• Title/Summary/Keyword: spectrum imaging

Search Result 300, Processing Time 0.035 seconds

Selection on Optimal Bands to EstimateYield of the Chinese Cabbage Using Drone-based Hyperspectral Image (드론 기반 초분광 영상을 이용한 배추 단수 추정의 최적밴드 선정)

  • Na, Sang-il;Park, Chan-won;So, Kyu-ho;Ahn, Ho-yong;Lee, Kyung-do
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.3
    • /
    • pp.375-387
    • /
    • 2019
  • The use of drone-based hyperspectral image offers considerable advantages in high resolution remote sensing applications. The primary objective of this study was to select the optimal bands based on hyperspectral image for the estimation yield of the chinese cabbage. The hyperspectral narrow bands were acquired over 403.36 to 995.19 nm using a 3.97 nm wide, 150 bands, drone-based hyperspectral imaging sensor. Fresh weight data were obtained from 2,031 sample for each field survey. Normalized difference vegetation indices were computed using red, red-edge and near-infrared bands and their relationship with quantitative each fresh weights were established and compared. As a result, predominant proportion of fresh weights are best estimated using data from three narrow bands, in order of importance, centered around 697.29 nm (red band), 717.15 nm (red-edge band) and 808.51 nm (near-infrared band). The study determined three spectral bands that provide optimal chinese cabbage productivity in the visible and near-infrared portion of the spectrum.

Pulsatility Index in Different Modifications of Fontan Palliation: An Echocardiographic Assessment

  • Reza Shabanian;Parvin Akbari Asbagh;Abdullah Sedaghat;Minoo Dadkhah;Zahra Esmaeeli;Aliyeh Nikdoost;Manizheh Ahani;Mitra Rahimzadeh;Alireza Dehestan;Mohammad Ali Navabi
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.2
    • /
    • pp.99-108
    • /
    • 2022
  • BACKGROUND: Adding pulsation to the Fontan circulation might change the fate of patients palliated by this procedure. Our aim was to compare the pulsatility index (PI) of the pulmonary artery (PA) between the various modifications of Fontan palliation. METHODS: Doppler-derived PI was measured in PA branches of a cohort of 28 patients palliated by 6 modifications of Fontan procedure. A group of normal individuals was included for comparison. RESULTS: Atriopulmonary connection (APC) group had the highest PA branches PI and statistically was close to the PI of the normal individuals (right pulmonary artery [RPA] PI of 1.58 vs. 1.63; p = 0.99 and left pulmonary artery [LPA] PI of 1.54 vs. 1.68; p = 0.46, respectively). The lowest PA branches PI was seen in the group of extracardiac total cavopulmonary connection (RPA PI of 0.62 and LPA PI of 0.65). Other 4 modifications including the extracardiac conduit with oversewn pulmonary valve, extracardiac conduit with preserved adjusted antegrade flow, extracardiac conduit from inferior vena cava onto the rudimentary right ventricle and lateral tunnel had a mean "RPA and LPA" PI of "1.19 and 1.17", "1.16 and 1.11", "1.13 and 1.11", "0.82 and 0.84", respectively. The modified Dunnett's post hoc test has shown a significant statistical decline in PI of all modifications compared to the normal individuals except for the APC group. CONCLUSIONS: Fontan palliated patients in different groups of surgical modification showed a spectrum of Doppler-derived PI with the highest amounts belong to the groups of pulsatile Fontan.

Change of Dose Exposure and Improvement of Image Quality by Additional Filtration in Mammography (유방촬영용장치 부가필터에 따른 선량변화 및 화질개선)

  • Cho, Woo Il;Kim, Young Kuen;Lee, Gil Dong
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.78-90
    • /
    • 2013
  • Recently, the interest on exposure to radiation is rising. The radiation exposure of mammography is higher in absorbed dose than of X-ray, therefore unnecessary exposure needs to be reduced, and higher image quality is needed. Generally, ray quality of the radiation imaging is an important factor that determines image quality and the amount of ray exposure, and they are affected by tube voltage and added filter. The X-ray energy that is exposed from mammography device is generally a continuous spectrum, which includes low energy that has minute influence on the image quality, and high energy that hinders contrast on image. Currently, molybdenum (Mo) and rhodium (Rh) are the most used added filters for mammography device, and they are used differently according to the energy region of X-ray. This study aims to find out the degree of reduction in exposure dose according to the thickness of aluminum (Al), and to study the changes in image quality and dose when the added filter plates that are made with niobium (Nb) or zirconium (Zr) are used, other than molybdenum (Mo) and rhodium (Rh), the two most used added filters that have similar atomic number and K-absorption regions as Nb and Zr. In this study, single-added filters of molybdenum (Mo), niobium (Nb), and zirconium (Zr) are used, and in some cases, Aluminum (Al) is combined with the single filters. In this case, image quality is considered to be improved depending on the type of added filters, and by using Aluminum (Al) filter together with the others, unnecessary X-ray of low energy would be absorbed, therefore the dose is expected to decrease without any influence when the concentration level becomes identical.

