• Title/Summary/Keyword: spray system

Search Result 1,254, Processing Time 0.027 seconds

Survey of Planting System and Pesticide Spray Method on Apple Orchards in Korea (국내 사과원의 재배형태 및 농약 살포방법 조사)

  • Kwon, Hyeyoung;Hong, Su-Myeong;Kim, Sang-Su;Paik, Min Kyoung;Lee, Hyo Sub;Kim, Dan-Bi;Moon, Byeong-Chul
    • The Korean Journal of Pesticide Science
    • /
    • v.21 no.1
    • /
    • pp.9-16
    • /
    • 2017
  • A survey was conducted to research on planting system and pesticide spray methods including spray volume, sprayer types, and spray nozzles used in apple orchards. The survey was deployed to 395 farmers in 17 cities and towns including 7 regions which are major producers of apple via interview. Major apple varieties were Fuji (79.2%) and Hongro (50.9%) and high density planting system was mainly used in apple orchards (distance between rows: 4.0-4.5 m (73.1%); planting distance: 1.5-3.5 m (88.6%); canopy height: 3.0-4.5 m (88.2%)). The percentages of sprayer types were 77.6% and 22.1% for speed sprayer (airblast sprayer) and power sprayer, respectively. Spray volumes per 10a were 250-300 L in April, the month of spraying the lowest volume, and 300-400 L in June-August, the months of spraying the highest volume. Significant difference in spray volumes were not observed between conventional planting and high density planting, but regional spray volume showed significant difference. The main nozzles used by apple farmers using power sprayers were super jet nozzle (45%), super wide nozzle (26%), and 2-3 vertical head nozzle (25%). The results will helpful to establish practical agrochemicals management policy including suggestion of pesticide spray volume and evaluation of pesticide residue data and efficacy data.

Characteristics of Spray Deposit Pattern and Flow Rate in the Air-Center Nozzle System (Air-center nozzle의 분무살포도(噴霧撒布度)와 분무량(噴霧量)의 특성(特性))

  • Lee, Sang Woo;Hur, Yun Kun
    • Korean Journal of Agricultural Science
    • /
    • v.7 no.2
    • /
    • pp.156-168
    • /
    • 1980
  • The air-center nozzles, being specially designed to supply air into the central part of water stream at seven levels of air volume, were tested for spray deposit pattern and flow-rate at each of the twelve pressure levels ranging from $0.35kg/cm^2$ (5 psi) to $6.33kg/cm^2$ (90 psi) in comparison with those of standard nozzles. The air-center nozzles produced comparatively more stable spray deposit patterns than the standard nozzles. The spray deposit patterns of the air-center nozzle were concentrated gradually in the central region with increase of air volume as a component of spray mixture. The degree of concentration of spray deposit on the central region from the air-center nozzle was higher than that of the standard nozzle, which suggested the possibility of obtaining farther travel distance spraying system at a given performance level. The flow rate of the air-center nozzle was not as much as that of the standard nozzle due to the air within certain limits. The rate of decrease of water flow became smaller with an increase in operating pressure although it changed rapidly in the beginning stage, ranging up to two or three percent of the air flow rate due to the compressive properties of air.

  • PDF

Intelligent Sprayer System using Tree Recognition (과수 인식을 이용한 지능형 방제기 시스템 개발)

  • Hong, Hyung Gil;Woo, Seong Yong;Song, Su Hwan;Oh, Jang Seok;Yun, Haeyong;Seo, Kab Ho;Kwon, Soon Wook;Lee, Ki Yong;Lee, Jang Chang;Cho, Hee Keun
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.2
    • /
    • pp.115-123
    • /
    • 2020
  • Farmers using conventional sprayer system are exposed to pesticide poisoning and soil pollution due to pesticide application. In order to reduce this problem, the effective sprayer system is required. In this paper, we propose development of intelligent sprayer system using tree recognition. This intelligent sprayer system consists of an image recognition module, a remote control, a sprayer system, an air blower, and a control module. It is possible to spray pesticides automatically and manually through remote control using cameras and controls. We conducted a total of four experiments in tree recognition experiment, test of attachment and water sensitive papers, measurement of pesticide consumption, and measurement of worker exposure. The test results showed that the consumption of pesticides could be reduced while giving the same effect as conventional controls.

