• 제목/요약/키워드: splice connection part

검색결과 9건 처리시간 0.023초

A new replaceable fuse for moment resisting frames: Replaceable bolted reduced beam section connections

  • Ozkilic, Yasin O.
    • Steel and Composite Structures
    • /
    • 제35권3호
    • /
    • pp.353-370
    • /
    • 2020
  • This paper describes a new type of replaceable fuse for moment resisting frames. Column-tree connections with beam splice connections are frequently preferred in the moment resisting frames since they eliminate field welding and provide good quality. In the column-tree connections, a part of the beam is welded to the column in the shop and the rest of the beam is bolted with the splice connection in the field. In this study, a replaceable reduced beam section (R-RBS) connection is proposed in order to eliminate welding process and facilitate assembly at the site. In the proposed R-RBS connection, one end is connected by a beam splice connection to the beam and the other end is connected by a bolted end-plate connection to the column. More importantly is that the proposed R-RBS connection allows the replacement of the damaged R-RBS easily right after an earthquake. Pursuant to this goal, experimental and numerical studies have been undertaken to investigate the performance of the R-RBS connection. An experimental study on the RBS connection was used to substantiate the numerical model using ABAQUS, a commercially available finite element software. Additionally, five different finite element models were developed to conduct a parametric study. The results of the analysis were compared in terms of the moment and energy absorption capacities, PEEQ, rupture and tri-axiality indexes. The design process as well as the optimum dimensions of the R-RBS connections are presented. It was also demonstrated that the proposed R-RBS connection satisfies AISC criteria based on the nonlinear finite element analysis results.

케이블 연결 소켓의 인장강도 (Tensile Strength on Connection Socket of Cables)

  • 박강근;이장복;하채원;김재봉
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.37-42
    • /
    • 2008
  • 구조물에서 케이블 부재는 압축이나 휨이 없이 인장력에 의해서 하중을 전달하는 시스템이다. 케이블 시스템은 대공간 구조의 지붕, 공기 지지구조, 프리스트레스 막구조, 케이블 네트워크 구조, 현수구조, 가이드 타워, 해양 프래트폼, 현수교 등의 구조물에 널리 사용되어 왔다. 케이블 부재는 부재 단부에 소켓, 스웨이징, 스프라이스 슬리브, 클립, 웨지, 루프 스프라이스 등에 의해서 하중을 전달 할 수 있다. 본 연구에서는 케이블 연결 소켓의 인장강도에 대한 실험을 수행하고자 한다. 실험결과에서 대부분의 시험체가 케이블이 파단하중에 도달하기 전에 소켓의 연결부에서 파단이 일어났다.

  • PDF

고강도 강섬유보강콘크리트를 적용한 프리캐스트 바닥판 이음부의 구조성능 평가 (Evaluation on Structural Performance of Precast Bridge Deck Joint using HSFRC)

  • 이한주;정철헌;신동호;박세진;김인규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권6호
    • /
    • pp.196-205
    • /
    • 2017
  • 프리캐스트 바닥판 공법은 바닥판간 이음부가 존재하며, 이음부의 연결성능에 따라 전체 교량 구조물의 성능이 좌우되므로 이음부의 연결성능 확보가 중요한 요소이다. 본 연구에서는 고강도 강섬유보강콘크리트(High Strength Fiber Reinforced Concrete, HSFRC)가 적용된 비대칭 요철형 이음단면을 갖는 연결형식을 제안하였으며, 이음부의 단면형태, 철근 겹침이음길이 및 겹침이음 형식에 따른 구조실험을 수행하여 제안된 연결형식의 휨 성능을 평가하였다. 실험결과, 이음부 상세에 관계없이 이음철근은 항복변형률 수준의 인장변형을 나타내었으며, 제안된 연결형식은 충분한 휨 저항성능을 확보하는 것으로 나타났다. 이러한 실험결과는, 현행 도로교설계기준의 최소 겹침이음길이에 대한 규정은 이음부 채움재로 HSFRC를 적용한 프리캐스트 바닥판 이음부에서는 보수적인 규정임을 알 수 있다. 따라서 이음부 채움재로 HSFRC를 사용함에 의해 철근 겹침이음 상세의 단순화 및 이음부 폭의 감소가 가능하며, 제안된 연결형식은 프리캐스트 바닥판 이음부에 효과적으로 적용 가능할 것으로 판단된다.

