• Title/Summary/Keyword: spraying

Search Result 1,333, Processing Time 0.025 seconds

Charging Characteristics of Electrostatic Sprayer Applied Square Pulse (구형파 펄스를 인가한 정전분무 장치의 대전량 특성)

  • 박승록;문재덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.573-578
    • /
    • 2003
  • In this study, new type of induction charging system for electrostatic spraying was manufactured and proposed to improve the electrical safety and charging efficiency. And parameters of proposed system to generate the maximum deposition current with electrical safety were selected and investigated. The selected parameters were frequency of square pulse and thickness of insulation material, outer diameter of device and thickness and positions of electrode. Charging quantity of water drop was measured by deposition current detected from sensing plate indirectly. The maximum deposition current for each parameter were 3.5[uA] at the frequency of 15[kHz] and thickness of 0.25[mm] insulating layer. And maximum deposition currents were 2.8[uA] and 3.0[uA] at 25[mm] outer diameter of charging device and 0.25[mm] thickness of electrode each. Effects of electrode position from spraying nozzle on deposition current was a little.

Microstructure and Bonding Strength of Tungsten Coating Deposited on Copper by Plasma Spraying

  • Song, Shu-Xiang;Zhou, Zhang-Jian;Du, Juan;Zhong, Zhi-Hong;Ge, Chang-Chun
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.511-512
    • /
    • 2006
  • Tungsten coatings with different interlayers onto the oxygen-free copper substrates were fabricated by atmosphere plasma spraying. The effects of different interlayers of NiCrAl, NiAl and W/Cu on bonding strength were studied. SEM, EDS and XRD were used to investigate the photographs and compositions of these coatings. The tungsten coatings with different initial particle sizes resulted in different microstructures. Oxidation was not detected in the tungsten coating, but in the interlayer, it was found by both XRD and EDS. The tungsten coating deposited directly onto the copper substrate presented higher bonding strength than those with different interlayers.

  • PDF

Improvement of Multiply Board Properties with Starch Spraying (전분 분무기술을 통한 다층지의 물성개선)

  • Lee, Hak-Lae;Ryu, Jeong-Yong
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.3
    • /
    • pp.12-23
    • /
    • 2007
  • Frequently spraying of natural starch slurry onto the formed wet web has been adopted to improve properties of paperboards. This conventional starch spraying technique, however, becomes less effective in strength improvement. In this study the effects of various factors including wet web dryness, quantity of starch slurry sprayed, and drying temperature on paperboard properties were investigated. Migration of starch granules into the webs appeared to cause a reduction in plybond strength when the web dryness was lower than this level. Wet webs should contain enough water to swell the starch granules, and at the same time they should be heated to a temperature high enough for complete cooking of the sprayed starches to occur. This suggested that preheating of the wet web can be employed to improve the plybond strength.

Comparison of different measuring methods for the determination of the particle size of powders for plasma spraying

  • 석한길
    • Proceedings of the KWS Conference
    • /
    • 2001.10a
    • /
    • pp.220-222
    • /
    • 2001
  • The average grain size, the grain-size distribution, the morphology and the microstructure are fundamental characteristics of a spraying powder. Now that the significance of the grain size for the pattern of properties of the powder has been recognised, greater consideration is also being given to it in standards and regulations. However, unfortunately, the processes according to which the grain size and the grain-size distribution must be determined are specified in the rarest of cases. The contribution therefore dealt with the comparison of different particle-size measuring techniques, such as diffraction spectroscopy, sedimentation, sieving and microscopic measurement. The comparability of the measured results was investigated on twelve plasma spraying powders with different compositions, nominal sizes and morphologies.