Study on Air Washer using Underground Water in the Subway Stations (지하철 역사 지하수를 이용한 에어와셔에 관한 연구)

  • Kim, Dong-Gyu;Kim, Hoe-Youl;Chung, Yong-Hyun;Kim, Jong-Ryul;Kum, Jong-Soo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.22 no.4
    • /
    • pp.604-610
    • /
    • 2010
  • Busan subway transportation system has been established a key role in the society last 20 years. However many people are suffering from hot and humid environment at subway station and platform due to deteriorated ventilation system as well as insufficient air conditioning system in existing stations and platforms. As a result, these systems require revitalization. There is about 5400tons of low temperature underground water is generated from subway stations every day. By using this method and air washer we are trying to lower the temperature. Air washer is commonly used for removing humidity but in this experiment it will be used as air precooling. This research offers result of experiment using air washer system to lower the temperature in large spaces like subway station. The experiment result has shown when L/G was the same, at condition which water spray temperature at $18^{\circ}C$ resulting inlet and outlet temperature difference larger. Also, in the same water spray temperature conditions, larger L/G condition showed a greater temperature difference. LCC evaluation of both system were shown that air washer system of using underground water will save 53% of the initial cost than refrigeration system, and save 75% of operating cost.

Evaluation of the recent live vaccination effects against Newcastle disease under field conditions (최근 야외농장에서 실시하고 있는 뉴캣슬병 생독백신 접종효능에 대한 평가)

  • Song, Chang-seon;Lee, Youn-jeong;Han, Myung-guk;Seong, Hwan-woo;Kang, Kyung-soo;Lee, Joong-bok;Kim, Jae-hak
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.3
    • /
    • pp.563-573
    • /
    • 2000
  • Periodic outbreaks of Newcastle disease (ND) caused by velogenic viscerotropic ND virus (vvNDV) has become a major concern in Korea nowadays. Throughout last epidemic, the winter season in 2000, most chicken flocks infected early, under 2-4 weeks of age, showed high mortality up to 50-100%. Serum samples collected from 201 breeder, 284 layer and 112 broiler chicken flocks were examined to evaluate the efficacy of various vaccination methods and programs routinely used for mass vaccination in the field poultry farms. Despite repeated live vaccination, most poultry flocks vaccinated by drinking water route using nipple water supply system failed to produce solid active immune response to NDV during the growing time. In the present study, we applied the spray vaccination technique using Ulvavac or Desvac sprayer to the experimental poultry flocks and examined the efficacy of live vaccination effects induced by it under field condition. Measurable antibody to NDV as well as early protection against vvNDV challenge were found in poultry flocks vaccinated by spray route. Further, we did not found significant post vaccination reactions caused by spray vaccination if properly administered. These data indicate that the spray vaccination will be safe and reliable mass vaccination method for the prevention of ND.

  • PDF

Feature of Spray Transport and Atomization from Two-Phase Swirling Jet with Air-to-Liquid Mass Ratio (공기액체질량비에 따른 이류체 선회형 분사의 분무거동 및 미립화 특성)

  • Lee, Sam-Goo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.2
    • /
    • pp.39-45
    • /
    • 2004
  • Experiments were performed in a two-phase swirling spray facility that has been described elsewhere. Measurements of spray transport and drop size distribution are analyzed over wide ranges of air to liquid mass flow ratios, utilizing four different internal mixing pneumatic nozzles. The spatial distributions of mean velocities. fluctuating velocities, and velocity-diameter correlation were quantitatively analyzed. Also, the exponential correlation curves were obtained with ALR along the spray centerline, which indicated an approximately identical formulation regardless of ALR. It indicated that the atomization characteristics were remarkably superior in the case of 30o of swirl angle with higher ALR. Among other things. nozzle configuration is one of the significant parameters affecting spray phenomena from an internal mixing nozzle. Turbulence intensities are increasingly degenerated with an increase of nozzle configuration, allowing a rapid increment of drop size distribution.

