• Title/Summary/Keyword: spectrum imaging

Search Result 300, Processing Time 0.029 seconds

Optimum Image Compression Rate Maintaining Diagnostic Image Quality of Digital Intraoral Radiographs

  • Song Ju-Seop;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.30 no.4
    • /
    • pp.265-274
    • /
    • 2000
  • Purpose: The aims of the present study are to determine the optimum compression rate in terms of file size reduction and diagnostic quality of the images after compression and evaluate the transmission speed of original or each compressed image. Materials and Methods: The material consisted of 24 extracted human premolars and molars. The occlusal surfaces and proximal surfaces of the teeth had a clinical disease spectrum that ranged from sound to varying degrees of fissure discoloration and cavitation. The images from Digora system were exported in TIFF and the images from conventional intraoral film were scanned and digitalized in TIFF by Nikon SF-200 scanner (Nikon, Japan). And six compression factors were chosen and applied on the basis of the results from a pilot study. The total number of images to be assessed were 336. Three radiologists assessed the occlusal and proximal surfaces of the teeth with 5-rank scale. Finally diagnosed as either sound or carious lesion by one expert oral pathologist. And sensitivity, specificity and k value for diagnostic agreement was calculated. Also the area (Az) values under the ROC curve were calculated and paired t-test and oneway ANOVA test was performed. Thereafter, transmission time of the image files of the each compression level was compared with that of the original image files. Results: No significant difference was found between original and the corresponding images up to 7% (1 : 14) compression ratio for both the occlusal and proximal caries (p<0.05). JPEG3 (1 : 14) image files are transmitted fast more than 10 times, maintained diagnostic information in image, compared with original image files. Conclusion: 1 : 14 compressed image file may be used instead of the original image and reduce storage needs and transmission time.

  • PDF

A novel ceramic GEM used for neutron detection

  • Zhou, Jianrong;Zhou, Xiaojuan;Zhou, Jianjin;Jiang, Xingfen;Yang, Jianqing;Zhu, Lin;Yang, Wenqin;Yang, Tao;Xu, Hong;Xia, Yuanguang;Yang, Gui-an;Xie, Yuguang;Huang, Chaoqiang;Hu, Bitao;Sun, Zhijia;Chen, Yuanbo
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1277-1281
    • /
    • 2020
  • A novel ceramic Gas Electron Multiplier (GEM) has been developed to meet the demand of high counting rate for the neutron detection which is an alternative to 3He-based detector at China Spallation Neutron Source (CSNS). An experiment was performed to measure the neutron transmittance of ceramic-GEM and FR4-GEM at the small angle neutron scattering (SANS) instrument. The result showed the ceramic-GEM has higher transmittance and less self-scattering especially for cold neutrons. One single ceramic GEM could give a gain of 102-104 in the mixture gas of Ar and CO2 (90%:10%) and its energy resolution was about 27.7% by using 55Fe X ray of 5.9 keV. A prototype has been developed in order to investigate the performances of the ceramic GEM-based neutron detector. Several neutron beam tests, including detection efficiency, spatial resolution, two-dimensional imaging, and wavelength spectrum, were carried out at CSNS and China Mianyang Research Reactor (CMRR). The results show that the ceramic GEM-based neutron detector is a good candidate to measure the high intensity neutrons.

Vegetative Mitral Valvular Regurgitation Caused by Infective Endocarditis in a Maltese Dog (말티스견의 감염성 심내막염에 의한 우상성 이첨판 역류증)

  • Choi, Ran;Nam, So-Jeong;Moon, Hyeong-Sun;Lee, Seung-Gon;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.25 no.2
    • /
    • pp.106-111
    • /
    • 2008
  • A 3-year-old intact female Maltese dog (2.5 kg of body weight) with the primary complaint of sudden onset of heart murmur, depression and anorexia was referred to the Veterinary Teaching Hospital of Kangwon National University. The dog was febrile with marked leukocytosis and left apical VI/VI holosystolic murmurs. The electrocardiogram implied the left ventricular enlargement. Diagnostic imaging studies revealed left atrial and ventricular dilation, severe vegetations on mitral valvular cusps with concurrent mitral regurgitation. Based on findings from clinical and diagnostic investigation, the case was diagnosed as vegetative mitral valvular regurgitation caused by infective endocarditis. The dog was successfully treated with broad spectrum antibiotics, diuretics, angiotensin converting enzyme inhibitor and antithrombotics.

