• 제목/요약/키워드: sphygmomanometer

검색결과 55건 처리시간 0.022초

슬관절 전치환술 후 만성기 여성 노인의 슬관절 신전근에 근에너지기법이 근력, 관절가동범위, 균형, 보행능력에 미치는 영향 (Effects of Muscle Energy Technique on Knee Extensor Muscle Strength, Knee Range of Motion, Balance, and Walking Ability in Elderly Women during the Chronic Phase after Total Knee Replacement)

  • 송형봉;박근홍
    • 대한정형도수물리치료학회지
    • /
    • 제27권2호
    • /
    • pp.55-67
    • /
    • 2021
  • Background: This study aimed to use the muscle energy technique (MET) with total knee replacement (TKR) during the chronic phase in a clinical setting and confirm its effects on the knee extensor strength and ROM, balance, and walking ability. Methods: A total of 20 female patients who underwent TKR 1~4 years ago were assigned to two groups (Control: Q setting exercise+general physical therapy, n=10; Exp: MET+general physical therapy, n=10). Interventions were performed three times a week for 4 weeks. The strength of the knee extensor was evaluated using an aneroid sphygmomanometer, and ROM was evaluated using degrees at the end range on active knee flexion. The main balance outcomes were evaluated using two standard scale (TSS) and timed up and go (TUG) test, whereas the walking ability was evaluated using the 10 meter walk test (10MWT). Results: Analysis showed that both groups had significant increases in strength, ROM, TSS, TUG, and 10MWT. Differences in all variables were significant between the control and Exp groups at the post-intervention evaluation (p<.05). However, no significant difference was observed in strength and TUG. Conclusion: Results of this study demonstrated that MET would help improve the strength, ROM, balance, and walking ability of patients with chronic TKR who want to enhance their abilities and performance in activities of daily living.

자동혈압계 점검을 위한 액추에이터 기반의 혈압 시뮬레이터 개발 (Development of An Actuator-Based Blood Pressure Simulator for Automatic Blood Pressure Monitor)

  • 김수홍;이승준;임문혁;박혜민;강민석;김건호;남경원
    • 대한의용생체공학회:의공학회지
    • /
    • 제45권1호
    • /
    • pp.49-55
    • /
    • 2024
  • Accurate measurement of blood pressure is essential for classifying an individual's disease, identifying blood pressure-related risks, and managing health. Due to the environmental and health hazards of mercury sphygmomanometers, automatic sphygmomanometers using the oscillometric method are widely used in hospitals as well as in general homes, and have established themselves as a practical standard sphygmomanometer. In this study, we developed a blood pressure simulator using an actuator that provides simulated pressure to an automatic blood pressure cuff. The developed blood pressure simulator adopts an arm-shaped cylindrical shape similar to the situation in which a person measures blood pressure with an automatic blood pressure monitor, and implements a method of transmitting pressure to the cuff using a pressure plate. Accuracy was evaluated through the mean and standard deviation of the difference with the commercialized blood pressure simulator BP PUMP 2, and reproducibility was confirmed using two automatic blood pressure monitors. The developed blood pressure simulator enables automatic blood pressure monitoring in a simple manner and also meets the evaluation standards for accuracy and reproducibility. In the future, as a standardized blood pressure simulator, it is expected to be of great help in evaluating and verifying the performance of automatic blood pressure monitors by supplementing precise hardware and software and building a blood pressure database.

한국인 맞춤형 혈압계 커프 블래더 (Blood Pressure Cuff Bladders Tailored For Koreans)