  • PDF

Electrochemical corrosion behavior of atmospheric-plasma-sprayed copper as a coating material for deep geological disposal canisters

  • Sung-Wook Kim;Gha-Young Kim;Young-Ho Lee;Jun-Hyuk Jang;Chung-Won Lee;Jeong-Hyun Woo;Seok Yoon
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4032-4038
    • /
    • 2023
  • Cu, which exhibits excellent corrosion resistance in underground environments, has been investigated as a canister material for use in the deep geological disposal of spent nuclear fuels. In this study, the technical viability of atmospheric plasma spraying for producing Cu-coated canisters was investigated. A high-purity Cu film (millimeter scale) was deposited onto a stainless-steel substrate using a plasma gun with a shroud structure. Potentiodynamic polarization studies revealed that the Cu film exhibited a sufficiently low corrosion rate in the groundwater electrolyte. In addition, no pitting corrosion was observed on the Cu film surface after accelerated corrosion studies. A prototype cylindrical Cu film was fabricated on a 1/20 scale on a stainless-steel tube to demonstrate the scalability of atmospheric plasma spraying in producing Cu-coated canisters.

Fabrication and Pore Properties of SUS316L Membrane with Double-Layered Pore Structures by Wet Powder Spraying

  • Min-Jeong Lee;Hyeon-Ju Kim;Manho Park;Jung-Yeul Yun
    • Archives of Metallurgy and Materials
    • /
    • v.67 no.4
    • /
    • pp.1531-1534
    • /
    • 2022
  • In this study, a SUS316L membrane having double layered pore structures was fabricated, and the pore characteristics were analyzed after coating with a spherical powder and a flake-shaped powder on a disk-shaped SUS316L support using a wet powder spraying process. The thickness of the coated layer was checked using an optical microscope, and air permeability was measured using a capillary flow porometer. When the coating amount was similar, the fine porous layer prepared using flake powder was thicker and showed higher porosity. In the case of a similar thickness, the case of using flake powder was half of the amount of spherical powder used. Therefore, it was confirmed that it is possible to manufacture a metal membrane having a high filter efficiency even with a small coating amount when using the flake powder.

A Study on the Case Analysis and Health Management of Patients with Pesticide Poisoning from Spraying Pesticide in Hospitals in the Chungnam, Korea (충남 일부 지역 병의원의 농약살포 중 중독 사례 분석 및 보건관리방안 연구)

  • Moon, Sun-In;Choi, Jihee;Roh, Sangchul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.4
    • /
    • pp.541-549
    • /
    • 2019
  • Objectives: This study aims to examine patients who developed acute pesticide poisoning while spraying or using pesticide and presented to the emergency department in hospitals in Chungcheongnam-do Province. Based on the findings, this study will provide implications for safety and health management pertaining to the use of pesticides. Methods: Pesticide poisoning data collected by the Chungnam Center for Farmers' Safety and Health from 2014 to 2018 was cross-sectionally analyzed. A total of 331 patients with pesticide poisoning presented to one of hospitals and four of medical centers in the region(Dankuk University Hospital, Gongju and Hongsung, Cheongyang, Cheonan Medical Center). Seventeen of these patients (15 men and two women) developed poisoning while spraying pesticide. The patients' charts were reviewed to collect data on pesticide poisoning, namely currently working in farming-related occupation, means of transportation to the hospital, place of poisoning, symptoms of acute pesticide poisoning, treatment, pesticide used when poisoning occurred, and classification by technical ingredients. Results: Fifteen out of 17 patients who developed poisoning while spraying pesticide were men. Insecticide was used in 35.3% of the cases, and herbicide was used in 29.4% of the cases, which was different from cases of poisoning from ingestion poisoning. The major symptoms were vomiting (35.3%), nausea (29.4%), dizziness (29.4%), and headache (23.5%). A total 11 ingredients were identified in 12 patients, and the most common ingredient was glyphosate, which is an herbicide. Most patients showed a state of mild toxicity, but two patients showed a state of severe toxicity. These patients respectively used glyphosate and paraquat. Conclusions: Our findings can be useful for suggesting the need for a national healthcare system to manage occupational pesticide poisoning among farmers. Further, these findings can be used to increase the awareness of the risk of acute poisoning during pesticide spraying and suggest the need for a safety health education to increase farmers' awareness of pesticide poisoning.

