• Title/Summary/Keyword: splice method

Search Result 107, Processing Time 0.029 seconds

Development of Non-Shrink Mortar Grouting Type Splice Sleeve (무수축 모르타르 충진형 슬리브 개발)

  • Lee, Young-Ho;Song, Jae-Joon;Cho, Jae-Young;Kim, Do-Hak
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.67-73
    • /
    • 2011
  • This study aims to develop an economical precast hollow concrete column with high constructability which consists of only splice sleeve and general reinforcing bar without using PC tendons in order to reduce the construction period and cost. With this purpose, this study performed the finite element analysis and tension test by using some variables such as length of sleeve, diameter of rebar and curing method for suggesting a grouting type splice sleeve which is a new type joint rebar and developing an optimized splice sleeve. As a result, the analysis on the tension performance of splice sleeve did not show any destruction caused by pull-out in reinforcing bar but it only occurred destruction of tension bar or bolt shear rupture from the mechanical defect of sleeve. Therefore, the experiment showed high performance in tension of the suggested splice sleeve and verified the application of precast hollow concrete column.

A Study on the Mechanical Properties of Gas Pressure Welded Splices of Deformed Reinforcing Bar (가스압접 이형철근의 기계적 강도 특성 연구)

  • Jeon, Juntai
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.4
    • /
    • pp.520-526
    • /
    • 2015
  • Reinforcing bar splices are inevitable in reinforced concrete structure. In these days, there are three main types of splices used in reinforced concrete construction site - lapped splice, mechanical splice and welded splice. Low cost, practicality in construction site, less time consuming and high performance make gas pressure welding become a favorable splice method. However, reinforcing bar splice experiences thermal loading history during the welding procedure. This may lead to the presence of residual stress in the vicinity of the splice which affects the fatigue life of the reinforcing bar. Therefore, residual stress analysis and tensile test of the gas pressure welded splice are carried out in order to verify the load bearing capacity of the gas pressure welded splice. The reinforcing bar used in this work is SD400, which is manufactured in accordance with KS D 3504. The results show that the residual stresses in welded splice is relatively small, thus not affecting the performance of the reinforcing bar. Moreover, the strength of the gas pressure welded splice is high enough for the development of yielding in the bar. As such, the reinforcing bar with gas pressure welded splice has enough capacity to behave as continuous bar.

Development of a Root-Removed Splice Grafting System for Cucurbitaceous Vegetables (1) - Analysis of Grafting Process and System Setting - (박과채소용 단근합접 접목시스템 개발(1) -작업공정 분석과 시스템 설정 -)

  • Kang, C.H.;Lee, S.K.;Han, K.S.;Lee, Y.B.;Choi, H.K.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.453-461
    • /
    • 2008
  • This study was conducted to develop a root-removed splice grafting system for cucurbitaceous vegetables, mainly watermelon and cucumber seedlings, for the seedlings factories where currently most of seedlings grafting works are carried out by manual works. The major results of the study are as follows. The dimensions of rootstocks and scions, except cotyledon width, of root- removed splice grafting of watermelon and cucumber were shown to be varied within the 2.5-fold range. The growth status of seedlings were not consistent in terms of cotyledon sprouting direction and angle which were considered as one of the important factors for in root-removed splice grafting. The grafting work of root-removed splice for grafted watermelon and cucumber could be divided by four sub-operations: seedling supplying, cutting, clipping and potting, while a part or all root of the rootstock was removed in the seedlings supplying operation. The cutting angles of the rootstock and scion were $34-45^{\circ}$ and $20-45^{\circ}$, respectively, while the stem length of the scion varied from 6 mm to 12 mm. The splices of rootstock and scion were heaped up in parallel and then fixed by a clip. It indicated that the ideal grafting system, adopting conventional grafting processes of seedlings specifications as well as conventionally manual root-removed splice grafting method, performed very well for seedlings gripping and transporting, supplying clip, clipping and discharging grafted seedlings while workers supplied seedlings to the semi-automatical system.