  • 황락훈;박우성;나승권
    • 한국통신학회논문지
    • /
    • 제38C권9호
    • /
    • pp.822-829
    • /
    • 2013
  • 고혈압은 임상 현장에서 매우 흔한 질환인데 그 유병률이 국제적으로 상승세를 보이고 있다. 고혈압의 폐해는 너무 많으며 여러 장기들에 영향을 미친다. 필요 시 보통 평생 동안 치료해야 한다. 한국질병관리본부에 따르면 고혈압 유병률이 날로 증가하고 있다. 2011 조사에서 성인 중 28.9%가 고혈압이었으며, 여자 보다 남자가 약간 더 높았다. 환자를 분류하고, 혈압관련 위험을 확인하고 그리고 치료법을 안내하는 데 있어 정확한 혈압 측정은 필수적이다. 혈압계의 정확도에 영향을 미치는 요인 중 블래더 크기의 일탈이 장비 에러의 주된 원인이 된다. 혈압을 정확히 측정하기 위해, 위 팔 중심의 둘레에 따른 올바른 크기의 블래더 사용은 필수적이다. 시중의 혈압계를 조사한 결과, 커프 블래더들이 국제 규격 ISO 81060-1:2007에서 권유된 크기와 다름을 알 수 있었다. 블래더가 클 경우 혈압이 더 낮게 나오고, 더 작을 경우 더 높게 나온다는 것은 잘 알려져 있다. 미)심장협회(AHA)가 권고하는 어른용 블래더의 크기는 17-25cm의 팔 둘레를 가진 작은 어른, 24-32 cm의 팔 둘레를 가진 어른, 32-42cm의 팔 둘레를 가진 대다수 어른, 그리고 42-50cm의 팔 둘레를 가진 비만 어른으로 구분 된다. 반면에 한국 어른의 팔 둘레는 23-31cm에 불과하므로 AHA의 어른용 블래더 한 가지에 해당한다. 23-31cm의 팔 둘레를 가진 한국 어른을 위한 블래더의 종류는 ISO 81060-1을 따를 경우 3 개의 블래더가 필요하다. 병원들은 어른 환자들을 위해 보통 하나 혹은 두 가지 크기의 서양식 커프를 사용한다. 이 때문에 일부 환자들은 정확한 혈압 측정을 기대할 수 없다. 한국인에서 취합한 인체치수 참조 데이터에 기초한 블래더의 크기는 한국에서 가장 정확한 혈압을 측정하는데 도움이 될 것이다.

컴퓨터를 이용한 정보제공이 관상동맥조영술 대상자의 검사 전 불안감소에 미치는 영향 (The Effect of an Information using Computer Orogram on the Reduction of Anxiety in Coron Angiogram Subjects)

  • 정경인;최순희
    • 한국간호교육학회지
    • /
    • 제9권1호
    • /
    • pp.115-125
    • /
    • 2003
  • This study was conducted to investigate whether a computer information offered in advance of the test would decrease anxiety degree in coronary angiogram subjects. The study design was a nonequivalent control group, none-synchronized design. The subjects of study were 53 patients who were admitted at C hospital in K city for coronary angiogram. The 53 subjects were assigned to experimental(25) and control(28) groups. The computer information set up by researcher was used as the experimental treatment and 10 minutes long. Spielberger's state anxiety scale translated by Kim and Shin(1978) and sphygmomanometer were used for data collection. The data were collected from July 1, 2000 to March 31, 2001, and analyzed by chi-square, paried t-test, t-test, ANCOVA, and Pearson's Correlation Coefficients using SPSS/PC+. The results of this study were summarized as follows : 1. The first hypothesis that 'post-test state anxiety score will be lower than pre-test state anxiety score in experimental group' was supported(t=2.40, p=.020). 2. The second hypothesis that 'post-test systole will be lower than pre-test systole in experimental group' was not supported(t=-.30, p=.765). 3. The third hypothesis that 'post-test Diastole will be lower than pre-test diastole in experimental group' was not supported'(t=-1.42, p=.161). 4. The fifth hypothesis that 'the experimental group who is given the computer information will be lower in state anxiety score than the control group who is not given the computer information' was supported(F=9.17, p=.004). 5. The sixth hypothesis that 'the experimental group who is given the computer information will be lower in systole than the control group who is not given the computer information' was supported (F=7.16, p=.010). 6. The seventh hypothesis that 'the experimental group who is given the computer information will be lower in diastole than the control group who is not given the computer information' was not supported'(F=.55, p=.462). 7. The eleventh hypothesis that 'the lower the post-test state anxiety, the lower the uneasiness score during the test' was not supported(r=-.013, p=.926). 8. The eighth hypothesis that 'the lower the post-test state anxiety, the lower the nervousness score during the test' was supported(r=.326, p=.017).

