• 제목/요약/키워드: spectroradiometer

검색결과 278건 처리시간 0.025초

Spatial Downscaling of MODIS Land Surface Temperature: Recent Research Trends, Challenges, and Future Directions

  • Yoo, Cheolhee;Im, Jungho;Park, Sumin;Cho, Dongjin
    • 대한원격탐사학회지
    • /
    • 제36권4호
    • /
    • pp.609-626
    • /
    • 2020
  • Satellite-based land surface temperature (LST) has been used as one of the major parameters in various climate and environmental models. Especially, Moderate Resolution Imaging Spectroradiometer (MODIS) LST is the most widely used satellite-based LST product due to its spatiotemporal coverage (1 km spatial and sub-daily temporal resolutions) and longevity (> 20 years). However, there is an increasing demand for LST products with finer spatial resolution (e.g., 10-250 m) over regions such as urban areas. Therefore, various methods have been proposed to produce high-resolution MODIS-like LST less than 250 m (e.g., 100 m). The purpose of this review is to provide a comprehensive overview of recent research trends and challenges for the downscaling of MODIS LST. Based on the recent literature survey for the past decade, the downscaling techniques classified into three groups-kernel-driven, fusion-based, and the combination of kernel-driven and fusion-based methods-were reviewed with their pros and cons. Then, five open issues and challenges were discussed: uncertainty in LST retrievals, low thermal contrast, the nonlinearity of LST temporal change, cloud contamination, and model generalization. Future research directions of LST downscaling were finally provided.

Terra MODIS 위성영상과의 비교를 통한 COMS GOCI 위성영상의 식생지수 적용성 평가 (Applicability of Vegetation Indices from Terra MODIS and COMS GOCI Imageries)

  • 박진기;김봉섭;오시영;박종화
    • 한국농공학회논문집
    • /
    • 제55권6호
    • /
    • pp.47-55
    • /
    • 2013
  • The objective of this study is to evaluate the applicability of Communication, Ocean, and Meteorological Satellite (COMS) Geostationary Ocean Color Imager (GOCI) vegetation indices on a quantitative analysis. For evaluation, the vegetation indices such as RVI, NDVI and SAVI were extracted by using COMS GOCI and Terra Moderate Resolution Imaging Spectroradiometer (MODIS) imageries. The 4,000 points using simple random sampling (SRS) method were randomly extracted from land areas except ocean to compare the vegetation indices from two images. The results of linear regression showed that the regression coefficients of RVI, NDVI, and SAVI between COMS GOCI and Terra MODIS were 0.66~0.82, 0.71~0.83, and 0.71~0.83, respectively. Especially, the regression coefficients of RVI (r=0.85), NDVI (r=0.91) and SAVI (r=0.91) were strongly related from September 2011 to January 2012. Thus, COMS GOCI can be substituted for particular periods and it needs to verify additionally.

위성영상과 데이터 마이닝 기법을 이용한 토양수분 산정 (Estimate Soil Moisutre Using Satelite Image and Data Mining)

  • 김광섭;박한균;조소현
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.1615-1619
    • /
    • 2010
  • 토양수분은 토양입자에 포함되어 있는 물을 의미하는 것으로 지표면과 대기간의 에너지 균형과 물 순환을 조절하는데 중요한 요소이다. 본 연구에서는 토양수분 산정을 위하여 2003년 1월부터 2008년 12월까지의 MODIS(Moderate Resolution Imaging Spectroradiometer) 위성관측 자료로부터 획득한 정규식생지수(NDVI: Normalized Difference Vegetation Index)자료와 지표면 온도자료, 우리나라 76개소 기상관측소 중에 자료의 보유기간이 30년 이하인 관측소와 섬 지역들을 제외한 57개 지점의 강수량, 토양온도 자료 및 우리나라 전역에 대한 토지피복, 유효토심자료를 이용하여 데이터 마이닝(Data Mining) 기법의 하나인 CART(Classification And Regression Tree) 기법을 이용하여 토양수분을 산정하였다. 먼저 신뢰성 높은 토양수분 관측 자료를 가진 용담댐 유역의 6개 지점에 대하여 토양수분을 산정하여 적용 가능성을 분석하였다. 3개 지점의 토양수분 관측치는 토양수분 산정 모형 수립에 사용하였으며 검증에 사용된 1개 지점의 토양수분의 관측치와 추정치 간의 상관계수를 확인한 결과 전체적인 토양수분의 거동을 잘 나타내고 있어 토양수분 추정 모형의 적용가능성을 확인하였다. 이를 이용하여 용담댐 유역의 토양수분 분포와 우리나라 전역에 대한 토양수분 분포도를 추정하였다. 신뢰할 수 있는 지상관측 토양수분 관측치가 다양한 지상조건에 대하여 존재하지 않는 한계가 있음에도 불구하고 제시된 토양수분산정 방법은 제한된 가용자료를 사용한 우리나라 전역의 토양수분 산정에 있어 합리적인 접근법이라 판단된다.

