• Title/Summary/Keyword: spectroscopic analysis

Search Result 891, Processing Time 0.025 seconds

Spectroscopic Evidence of the Autoxidation Products Derived from Methyl Linolenate (Methyl Linolenate의 산화생성물(酸化生成物)에 대(對)한 분광학적(分光學的) 연구(硏究))

  • Ahn, Jong-Kyoon;Cho, Mi-Za;Kim, In-Sook;Oh, Sung-Ki
    • Applied Biological Chemistry
    • /
    • v.32 no.1
    • /
    • pp.1-7
    • /
    • 1989
  • The autoxidation products derived from methyl linolenate are isolated and characterized by using thin-layer chromatography, infrared, ultraviolet and nuclear magnetic resonance spectrometries. In addition, the propriety of the application of NMR spectrometry to the analysis of the autoxidation products is examined. Spectroscopic data indicate that the autoxidation of methyl linolenate produces hydroperoxides and trans, cis-substituted diene. The autoxidation products have a predominant cis, trans-conjugated diene system with some trans, trans-configuration. The spectroscopic data of ir, uv, and nmr are very consistent with each other, and further investigation of the multiplet region at $5.83{\sim}6.60ppm$ would be very helpful for the structural elucidation of the autoxidation products.

  • PDF

Determination of optical properties of Pr3+-doped selenide glasses of Ge-Sb-Se system using spectroscopic ellipsometry (분광타원법을 이용한 Pr 첨가 Ge-Sb-Se 계열 셀레나이드 유리의 굴절률 결정)

  • 신상균;김상준;김상열;최용규;박봉제;서홍석
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.6
    • /
    • pp.594-599
    • /
    • 2003
  • By using the spectroscopic ellipsometry, we have measured and analyzed the optical characteristics of P $r^3$$^{+}$-doped selenide glasses of Ge-Sb-Se system, a strong candidate material for U band fiber amplifiers. The ellipsometric spectra measured in the transparent wavelengths range of the material were all fitted to a model consisting of ambient/roughness/thin fil $m_strate structures to obtain simultaneously the optical properties such as refractive index, in terms of Sellmeier parameters and film structure of P $r^3$$^{+}$-doped selenide glasses. Repeated measurements on different positions in both polished faces rendered to verify positional dependence of measured spectre-ellipsometric data. Hence, the model made possible the analysis of the optical characteristics of the glasses. Even though surface roughness was mainly responsible for the position dependencies, the averaged refractive indexes were as precise as to reflect the minute compositional change tantamount to 1 mol%. The measured refractive indexes are useful for design of core and clad compositions of single-mode selenide optical fibers.

ESTIMATION OF NITROGEN-TO-IRON ABUNDANCE RATIOS FROM LOW-RESOLUTION SPECTRA

  • Kim, Changmin;Lee, Young Sun;Beers, Timothy C.;Masseron, Thomas
    • Journal of The Korean Astronomical Society
    • /
    • v.55 no.2
    • /
    • pp.23-36
    • /
    • 2022
  • We present a method to determine nitrogen abundance ratios with respect to iron ([N/Fe]) from molecular CN-band features observed in low-resolution (R ~ 2000) stellar spectra obtained by the Sloan Digital Sky Survey (SDSS) and the Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST). Various tests are carried out to check the systematic and random errors of our technique, and the impact of signal-to-noise (S/N) ratios of stellar spectra on the determined [N/Fe]. We find that the uncertainty of our derived [N/Fe] is less than 0.3 dex for S/N ratios larger than 10 in the ranges Teff = [4000, 6000] K, log g = [0.0, 3.5], [Fe/H] = [-3.0, 0.0], [C/Fe] = [-1.0, +4.5], and [N/Fe] = [-1.0, +4.5], the parameter space that we are interested in to identify N-enhanced stars in the Galactic halo. A star-by-star comparison with a sample of stars with [N/Fe] estimates available from the Apache Point Observatory Galactic Evolution Experiment (APOGEE) also suggests a similar level of uncertainty in our measured [N/Fe], after removing its systematic error. Based on these results, we conclude that our method is able to reproduce [N/Fe] from low-resolution spectroscopic data, with an uncertainty sufficiently small to discover N-rich stars that presumably originated from disrupted Galactic globular clusters.

