• 제목/요약/키워드: splitting tensile

검색결과 274건 처리시간 0.024초

Fresh and hardened properties of concrete incorporating ground granulated blast furnace slag-A review

  • Patra, Rakesh Kumar;Mukharjee, Bibhuti Bhusan
    • Advances in concrete construction
    • /
    • 제4권4호
    • /
    • pp.283-303
    • /
    • 2016
  • Several types of industrial byproducts are generated. With increased environmental awareness and its potential hazardous effects, the utilization of industrial byproducts in concrete has become an attractive alternative to their disposal. One such by-product is ground granulated blast furnace slag (GGBS), which is a byproduct of the smelting process carried out in the iron and steel industry. The GGBS is very effective in the design and development of high-strength and high-performance concrete. This paper reviews the effect of GGBS on the workability, porosity, compressive strength, splitting tensile strength, and flexural strength of concrete.

유한요소해석을 활용한 비틀림 제어 확장앵커의 비선형 인장거동 특성 분석 (Nonlinear Tensile Behavior Analysis of Torque-controlled Expansion Anchors Using Finite Element Analysis)

  • 방진수;윤일로;권양수;임홍재
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권4호
    • /
    • pp.91-99
    • /
    • 2020
  • 콘크리트용 앵커볼트는 콘크리트 구조물에 대한 비구조요소의 정착에 주로 사용되고 있으며, 시공성의 이점에 따라 후설치앵커가 주로 사용되고 있다. 앵커의 저항 성능과 관련하여 콘크리트 쪼개짐 영향을 최소화하기 위한 위험 연단거리가 제시되고 있지만 실제 앵커의 경우 이상적인 연단거리를 확보하기 어렵다. 즉, 인장 하중에 따라 발생 가능한 콘크리트 쪼개짐 등 복합적인 요소가 포함된 앵커의 저항 성능과 인장 거동 특성을 파악하기 위함이 본 연구의 목적이다. 표준시험방법을 바탕으로 인장실험을 진행하고 도출된 하중-변위 결과 및 파괴 형상을 분석하였다. 위험 연단거리가 확보되지 않은 앵커의 경우 인장력에 의해 콘크리트 쪼갬 파괴가 동반된 파괴 모드가 도출되고 저항 특성은 강성 구간으로 분류된다. 또한, 실험체 구성 요소를 바탕으로 비선형 유한요소모델을 구성하였으며, 앵커 거동을 모사하기 위해 구속 조건 및 연결요소 조건에 따른 경계조건별 변수 해석을 수행하였다. 이에 따라 도출된 해석 결과는 콘크리트 내부 파괴 영향성 및 실제 앵커의 거동을 바탕으로 검증하여 범용구조해석 프로그램 내 경계조건을 통한 저항 메커니즘 적용이 가능한 것으로 판단된다.

음향방출을 이용한 일방향 탄소섬유강화 플라스틱의 손상평가에 관한 연구 (A Study on the Damage Estimation of Uni-directionally Oriented Carbon Fiber Reinforced Plastics using Acoustic Emission)

  • 이장규;박성완;김봉각;우창기
    • 한국공작기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.30-36
    • /
    • 2005
  • This study is to investigate a damage estimation of single edge notched tensile specimens as a function of acoustic emission(AE) according to the uni-directionally oriented carbon fiber/epoxy composites, CFRP In fiber reinforced composite materials, AE signals due to several types of failure mechanisms are typically observed. These are due to fiber breakage, fiber pull-out matrix cracking, delamination, and splitting or fiber bundle breaking. And these are usually discriminated on the basis of amplitude distribution, event counts, and energy related parameters. In this case, AE signals were analyzed and classified 3 regions by AE event counts, energy and amplitude for corresponding applied load. Bath-tub curve shows 3 distinct periods during the lifetime of a single-edge-notch(SEN) specimen. The characterization of AE generated from CFRP during SEN tensile test is becoming an useful tool f3r the prediction of damage failure or/and failure mode analysis.