DiGeorge syndrome who developed lymphoproliferative mediastinal mass

  • Kim, Kyu Yeun;Hur, Ji Ae;Kim, Ki Hwan;Cha, Yoon Jin;Lee, Mi Jung;Kim, Dong Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.3
    • /
    • pp.108-111
    • /
    • 2015
  • DiGeorge syndrome is an immunodeficient disease associated with abnormal development of 3rd and 4th pharyngeal pouches. As a hemizygous deletion of chromosome 22q11.2 occurs, various clinical phenotypes are shown with a broad spectrum. Conotruncal cardiac anomalies, hypoplastic thymus, and hypocalcemia are the classic triad of DiGeorge syndrome. As this syndrome is characterized by hypoplastic or aplastic thymus, there are missing thymic shadow on their plain chest x-ray. Immunodeficient patients are traditionally known to be at an increased risk for malignancy, especially lymphoma. We experienced a 7-year-old DiGeorge syndrome patient with mediastinal mass shadow on her plain chest x-ray. She visited Severance Children's Hospital hospital with recurrent pneumonia, and throughout her repeated chest x-ray, there was a mass like shadow on anterior mediastinal area. We did full evaluation including chest computed tomography, chest ultrasonography, and chest magnetic resonance imaging. To rule out malignancy, video assisted thoracoscopic surgery was done. Final diagnosis of the mass which was thought to be malignancy, was lymphoproliferative lesion.

Clinical and Radiological Findings of Discogenic Low Back Pain Confirmed by Automated Pressure Controlled Discography

  • Kim, Hyung-Gon;Shin, Dong-Ah;Kim, Hyoung-Ihl;Yoo, Eun-Ae;Shin, Dong-Gyu;Lee, Jung-Ok
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.333-339
    • /
    • 2009
  • Objective : Few studies on the clinical spectrum of automated pressure-controlled discography (APCD)-defined positive discs have been reported to date. Thus, the present study was undertaken to analyze clinical parameters critical for diagnosis of discogenic pain and to correlate imaging findings with intradiscal pressures and pain responses in patients with APCD-positive discs. Methods : Twenty-three patients who showed APCD-positive discs were selected for analysis. CT discogram findings and the degrees of nuclear degeneration seen on MRI were analyzed in comparison to changes of intradiscal pressure that provoked pain responses; and clinical pain patterns and dynamic factors were evaluated in relation to pain provocation. Results : Low back pain (LBP), usually centralized, with diffuse leg pain was the most frequently reported pattern of pain in these patients. Overall, LBP was most commonly induced by sitting posture, however, standing was highly correlated with L5/S1 disc lesions (p<0.01). MRI abnormalities were statistically correlated with grading of CT discogram results (p<005); with most pain response observed in CT discogram Grades 3 and 4. Pain-provoking pressure was not statistically correlated with MRI grading. However, it was higher in Grade 3 than Grade 4. Conclusion : APCD-positive discs were demonstrated in patients reporting centralized low back pain with diffuse leg pain, aggravated by sitting and standing. MRI was helpful to assess the degree of nuclear degeneration, yet it could not guarantee exact localization of the painful discs. APCD was considered to be more useful than conventional discography for diagnosis of discogenic pain.

MR spectroscopy using single-shot RF localization technique (단일 RF 펄스를 사용한 3차원 체적 선택 방법을 이용한 MR 스펙트로 스코피)

  • Rim, C.Y.;Chun, K.W.;Ra, J.B.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.51-54
    • /
    • 1989
  • In last several years, a number of volume localization techniques, such as ISIS, VSE, SPARS and STEAM etc., have been developed for the MR spectroscopy. These localizing techniques, however, require application of several RF pulses for the 3-D volume selection and suffer from T1 and T2 decays due to relatively long RF excitation time. In this paper, we propose a single-shot RF pulse localization technique to achieve the localized 3-D volume selection. This technique combines the cylindrical volume selection technique with a radial gradient coil with single-shot RF pulse and the oscillating selection gradient technique, so thai it minimizes the volume selection time. We report some experimental results obtained with the proposed method which appears promising for 3-D volume imaging and localized spectroscopy.

  • PDF

Prestack Reverse Time Migration for Seismic Reflection data in Block 5, Jeju Basin (제주분지 제 5광구 탄성파자료의 중합전 역시간 구조보정)

  • Ko, Chin-Surk;Jang, Seong-Hyung
    • Economic and Environmental Geology
    • /
    • v.43 no.4
    • /
    • pp.349-358
    • /
    • 2010
  • For imaging complex subsurface structures such as salt dome, faults, thrust belt, and folds, seismic prestack reverse-time migration in depth domain is widely used, which is performed by the cross-correlation of shot-domain wavefield extrapolation with receiver-domain wavefield extrapolation. We apply the prestack reverse-time migration, which had been developed at KIGAM, to the seismic field data set of Block 5 in Jeju basin of Korea continental shelf in order to improve subsurface syncline stratigraphy image of the deep structures under the shot point 8km at the surface. We performed basic data processing for improving S/N ratio in the shot gathers, and constructed a velocity model from stack velocity which was calculated by the iterative velocity spectrum. The syncline structure of the stack image appears as disconnected interfaces due to the diffractions, but the result of the prestack migration shows that the syncline image is improved as seismic energy is concentrated on the geological interfaces.

