• Title/Summary/Keyword: spray frequency

Search Result 121, Processing Time 0.019 seconds

Evaluation of the Adhesion Strength of Metal Spray Coating System in Steel using High-frequency Arc Metal Spray Method (고주파 아크 금속용사기를 이용한 금속용사 코팅계의 부착강도 평가)

  • Choe, Hong-Bok;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.96-97
    • /
    • 2014
  • The purpose of this study is to analyze the adhesion strength of metal spray coating system in steel using high-frequency arc metal spray method. For the purpose the experimental factor such as surface roughness was selected at 3 levels. As a result of experiment, it appeared that high-frequency arc metal spray method had higher adhesion strength than existing metal spray method. Especially, Al-Mg showed the highest adhesion strength than other metals. In case of surface roughness, the higher roughness steel has, the higher adhesion strength appeared.

  • PDF

An Experimental Study on the Evaluation of Anti-corrosion Performance of High-frequency Arc Metal Spray film on Steel using EIS Method (전기화학적 임피던스 분광법(EIS)을 이용한 고주파 아크 금속용사 피막의 강재 방식성능 평가에 관한 실험적 연구)

  • Choe, Hong-Bok;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.61-62
    • /
    • 2014
  • To evaluate anti-corrosion performance of high-frequency arc metal spray film in accordance with metal type and epoxy sealing coat application status, electrochemical impedance spectroscopy(EIS) method was conducted in this study. As a result, in case of applying Al-Mg alloy metal spray film, it showed the best polarization resistance. In case of applying epoxy sealing coat, it showed increased polarization resistance of arc metal spray film. Through this experiment, it is judged that Al-Mg alloy arc metal spray film with epoxy sealing coat can increase the biggest anti-corrosion performance of high-frequency arc metal spray film on steel.

  • PDF

Reducing Fungicidal Spray Frequency for Major Apple Diseases by Increasing the Spray Interval from 15 to 25 days

  • Lee, Dong-Hyuck;Shin, Ho-Cheol;Cho, Rae-Hong;Uhm, Jae-Youl
    • The Plant Pathology Journal
    • /
    • v.25 no.3
    • /
    • pp.270-279
    • /
    • 2009
  • During the course of a study to develop a spraying program at 15-day spray intervals, two important findings were identified allowing for further reduction of spray frequency by increasing the spray interval. In evaluating the contribution of fungicides from a 15-day spray interval program, control of white rot, which is of prime importance in Korea, was not affected, in spite of the extended spray interval caused by omitting the fungicides during the season. In another experiment assessing the duration of the protective activities of several key fungicides used in the 15-day spray interval program, infection control was maintained for almost 30 days for some fungicide. Based on these two findings, a basic spraying program with a 25-day spray interval was developed. This program was modified for four successive years to improve the control efficacy against bitter rot and Marssonina blotch, which sometimes causes as much damage as white rot.

Spray Characteristics of a Pulsed Liquid Jet into a Cross-flow of Air (아음속 횡단 유동장으로 펄스 분사된 액체 제트의 분무특성)

  • Lee, In-Chul;Byun, Young-Wu;Koo, Ja-Ye
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.61-64
    • /
    • 2008
  • The present study of these experiments are close examination of spray characteristics that are continuous liquid jet and modulated pressure pulse liquid jet. The experiments were conducted using water, over a range of cross-flow velocities from 42${\sim}$136 m/s, with injection frequencies of 35.7${\sim}$166.2 Hz. Between continuous cross-flow jet and pressure pulsed cross-flow jet for characteristics of penetration, breakup point, spray angle and macro spray shape are investigated experimentally. In cross-flow field, main parameter of liquid jet for breakup was cross-flow stream rather than pressure pulse frequency. As oscillation of the periodic pressure that could make liquid jet moved up and down, the mixing efficiency was increased. Also, a bulk of liquid jet puff was detected at upper field of liquid surface. So, this phenomenon has a good advantage of mixing spray from concentration of center area to outer area. Because of pressure pulsation frequency, an inclination of SMD for the structured layer was evanescent. Cross-sectional characteristics of SMD at downstream area were non-structured distributions. Then cross-sectional characteristics of SMD size were about same tendency over a range that is effect of spray mixing. The tendency of volume flux value for various frequency of pressure pulse was same distribution. And volume flux was decreased when the frequency of pressure pulse increase.

  • PDF

SELF-PULSATION CHARACTERISTICS OF A SWIRL COAXIAL INJECTOR WITH VARIOUS INJECTION AND GEOMETRIC CONDITIONS

  • Im, Ji-Hyuk;Kim, Dong-Jun;Yoon, Young-Bin;Bazarov, V.
    • Journal of ILASS-Korea
    • /
    • v.10 no.3
    • /
    • pp.29-37
    • /
    • 2005
  • The spray and acoustic characteristics of a gas/liquid swirl coaxial injector are studied experimentally. The self-pulsation is defined as a pressure and flow rate oscillations by a time-delayed feedback between liquid and gas phase. Self-pulsation has strong influences on atomization and mixing processes and accompanies painful screams. So. the spray and acoustic characteristics are investigated. Spray patterns are observed by shadow photography technique in order to determine the onset of self-pulsation. And self-pulsation boundary with Injection conditions and recess length is get. To measure the frequency of the spray oscillation. oscillation of the laser intensity which passes through spray is analyzed by Fast Fourier Transform. For acoustic tests, a PULSE System was used. Acoustic characteristics of a swirl coaxial injector are investigated according to the injection conditions. such as the pressure drop or the liquid and gas phase. and injector geometries. such as recess length and gap size between the inner and outer injector. Front the experimental results. the increase of recess length leads to the rapid increase of the sound pressure level. And as the pressure drop of the liquid phase increases. the frequency of the self?pulsation shifts to the higher frequency. The frequency of spray oscillations is the same as that of the acoustic fields by self-pulsation.