  • PDF

다중 생체 신호를 통한 손목 혈압 측정의 정확도 향상 (Improvement of the Accuracy of Wrist Noninvasive Blood Pressure Measurement Using Multiple Bio-signals)

  • 정운모;심명헌;정상오;김민용;윤찬솔;정인철;윤형로
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1606-1616
    • /
    • 2011
  • The blood pressure measuring equipment, which is being supplied and used most widely by being recognized convenience and accuracy now generally, is oscillometric blood pressure monitor. However, a change in blood pressure is basically influenced by diverse elements such as each individual's physiological status and physical condition. Thus, the measurement of blood pressure, which used single element called oscillation in blood pressure of being conveyed to cuff, is not considered on physiological elements such as cardiovascular system status and blood vessel stiffness index, and on external elements, thereby being quite in error. Accordingly, this study detected diverse bio-signals and body informations in each individual as the measurement subject such as ECG, PPG, and Korotkoff Sound in order to enhance convenience and accuracy of measuring blood pressure in the complex measurement equipment, thereby having extracted regression method for compensation in error of oscillometric blood pressure measurement on the wrist, and having improved accuracy of measuring blood pressure. To verify a method of improving accuracy, the blood pressure value in each of SBP, DBP, MAP was acquired through 4-stage experimental procedure targeting totally 51 subjects. Prior to experiment, the subjects were divided into two groups such as the experimental group for extracting regression method and the control group for verifying regression method. Its error was analyzed by comparing the reference blood pressure value, which was obtained through the auscultatory method, and the oscillometric blood pressure value on the wrist. To reduce the detected error, the blood pressure compensation regression method was calculated through multiple linear regression analysis on elements of blood pressure, individual body information, PTT, HR, K-Sound PSD change. Verification was carried out on improving significance and accuracy by applying the regression method to the data of control group. In the experimental results, as a result of confirming error on the reference blood pressure value in SBP, DBP, and MAP, which were acquired through applying regression method, the results of $-0.47{\pm}7.45$ mmHg, $-0.23{\pm}7.13$ mmHg, $0.06{\pm}6.39$ mmHg could be obtained. This is not only the numerical value of satisfying the sphygmomanometer reference of AAMI, but also shows the lower result than the numerical value in SBP : $-2.5{\pm}12.2$ mmHg, DBP : $-7.5{\pm}8.4$ mmHg, which is the mean error in the experimental results of Brram's research for verifying accuracy of Omron RX-M, which shows relatively high accuracy among wrist sphygmomanometers. Thus, the blood pressure compensation could be confirmed to be made within significant level.

무료함, 통증, 그리고 놀람 정서 간 자율신경계 반응의 차이 (Difference of Autonomic Nervous System Responses among Boredom, Pain, and Surprise)

  • 장은혜;음영지;박병준;김상협;손진훈
    • 감성과학
    • /
    • 제14권4호
    • /
    • pp.503-512
    • /
    • 2011
  • 최근 HCI 분야에서 정서 인식은 정서 지능을 구현하기 위한 핵심적인 단계 중의 하나이다. 생체신호를 이용하여 정서 인식을 시도하는 연구들이 시도되고 있으나, 기본 정서 이외의 다른 정서에 대한 연구는 거의 이루어지지 않았다. 본 연구의 목적은 무료함, 통증, 그리고 놀람의 세 가지 정서 간 자율신경계 반응의 차이를 확인하는 것이다. 실험자는 217명의 실험참여자(남 96명)들을 대상으로 시/청각 자극을 조합하여 무료함과 놀람 정서를 유발하였고, 혈압기를 이용하여 통증 정서를 유발하였다. 정서 자극이 제시되는 동안 피부전기활동, 피부온도, 심전도와 광혈량도를 측정하였고, 실험참여자들이 경험한 정서 범주와 강도를 정서평가척도 상에 평정하게 하였다. 정서 자극에 대한 평가 결과, 사용된 정서 자극은 평균 92.5%의 적합성과 5.43의 효과성을 보였는데, 이는 각 정서 자극이 해당 정서를 효과적으로 유발한 것을 의미한다. 자율신경계 측정 결과, 피부전기활동, 피부온도, 심박률, 심박률의 저주파수 성분과 평균 혈류량은 안정 상태와 정서 상태 간의 유의한 차이를 보였다. 또한 각 정서에 의해 유발된 자율신경계 반응은 정서 간에도 유의한 차이가 있는 것으로 나타났다. 이러한 결과는 정서이론의 확장과 자율신경계 반응 측정 지표를 활용하여 정서를 인식하는 알고리즘 및 인간 정서를 변별하는 컴퓨터 시스템 개발에 응용 가능할 것이다.

