• Title/Summary/Keyword: spot scanning

Search Result 122, Processing Time 0.029 seconds

The Effects of Signal Delay on Scanning Velocity Modulation in CRT

  • Choo, Seong-Hun;Choi, Jong-Hoon;Bae, Min-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.1160-1163
    • /
    • 2003
  • The effects of time delay between a video signal and a current signal applied to velocity modulation coil on free-spot movement and beam size were measured and analyzed quantitatively in this study. The result shows that it is the most important to avoid signal mismatching in order to achieve the optimal velocity modulation performance.

  • PDF

Characterization of North American Ginseng Rust-Spot and the Effects of Ethephon

  • Campeau, Cindy;Proctor, John T.A.;Murr, Dennis P.;Schooley, Jan
    • Journal of Ginseng Research
    • /
    • v.27 no.4
    • /
    • pp.188-194
    • /
    • 2003
  • Rust-spot on North American ginseng roots (Panax quinquefolius L.) is considered a physiological, not a pathological disorder. Ginseng rust-spot starts as an orange spot on the surface of the root and may spread forming a sunken, round to irregular lesion. 5 mm in diameter. Pieces of root, 7 mm in length and containing a rust-spotted lesion, were embedded in agar and sectioned using a vibratome. These sections and hand sections, cut with a two-sided razor blade, were examined using fluorescence microscopy. The 4-5 cell layers of the periderm were destroyed in the area of the lesion and orange substance:, were deposited in and around the lesion. Sections stained with vanillin-HCI and viewed using bright field microscopy confirmed that the orange substances were phenolic compounds. Scanning electron micros-copy showed that the periderm had pulled away from the root, or was completely destroyed, in the area of the lesion. The smooth surface of the lesion indicates the deposition of phenolic compounds in surrounding cells as a wound response. Roots sprayed or dipped in ethephon (1500 mgㆍL$^{-1}$ ) developed rust-spots, more so at 21$\pm$2$^{\circ}C$ than at 3$\pm$0.2$^{\circ}C$. Roots held at 21$\pm$2$^{\circ}C$ were yellowish and developed white cell proliferations. Comparable control roots also developed rust-spots likely due to the high undecomposed organic matter content of the incubation soilless mix.

Resistance Spot Welding of Dissimilar Materials of Austenitic Stainless Steels and IF (Interstitial Free) Steels (저항 점 용접을 이용한 AISI 316 스테인레스강과 용융아연도금 강판의 이종접합)

  • Lee, Jin-Bum;Nam, Dae-Geun;Kang, Nam-Hyun;Kim, Yang-Do;Oh, Weon-Tae;Park, Yeong-Do
    • Korean Journal of Materials Research
    • /
    • v.19 no.7
    • /
    • pp.369-375
    • /
    • 2009
  • The spot weldability of dissimilar metal joints between stainless steels (AISI316) and interstitial free (IF) steels were investigated. This study was aimed to determine the spot welding parameters for a dissimilar metal joint and to evaluate the dissimilar metal joint's weldability, including its welding nugget shape, tensileshear strength, hardness, and microstructure. The fracture surface was investigated by using a Scanning Electron Microscopy (SEM). The experimental results showed that the shape of nugget was asymmetric, in which the fusion zone of the STS316 sheet was larger due to the higher bulk-resistance. The microstructure of the fusion zone was fully martensite. In order to evaluate the microstructure further, dilution of stainless steels were calculated and imposed onto the Schaeffler diagram. The predicted microstructure from the Schaeffler diagram was martensite. In order to confirm the predicted microstructure, XRD measurements were carried out. The results showed that that initial weld nugget was composed of austenite and martensite.

A Study on Design and Analysis for Magnetic Lenses of a Scanning Electron Microscope using Finite Element Method (유한요소법을 사용한 주사전자 현미경의 전자렌즈 설계 및 해석에 관한 연구)

  • Park, Keun;Jung, Hyun-Woo;Park, Man-Jin;Kim, Dong-Hwan;Jang, Dong-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.9
    • /
    • pp.95-102
    • /
    • 2007
  • The scanning electron microscope (SEM) is one of the most popular instruments available for the measurement and analysis of the micro/nano structures. It is equipped with an electron optical system that consists of an electron beam source, magnetic lenses, apertures, deflection coils, and a detector. The magnetic lenses playa role in refracting electron beams to obtain a focused spot using the magnetic field driven by an electric current from a coil. A SEM column usually contains two condenser lenses and an objective lens. The condenser lenses generate a magnetic field that forces the electron beams to form crossovers at desired locations. The objective lens then focuses the electron beams on the specimen. The present work concerns finite element analysis for the electron magnetic lenses so as to analyze their magnetic characteristics. To improve the performance of the magnetic lenses, the effect of the excitation current and pole-piece design on the amount of resulting magnetic fields and their peak locations are analyzed through the finite element analysis.