고강도 모르타르 충전식 철근이음의 구조성능에 관한 실험연구 (Structural Performance of High Strength Grout-Pilled Splice Sleeve System)

  • 김형기;안병익;남재현;박복만
    • 콘크리트학회논문집
    • /
    • 제13권5호
    • /
    • pp.516-524
    • /
    • 2001
  • 여러가지 철근이음 방법중에서 고강도 모르타르 충전식 철근이음은 철근위치의 오차를 쉽게 흡수하여 시공이 용이하고 또한 최근에 많이 사용되고 있는 대구경 철근에 대해서도 적용성이 양호하기 때문에 프리캐스트 공법의 철근이음 방법으로 매우 유효한 수단이 된다. 이에 본 연구에서는 모르타르 충전식 철근이음법의 적용범위를 보다 확장하기 위하여 슬리브에 매입되는 철근직경이 상이한 경우와 충전 모르타르 강도를 700kgf/$\textrm{cm}^2$대로 낮춘 경우의 모르타르 충전식 철근이음에 대한 단조 및 반복가력 구조성능 실험을 실시한 후에 기존 실험결과와의 비교 분석을 통하여 다음과 같은 결론을 얻었다. 충전 모르타르 압축강도가 증가할수록 전체적인 구조성능은 증가하는 경향을 나타내었고 충전 모르타르 압축강도가 700kgf/$\textrm{cm}^2$이상이고 철근정착길이가 6.5d 이상이면 A급(AIJ 철근이음 성능 판정기준) 이상의 구조성능을 보유하고 있는 것이 확인되었다. 또한 슬리브 양단에 매입되는 철근의 직경이 상이한 경우는 굵은 철근에 대응되는 슬리브를 사용해야 하고 매입되는 가는 철근은 굵은 철근보다 2단계까지 가는 것을 사용할 수 있다는 것이 확인되었다.

Modelling and experiment of semi rigid joint between composite beam and square CFDST column

  • Guo, Lei;Wang, Jingfeng;Zhang, Meng
    • Steel and Composite Structures
    • /
    • 제34권6호
    • /
    • pp.803-818
    • /
    • 2020
  • Semi-rigid connections with blind bolts could solve the difficulty that traditional high strength bolts were unavailable to splice a steel/composite beam to a closed section column. However, insufficient investigations have focused on the performance of semi-rigid connection to square concrete filled double-skin steel tubular (CFDST) columns. In this paper, a component model was developed to evaluate the mechanical behavior of semi-rigid composite connections to CFDST columns considering the stiffness and strength of column face in compression and column web in shear which were determined by the load transfer mechanism and superstition method. Then, experimental investigations on blind bolted composite joints to square CFDST columns were conducted to validate the accuracy of the component model. Dominant failure modes of the connections were analyzed and this type of joint behaved semi-rigid manner. More importantly, strain responses of CFDST column web and tubes verified that stiffness and strength of column face in compression and column web in shear significantly affected the connection mechanical behavior owing to the hollow part of the cross-section for CFDST column. The experimental and analytical results showed that the CFDST column to steel-concrete composite beam semi-rigid joints could be employed for the assembled structures in high intensity seismic regions.