  • PDF

비침습적 혈압 측정 시스템 구현에 관한 연구 (A Study on Implemetation of Non-invasive Blood Pressure)

  • 노영아;이종수;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.451-454
    • /
    • 2000
  • 혈압을 측정하는 방법에는 침습적(Invasive)인 방법과 비침습적(Non-invasive)인 방법이 있는데 침습적인 방법에 의한 혈압측정의 경우 정확한 값을 얻는 반면에 그 사용법이 복잡하고 환자에게 불편하므로 중환자의 경우를 제외한 경우 대부분 비침습적인 방법에 의해 혈압을 측정한다. 현재 전자 혈압계의 경우 대부분이 오실로메트릭(Oscillometric) 방법을 사용하여 기본적인 시스템을 구성하고 여기에 여러 가지 알고리즘을 부가적으로 적용하고 있다. 본 연구에서 이러한 혈압 측정 시스템을 개발하기 위해 커프(Cuff)의 압력을 제어, 측정하고 측정된 데이터를 필터링하여 혈압을 측정할 수 있도록 알고리즘을 구성하였다. 통신방식으로는 개발된 시스템의 모든 기능이 개인용 컴퓨터(Personal Computer)와의 통신을 통해 이루어지도록 구성되어져 있으며, 사용된 통신방식은 비동기 직렬 통신 방식(RS-232)인 패킷방식을 사용하였고 솔레노이드(Solenoid) 밸브를 이용한 자동 또는 급속 배기 방법을 이용하여 커프의 압력을 감압(Deflation)하였다. 혈압측정 알고리즘은 기본적인 오실로메트릭 방법과 최대 진폭 알고리즘(Maximum Amplitude Algorithm)을 사용하였다. 최대진폭 알고리즘에서는 측정된 오실레이션(Oscillation)중 최고의 진폭을 가지는 오실레이션 같은 오차의 원인이 되는 연령이나 체중, 팔의 두께에 따라 다양하게 나타난다. 본 연구에서는 오실레이션의 간에 획일적인 비율을 적용하지 않고 여러 가지 요인들에 대한 가변적인 특정 비율(Characteristic Ratio)반영하여 보다 정확한 최고혈압(Systolic Blood Pressure), 최저혈압(Diastolic Blood Pressure), 평균혈압(Mean Blood Pressure)의 값을 구하는 연구를 하였다. 최고진폭 알고리즘에서 가변적인 특성비율의 적용은 혈압간의 오차를 줄일 수 있을것으로 기대된다.

  • PDF

측정 횟수 및 방문 횟수에 따른 혈압 변화 (The Change of Blood Pressure according to the Number of Measurements and the Number of Visits)

  • 박지은;이민희;류연희;류연;정희정;홍상훈;이승덕;김남권;최선미
    • 한국한의학연구원논문집
    • /
    • 제18권3호
    • /
    • pp.111-118
    • /
    • 2012
  • Objective : The aim of this study was to investigate the number of measurements and visits for blood pressure measurement. We also analyzed the change of blood pressure based on the measurement method and measurement interval. Methods : Data of three clinical trials evaluating the effect of acupuncture, moxibustion, and qigong for pre and mild essential hypertension were used. Blood pressure was measured 3 times each visit with 1 or 5 minutes interval, and it was checked until $3^{rd}$ visit. Two trials used sphygmomanometer and another one trial used automatic device for blood pressure measurement. Results : The mean difference between $1^{st}$ and $2^{nd}$, and $2^{nd}$ and $3^{rd}$ measurement were significant in systolic (p<0.001) and diastolic blood pressure (p<0.001). However, in automated measurement or measuring with 1 minute interval, the difference between $2^{nd}$ and $3^{rd}$ was not significant. The mean of $1^{st}$ and $2^{nd}$ measurements was also significantly different from the mean of all three measurements in both systolic (p<0.001) and diastolic blood pressure (p<0.001). While the difference between each visit was not significant in diastolic blood pressure, the systolic blood pressure difference was significant between $1^{st}$ and $2^{nd}$ visit in automated and manual measurement. Conclusion : The mean of two measurements and three measurements were significantly different. The change of blood pressure was different according to the method and interval of blood pressure measurement.