Pigment Distribution Analysis of High Speed Fan for Dusting Large Pasture at Livestock Farms (축산농가를 위한 대규모 목초지 방제용 고속 팬의 실험을 통한 색소 분포에 따른 분석)

  • Kim, C.S.;Min, B.R.;Seo, K.W.;Lee, D.W.
    • Journal of Animal Environmental Science
    • /
    • v.15 no.2
    • /
    • pp.99-106
    • /
    • 2009
  • We conducted a comparison experiment of our wide-area spraying high speed fan with a fan which was developed by Japan MARUYAMA Inc. have been much recognized for it's history and skills in a field of spraying machine. In result, MARUYAMA Inc. fan sprayed up to 120 m and, on the other hand, wide-area spraying high speed fan of our own making was able to spray up to more than 160 m. Wide-area spraying machine have been supplied to domestic demands by importing from Japan, but it is determined to be possible that home products will occupy market for it's ability, price and A/S environment in future. The main research results are below. Some plastic cups which are in the open market are used for our experiment. After distributing 90 cups in a range of 10m vertically with localizing 5 cups horizontally and 18 cups vertically, spraying machine was moved and finally we make distribution charts by estimating the sprayed amounts on each cup. Vertical distance was set up to 5m and we calculated average values by using sprayed amount and data of 4 observers. In result our fan showed much sprayed amounts than MARUYAMA Inc. all over the field except situations of vehicle departing and stopping.

  • PDF

Dissipation and Processing Factor of Etofenprox and Fenitrothion Residue in Chinese Matrimony Vine by drying (건조에 따른 구기자 중 etofenprox와 fenitrothion의 잔류량 변화 및 가공계수)

  • Noh, Hyun Ho;Lee, Jae Yun;Park, Hyo Kyoung;Jeong, Hye Rim;Lee, Jung Woo;Jo, Seung Hyeon;Kwon, Hyeyoung;Kyung, Kee Sung
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.3
    • /
    • pp.213-220
    • /
    • 2018
  • BACKGROUND: This study was carried out to determine characteristics of residual pesticides in time-dependent manner and calculate half-lives of the residual pesticides in fresh and dried Chinese matrimony vine. In addition, processing factors were calculated based on the residual concentrations in them. METHODS AND RESULTS: The test pesticides, etofenprox and fenitrothion, were sprayed onto the Chinese matrimony vine plants at once or twice (at seven-day interval) and then samples were collected at 0 (after 3 hours), 1, 3, 5 and 7 days after the last spraying. Dried samples were prepared in hot-air drying oven at $60^{\circ}C$ for 48 hours until water content of less than 20%. Residual concentrations of etofenprox in fresh and dried samples decreased by 54.0-60.9% after 7 days of the last pesticide-application. In case of fenitrothion, the concentrations were found to have decreased by 69.2-76.5%. Processing factors of etofenprox were 2.6-3.0 for the one-time spraying and 2.5-3.0 for the two-time spraying and those of fenitrothion were found to be 1.5-22 for the one-time spraying and 1.6-2.0 for the two-time spraying. First half-lives of etofenprox and fenitrothion in fresh and dried samples ranged from 5.0 to 6.3 and from 3.4 to 4.0 days, respectively. The third half-lives were found to be 15.0-18.9 and 10.2-12.1 days, respectively. CONCLUSION: Residual concentrations of the tested pesticides in the studied crop decreased, but those in the dried samples appeared to have increased. In addition, processing factor and half life were constant regardless of spraying times.

Preparation of Nanophase Titania Film by Plasma Spraying

  • Zhu, Yingchun;Huang, Minhui
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.23-26
    • /
    • 1997
  • Nanophase titania film was obtained by plasma spraying. The structure of titania film was investigated with transmission electron microscopy (TEM). It was found taht the film was composed of grains with mean particle size of 15nm. The crystal structure of nanophase titania film was found to be anatase phase by electron diffraction.

  • PDF