Comparison between GOx/Kerosene and GN2O/Ethanol Reactive Spray in a Subscale Liquid Rocket Engine (축소형 액체로켓엔진에서 기체산소/케로신 및 기체아산화질소/에탄올 연소 분무의 비교)

  • Choi, Songyi;Shin, Bongchul;Lee, Keonwoong;Kim, Dohun;Koo, Jaye;Park, Dong-Kun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.4
    • /
    • pp.61-68
    • /
    • 2015
  • Reactive sprays of two propellant combinations(GOx/kerosene and $GN_2O$/ethanol) were observed and compared with each other as a basic research of visualizing supercritical combustion. A shadowgraph imaging method was used to visualize the reactive sprays, and shadowgraph images were converted to density gradient magnitude images to analyse the structure of reactive sprays. The gas-liquid interface of GOx/kerosene spray showed rougher boundary and steeper density gradient near the injector face than the $N_2O$/ethanol at similar combustion chamber pressure. Spray core length was calculated from averaged density gradient magnitude images and it was revealed that spray core length of GOx/kerosene was shorter than that of $GN_2O$/ethanol, although momentum flux ratio of GOx/kerosene propellant combination was lower.

Numerical study on the foam spraying for AFDSS applicable to initial fire suppression in large underground spaces (지하대공간 초동 화재진압에 적용가능한 자율형 소화체계의 폼 분사 해석 기법 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Whiseong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.503-516
    • /
    • 2021
  • Autonomous fire detection and suppression system requires advanced technology for complex detection technology and injection/control technology for accurate hitting by fire location. Also, foam spraying should be included to respond to oil fires. However, when a single spray monitor is used in common, water and foam spray properties appear different, so for accurate fire suppression, research on the spray trajectory and distance will be required. In this study, experimental studies and numerical analysis studies were combined to analyze the foam spray characteristics through the spray monitor developed for the establishment of an autonomous fire extinguishing system. For flow analysis of foam injection, modeling was performed using OpenFOAM analysis software, and the commonly used foaming agent (Aqueous Film-Forming Foam) was applied for foam properties. The injection distance analysis was performed according to the injection pressure and the injection angle according to the form of the foam, and at the same time, the results were verified and presented through the injection experiment.

Surface Characteristic of Graphene Coated Stainless Steel for PEMFC Bipolar Plate (그래핀이 코팅된 스테인리스강의 고분자전해질 연료전지 분리판 적용을 위한 표면 특성)

  • Lee, Su-Hyung;Kim, Jung-Soo;Kang, Nam-Hyun;Jo, Hyung-Ho;Nam, Dae-Guen
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.5
    • /
    • pp.226-231
    • /
    • 2011
  • Graphene was coated on STS 316L by electro spray coating method to improve its properties of corrosion resistance and contact resistance. Exfoliated graphite (graphene) was made of the graphite by chemical treatment. Graphene is distributed using dispersing agent, and STS 316L was coated with diffuse graphene solution by electro spray coating method. The structure of the exfoliated graphite was analyzed using XRD and the coating layer of surface was analyzed by using SEM. Analysis showed that multi-layered graphite structure was destroyed and it was transformed into fine layers graphene structure. And the result of SEM analysis on the surface and the cross section, graphene layer was uniformly formed with 3~5 ${\mu}m$ thickness on the surface of substrate. Corrosion resistance test was applied in the corrosive solution which is similar to the PEM fuel cell stack inside. And interfacial contact resistance test was measured to simulate the internal operating conditions of PEM fuel cell stack. The results of measurements show that stainless steel coated with graphene was improved in corrosion resistance and surface contact resistance than stainless steel without graphene coating layer.