• 제목/요약/키워드: spot welded tensile shear specimens

검색결과 24건 처리시간 0.025초

점용접 아연도금판의 강도특성에 대한 온도 및 침수의 영향 (Effect of Temperature and Water Assumtion on Strength of Spot Welded Zine Steel Plates)

  • 서도원;윤호철;최준용;임재규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.358-363
    • /
    • 2003
  • Spot welded structure is operated in diverse situation because of temperature, humidity and precipitation. In addition factors of environmental pollution such as acid rain, that courses corrosion, have the tendency to increase, But spot welded structure strength is affected by dampness and environment temperatures. Therefore, it is important to evaluate effect of temperature of spot welded part, In this study, the strength distribution of spot welded plates is evaluated about the environmental temperature of zine coated steel plates and test is conducted with welded part immersed in distilled and synthetic sea water. Specimens are immersed into water for 10, 100, 500 and 1000hours to evaluate the effects of water immersion time on tensile-shear strength under the conditions of -40, 0, 20 and $50^{\circ}C$. Strength is evaluated by tensile-shear test. The conditions of spot welding are 240kgf electrode force, 10KA welding current with 0 and 5mm clearance. From this study, spot welded specimens with clearance have lower tensile-shear strength in the distilled water or synthetic sea water comparing with spot welded specimens without clearance. And they have lower tensile-shear strength under $-40^{\circ}C$ and over $50^{\circ}C$.

  • PDF

初期 過荷重이 點熔接 引張剪斷 試驗片의 疲勞擧動에 미치는 影響 (The Influence of Initial Overloads on the Fatigue Life of Spot-welded Tensile-shear Specimens)

  • 강성수;정원욱
    • Journal of Welding and Joining
    • /
    • 제13권2호
    • /
    • pp.60-67
    • /
    • 1995
  • The factors affecting on the fatigue strength of spot_welded specimens have been studied. The influence of initial overloads on the fatigue life of spot_welded tensile_shear specimens is investigated by considering fatigue crack initiation and crack propagation. The change of strain range and the influence of initial overload are correlated on the basis ol strain results. The results of this study are as follows. l) The initial absolute strain range decreased with initial overloads increase, and absolute strain range decreased before transformation of waveform of strain, but increased after transformation of waveform of strain. 2) In case of subsequent point of inflection of offset strain, the increment of this strain decreased with initial overload increase. 3) As initial overloads increase, the deformation behavior of spot welded parts is restricted after overloading.

  • PDF

점용접 아연도금강판의 강도특성에 미치는 온도 및 침수의 영향 (Effect of Temperature and Water Immersion on Strength Properties of Spot Welded Zincked Steel Plates)

  • 서도원;최준용;임재규
    • 대한기계학회논문집A
    • /
    • 제28권12호
    • /
    • pp.1864-1870
    • /
    • 2004
  • A spot welded structures have an influence on a diverse climatic situation, for instance temperature, humidity and precipitation. In addition factors of environmental pollution such as acid rain, that courses corrosion, have the tendency to increase. But spot welded structures strength is affected by humidity and environment temperature. Therefore, it is important to evaluate effect of temperature and water immersion on strength properties of spot welded part. In this study, the strength distribution of spot welded plates is evaluated the environmental temperature of zinc coated steel plates. Test is conducted with welded part immersed in distilled and synthetic sea water. Specimens are immersed into water for 10, 100, 500 and 1000 hours to evaluate the offsets of water immersion time on tensile-shear strength under the conditions of -40, 0, 20 and 5$0^{\circ}C$. From this result, spot welded specimens with 5 mm clearance have lower tensile-shear strength in the distilled water or synthetic sea water than without clearance. And they have lower tensile-shear strength under -4$0^{\circ}C$ and over 5$0^{\circ}C$.