Development of Steel Pipe Splice Sleeve for High Strength Reinforcing Bar(SD500) and Estimation of its Structural Performance under Monotonic Loading (SD500 고강도 철근용 강관 스플라이스 슬리브 철근이음 개발 및 구조성능 평가)

  • Lee, Sang-Ho;Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.6
    • /
    • pp.169-180
    • /
    • 2007
  • Among several splicing system of reinforcing bar, the grout-filled splice sleeve system has been applied widely. However, as the splice sleeve for high strength rebar as SD500 is not yet made in korea, the development of splice sleeve for high strength reinforcing bar are required as soon as possible. It is the purpose of this study to develop the steel pipe sleeve for high strength rebar as SD500 and estimate its structural performance by monotonic loading test. The experimental variables adopted in this study are the development length of rebars, types of sleeve etc. The results of this study showed that the developed steel pipe splice sleeve system for high strength reinforcing bar as SD500 retained the structural performance required in domestic, ACI and AIJ criteria. And it is considered that the study result presented in this paper can be helpful in developing reasonable design method of steel pipe splice sleeve system for high strength reinforcing bar as SD500.

Work limit Load Efficiency According to Splicing Method for Hand Spliced Wirerope Sling (스플라이스식 와이어로프 슬링의 편입법에 따른 사용하중한계효율)

  • Park, Jae-Suk;Han, Kyoung-Hun
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.70-74
    • /
    • 2010
  • For each strand of wirerope sling, the international standards, ISO-8794, EN-13414 specify that the splice shall have five series of load carrying tucks. At least three of the load carrying tucks shall be made with the whole strand. And, the breaking force of the splice shall not be less than 70% or 80% of that of rope. But, There are no prescriptions for splicing types against different efficiency of each splicing type being used many workplace. In this study, analysis the work limit load efficiency according to variation of number of tucks and splicing types by experimental method As a result, the number of tucks 3+2 had the highest breaking efficiency.

Experimental Studies on Bond and Splice Performance of Splice Sleeve for Connecting Rebar (철근연결용 스플라이스 슬리브의 이음 및 부착성능에 대한 실험적 연구)

  • Kang, Duk Man;Park, Yong Gul;Lee, Hyeon Gi;Moon, Do Young
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.257-264
    • /
    • 2017
  • The PC (Precast Concrete) construction method is a technique where concrete members that have been produced in a plant are constructed on site. Thus, continuity and secure integration of a structure that can be obtained by connecting rebars at splicing joint for PC members are the main areas of concern for this method. To evaluate the splicing and bonding performance according to application of a splice sleeve for connecting rebar in this research study, the diameter of rebar, development length, grouting strength etc. were set as variables. The performance and stiffness of splicing according to the development length of grout strength were measured and evaluated. In addition, by conducting comparative analysis on each of the variables, the factors that affected the splice sleeve for connecting rebar were discussed. The results confirmed that the strength and stiffness of the splice sleeve for connecting rebar were significantly affected by the development length while the increase in performance according to grout strength was not as significant.

Cyclic testing of weak-axis column-tree connections with formation of plastic hinge at beam splice

  • Oh, Keunyeong;Chen, Liuyi;Hong, Sungbin;Yang, Yang;Lee, Kangmin
    • Earthquakes and Structures
    • /
    • v.8 no.5
    • /
    • pp.1039-1054
    • /
    • 2015
  • The purpose of this study was to evaluate the seismic performance of weak-axis column-tree type connections used in steel moment frames. These connections are composed of a shop-welded and fieldbolted steel structure and can improve welding quality. On this basis, column-tree type connections are widely used in steel moment resisting frames in Korea and Japan. In this study, splices designed with a semirigid concept regarding the seismic performance of column-tree connections were experimentally evaluated. The structures can absorb energy in an inelastic state rather than the elastic state of the structures by the capacity design method. For this reason, the plastic hinge might be located at the splice connection at the weak-axis column-tree connection by reducing the splice plate thickness. The main variable was the distance from the edge of the column flange to the beam splice. CTY series specimens having column-tree connections with splice length of 600 mm and 900 mm were designed, respectively. For comparison with two specimens with the main variable, a base specimen with a weak-axis column-tree connection was fabricated and tested. The test results of three full-scale test specimens showed that the CTY series specimens successfully developed ductile behavior without brittle fracture until 5% story drift ratio. Although the base specimen reached a 5% story drift ratio, brittle fracture was detected at the backing bar near the beam-to-column connection. Comparing the energy dissipation capacity for each specimen, the CTY series specimens dissipated more energy than the base specimen.