Formula to identify the Influence of steel fibres on the mechanical properties of HPC

  • Philip, Nivin;Anil, Sarah
    • Computers and Concrete
    • /
    • 제25권5호
    • /
    • pp.479-484
    • /
    • 2020
  • This work performed to analyses the impact of hooked end steel fibres on the mechanical properties of high performance concrete. The mechanical properties considered incorporate compressive strength, split tensile strength and flexural strength. Taking in to thought parameters, such as, volume fraction of fibres, fibre aspect ratio and grade of concrete, a logical strategy called Taguchi technique was utilized to discover the ideal blend of factors. L9 Orthogonal Array (OA) of Taguchi network comprising of three variables and three dimensions is utilized in this work. The evaluations of concrete considered were M60, M80 and M100. M60 contained 15% of metakaolin as bond swap though for M80 it was 5% of metakaolin and for M100 it was 10% metakaolin and 10% of silica smolder. The volume portion of fiber was fluctuated by 0.5%; 1% and 1.5% and the viewpoints proportions considered were 50, 60 and 80. The test outcomes demonstrate that incorporation of steel fibres enhance significantly the the strength characteristics of concrete, predominantly the splitting tensile strength and flexural strength. In light of relapse investigation of the test information scientific models were produced for compressive strength, split tensile strength and flexural strength of the steel fibre-reinforced high performance concrete.

Influence of loading condition and reinforcement size on the concrete/reinforcement bond strength

  • Turk, Kazim;Caliskan, Sinan;Sukru Yildirim, M.
    • Structural Engineering and Mechanics
    • /
    • 제19권3호
    • /
    • pp.337-346
    • /
    • 2005
  • The paper reports on a study of bond strength between reduced-water-content concrete and tensile reinforcement in spliced mode. Three different diameters (12, 16 and 22 mm) of tensile steel were spliced in the constant moment zone, where there were two bars of same size in tension. For each diameter of reinforcement, a total of nine beams ($1900{\times}270{\times}180mm$) were tested, of which three beams were with no axial force (positive bending) and the other six beams were with axial force (combined bending). The splice length was selected so that bars would fail in bond, splitting the concrete cover in the splice region, before reaching the yield point. It was found that there was a considerable size effect in the experimental results, i.e., as the diameter of the reinforcement reduced the bond strength and the deflection recorded at the midspan increased significantly, whilst the stiffness of the beams reduced. It was also found for all reinforcement sizes that higher bond strength and stiffness were obtained for beams tested in combined bending than that of the beams tested in positive bending only.

초기재령에서 콘크리트 인장균열에 대한 쌍선형 응력-균열 개구 관계의 변화 (Variation of Bilinear Stress-Crack Opening Relation for Tensile Cracking of Concrete at Early Ages)

  • 권승희;최강;이윤;박홍용
    • 콘크리트학회논문집
    • /
    • 제22권3호
    • /
    • pp.427-435
    • /
    • 2010
  • 인장 균열은 콘크리트의 가장 취약한 특성으로 수화열 및 건조수축 등으로 인해 초기재령에서 발생되는 경우가 많다. 초기의 균열을 정확히 예측하기 위해서는 응력-균열 개구 관계가 시간에 따라 어떻게 변화하는 지를 파악해야 한다. 이 연구에서는 기존에 수행되었던 쐐기형 쪼갬 실험결과에 대한 역해석을 수행하였으며, 측정된 하중-균열 개구 변위를 최적으로 모사하는 응력-균열 개구 관계에 대한 쌍선형 연화곡선을 구하였다. 파괴에너지의 시간에 따른 변화에 관한 분석이 이루어졌으며, 분석 결과를 바탕으로 초기재령에서의 응력-균열 개구 관계에 대한 모델을 제안하였다. 최대 하중, 최대 하중에서의 균열 개구 변위, 파괴에너지에 대하여 실험 측정값, 역해석 결과, 모델로부터 계산된 결과들을 비교해 보았으며, 이를 통해 제안된 모델을 검증하였다.

제강슬래그 골재의 소파블록 적용성 평가 (Applicability of Steel Slag Aggregate for Artificial Armor Unit)

  • 양은익;이광교;한상훈
    • 콘크리트학회논문집
    • /
    • 제16권5호
    • /
    • pp.591-596
    • /
    • 2004
  • 제강슬래그 골재의 소파블록 적용성을 평가하기 위하여, 구조적 재료로서의 콘크리트 물성을 연구하였다. 또한, 제강슬래그 골재를 사용한 해양 콘크리트의 생물학적 연구를 수행하였다. 수행된 콘크리트의 물성 실험은 슬럼프, 공기량, 압축강도, 쪼갬인장강도, 탄성계수, 탄산화 저항성, 수화열, 동결융해, 황산염 침지, 건조수축 실험 등이다. 또한, 해양 저서생물과 해조류의 번식 및 증식에 대한 조사를 위해 생물학적 실험이 수행되었다. 본 연구결과에 따르면, 제강슬래그 골재의 함유는 압축강도, 쪼갬인장강도, 그리고 탄성계수에 대하여 나쁜 영향을 미치지 않으며, 콘크리트의 내구성 측면에서도 제강슬래그 골재의 함유에 의한 악영향을 받지 않았다. 생물학적 연구에 따르면, 제강슬래그 골재는 해양 저서생물과 해조류의 증식과 번식에 이상적인 재료로서 평가되었다.