Optical Spectroscopic Analysis Techniques to Detect Elemental Profile of Human Teeth Dentine

  • Saifullah Jamali;Muhammad Aslam Khoso;Irfan Ali Sanjrani;Hussain Saleem;Tariq Ali Siyal;Muhammad Ashraf;Mansoor Ahmed Memon;Ghulam Murtaza;Zahid Hussain Arain;Zaheer Ahmed Ujjan;Muhammad Niaz Laghari;Samina Saleem;Nek M. Shaikh;Waseem A. Bhutto;Abdul Majid Soomro;Altaf H. Nizamani
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.3
    • /
    • pp.193-202
    • /
    • 2023
  • Numerous articles under the study and the examination of heavy metals in human teeth have been published in recent years. The heavy metal poisoning is a widespread issue emerged in toxicology area these days. It has been discovered that long-term exposure to heavy metals typically present in traces, in our everyday meals, drinking water, and in the environment as pollution causes heavy metal poisoning in human beings. Industrial effluents, Coal and Oil, as well as a variety of consumer items, such as cosmetics, can all cause this type of exposure. Teeth, which are often thought of as exoskeleton parts, store heavy metals with a high affinity and represent long-term exposure information. In this study, we have chosen and examined the sections of dentine instead, then examined the entire tooth. We have combined the work done on the examination of heavy metals in human teeth using several instrumental approaches e.g. "Optical Spectroscopic Techniques" to detect elemental profile of human teeth in the current study.

Validation of acid-base titration equivalence between spectroscopic titrator (SPT) and conventional titrators (분광학적 적정기(SPT)와 기존 적정기의 산-염기 적정 동등성 검증)

  • Shin, Jiwon;Kim, Yeajin;Lee, Hyoseong;Shin, Jisun;Yoo, Hyein;Chae, Won-Seok
    • Analytical Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.267-274
    • /
    • 2021
  • Acid-base titration experiments were carried out using the same sample to obtain a direct comparison of analysis results between a new titrator and conventional Spectrator (SPT) titrators. This allowed the confirmation of an endpoint both by spectroscopic detection and by conventional titrators (automatic burette (ABT) and autotitrator (ATT)). Statistical analysis was performed on the measured values (endpoints) obtained using different titrators, to assess their differences by comparison of straightness, equivalence, ANOVA, F-test, and t-test results. The coefficients of determination, confirmed by straightness, were all >0.999. Thus, the null hypothesis that there was no statistical difference could not be rejected. The Bland-Altman analysis method was used to confirm agreement with the new experimental method. No discrepancy was found in the measured values obtained using different titrators used in this study.

Near Infrared Diffuse Reflectance Spectroscopy to Measure Pulmonary Edema

  • Larry Leonardi;David H.Burns;Luis Openheimer;Rene P.Michel
    • Near Infrared Analysis
    • /
    • v.2 no.1
    • /
    • pp.43-53
    • /
    • 2001
  • A non-invasive spectroscopic method is presented for the measurement of pulmonary edema. Both early diagnosis and quantitative edema estimates were investigated. The spectroscopic determination of pulmonary edema involved the acquisition of diffuse reflectance spectra in the near-infrared (NIR) region with change in water concentration - water is the main constituent of edema fluid. Pulmonary edema was induced into the excised perfused lungs of seven animals by elevating the hydrostatic pressure. Estimates of edema were ascertained from a partial least squares regression of the measured spectral response. Actual edema was determined from the change (increase) in total lung weight. Estimates in relative lung weight increases due to in vitro edema were made with the near infrared spectra. The results revealed that fluid accumulation produced spectral changes in the O-H and C-H absorptions as well as scattering changes in the spectra. Histology of the lung was used to verify the presence or absence of interstitial and alveolar edema. Results demonstrated that near infrared spectroscopy might provide a new tool for clinical assessment of pulmonary edema.