  • PDF

MODIS NDVI를 이용한 북한의 벼 수량 추정 연구 (A Study on Estimating Rice Yield of North Korea using MODIS NDVI)

  • 홍석영;최은영;김건엽;강신규;김이현;장용선
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2009년도 춘계학술대회 논문집
    • /
    • pp.116-120
    • /
    • 2009
  • 원격탐사 기술은 사람이 직접 방문하여 조사하기 힘든 극지라든가 농업환경에 대한 자료 요구도가 높으면서도 직접 수집이 어려운 비접근 지역에 대한 정보를 추출하는데 유용한 관측수단이다. 본 연구는 MODIS(Moderate Resolution Imaging Spectroradiometer) 제공 산출물 중 16일 단위로 작성되는 NDVI(Normalized Difference Vegetation Index, MOD13)를 이용하여 북한의 벼 수량을 추정하는 것을 목적으로 하였고, 그 가능성과 한계에 대하여 알아보았다. 2000년부터 2008년까지 촬영된 MODIS MOD13 자료를 미국 NASA로부터 제공받아 좌표체계를 우리나라에 맞게 투영하고 NDVI를 추출하여 자료분석에 사용하였다. 통계청에서 발표한 벼 수량 및 생산량 통계자료를 이용하였다. 농촌진흥청 국립농업과학원에서 작성한 북한의 토지피복분류도를 이용하여 서해안 평야지대에 위치한 논을 위도별로 네군데 정하여 관심지역(area of interest)으로 설정하였다. 이 관심지역에 대한 시계열 값을 추출하여 연중 연간 변화를 분석하고 2000년부터 2007년까지 수잉기의 NDVI 값을 이용하여 수량에 대한 상관계수(r)는 $0.77^*$로 5%에서 유의하여 NDVI 값에 따라 벼 수량에 큰 영향을 주는 것으로 나타났다. 수잉기의 NDVI 값과 벼 수량에 대해 회귀분석한 결과($R^2=0.591^*$), NDVI에 따른 벼 수량의 변이를 59.1% 설명할 수 있었다. 이와 같이 회귀식을 이용하여 2008년 북한의 벼 수량은 약 2.80 ton/ha로 추정되었다.

  • PDF

인공 위성과 기상 모형을 이용한 증발산 추정 (Estimation of Evapotranspiration using Satellite data and Meteorological Model)

  • 장근창;강신규;김재철;김준
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2009년도 춘계학술대회 논문집
    • /
    • pp.213-218
    • /
    • 2009
  • 에너지 전달 과정과 밀접한 관계가 있는 증발산(Evapotranspiration)은 기후 변화나 육상 생태계 생산성에서 매우 중요한 요소이며, 수문학적 순환과 지역적 물 관리 측면에서 매우 중요하다. 최근 인공위성을 이용하여 증발산을 추정하기 위한 노력이 많이 진행되고 있으며, 특히 MODIS (Moderate Resolution Imaging Spectroradiometer)는 증발산을 추정하기 위한 좋은 정보를 제공하고 있다 하지만, 구름 등에 의한 증발산 입력 자료 결측은 전체 자료의 획득률을 낮추고, 연속적인 증발산 모니터 링을 제한한다. 따라서 본 연구에서는 MODIS 기반의 증발산 입력 자료의 개선하여 서로 다른 식생과 지형 구조를 갖는 플럭스 연구지에 대한 증발산의 추정 및 평가하고, 남한에 대한 MODIS 기반의 증발산 지도 작성하였다. 또한 구름에 의해 결측된 날에 대해서는 MODIS-MM5 4차원 자료동화 기법을 이용한 증발산의 연속적인 모니터링 기법을 개발하였다. MODIS 기반의 증발산을 추정하기 위해 Revised RS-PM 알고리즘을 사용하였다. 증발산을 평가하기 위해 4 곳의 플럭스 연구지(광릉, 해남 이상 대한민국, 타카야마, 토마코아미 이상 일본) 자료와 비교하였고, 매우 신뢰성 있는 결과를 얻을 수 있었다. MODIS 입력 자료의 개선으로 획득률은 2배 가량 증가하였다. 남한에 대한 연간 증발산은 평균적으로 약 35%의 획득률 (365일 중 약 120일)과 함께 산출되었고, 시 공간적인 분포를 잘 나타내었다. 구름 낀 날에 대한 MODIS-MM5 자료 동화 기법의 적용은 증발산의 연속적인 모니터링을 가능하게 하였다.