당뇨병 환자의 혈압 일주기 리듬에 관한 조사연구 (A Study on the Circadian Blood Pressure Rhythm of Diabetic Patients)

  • 김화순;서화숙
    • 대한간호학회지
    • /
    • 제30권3호
    • /
    • pp.741-749
    • /
    • 2000
  • This study was performed to investigate the relationship between reversed circadian blood pressure and risk factors of peripheral vascular disease in non-insulin-dependent diabetes mellitus (NIDDM) subjects. The subjects in this study were 18 NIDDM patients who were hospitalized in a medical unit of an university medical center located in Incheon, Korea, between November, 1998 and March, 1999. Blood pressure was measured with a mercury sphygmomanometer by 2 trained examiners every 2 hours during 24 hours. NIDDM subjects were divided into a dipper group and non-dipper group. Dippers are defined as those who show a mean nighttime blood pressure(BP) drop of more than 10% compared with daytime BP. Non-dippers are defined as those who show a mean nighttime BP drop of less than 10%, or an elevation in BP compared with daytime BP. Daytime BP included values obtained between 6 a.m. and 10 p.m. Night time BP included values obtained between 10 p.m. and 6 a.m. Data was analyzed by SPSS/PC package. Chi-square( $^2$) test was used for the comparison of sex between The dipper group and non-dipper group. Mann-Whitney test was used for comparisons of values of the risk factors of peripheral vascular disease and the frequency of complications of diabetes between the dipper group and non-dipper group. The results are as follows. There were no significant differences in daytime systolic, diastolic, and mean blood pressures between the dipper group and non-dipper group. However, night time systolic, diastolic, and mean blood pressures in the non-dipper group were significantly nigher than those in the dipper group (p=.021). There were no differences in sex, age, body, weight, duration of diabetes, serum lipid levels, BUN and HbA1c between the two groups. On the contrary, 87.5% of non-dipper group subjects showed having hypertension, 30% of dipper group subjects showed having hypertension and this difference was statistically significant (p=.018). All of the non-dipper group subjects (N=8) showed having at least one diabetic complication. However, 40% of the dipper group subjects (N=10) showed having no diabetic complication at all and this difference was also statistically significant (p=.049). There were no significant differences in frequency of nephropathy, neuropathy and retinopathy between the dipper group and non-dipper group.

  • PDF

Midazolam을 이용한 의식진정시 flumazenil의 투여경로에 따른 생징후 및 행동양상의 비교 연구 (A COMPARATIVE STUDY ON THE VITAL SIGN AND BEHAVIOR APPEARANCE DEPENDING ON THE ROUTE OF FLUMAZENIL ADMINISTRATION IN CONSCIOUS SEDATION BY MIDAZOLAM)

  • 김현식;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제29권2호
    • /
    • pp.159-167
    • /
    • 2002
  • 본 연구의 목적은 midazolam을 이용한 의식진정 시 길항제인 flumazenil의 투여경로에 따른 효과와 안전성을 평가하기 위함이다. 연구대상으로는 $22{\sim}24$세의 건강한 15명의 자원자를 이용하였으며, 그들은 midazolam 0.2mg/Kg을 비강내 분무하여 진정하였으며, midazolam 투여 40분 후 길항제인 flumazenil 0.2mg을 정맥 내 투여 및 비강 내 투여하였다. 각 투여경로의 안전성과 효과를 평가하기 위해 다음과 같은 관찰이 실시되었다. 대상의 생징후를 관찰하기 위해 pulse oxymeter(Nellcor symphony N-3000, Nellcor Puritan CO., USA)을 이용하여 $SaO_2$ 및 맥박수를 관찰하였고, 전자혈압계(Heartcare 200, National CO., Japan)을 이용하여 이완기 및 수축기 혈압을 관찰하였다. 또한 실험대상의 주관적 평가를 위해 visual analogue scale(VAS)를 이용하여, 진정, 수면, 피로 그리고 태도에 대해 주관적인 평가를 실시하였다. 모든 대상은 특이할 부작용없이 회복되었다. 연구결과를 요약하면 다음과 같다. 1. 비강내 분무된 flumazenil은 정맥내 투여된 flumazenil에 비해 빠른 회복을 보였으나, 곧이어 정맥내 투여에 비해 깊은 수면상태에 빠졌다. 2. 비강내 투여된 flumazenil 및 정적내 투여된 경우 모두 주의할 부작용 및 생징후의 악화는 관찰되지 않았다. 회복의 목적으로 비강내 분무된 flumazenil의 결과로 미루어 볼 때, midazolam을 이용한 의식진정시 flumazenil의 비강 내 분무를 통해 보다 안전하고, 효과적인 의식진정하 치과치료가 가능하리라 사료된다. 하지만, flumazenil의 적절한 용량 및 효과를 알기위해, midazolam과 flumazenil의 혈장농도를 평가하는 약물동력학적 연구가 계속되어야 하리라 사료된다.

  • PDF