  • PDF

The change of spray characteristics on hydraulic acoustic wave influence and prediction of low combustion instability (수력파동에 의한 분무변화 및 저주파 연소불안정에의 영향 예측)

  • Kim, Tae-Kyun;Lee, Sang-Seung;Yoon, Woong-Sup
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.152-160
    • /
    • 2004
  • Studies to investigate the influence on hydraulic acoustic wave were conducted using pressure swirl atomizer under making frequency range from 0 to 60Hz using water as a propellant. Pressure oscillation from hydraulic sources gives a strong influences on atomization and mixing processes. The ability to drive these low frequency pressure oscillations makes spray characteristics changeable. The effect of pressure perturbation and its spray characteristics showed that low injector pressure with pressure pulsation gives more significantly than high injector pressure with pressure perturbation in SMD, spray cone angle, breakup length. Moreover, this data could be used for prediction of low combustion instability getting G factor.

  • PDF

Spray Characteristics of Modulated Liquid Jet Injected into a Subsonic Crossflow (주파수 변조 분사가 횡단 유동장의 분무 특성에 미치는 영향)

  • Lee, I.C.;Kim, J.H.;Koo, J.Y.
    • Journal of ILASS-Korea
    • /
    • v.14 no.2
    • /
    • pp.59-64
    • /
    • 2009
  • These experiments are close examination of spray characteristics that are continuous liquid jet and modulated liquid jet. The experiments were conducted using water, over a range of crossflow velocities from $42{\sim}l36\;m/s$, with modulation frequencies of $35.7{\sim}166.2\;Hz$. Between continuous crossflow jet and modulated cross-flow jet of penetration, breakup point, spray angle and macro spray shape are experimentally investigated with image analysis. In cross-flow field, main parameter of liquid jet for breakup was cross-flow stream rather than modulation effect. As oscillation of the periodic pressure that could make liquid jet moved up and down, the mixing efficiency was increased. Also, a bulk of liquid jet puff was detected at upper field of liquid surface. So, this phenomenon has a good advantage of mixing spray from concentration of center area to outer area. Because of modulation frequency, SMD inclination of the structured layer was evanescent. Cross-sectional characteristics of SMD at downstream area were non-structured distributions. Then cross-sectional characteristics of SMD size were about same tendency over a range that is effect of spray mixing. The tendency of volume flux value for various modulation frequency was same distribution. And volume flux was decreased when the modulation frequency increase.

  • PDF

Temperature measurement of the spray flame using micro scale absorption bands and line strength (마이크로 스케일의 흡수선과 흡수강도를 이용한 분무화염의 온도측정)

  • Choi, G.M.
    • Journal of ILASS-Korea
    • /
    • v.7 no.2
    • /
    • pp.1-6
    • /
    • 2002
  • It is necessary to develope a high frequency diode laser sensor system based on the absorption spectroscopy for the measurement of temperature of the spray flame. DFB diode laser operating near $2.0{\mu}m$ was used to scan over selected $H_2O$ transitions near $1.9{\mu}m\;and\;2.2{\mu}m$, respectively. The measurement sensitivity at wide range of sweep frequency was evaluated using multi-pass cell containing $CO_2$ gas. This diode laser absorption sensor with high temporal resolution up to 10kHz was applied to measure the gas temperature in the spray flame region of liquid-gas 2-phase counter flow flame. The successful demonstration of time series temperature measurement in the spray flame gives us motivation of trying to establish non-intrusive temperature measurement method in the practical spray flame.

  • PDF

Spray Characteristics of Simplex Swirl Injector with Low Hydrodynamic Disturbance Generated by Pressure Fluctuation in Feed Line (축방향 압력섭동에 의해 발생되는 저주파 수력학적 교란이 단일 스월 인젝터에 미치는 영향 분석)

  • Khil, Tae-Ock;Kim, Sung-Hyuk;Kim, Hyeon-Sung;Yoon, Young-Bin
    • Journal of ILASS-Korea
    • /
    • v.12 no.1
    • /
    • pp.1-10
    • /
    • 2007
  • The low frequency combustion instability phenomena generated by pressure drop oscillation such as propellant shake in feed line are studied. To generate the flowrate oscillation by the pressure pulsation up to 400Hz without flow discontinuities and cavitations, a hydrodynamic mechanical pulsator of rotating disk type was produced. Injection pressure conditions are 5, 7 and 9 bar and pressure fluctuation frequency conditions are 0, 4, 6 and 8 Hz. When the injection pressure was oscillated by a mechanical pulsator, the spray shape was pulsated regularly. During the pulsated state of the spray with a mechanical pulsator, the spray characteristics, such as spray angle and liquid film thickness in orifice exit, were measured and compared with those in steady state without a mechanical pulsator. Though the mean injection pressure was fixed in the steady and fluctuating state, there were some differences in all measured values, i.e. liquid film thickness and spray cone angle, between both states.

  • PDF

Evaluation of the Corrosion Protective Property in Steel applying Spray Metal by using High-frequency Arc Metal Spray Method (고주파 아크 금속용사공법을 이용한 용사금속의 방식성능 평가)

  • Choe, Hong-Bok;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.94-95
    • /
    • 2014
  • The purpose of this study is to evaluate the corrosion protective property of Al-Mg high-freqeuncy arc metal spray method in comparison to Zn-Sn and Zn-Al alloys by electrochemical method and CASS test. As a result, it appeared that Al-Mg alloy had very higher corrosion protective property through the electrochemical characteristic and the CASS test comparing with the other alloys.

  • PDF