Possibility of Combined Meningitis in Under 90-Day-Old Infants With Urinary Tract Infection (생후 90일 미만 영아의 요로 감염에서 세균성 수막염의 동반 가능성)

  • Hwang, Jun Ho;Kim, Su Yeong;Lee, Na Mi;Yi, Dae Yong;Yun, Sin Weon;Chae, Soo Ahn;Lim, In Seok;Park, Ji Young
    • Pediatric Infection and Vaccine
    • /
    • v.29 no.2
    • /
    • pp.84-95
    • /
    • 2022
  • Purpose: Urinary tract infections (UTIs) are the most common serious bacterial infections in young infants. Lumbar puncture (LP) has been used to diagnose coexisting meningitis in infants under 90 days of age with suspected UTI in many hospitals. However, the incidence of bacterial meningitis associated with UTIs is low. We aimed to describe the prevalence of concomitant bacterial meningitis in young infants with UTIs. Methods: The medical records of infants with the first episode of UTI admitted to the Chung-Ang University Hospital from January 2010 to December 2019 were retrospectively reviewed. Infants aged < 90 days who underwent LP with initial evaluation were included. Demographic and clinical features, laboratory findings, and imaging findings were collected and analyzed. Results: Eighty-six infants with UTIs were enrolled in the study. The median age was 61.5 days (interquartile range, 42.3-73.8 days) and boys (90.7%) were predominant. Escherichia coli was the most common pathogen (n=80, 93.0%) and followed by Klebsiella species (n=5, 5.8%). Fifteen (18.1%) specimens produced extended spectrum β-lactamase (ESBL). Five (5.8%) infants had positive blood culture results. Seven (8.1%) infants showed pleocytosis in the cerebrospinal fluid, but none had coexisting bacterial meningitis. Twenty-four (30.8%) infants showed renal dilatation or hydronephrosis on ultrasonography. Dimercaptosuccinic acid (DMSA) scans revealed cortical defects in 17 (21.3%) infants while voiding cystourethrography revealed vesicoureteral reflux in 6 (46.2%) infants. Conclusion: Co-existing bacterial meningitis was not observed in young infants with UTIs. LP could not be routinely performed considering the clinical condition of <90 days old UTI patients.

Development and Performance Test of Preamplifier and Amplifier for Gamma Probe (감마프로브용 전단증폭기와 주증폭기의 개발과 성능 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Lee, Jong-Doo;Kwon, Soo-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.100-109
    • /
    • 1999
  • Purpose: Preamplifier and amplifier are very important parts for developing a portable counting or imaging gamma probe. They can be used for analyzing pulses containing energy and position information for the emitted radiations. The commercial Nuclear Instrument Modules (NIMs) can be used for processing these pulses. However, it may be improper to use NIMs in developing a portable gamma probe, because of its size and high price. The purpose of this study was to develop both preamplifier and amplifier and measure their performance characteristics. Materials and Methods: The preamplifier and amplifier were designed as a charge sensitive device and a capacitor resistor-resistor capacitor (CR-RC) electronic circuit, respectively, and they were mounted on a print circuit board (PCB). We acquired and analyzed energy spectra for Tc-99m and Cs-137 using both PCB and NIMs. Multichannel analyzer (Accuspec/A, Canberra Industries Inc., Meriden Connecticut, U.S.A) and scintillation detectors (EP-047(Bicron Saint-Gobain/Norton Industrial EP-047 (Ceramics Co., Ohio, U.S.A) with $2"{\times}2"$ NaI(T1) crystal and R1535 (Hamamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) with $1"{\times}1"$ NaI(T1) crystal were used for acquiring the energy spectra. Results: Using PCB, energy resolutions of EP-047 detectors for Tc-99m and Cs-137 were 12.92% and 5.01%, respectively, whereas R1535 showed 13.75% and 5.19% of energy resolution. Using the NIM devices, energy resolutions of EP-047 detector for Tc-99m and Cs-137 were measured as 14.6% and 7.58%, respectively. However, reliable energy spectrum of R1535 detector could not be acquired, since its photomultiplier tube (PMT) requires a specific type of preamplifier. Conclusion: We developed a special preamplifier and amplifier suitable for a small sized gamma probe that showed good energy resolutions independent of PMT types. The results indicate that the PCB can be used in developing both counting and imaging gamma probe.