강섬유 계수 및 혼입률을 고려한 SFRC의 강도 및 변형 특성 (Characteristic Strength and Deformation of SFRC Considering Steel Fiber Factor and Volume fraction)

  • 이현호;이화진
    • 콘크리트학회논문집
    • /
    • 제16권6호
    • /
    • pp.759-766
    • /
    • 2004
  • 강섬유(steel fiber) 보강은 전단 강도와 같은 콘크리트 구조 부재의 많은 공학적 특성들을 현저히 향상시킨다. 본 연구는 구조 부재로의 실용적 사용을 위해 강섬유의 형상, 형상비, 혼입률, 강섬유 계수를 강도 특성 및 변형 특성의 수준으로 평가하였다. 기존 연구 및 본 연구의 재료 시험 결과들을 평가한 결과, 양단고리형 및 최대골재치수의 1.5배 이상되는 길이의 강섬유의 강도 보강효과가 우수한 것으로 판단된다. 또한 강도 및 변형 능력에 대한 상세 시험결과로부터, 형상비 75, 혼입률 $1.5\%$가 적절한 것으로 판단된다. 결론적으로 재료 성능 시험 결과들을 통계적로부터 추정한 결과, 강섬유 계수, 할렬인장강도, 휨강도가 SFRC의 주요한 특성인자로 판단된다.

폐비닐 골재가 혼합된 시멘트 콘크리트의 열 특성 (Thermal Characteristics of Cement Concrete Mixed with Wasted Vinyl Aggregates)

  • 염우성;안기홍;유주호;정진훈
    • 한국도로학회논문집
    • /
    • 제16권6호
    • /
    • pp.79-86
    • /
    • 2014
  • PURPOSES : In this study, wasted vinyl aggregate, which possesses better thermal properties than natural aggregate, was used in cement concrete mixture to develop more economical concrete with thermal insulation and freeze prevention effects. METHODS : Slump and air content of the fresh concrete, which substituted its 0%, 5%, and 10% of coarse aggregate with wasted vinyl aggregate, were measured. Compressive strength, Poisson's ratio, elastic modulus, and splitting tensile strength of hardened concrete were measured by laboratory tests. Thermal properties of concrete such as coefficient of thermal expansion, thermal conductivity, and specific heat were also measured according to replacement ratio of wasted vinyl aggregate. Finally, the thermal insulation and freeze prevention effectiveness of the concrete mixed with wasted vinyl aggregate was confirmed through finite element analysis of road pavement crossing above concrete box culvert made from wasted vinyl aggregate. RESULTS : Even though the physical properties of wasted-vinyl-aggregate concrete such as compressive strength, Poisson°Øs ratio, elastic modulus, and splitting tensile strength were inferior to those of ordinary concrete, they met requirements for structural concrete. The thermal properties of concrete were improved by wasted vinyl aggregate because it decreased thermal conductivity and increased specific heat of the concrete. According to the result of finite element analysis, temperature variation in pavement subgrade was mitigated by box culvert made from wasted-vinyl-aggregate concrete. CONCLUSIONS : Through the laboratory test and finite element analysis of this study, it was concluded that the concrete structures made from wasted vinyl aggregate showed thermal insulation and freeze prevention effects.

불포화 폴리에스터 수지를 이용한 고강도 폴리머 콘크리트의 역학적 특성 (Mechanical Properties of High Strength Polymer Concrete Using Unsaturated Polyester Resin)

  • 연규석;김관호;이필호;김동수;박윤제
    • 콘크리트학회지
    • /
    • 제6권3호
    • /
    • pp.131-141
    • /
    • 1994
  • 이 연구는 불포화 폴리에스터 수지를 이용한 고강도 폴리머 콘크리트를 제조하여 구성재료와 첨가제의 변화에 따른 역학적 특성을 실험적으로 구명한 것이다. 그 결과 제조된 폴리머 콘크리트는 재령7일에서 압축강도$1,291~1,445kg/cm^2$, 할열인장강도 $106~145kg/cm^2$, 휨강도 $182~235kg/cm^2$를 발현하였으며, 이들에 대한 탄성계수 및 포아슨비를 구해 보았던 바 $2.8~3.8{\times}10^5\;kg/cm^2$, 0.21~0.32였고, 최대압축변형도는 0.005~0.0065로서 시멘트 콘크리트에 비해 매우 크게 나타났다.