음향방출을 이용한 저항 점용접의 용접 품질평가 (Quality Evaluation of Resistance Spot Welding using Acoustic Emission)

  • 조대희;이장규;박성완;조진호;김봉각;우창기
    • 한국공작기계학회논문집
    • /
    • 제15권4호
    • /
    • pp.98-104
    • /
    • 2006
  • In this paper, for the purpose of investigation the acoustic emission(AE) behaviors during resistance spot welding process and tension test of spec steels. As the results present the resistance spot welding method that can get suitable welding qualities or structural integrity estimating method. The resistance spot welding process consists of several stages: set-down of the electrodes; squeeze; current flow; forging; hold time; and lift-off. Various types of AE signals are produced during each of these stages. For tensile-shear test and cross tensile test in resistance spot welded specimens, fracture pa 야 ems are produced: tear fracture; shear fracture; and plug fracture. Tensile-shear specimens strength appeared higher than cross tensile specimens one. In case of tensile-shear specimen happened tear fracture that crack happens in most lower plate. Also, in case of cross tensile specimens, upper plate and lower plate are detached perfect fracture was exposed increases a little as acting force is lower than ordinary welding condition. Therefore, the structure which is combined by resistance spot welding confirmed that welding design must attain so that shear stress may can interact mainly.

Fatigue Analysis of Spot Welded Joints in Suspension Mounting Part

  • Yum, Youung-Jin;Chu, Young-Woo;Chu, Seok-Jae;Kim, Jung-Han;Hee You
    • Journal of Mechanical Science and Technology
    • /
    • 제17권8호
    • /
    • pp.1113-1119
    • /
    • 2003
  • Experimental and numerical analyses were performed to characterize the fatigue behavior of spot welded joints in suspension mounting of a passenger car body. Static and fatigue tests were carried out for the tensile-shear and cross-tension specimens. S-N curve and fatigue strengths were obtained from the fatigue test of various specimens. Nonlinear finite element analysis showed that fatigue behavior of spot welded joints could be well estimated in terms of Von Mises stress at the nugget edge. Fatigue behavior of spot welded joint was represented by Von Mises stress better than the fatigue load.

인장-전단 하중을 받는 점용접부의 피로 수명 평가에 관한 연구 (A Study on the Fatigue Life Evaluation of Spot Welded Joints under Tensile-Shear Loading)

  • 정강;김훈
    • 동력기계공학회지
    • /
    • 제5권1호
    • /
    • pp.80-88
    • /
    • 2001
  • The spot welding method has been used in the joining of structures, automotive body, railway carriage, aircraft, household electric appliances, precision parts etc., because of brief working, easy automation, available mass production, and convenience. In this paper, the effects of welding conditions on the fatigue life and the prediction of fatigue life based on fracture mechanics theory of spot welded joint were investigated. Fatigue tests were conducted with the tensile-shear specimens welded in the various current using cold rolled steel sheets. Fatigue life of spot welded joint was predicted and compared with experimental results. Using FEM(finite element method), we analysed the distribution of stress and the condition of deformation on the environments of nugget.

  • PDF

인장-전단 하중을 받는 점용접부의 피로균열 전파거동에 관한 연구 (A Study on the Fatigue Crack Propagation Behavior of Spot Welds under Tensile-shear Load)

  • 이용복
    • 한국생산제조학회지
    • /
    • 제6권4호
    • /
    • pp.27-33
    • /
    • 1997
  • Spot welding has been used in the sheet metal jointing processes because of its high productivity and convenience. In this study, effects of welding conditions on the fatigue life and prediction methods of fatigue life of spot welded joint have been studded . Fatigue life was estimated by stress index parameter considering multiaxial stresses. Fatigue tests were conducted with the tensile-shear specimens using SPCC. Fatigue life of spot welded joint was influenced by welding currents and was predicted exactly with taking into account StageIII.

