• Title/Summary/Keyword: spin factor

Search Result 129, Processing Time 0.031 seconds

The Effect of Coating Material of Copper-wire RF Coil on the Signal-to-Noise Ratio in MR Images (RF코일로 사용된 구리선 코팅재질이 자기공명영상에서의 신호대잡음비에 미치는 영향)

  • Lee, Hyeon-Seung;Moon, Hye-Young;Chang, Yong-Min;Hong, Kwan-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.171-176
    • /
    • 2009
  • Purpose : To investigate the effect of coating material in RF coil, which is one of main parts in MRI machine, on the Q-factor and SNR(signal-to-noise ratio) in MR images. Materials and Methods : RF coils with inner diameter of 1.7 mm were made by using copper wires coated with polyester, polyurethane, polyimide, polyamideimide, and polyester-imide, and by using copper wires in which coating materials had been removed. Q-factors of the RF coils were measured by network analyzer, and SNR values in the spin-echo MR images obtained by 600 MHz (14.1 T, Bruker DMX600) micro-imaging system for the coated and uncoated cases. Results : The measured SNRs were almost same for the RF coils with coat-removed copper wires, however SNRs and Q-factors were different for the coated cases depending on the coating material. They were maximized in the polyurethane-coated case in which the SNR was > 30% greater than polyester-coated case. Conclusion : We made solenoid-type RF coils which were easily used for MR micro-imaging in Bruker MRI probe. There was a significant coating-material dependence in the measured Q values and SNRs for the home-made RF coils. The study demonstrated that the choice of coating material of RF coil may be a critical factor in the MRI sensitivity based on SNR value.

  • PDF

High-resolution Spiral-scan Imaging at 3 Tesla MRI (3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상)

  • Kim, P.K.;Lim, J.W.;Kang, S.W.;Cho, S.H.;Jeon, S.Y.;Lim, H.J.;Park, H.C.;Oh, S.J.;Lee, H.K.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.108-116
    • /
    • 2006
  • Purpose : High-resolution spiral-scan imaging is performed at 3 Tesla MRI system. Since the gradient waveforms for the spiral-scan imaging have lower slopes than those for the Echo Planar Imaging (EPI), they can be implemented with the gradient systems having lower slew rates. The spiral-scan imaging also involves less eddy currents due to the smooth gradient waveforms. The spiral-scan imaging method does not suffer from high specific absorption rate (SAR), which is one of the main obstacles in high field imaging for rf echo-based fast imaging methods such as fast spin echo techniques. Thus, the spiral-scan imaging has a great potential for the high-speed imaging in high magnetic fields. In this paper, we presented various high-resolution images obtained by the spiral-scan methods at 3T MRI system for various applications. Materials and Methods : High-resolution spiral-scan imaging technique is implemented at 3T whole body MRI system. An efficient and fast higher-order shimming technique is developed to reduce the inhomogeneity, and the single-shot and interleaved spiral-scan imaging methods are developed. Spin-echo and gradient-echo based spiral-scan imaging methods are implemented, and image contrast and signal-tonoise ratio are controlled by the echo time, repetition time, and the rf flip angles. Results : Spiral-scan images having various resolutions are obtained at 3T MRI system. Since the absolute magnitude of the inhomogeneity is increasing in higher magnetic fields, higher order shimming to reduce the inhomogeneity becomes more important. A fast shimming technique in which axial, sagittal, and coronal sectional inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the inhomogeneity map is applied. For phantom and invivo head imaging, image matrix size of about $100{\times}100$ is obtained by a single-shot spiral-scan imaging, and a matrix size of $256{\times}256$ is obtained by the interleaved spiral-scan imaging with the number of interleaves of from 6 to 12. Conclusion : High field imaging becomes increasingly important due to the improved signal-to-noise ratio, larger spectral separation, and the higher BOLD-based contrast. The increasing SAR is, however, a limiting factor in high field imaging. Since the spiral-scan imaging has a very low SAR, and lower hardware requirements for the implementation of the technique compared to EPI, it is suitable for a rapid imaging in high fields. In this paper, the spiral-scan imaging with various resolutions from $100{\times}100$ to $256{\times}256$ by controlling the number of interleaves are developed for the high-speed imaging in high magnetic fields.