Development of medium resolution cross-dispersed silicon grisms in the Near Infrared ; Direct Silicon wafer bonding technique

  • Jeong, Hyeon-Ju;Wang, Wei-Song;Gully-Santiago, Michael;Deen, Casey;Pak, Soo-Jong;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.125.2-125.2
    • /
    • 2011
  • We are developing medium resolution cross-dispersed silicon grisms in the near IR region ($1.45{\sim}5.2{\mu}m$). The grisms will be installed in MIMIR, a multifunction instrument at the Lowel Observatory, USA. The two devices are designed to cover H and K band and L and M band simultaneously. Our goal is to make grism with R=3000 at 1.2 arcsec slit. The Silicon has high refractive index (n=3.4 at $1.5{\mu}m$) which enhances the resolving power by up to 5 times when compared to conventional material such as BK-7 (n=1.5 at 1.5 ${\mu}m$). The bonded grisms will be installed in a filter wheel for the uses switch from spectroscopic mode to imaging mode easily. Our device is compact and light weighted while it provides a decent resolving power. We produce monolithic grisms using e-beam lithography at the NASA JPL and chemically etching the grooves on the silicon prisms. Moreover, the main-disperser and cross-disperser will be contacted together by direct Si-Si bonding technique and eventually turn into one piece. The bonded pair offers more stability in terms of the layout of the spectrum and removes the Fresnel loss at the intersection of two grisms. We report on the proper wafer bonding steps through this research, and inspected the bonding quality thermally, optically and mechanically.

  • PDF

Radio and Hard X-ray Study of the 2011 August 09 Flare

  • Hwangbo, Jung-Eun;Bong, Su-Chan;Lee, Jeongwoo;Lee, Dae-Young;Park, Seong-Hong;Park, Young-Deuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.65.1-65.1
    • /
    • 2013
  • The 2011 August 09 Flare is one of the largest X-ray flares of Sunspot Cycle 24 to attract a lot of attention for its various activities detected in coronal images. In this study we concern ourselves mostly on information of high energy electrons produced during this flare provided by hard X ray data from the Reuven Ramaty High-Energy Solar Spectroscopic Imager (RHESSI) and radio data from the Korean Solar Radio Burst Locator (KSRBL) and Ondrejov. EUV images obtained by the Atmospheric Imaging Assembly (AIA) on board the Solar Dynamic Observatory are used to provide the context of magnetic reconnection. In our results, (1) HXR spectra have a rich spectral morphology. Initially it could be fit by one thermal component (T~30MK) and one single power law nonthermal spectrum, but later a better fit could be made by introducing an additional thermal component (T~55 MK). (2) Time delays between the KSRBL burst and the RHESSI hard X-ray emission were found which are more obvious at low frequencies and insignificant at high frequencies. (3) The HXR source lies in the core of the quadrupolar active region. In our interpretation based on AIA 94 A images, the outer part of the active region erupted to be blown out, leaving the intense hard X-ray emission concentrated in the core. We relate the appearance of the second thermal component to the evolution of the AIA 171 and 94 A images. The time delays of microwave peaks to HXR peaks are interpreted as indicating presence of trapped electrons in larger closed magnetic loops. With these result we conclude that the hard X ray and microwaves are due to impulsive acceleration in the low and high heights and a sigmoidal reconnection scenario.

  • PDF

Detection for demineralization of dental hard tissues using index-sequenced radiographs (방사선사진의 인덱스-순서 분석을 통한 치아경조직의 탈염화 검출)

  • Park, Dong-Hyun;Park, Young-Ho;Kim, Kyung-Sook;Park, Jeong-Hoon;Lee, Gi-Ja;Choi, Sam-Jin;Choi, Yong-Suk;Hwang, Eui-Hwan;Park, Hun-Kuk
    • Imaging Science in Dentistry
    • /
    • v.39 no.2
    • /
    • pp.61-68
    • /
    • 2009
  • Purpose : The purpose of this study was to develop the radiographic technique for detecting the demineralization which is known as indication of dental caries. Materials and Methods: This technique was based on the comparing of multiple radiographs which was irradiated by multiple X-ray spectra. For the meaningful comparing, the multiple radiographs were reconstructed to the dosimetrically consistent images using a standard material. The difference of resulting images of same target with multiple spectra represents the difference of response of material as regards the spectra. Results : We have found about 10% of demineralization of dental hard tissues particularly in the proximal region through the analyzing of differences. Conclusion: Most intriguing thing in this investigation was that the method to analyze difference shows us to an anatomic structure of dental hard tissues even if absolute values of optical density were excluded during the procedures. (Korean J Oral Maxillofac Radiol2009; 39: 61-8)

  • PDF