Spectroscopic Studies on the Mechanism of Interaction of Vitamin $B_{12}$ with Bovine Serum Albumin

  • Kamat, B.P.;Seetharamappa, J.
    • Journal of Photoscience
    • /
    • v.11 no.1
    • /
    • pp.29-33
    • /
    • 2004
  • The mechanism of interaction of cyanocobalamin (CB) with bovine serum albumin (BSA) has been investigated by spectrofluorometric and circular dichroism methods. Association constant for the CB-BSA system showed that the interaction is non-covalent in nature. Binding studies in the presence of an hydrophobic probe, 8-anilino-l-naphthalene sulphonic acid, sodium salt (ANS) showed that there is hydrophobic interaction between CB and ANS and they do not share common sites in BSA. Stern-Volmer analysis of fluorescence quenching data showed that the fraction of fluorophore (protein) accessible to the quencher (CB) was close to unity indicating thereby that both tryptophan residues of BSA are involved in drug-protein interaction. The rate constant for quenching, greater than $10^{10}$ $M^{-1}$ $s^{-1}$, indicated that the drug binding site is in close proximity to tryptophan residue of BSA. Thermodynamic parameters obtained from data at different temperatures showed that the binding of CB to BSA involves hydrophobic bonds predominantly. Significant increase in concentration of free drug was observed for CB in presence of paracetamol. Circular dichroism studies revealed the change in helicity of BSA due to binding of CB to BSA.

  • PDF

Mid-IR Luminosity Functions of Local Galaxies in the North Ecliptic Pole Field

  • Kim, Seong Jin;Lee, Hyung Mok;Jeong, Woong-Seob
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.72.3-72.3
    • /
    • 2015
  • We present the mid-infrared (MIR) luminosity function (LF) of local (z < 0.3) star forming (SF) galaxies based on the AKARI's NEP-Wide Survey data. We utilized a combination of the NEP-Wide point source catalogue containing a large number (114,000) of infrared (IR) sources distributed over the wide (5.4 sq. deg) field and spectroscopic redshift (z) data for 1790 selected targets obtained by optical follow-up surveys with MMT/Hectospec and WIYN/Hydra. The AKARI's continuous $2{\sim}24{\mu}m$ wavelength coverage and the spectroscopic redshifts for sample galaxies enable us to derive accurate spectral energy distributions (SEDs) in the mid-infrared. We carried out SED-fit analysis and employed 1/Vmax method to derive the mid-IR (e.g., $8{\mu}m$, $12{\mu}m$, and $15{\mu}m$ rest-frame) luminosity functions. Our results for local galaxies from the NEP region generally consistent with various previous works for other fields over wide luminosity ranges. The comparison with the results of the NEP-Deep data implies the luminosity evolution from higher redshifts towards the present epoch. We attempted to fit our derived LFs to the double power-laws and present the resulting power indices. We also examined the correlation between mid-IR luminosity and total IR luminosity.

  • PDF

Partial least squares regression theory and application in spectroscopic diagnosis of total hemoglobin in whole blood (부분최소제곱회귀(Partial Least Squares Regression) 이론과 분광학적 혈중 헤모글로빈 진단에의 응용)

  • 김선우;김연주;김종원;윤길원
    • The Korean Journal of Applied Statistics
    • /
    • v.10 no.2
    • /
    • pp.227-239
    • /
    • 1997
  • PLSR is a powerful multivariate statistical tool that has been successfully applied to the quantitative analyses of data in spectroscopy, chemistry, and industrial process control. Data in spectorscopy is represented by spectrum matrix measured in many wavelengths. Problems of many kinds of noise in data and itercorrelation between wavelengths are quite common in such data. PLSR utilizes whole data set measured in many wavelengths to the analysis, and handles such problems through data compression method. We investigated the PLSR theory, and applied this method to the data for spectroscopic diagnosis of Total Hemoglobin in whole blood.

  • PDF

AN EXTENSION OF A RELIABLE WAVELENGTH COVERAGE OF THE AKARI NG GRISM MODE

  • Baba, Shunsuke;Nakagawa, Takao;Isobe, Naoki;Shirahata, Mai;Ohyama, Youichi;Yano, Kenichi;Kochi, Chihiro
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.45-47
    • /
    • 2017
  • The Infrared Camera onboard the AKARI satellite carried out spectroscopic observations with a grism mode named NG, whose wavelength coverage was $2.5-5.0{\mu}m$. We reinvestigate the current flux calibration for the NG grism mode, with which calculated flux density implausibly decreases at $4.9{\mu}m$ especially for red objects due to the second-order light contamination. We perform a new spectral response calibration using blue and red standard objects simultaneously. New response curves which contain both the first-and second-order light are able to separate each contribution consistently and useful for studies of red objects such as CO ro-vibrational absorption in active galactic nuclei.