  • PDF

Change of Plantar Pressure Distribution according to Stance Patterns during Tennis Forehand (테니스 포핸드의 스탠스 유형에 따른 족저압력분포의 변화)

  • Lee, Tae-Keun;Kim, Seung-Jae;Choi, Ji-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.2
    • /
    • pp.185-196
    • /
    • 2005
  • Recently among several tennis techniques forehand stroke has been greatly changed in the aspect of spin, grip and stance. The most fundamental factor among the three factors is the stance which consists of open, square and closed stance and it is very important to know the patterns of plantar pressure distribution for the better understanding of forehand stroke. Therefore, the purpose of this study was to investigate the change of plantar pressure distribution according to close, square and open stance patterns during forehand stroke in tennis. Three high school tennis players were recruited for the study and required to perform forehand stroke five consecutive trials in the condition of open, square and close stance. The forehand strokes were filmed with two digital video cameras and measured with pedar system for plantar pressure. The plantar regions under the foot were divided into 3 regions, which were forefoot, midfoot, and rear foot.. In conclusion, the first hypothesis, "The plantar pressure of close stance during forehand stroke would be distributed more largely to the left foot.", was rejected and the result showed that The plantar pressure of close stance during forehand stroke was distributed transferring from right foot to left foot similar to square stance. The second hypothesis, "The plantar pressure of square stance during forehand stroke would be distributed transferring from right foot to left foot." was accepted. The third hypothesis, "The plantar pressure of open stance during forehand stroke would be distributed more largely to the right foot.", was accepted.

Study on Heterogeneous Structures and High-Frequency Magnetic Properties Amorphous CoZrNb Thin Films (비정질 CoZrNb 박막의 불균일 구조와 고주파 자기특성에 관한 연구)

  • 정인섭;허재헌
    • Journal of the Korean Magnetics Society
    • /
    • v.1 no.2
    • /
    • pp.31-36
    • /
    • 1991
  • Structural and compositional heterogeneities of sputter deposited, amorphous $Co_{87}Zr_{4}NB_{9}$ thin films were investigated using TEM and EDS with windowless detector. The films deposited with substrate bias and annealed in rotating magnetc field showed two amorphous phases of Co-rich region and (ZrNb)oxide-rich region, and revealed 'ultra-soft' magnetic properties. Revesible bias-responses and overdamped frequency responses, along with small Hc, Hk and Mr/Ms ratio, give the possibility of ultra-soft magnetic behavior fo CoZrNb thin films. We proposed the vortex type magnetization distribution in remanent state which was correlated with the thin film heterogeneity. Then, the ultra-soft characteristics of the compositionally heterogeneous films were explained by the spin vortices that minimized the total magnetostatic and exchange coupling energies.

  • PDF

Fabrication of Field Emission Device Using Carbon Nanotubes Synthesized by Thermal Chemical Vapor Deposition (열 화학 기상 증착법을 이용한 탄소 나노 튜브 전계 방출 소자의 제조)

  • Yu, W.J.;Cho, Y.S.;Choi, G.S.;Kim, D.J.;Kim, H.Y.;Yoon, S.K.
    • Korean Journal of Materials Research
    • /
    • v.13 no.5
    • /
    • pp.333-337
    • /
    • 2003
  • We report a new fabrication process for carbon nanotube field emitters with high performance. The key of the fabrication process is trim-and-leveling the carbon nanotubes grown in trench structures by employing a planarization process, which leads to a uniform distance from the carbon nanotube tip to the electrode. In order to enable this processing, spin-on-glass liquid is applied over the CNTs grown in trench to have them stubborn adhesion among themselves as well as to the substrate. Thus fabricated emitters reveal an extremely stable emission and aging characteristics with a large current density of 40 ㎃/$\textrm{cm}^2$ at 4.5 V/$\mu\textrm{m}$. The field enhancement factor calculated from the F-N plot is $1.83${\times}$10^{5}$ $cm^{-1}$ , which is a very high value and indicates a superior quality of the emitter originating from the nature of open-tip and high stability of the carbon nanotubes obtained new process.