Performance Analysis of Scanning Scheme Using ToF for the Localization of Optics-Based Sensor Node (광신호 기반 무선 센서 노드 위치 인식을 위한 ToF 기법의 성능 분석)

  • Jang, Woo Hyeop;Park, Chan Gook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.3
    • /
    • pp.268-274
    • /
    • 2013
  • In this paper, the performance analysis of optics-based sensor node localization using ToF (Time of Flight) scheme is conducted. Generally, the position of the sensor node is calculated on the base station. And the base station scans neighboring sensor nodes with a laser. The laser which is reflected from one sensor node, however, can be reached to the base station at different angles according to the scanning resolution. This means that the error of the reached angle can increase and one node may be recognized as different nodes. Also the power of laser can decrease because the laser signal spread. Thus the sensor node which is located at a long distance from the base station cannot be detected. In order to overcome these problems which can be occurred in localization using ToF, the beam spot, the scanning resolution, the size of reflector and the power of laser at the sensor node were analyzed. It can be expected that the consequence of analysis can be provided in acquisition of accurate position of sensor node and construction of optics-based sensor node localization system.

Near field scanning optical interferometer using facet reflection of a tapered optical fiber (광섬유 탐침의 반사를 이용한 파면 분석 근접장 주사 광간섭계)

  • 유장훈;임상엽;이현호;박승한
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.248-253
    • /
    • 2004
  • We propose a near- field scanning optical interferometer (NSOI) based on the facet reflection of a nano-sized moveable tapered optical fiber. The interferometer can measure the position and the wave-front of a focused spot simultaneously. The interfering fringes are generated by the reflected beams from the sample surface and from the fiber facet. The wave-front analysis at the focusing position is obtained by using a phase shifting technique with a four-step algorithm. It is found that the resolution for controlling the focal position of our proposed NSOI is less than λ/3 and the measured wave-front aberration at the focal position is in good agreement with the ones obtained by a Twyman-Green interferometer.

Direct Measurement of Diffusion Length in Mixed Lead-halide Perovskite Films Using Scanning Photocurrent Microscopy

  • Kim, Ahram;Son, Byung Hee;Kim, Hwan Sik;Ahn, Yeong Hwan
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.514-518
    • /
    • 2018
  • Carrier diffusion length in the light-sensitive material is one of the key elements in improving the light-current conversion efficiency of solar-cell devices. In this paper, we measured the carrier diffusion length in lead-halide perovskite ($MAPbI_3$) and mixed lead-halide ($MAPbI_{3-x}Cl_x$) perovskite devices using scanning photocurrent microscopy (SPCM). The SPCM signal decreased as we moved the focused laser spot away from the metal contact. By fitting the data with a simple exponential curve, we extracted the carrier diffusion length of each perovskite film. Importantly, the diffusion length of the mixed-halide perovskite was higher than that of the halide perovskite film by a factor of 3 to 6; this is consistent with the general expectation that the carrier mobility will be higher in the case of the mixed lead-halide perovskites. Finally, the diffusion length was investigated as a function of applied bias for both samples, and analyzed successfully in terms of the drift-diffusion model.

A Study on Automatic Space Analysis for Plant Facilities Based on 3D Octree Argorithm by Using Laser Scanning Information

  • Kim, Donghyun;Kwon, Soonwook;Chung, Suwan;Ko, Hyunglyul
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.667-668
    • /
    • 2015
  • While the plant projects grow bigger and global attention to the plant is increasing, efficient space arrangement is not working in plant project because of the complex structure in installing the equipment unlike the construction project. In addition to this, presently, problem in installation process caused by the disagreement between floor plan and real spot is rising. Therefore the target of this research is to solve the problems and reaction differences, caused by changing the space arrangement in installing the equipment of plant construction. And this research suggests the equipment arrangement method for construction and related processes. To solve the problem, 3D cloud point data of space and equipment is collected by 3D laser scanning and the space matching is operated. In processing the space matching, data is simplified by applying the octree algorithm. This research simplifies the 3D configuration data acquired by 3D scanner equipment through the octree algorithm, and by comparing this data, identifies the space for target equipment, and finally suggests the algorithm that makes the auto space arrangement of equipment possible in construction site and also suggests the process to actualize this algorithm.

  • PDF

Comparative Ultranstructures of the Fertilized Egg Envelopes from Three-spot gourami, Pearl gourami and Marble gourami, Belontiidae, Teleost (경골어류 등목어과 Three-spot gourami, Pearl gourami 및 Marble gourami의 수정란 난막 미세구조 비교)

  • Kim, Dong-Heui;Deung, Young-Kun;Kim, Wan-Jong;Reu, Dong-Suck;Kang, Song Jian
    • Applied Microscopy
    • /
    • v.29 no.3
    • /
    • pp.343-351
    • /
    • 1999
  • The structures of the fertilized egg envelope from three species, three-spot gourami (Trichogaster trichopterus), pearl gourami (Trichogaster leeri) and marble gourami (Trichogaster trichopterus trichopterus) belong to Belontiidae were observed, utilizing light, scanning and transmission electron microscopes. In all three species, the fertilized eggs were the colorless, transparent, spherical, adhesive and pelagic type. A large oil droplet was located in vitelline membrane of the fertilized egg. The egg envelopes have a single micropyle, which is thought to the pathway of sperm in the area of the animal pole. Specially, the micropyle of three-spot gourami was similar to that of marble gourami which is subspecies of three-spot gourami. An outer surface of the fertilized egg envelope was arranged by grooves in all three species. The fertilized egg envelopes consists of two distinct layers; an adhesive outer layer and an inner layer with high electron density. In conclusion, the morphological similarity of the fertilized egg, micropyle, outer surface and transverse section of the fertilized e9g envelope seems to be an indication of the Belontiidae.

  • PDF