yolk (난백과 난황에서 Salmonella Enteritidis 와 Salmonella Typhimurium 수 변화 비교연구)

  • Moon, Hye Jin;Lim, Jeong Gyu;Yoon, Ki Sun
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.342-348
    • /
    • 2016
  • The objective of this study was to compare the change of S. Enteritidis with S. Typhimurium populations in liquid egg products. S. Enteritidis or S. Typhimurium was inoculated into egg white and egg yolk and stored at 8, 10, 15, 25, and $35^{\circ}C$, respectively. In egg white, no growth of S. Enteritidis and S. Typhimurium was observed at 8, 10, 15, and $35^{\circ}C$, while both S. Enteritidis and S. Typhimurium in egg white stored grew more than 1 log CFU/ml after 50 hours storage at $25^{\circ}C$. In egg yolk, there was no growth of S. Enteritidis and S. Typhimurium at $8^{\circ}C$ but growth of both strains was observed at 10, 15, 25, and $35^{\circ}C$. Since growth of S. Enteritidis and S. Typhimurium was only observed in egg yolk, primary growth models for both strains were developed using modified Gompertz equation and then secondary models for lag time (LT), specific growth rate (SGR), and maximum population density (MPD) were developed as a function of temperature. At all temperatures, more rapid growth of S. Enteritidis than S. Typhimurium was observed in egg yolk, indicating the greater risk of S. Enteritidis than S. Typhimurium in egg products. In conclusion, the results indicate that temperature control less than $8^{\circ}C$ is very important to ensure safety of liquid egg products, especially liquid egg yolk.

Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image (디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.275-283
    • /
    • 2013
  • The patient radiation dose is different depending on selection of Ion chamber when taking Chest PA which using AEC. In this paper, we studied acquiring the best diagnostic images according to selection of Ion chamber on AEC mode as well as minimizing patient radiation dose. Experimental methods were selection of Ion chamber and change of sensitivity under the same conditions as Chest PA projection. At AEC mode, two upper ion chambers sensors and one lower ion chamber sensor were divided into 7 cases according to selection of on/off. after measuring five times respectively, we obtained average value and calculated exposure dose. Image assessment was done with measured Modulation Transfer Function, Peak Signal to Noise Ratio, Root Mean Square, Signal to Noise Ratio, Contrast to Noise Ratio, Mean to Standard deviation Ratio respectively. In exposure assessment results, selection of two upper chambers was the lowest. In resolution assessment results, image of two upper chambers had the second high spatial frequency at sensitivity at 625(High) was 1.343 lp/mm. RMS value of image selecting two upper chambers was low secondly. SNR, CNR, MSR were the high value secondly. As the sensitivity was increased, radiation dose was decreased but better image could be obtained on image quality. In order to obtain the best medical images while minimizing the dose, usage of two upper ion chambers is considered to be clinically useful at sensitivity 625(High).

Performance Improvement of Near Earth Space Survey (NESS) Wide-Field Telescope (NESS-2) Optics

  • Yu, Sung-Yeol;Yi, Hyun-Su;Lee, Jae-Hyeob;Yim, Hong-Suh;Choi, Young-Jun;Yang, Ho-Soon;Lee, Yun-Woo;Moon, Hong-Kyu;Byun, Yong-Ik;Han, Won-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.2
    • /
    • pp.153-160
    • /
    • 2010
  • We modified the optical system of 500 mm wide-field telescope of which point spread function showed an irregularity. The telescope has been operated for Near Earth Space Survey (NESS) located at Siding Spring Observatory (SSO) in Australia, and the optical system was brought back to Korea in January 2008. After performing a numerical simulation with the tested value of surface figure error of the primary mirror using optical design program, we found that the surface figure error of the mirror should be fabricated less than root mean square (RMS) $\lambda$/10 in order to obtain a stellar full width at half maximum (FWHM) below $28\;{\mu}m$. However, we started to figure the mirror for the target value of RMS $\lambda$/20, because system surface figure error would be increased by the error induced by the optical axis adjustment, mirror cell installation, and others. The radius of curvature of the primary mirror was 1,946 mm after the correction. Its measured surface figure error was less than RMS $\lambda$/20 on the table of polishing machine, and RMS $\lambda$/15 after installation in the primary mirror cell. A test observation performed at Daeduk Observatory at Korea Astronomy and Space Science Institute by utilizing the exiting mount, and resulted in $39.8\;{\mu}m$ of stellar FWHM. It was larger than the value from numerical simulation, and showed wing-shaped stellar image. It turned out that the measured-curvature of the secondary mirror, 1,820 mm, was not the same as the designed one, 1,795.977 mm. We fabricated the secondary mirror to the designed value, and finally obtained a stellar FWHM of $27\;{\mu}m$ after re-installation of the optical system into SSO NESS Observatory in Australia.