  • PDF

고장력 강판의 점용접부에서 면내 굽힘 모멘트가 피로특성 및 균열 성장 거동에 미치는 영향에 관한 연구(I) - 실험적 검토 - (A Study on the Effect of Fatigue and Crack Propagation Behavior in Spot Weld of High Strength Steel( I ) - Experimental Examination -)

  • 성기찬;장경복;정진우;김기순;강성수
    • Journal of Welding and Joining
    • /
    • 제19권1호
    • /
    • pp.112-117
    • /
    • 2001
  • The factor affecting on the fatigue strength of spot welded specimen have been studied. To analyze and predict crack initiation position and propagation directions on the spot welded area are very important for strength design of the automobile body structure. In fact, there are a various of loads in running automobile but, it is impossible to replay like an actual conditions in the laboratory. So, in this study tensile-shear type and in-plane bending type specimens were used in fatigue test and includes an analysis of fatigue crack initiation position and propagation directions about earth specimens. The results obtained in the present study are summarized as follows: 1. In tensile-shear type fatigue test, the region of fatigue crack initiation position was affected by out-of-plane bending deformation due to bending angle. 2 In in-plane bending type fatigue test, the behavior of fatigue crack initiation position and propagation derections due to angle between upper plate and lower plate was dominated by magnitude of in-plane bending moment.

  • PDF

저항점용접과 $CO_2$ 플러그용접의 피로거동 연구 (The comparision of fatigue behavior of $CO_2$ plug weld and resistance spot weld)

  • 정원욱;정연수;강성수
    • 대한기계학회논문집A
    • /
    • 제22권3호
    • /
    • pp.554-561
    • /
    • 1998
  • Vehicle body structures are formed by thousands of spot welds and fatigue failure of vehicle structures occur near the spot welds after driving a long way at a durability test road. It is necessary to know accurately the reason of the fatigue failure of the spot weld in the developing stage in order to reinforce it. Many investigations have been done regarding the strength of spot welded joints, contributing to understand its fatigue strength. In developing process, a fatigue failed spot welded area can be repaired by $CO_2$ welding or another method to continue the test. To know the effect of reinforcing these welds, several methods of welding were analyzed and compared to spot welding. With the results of this test, the appropriate repair method can be used instead of spot welding during the development of new car and best design guide can be given for the strength. In this study, fatigue and static tensile tests are made and microstructure is investigated for the purpose of estimating the strength of welded joints by using spot welded and $CO_2$ plug welded specimens. The tested specimens are of two types : Tensile-shear type(TS) and L-tension type(LT).

음향방출법에 의한 저항 점용접부의 파괴특성에 대한 연구 (Fracture Characteristics of the Resistance Spot Welded Joints by Acoustic Emission)

  • 조대희;이장규;박성완;김봉각;우창기
    • 한국공작기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.14-22
    • /
    • 2007
  • In this paper, the acoustic emission(AE) behaviors were investigated with single-and 2-spot resistance spot welded SPCC specimens. Test specimens were welded horizontally and/or vertically according to the rolling direction of base netal in 2-spot welding. In the case of 2-spot welding, when tensile-shear test has below amplitudes: crack initiation $50{\sim}60dB;$ tear fracture $40{\sim}50dB$. And when cross tensile test has below amplitudes: early stage $75{\sim}85dB;$ yielding point $65{\sim}75dB;$ post yielding $40{\sim}60dB;$ plug fracture $70{\sim}80dB\;or\;90{\sim}100dB$. Also, from the b-value that is slope of AE amplitude, we knew that there are lots of low amplitudes if b-value is big(i.e., tensile-shear $specimen{\rightarrow}tear$ fracture or shear fracture), and there are lots of high amplitudes if b-value is small(i.e.. cross tensile $specimen{\rightarrow}plug$ fracture). As the results of fiacture mechanism analyses through AE amplitude distributions, change of the b-value represented fracture patterns of materials. Correspondingly, low amplitude signals appeared in crack initiation, and high amplitude signals appeared in base metal fracture. We confirmed that these amplitude distributions represented the change or degradation of materials.