Elasto-Plastic Behavior of Steel Beams with High Strength Bolted Splices (고력볼트 접합이음 철골보의 탄소성거동)

  • Choi, Sung Mo;Kim, Jin Ho;Roh, Won Kyoung
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.5 s.66
    • /
    • pp.531-539
    • /
    • 2003
  • Unlike field-welded moment frames damaged during the Northridge earthquake, a column-tree moment frame has a tool to control and reduce its seismic behavior. The tool is the girder splice. Girder splices could be designed to be sufficiently ductile and to have a prescribed bending moment capacity. In such a design, during earthquakes, the girder splices would act as ductile "fuses" and limit the magnitude of forces including the bending moment that could be developed in the frame. In Korea, most moment frames arc composed of a column-tree moment frame. Therefore, the elasto-plastic behavior of steel beams with high strength bolted friction splice should be clarified. Furthermore, structural capacities, including energy absorption capacity, must be quantitatively found. This paper discusses an experimental study to clarify elasto-plastic behavior of steel beams with high strength bolted friction splices. A total of 5 specimens were tested. A specimen was fabricated to have a beam splice designed by a full strength method. Other specimens were fabricated to have beam splices with 75%, 50% and 0% capacities compared with the specimen.

Lateral stiffness of corner-supported steel modular frame with splice connection

  • Yi-Fan Lyu;Guo-Qiang Li;Ke Cao;Si-Yuan Zhai;De-Yang Kong;Xuan-Yi Xue;Heng Li
    • Steel and Composite Structures
    • /
    • v.48 no.3
    • /
    • pp.321-333
    • /
    • 2023
  • This paper proposes a comprehensive investigation on lateral stiffness of corner-supported steel modular frame using splice connection. A full-scale modular frame with two stacked steel modules under lateral load is tested. Ductile pattern in the transfer of lateral load is found in the final failure mode. Two types of lateral stiffness, including tangent stiffness and secant stiffness, are defined from the load-displacement due to the observed nonlinearity. The difference between these two types of stiffness is found around 20%. The comparisons between the experimental lateral stiffness and the predictions of classical methods are also conducted. The D-value method using hypothesis of independent case is a conservative option for predicting lateral stiffness, which is more recommended than method of contraflexural bending moment. Analyses on two classical short-rod models, including fix-rod model and pin-rod model, are further conducted. Results indicate that fix-rod model is more recommended than pin-rod model to simplify splice connection for simulation on lateral stiffness of modular frame in elastic design stage.

The Structure and The Reason for Nuclear Accumulation of Poly A(-) Spliced SV40 RNA (Poly A tail이 없는 SV 40 spliced RNA의 구조 및 핵내 축적의 원인)

  • 박주상;노정혜
    • Korean Journal of Microbiology
    • /
    • v.27 no.1
    • /
    • pp.1-9
    • /
    • 1989
  • The locations of 5' ends as well as the splicing pattern of viral poly A(-) 19S RNA from monkey cells infected with SV40 were determined by a modification of primer extension method. The 5' end of this RNA mapped at the major cap site at nucleotide residue 325, used most frequently by SV40 late RNAs. The intron from nt.373 to nt.558 was removed as the ordinary cytoplasmic poly A(+) 19S RNA. The 3'end of this RNA was very heterogeneous and distributed over 1 kb upstream of polyadenylation site, as determined by S1 nuclease mapping. The reason for this normally initiated and spliced RNA to accumulate in the nucleus was investigated. In order to test whether the presence of unused 3' splice region on this RNA caused such subcellular distribution, cells were transfected with SV40 mutant KNA containing deletion around 3' splice site. The RNA deleted of 3' splice region accumulated mainly in the cytoplasm. This accumulation did not result from the increased stability of the RNA due to the deletion, since the wild type and mutant RNAs exhibited similar half lives after chase with actinomycin D. Therefore it is likely that the 19S spliced RNA is hindered from being transported into the cytoplasm due to some pre-splicing complexes formed at the unused 3' splice site.

  • PDF