도장이 필요없는 내후성강 박스거더 상부 플랜지외부면 방식제 주입을 통한 방식공법 연구 (The study on the protection method from corrosion by the sealant injection on the unpainted weathering steel top flange outer surface of box girder)

  • 송창영
    • Corrosion Science and Technology
    • /
    • 제13권4호
    • /
    • pp.139-144
    • /
    • 2014
  • In corrosion-sensitive area of exsisting unpainted weathering steel bridge with closed box girder structure. there are some serious local corrosion problems because of rain water or dew water which can not be solved by conventional maintenance method. These problems must be technically controled because of the influence on the safety of bridge. This study is the first stage of developing the economic corrosion control manual for these local corrosion problems. Through the injecting experiment of tar sealant into the crevice of mock-up equipment, it was proofed that the corrosive sealant can be useful to corrosion control at crevice of corrosion sensitive area.

밀폐 박스거더형 무도장 내후성강 교량의 부식취약부에 대한 방식대책 연구(I) (The anti-corrosion study on the corrosion-sensitive areas of unpainted weathering steel bridges with closed box girder(I))

  • 송창영;이의호;이제현;박현출;최재석;노영태
    • Corrosion Science and Technology
    • /
    • 제12권3호
    • /
    • pp.149-157
    • /
    • 2013
  • In corrosion-sensitive areas of exsisting unpainted weathering steel bridges with closed box girder structures. there are some serious local corrosion problems because of rain water or dew water which can not be solved by exsisting maintenance methods. These problems must be controled technically because of bad. influence on the safety of bridge. This study is the first stage of developing the economic corrosion control manual for these local corrosion problems. Through the injection of tar sealant into the crevice of mock-up equipment, it was prooved that the corrosive sealant can be useful to corrosion control at crevice of corrosion sensitive area.

밀폐 박스거더형 무도장 내후성강 교량의 부식취약부에 대한 방식대책 연구(II) (The anti-corrosion study on the corrosion-sensitive areas of unpainted weathering steel bridges with closed box girder(II))

  • 송창영;이의호;이제현;박현출;최재석;노영태
    • Corrosion Science and Technology
    • /
    • 제12권4호
    • /
    • pp.191-197
    • /
    • 2013
  • This study is the second stage of developing the corrosion control technical manual about unpainted weathering steel bridge with closed box girder structures. This paper contains selection of corrosive sealant to apply into crevice of upper flange, injecting test of sealant at mock-up equipment with various condition, evaluation of experiment result. Through the experiment of injection of sealants into crevice of mock-up equipment, it is proved that the tar sealant injecting corrosion control method is useful to protect corrosion at box girder upper flange corroded by remaning rain water with calcium chloride.

프리캐스트 세그먼트를 이용한 조립식 수로암거구조물의 역학적 거동 특성 (Mechanical behaviour of waterway culvert structure assembled by precast segments)

  • 이규필;황재홍;신휴성;홍세균
    • 한국터널지하공간학회 논문집
    • /
    • 제12권2호
    • /
    • pp.193-200
    • /
    • 2010
  • 암거구조물의 특성상 암거 표준도가 제정되어 실무에 활용되고 있다. 그러나 이는 암거구조물의 설계 및 시공성을 향상시킬 수 있으나, 다양한 현장조건에 부합하는 단면형상의 선정에 제약조건으로 작용하게 된다. 이러한 문제점을 해결하기 위하여 프리캐스트 세그먼트 조립을 통하여 다양한 형상의 암거구조물 시공이 가능한 현장 대응형 암거구조물 설계 및 시공기술을 개발하였다. 조립식 수로암거구조물의 구조적 특성상 프리캐스트 세그먼트의 연결부가 고정 또는 내부힌지 거동 여부에 따라 부재의 두께, 철근량 등이 변화하게 되며, 이는 시공성 및 경제성에 큰 영향을 미치게 된다. 따라서 본 연구에서는 세그먼트 연결부의 합리적인 모델링 기법 제시를 위하여 현장실험 및 수치해석을 수행하였다. 현장실험 및 수치 해석 분석 결과, 몰타르 충진식 슬라브를 이용한 슬라브, 벽체, 기초판 프리캐스트 세그먼트는 연결시공을 통하여 조립식 수로암거구조물은 일체화된 구조물로 거동하는 것으로 나타났다.