  • PDF

Molecular Genetic Analysis in Dystroglycanopathy with the Fukuyama Congenital Muscular Dystrophy Phenotype (Fukuyama 선천성 근이영양증에서의 분자유전학적 분석)

  • Cha, Lily Myung-Jin;Shin, Jae Eun;Kim, Se Hoon;Lee, Min Jung;Lee, Chul Ho;Lee, Young-Mock
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.17 no.2
    • /
    • pp.48-54
    • /
    • 2017
  • Purpose: Fukuyama congenital muscular dystrophy (FCMD) is a rare, autosomal-recessive disorder characterized by early-onset hypotonia associated with brain malformations in dystroglycanopathy. Although the wide spectrum of congenital muscular dystrophies causes difficulty in diagnosis, correlating the genotype with the clinical phenotype can help diagnose FCMD. Here, we evaluated the correlation of targeted molecular genetic analysis of FKTN gene mutation with the FCMD phenotype. Methods: This study was conducted retrospectively with 9 subjects. Inclusion criteria included clinical symptoms characterized by early-onset hypotonia with magnetic resonance imaging (MRI) featuring brain malformations. FKTN gene-alteration analysis was performed using various FKTN gene-analysis methods, including sequencing. Results: Among the 9 subjects studied, 4 (44.4%) were male and 5 (55.6%) were female. The median age of onset of the first symptom was 3.1 months. The first symptom was a delayed milestone in 6 cases (66.7%). All 9 subjects (100%) presented with early-onset hypotonia and global delayed development. All subjects presented with cortical malformation in their brain MRIs. Of the 9 subjects, 6 subjects had previously undergone muscle biopsy and 4 cases (4/6; 66.7%) showed dystrophic or myopathic features. Pathogenic mutations causing FCMD were identified in 3 cases. Conclusions: In this study, all 3 subjects with FKTN mutations showed important MRI findings (pachygyria and cerebellar dysplasia). These data suggest that patients with characteristic phenotypes who show pachygyria and cerebellar abnormalities in brain MRIs may have a high probability of being diagnosed with FCMD.

  • PDF

MR Spectoscopic Patterns Early and Late Cerebral Ischemic Infarct: Correlation with Clinical Findings (초기 및 지연기 허혈성 뇌경색의 양자 자기공명분광양상 : 임상소견과의 비교)

  • 이종석;장기현;송인찬;고영환;강동화;한문희;노재규
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.146-153
    • /
    • 1999
  • Purpose : To evaluate the proton MR spectroscopy (MRS) findings of early and late ischemic infarcts and to compare these MRS findings with clinical symptoms. Materials and Methods : We obtained MRs spectra of 28 consecutive patients with early ischemic infarct (15 me, 13 women) between 2-10 (mean 6.2) days after stroke onset. Follow-up MRS was carried out between 20-32 (mean 25) days in 12 patients. The MRs spectra were acquired at 1.5T MR unit using single voxel technique with PRESS sequence, TR of 2000ms, TE of 288 (144)ms, and voxel size of 2cm x 2cm x 2cm in the three areas; an infarct lesion, the brain parenchyma adjacent to the lesion, and contralateral normal brain parenchyma. The NAA/creatine, choline/creatine, and lactate/creatine ratios were calculated in each spectrum. The spectra of MRS were compared with clinical symptoms. Results : In early infarct, decreased NAA/creatine ratio (n=22) and increased lactate/creatine ratio (n=25) were found in the infarct lesion. Choline/creastine ratio was within normal range (n=25). On follow-up MRS in late stage, NAA/creatine ratio in the infarct lesion decreased further (n=5), did not change (n=6), or increased (n=1). Lactate/creatine ratio became less elevated (n=10), or did not changed (n=2). Choline/creatine ratio had a trend for increase. The decreased NAA/creatine and increased lactate/creatine ratios were correlated well with the severity of symptoms, respectively. Conclusion : Decreased NAA/creatine and increased lactate/creatine ratios were common MRS findings characteristic in early ischemic infarct and correlated well with clinical severity. On follow-up MRS in late stage, NAA/creatine ratio decreased further or did not change, and lactate/creatine ratio became less elevated.

  • PDF

Determination of Appropriate Sampling Frequency and Time of Multiple Blood Sampling Dual Exponential Method with $^{99m}Tc$-DTPA for Calculating GFR (사구체여과율 계산을 위한 $^{99m}Tc$-DTPA를 이용한 다중 채혈 이중지수법의 적정 채혈 횟수 및 시간의 선정)