Non-monotonic Size Dependence of Electron Mobility in Indium Oxide Nanocrystals Thin Film Transistor

  • Pham, Hien Thu;Jeong, Hyun-Dam
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.8
    • /
    • pp.2505-2511
    • /
    • 2014
  • Indium oxide nanocrystals ($In_2O_3$ NCs) with sizes of 5.5 nm-10 nm were synthesized by hot injection of the mixture precursors, indium acetate and oleic acid, into alcohol solution (1-octadecanol and 1-octadecence mixture). Field emission transmission electron microscopy (FE-TEM), High resolution X-Ray diffraction (X-ray), Nuclear magnetic resonance (NMR), and Fourier transform infrared spectroscopy (FT-IR) were employed to investigate the size, surface molecular structure, and crystallinity of the synthesized $In_2O_3$ NCs. When covered by oleic acid as a capping group, the $In_2O_3$ NCs had a high crystallinity with a cubic structure, demonstrating a narrow size distribution. A high mobility of $2.51cm^2/V{\cdot}s$ and an on/off current ratio of about $1.0{\times}10^3$ were observed with an $In_2O_3$ NCs thin film transistor (TFT) device, where the channel layer of $In_2O_3$ NCs thin films were formed by a solution process of spin coating, cured at a relatively low temperature, $350^{\circ}C$. A size-dependent, non-monotonic trend on electron mobility was distinctly observed: the electron mobility increased from $0.43cm^2/V{\cdot}s$ for NCs with a 5.5 nm diameter to $2.51cm^2/V{\cdot}s$ for NCs with a diameter of 7.1 nm, and then decreased for NCs larger than 7.1 nm. This phenomenon is clearly explained by the combination of a smaller number of hops, a decrease in charging energy, and a decrease in electronic coupling with the increasing NC size, where the crossover diameter is estimated to be 7.1 nm. The decrease in electronic coupling proved to be the decisive factor giving rise to the decrease in the mobility associated with increasing size in the larger NCs above the crossover diameter.

Invention of Ultralow - n SiO2 Thin Films

  • Dung, Mai Xuan;Lee, June-Key;Soun, Woo-Sik;Jeong, Hyun-Dam
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.281-281
    • /
    • 2010
  • Very low refractive index (<1.4) materials have been proved to be the key factor improving the performance of various optical components, such as reflectors, filters, photonic crystals, LEDs, and solar cell. Highly porous SiO2 are logically designed for ultralow refractive index materials because of the direct relation between porosity and index of refraction. Among them, ordered macroporous SiO2 is of potential material since their theoretically low refractive index ~1.10. However, in the conventional synthesis of ordered macroporous SiO2, the time required for the crystallization of organic nanoparticles, such as polystyrene (PS), from colloidal solution into well ordered template is typical long (several days for 1 cm substrate) due to the low interaction between particles and particle - substrate. In this study, polystyrene - polyacrylic acid (PS-AA) nanoparticles synthesized by miniemulsion polymerization method have hydrophilic polyacrylic acid tails on the surface of particles which increase the interaction between particle and with substrate giving rise to the formation of PS-AA film by simply spin - coating method. Less ordered with controlled thickness films of PS-AA on silicon wafer were successfully fabricated by changing the spinning speed or concentration of colloidal solution, as confirmed by FE-SEM. Based on these template films, a series of macroporous SiO2 films whose thicknesses varied from 300nm to ~1000nm were fabricated either by conventional sol - gel infiltration or gas phase deposition followed by thermal removal of organic template. Formations of SiO2 films consist of interconnected air balls with size ~100 nm were confirmed by FE-SEM and TEM. These highly porous SiO2 show very low refractive indices (<1.18) over a wide range of wavelength (from 200 to 1000nm) as shown by SE measurement. Refraction indices of SiO2 films at 633nm reported here are of ~1.10 which, to our best knowledge, are among the lowest values having been announced.

  • PDF

Improved Pyroelectric Characteristics of 0~3 $PbTiO_3$/P(VDF/TrFE) Composites Films for Infrared Sensing (적외선 감지를 위한 0~3 $PbTiO_3$/P(VDF/TrFE) 복합체 필름의 향상된 초전 특성)

  • Kwon, Sung-Yeol
    • Polymer(Korea)
    • /
    • v.35 no.5
    • /
    • pp.375-377
    • /
    • 2011
  • $PbTiO_3$/P(VDF/TrFE) 0~3 composites thin films with 0.10 and 0.13 of ceramic volume fraction factor have been fabricated by two-step spin coating technique and analyzed. 0~3 connectivity of $PbTiO_3$/P(VDF/TrFE) composites film was observed successfully by SEM micrography. The SEM picture confirmed 0~3 connectivity. And, in all the properties, 0~3 $PbTiO_3$/P(VDF/TrFE) composites film was superior to P(VDF/TrFE) copolymer. Therefore, with a good low-dielectric constant and a high pyroelectric coefficient, the composite thin films can be used for a new pyroelectric infrared sensor of higher performance.