  • Kim, Chung-Ho;O, Joo-Hyun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.33-39
    • /
    • 2006
  • Purpose: To determine appropriate sampling frequency and time of multiple blood sampling dual exponential method with $^{99m}Tc$-DTPA for calculating glomerular filtration rate (GFR). Materials & Methods: Thirty four patients were included in this study. Three mCi of $^{99m}Tc$-DTPA was intravenously injected and blood sampling at 9 different times, 5ml each, were done. Using the radioactivity of serum, measured by gamma counter, the GFR was calculated using dual exponential method and corrected with the body surface area. Using spontaneously chosen 2 data points of serum radioactivity, 15 collections of 2-sample GFR were calculated. And 10 collections of 3-sample GFR and 12 collections of 4-sample GFR were also calculated. Using the 9-sample GFR as a reference value, degree of agreement was analyzed with Kendall's $\tau$ correlation coefficients, mean difference and standard deviation. Results: Although some of the 2-sample GFR showed high correlation coefficient, over or underestimation had evolved as the renal function change. The 10-120-240 min 3-sample GFR showed a high correlation coefficient (${\tau}=0.93$), minimal difference ($Mean{\pm}SD=-1.784{\pm}3.972$), and no over or underestimation as the renal function changed. The 4-sample GFR showed no better accuracy than the 3-sample GFR. Conclusions: In the wide spectrum of renal function, the 10-120-240 min 3-sample GFC could be the best choice for estimating the patients' renal function.

Determination of Electron Spin Relaxation Time of the Gadolinium-Chealted MRI Contrast Agents by Using an X-band EPR Technique (EPR을 통한 상자성 자기공명 조영제의 전자스핀 이완시간의 결정)

  • Sung-wook Hong;Yongmin Chang;Moon-jung Hwang;Il-su Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • Purpose: To determine the electronic spin relaxation times, $T_{le}$, of three commercially available Gd-chelated MR contrast agents, Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA, using Electron Paramagnetic Resonance(EPR) technique. Material and Methods: The paramagnetic MR contrast agents, Gd-DTFA(Magnevist) , Gd-DTFA-BMA(OMNISCAN) and Gd-DOTA(Dotarem), were used for this study, The EPR spectra of these contrast agents, which were prepared 2:1 methanol/water solution, were obtained at low temperatures, from $-160^{\circ}C~20^{\circ}C$. The glassy-state EPR spectra for these contrast agents were then fitted by the simulation spectra generated with different zero-field splitting (ZFS) parameters by a computer simulation program 'GEN', which generates the EPR powder spectrum using a given ZFS in $3{\times}3$ tensor. Finally, the spin relaxation times of the contrast agents were then determined from the $T_{2e}$, D, and E values of the best simulation spectra using the McLachlan's theory of average relaxation rate. Results: The electronic transverse spin relaxation times, $T_{2e}'s$, of Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA were 0.113ns, 0.147ns and 1.81ns respectively. The g-values were 1.9737, 1.9735 and 1.9830 and the electronic spin relaxation times, $T_{1e}'s$, were 18.70ns, 33.40ns and $1.66{\mu}s$, respectively. Conclusion: The results of these studies reconfirm that the paramagnetic MR contrast agents with larger ZFS parameters should have shorter $T_{1e}'s$. Among three contrast agents used for this study, Gd-DOTA chelated with cyclic ligand structure shows better electronic property then the others with linear structure. Thus, it is concluded that the exact determination of ZFS parameters is the important factor in evaluating relaxation enhancement effect of the agents and in developing new contrast agents.

  • PDF

Evaluation of Image Quality & Absorbed Dose using MCNPX Simulation in the Digital Radiography System (디지털방사선영상시스템에서 MCNPX 시뮬레이션을 이용한 영상 품질 및 선량평가)

  • An, Hyeon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.327-335
    • /
    • 2016
  • The study is enforce to study image quality evaluation of condition provide the IEC and combination of clinical conditions each quality of radiation that image quality to assess the conditions provided to IEC in the clinical environment to conduct image quality assessment of the digital radiography system in the detector have environmental limits. First, image quality evaluation was evaluated by measuring the MTF, NPS using four quality of radiation and Using MCNPX simulation lastly DQE make a image quality evaluation after calculating the particle fluence to analyze spectrum quality of radiation. Second, Using MCNPX simulation of four quality of radiation was evaluated absorbed dose rate about electronic 1 per unit air, water, muscle, bone by using Radiation flux density and energy, mass-energy absorption coefficient of matter. Results of evaluation of image quality, MTF of four quality of radiation was satisfied diagnosis frequency domain 1.0 ~ 3.0 lp/mm of general X-ray that indicated 1.13 ~ 2.91 lp/mm spatial frequency. The NPS has added filter, spatial frequency 0.5 lp/mm at standard NPS showed a tendency to decrease after increase. Unused added filter, spatial frequency 0.5 lp/mm at standard NPS showed a certain NPS result value after decrease. DQE in 70 kVp / unuesd added filter(21 mm Al) / SID 150 cm that patial frequency 1.5 lp/mm at standard showed a tendency to decrease after certain value showed. Patial frequency in the rest quality of radiation was showed a tendency to decrease after increase. Results of evaluation of absorbed dose, air < water < muscle < bone in the order showed a tendency to increase. Based on the results of this study provide to basic data that present for the image quality evaluation method of a digital radiation imaging system in various the clinical condition.