3-D Kinematic Analysis According to Stance Patterns During Forehand Stroke in Tennis (테니스 포핸드 스트로크 동안 스탠스 조건에 따른 3차원 운동학적 분석)

  • Choi, Ji Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.105-115
    • /
    • 2005
  • Recently among several tennis techniques forehand stroke has been greatly changed in the aspect of spin, grip and stance. The most fundamental factor among the three factors is the stance which consists of open, square and closed stance. The purpose of this study was to investigate the relations between the segments of the body, the three dimensional anatomical angle according to open, close, and square stance patterns during forehand stroke in tennis. For the movement analysis three dimensional cinematographical method(APAS) was used and for the calculation of the kinematic variables a self developed program was used with the LabVIEW 6.1 graphical programming(Johnson, 1999) program. By using Eular's equations the three dimensional anatomical Cardan angles of the joint and racket head angle were defined. In conclusion, the first hypothesis, "In three dimensional maximum linear velocity of racket head would be significant difference among the stance patterns during forehand stroke in tennis" was rejected. The second hypothesis, "In three dimensional anatomical angular displacement of trunk would be significant difference among the stance patterns during forehand stroke in tennis" was rejected and the result showed that the internal-external rotation showed most important role among the three dimensional anatomical angular displacement of trunk The third hypothesis, "In three dimensional anatomical angular displacement of upperlimb would be significant difference among the stance patterns during forehand stroke in tennis" was rejected and the result showed that The three dimensional anatomical angular displacement of shoulder joint showed most important role in forehand stroke. Flexion-extension and internal-external rotation the open stance showed the largest angular displacement and is follwed by square stance and closed stance. The fourth hypothesis, "In three dimensional anatomical angular velocity of upperlimb would be significant difference among the stance patterns during forehand stroke in tennis" was rejected and the result showed that X-axis angular velocity and Z-axis angular velocity the square stance showed the largest angular velocity of the trunk and X-axis angular velocity and Y-axis angular velocity the closed stance showed the largest angular velocity of the shoulder joint.

Molecular Geometries and Electronic Structures of Methyl Pyropheophorbide-a and (Cationic) Tropolonyl Methyl Pyropheophorbides: DFT Calculation

  • Kim, Na-Ri;Kim, Su-Jin;Kim, Jin-Dong;Huh, Do-Sung;Shim, Young-Key;Choe, Sang-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.205-213
    • /
    • 2009
  • This study reports on the geometry optimizations and electronic structure calculations for methyl pyropheophorbide (MPPa), tropolonyl methyl pyropheophorbides (TMPPa, ITMPPa), and cationic tropolonyl methyl pyropheophorbides ($TMPPa^+{{\cdot}BF_4}^-,\;ITMPPa^+{{\cdot}BF_4}^-,\;TMPPa^+,\;and\;ITMPPa^+$) using Local Spin Density Approximation (LSDA/ 6-31G*) and the Restricted Hatree-Fock (RHF/6-31G*) level theory. From the calculated results, we found that substituted cationic tropolonyl groups have larger structural effects than those of substituted neutral tropolonyl groups. The order of structural change effects is $ITMPPa^+ > ITMPPa^+{{\cdot}BF_4}^-$ > ITMPPa, as a result of the isopropyl group. Because it is an electron-releasing group, the substituted isopropyl group electronic effect on a 3-position tropolone increases the Highest Occupied Molecular Orbital and Lowest Unoccupied Molecular Orbital (HOMO-LUMO) energy gap. It was constituted that the larger the cationic characters of these photosensitizers, the smaller the HOMOLUMO band gaps are. The orbital energies of the cationic systems and the ions are stronger than those of a neutral system because of a strong electrostatic interaction. However, this stabilization of orbital energies are counteracted by the distortion of chlorin macrocycle, which results in a large destabilization of chlorin-based compound HOMOs and smaller destabilization of LUMOs as shown in TMPPa (ITMPPa), $TMPPa^+{{\cdot}BF_4}^- (ITMPPa^+{{\cdot}BF_4}^-),\;and\;TMPPa^+\;(ITMPPa^+)$ of Figure 6 and Table 6-7. These results are in reasonable agreement with normal-coordinate structural decomposition (NSD) results. The HOMO-LUMO gap is an important factor to consider in the development of photodynamic therapy (PDT).