  • PDF

Bluetooth 무선 통신 기능을 이용한 LED 조명시스템 설계 (Design of LED Lighting System using Bluetooth Wireless Communcation)

  • 김혜명;양우석;조영식;박대희
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.1-7
    • /
    • 2015
  • The Light Emitting Diode(LED) lighting control system proposed in this thesis is made up of a sensor module, a microcontroller, Bluetooth wireless communication, LED Driver, and LED downlight. The sensor module, comprised of an infrared sensor, an illumination sensor, and a temperature sensor, was designed to one Printed Circuit board(PCB). The system is able to identify the environment information collected by the sensor, and make it possible to control lighting automatically and manually through sensors. In addition, depending on users' conditions, a color temperature can be controlled. CS-1000, a spectroradiometer, was employed to measure the changing values of a color temperature in 8 steps. According to a test, it was found that it was possible to change a color temperature from 3187K of Warm White LED to 5598K of Cool White LED. The Bluetooth based wireless communication technique makes it possible to control more lighting devices than other wireless communication techniques does.

Detection of Foliar Nutrients of Oil Palm Crop Using Remote Sensing

  • Ibrahim, Ab.Latif;Hashim, Mazlan;Rasib, Abd.Wahid;Ali, Mohamad Idris;Kadir, Wan Hazli Wan;Sumairi, Mohd Razif;Haron, Khalid
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.558-560
    • /
    • 2003
  • This paper examines the capability of remote sensing technique for detecting and quantifying the foliar nutrients of oil palm crop. Study has been carried out in the Malaysian Palm Oil Board (MPOB) Research Station in Kluang Johore, Malaysia. Result of the study shows a strong relationship between measured foliar nutrient and the spectral reflectance measured using spectroradiometer. Model that has been developed can be used to estimate the nutrient concentration in the oil palm plantation at micro level and also at macro -level using appropriate satellite data.

  • PDF

Improvement of Temporal Resolution for Land Surface Monitoring by the Geostationary Ocean Color Imager Data

  • Lee, Hwa-Seon;Lee, Kyu-Sung
    • 대한원격탐사학회지
    • /
    • 제32권1호
    • /
    • pp.25-38
    • /
    • 2016
  • With the increasing need for high temporal resolution satellite imagery for monitoring land surfaces, this study evaluated the temporal resolution of the NDVI composites from Geostationary Ocean Color Imager (GOCI) data. The GOCI is the first geostationary satellite sensor designed to provide continuous images over a $2,500{\times}2,500km^2$ area of the northeast Asian region with relatively high spatial resolution of 500 m. We used total 2,944 hourly images of the GOCI level 1B radiance data obtained during the one-year period from April 2011 to March 2012. A daily NDVI composite was produced by maximum value compositing of eight hourly images captured during day-time. Further NDVI composites were created with different compositing periods ranging from two to five days. The cloud coverage of each composite was estimated by the cloud detection method developed in study and then compared with the Moderate Resolution Imaging Spectroradiometer (MODIS) Aqua cloud product and 16-day NDVI composite. The GOCI NDVI composites showed much higher temporal resolution with less cloud coverage than the MODIS NDVI products. The average of cloud coverage for the five-day GOCI composites during the one year was only 2.5%, which is a significant improvement compared to the 8.9%~19.3% cloud coverage in the MODIS 16-day NDVI composites.

RS/GIS를 이용한 하천 침수 지역 정보화 기법 연구 (A Study of River Flood Area Informationization Technique Using RS and GIS)

  • 신형진;채효석;황의호;박재영
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2012년도 학술발표회
    • /
    • pp.256-256
    • /
    • 2012
  • 2011년 태국 차오프라야 강 유역($160,813km^2$)에서 발생한 홍수에 의해 많은 피해가 발생했다. 태국 홍수는 2011년 7월 말부터 3개월간 내린 집중호우로 중부지방에 50년 만에 최악의 자연재해를 맞이하였다. 태국 북쪽 지역에서 난 강과 핑 강의 범람을 시작으로 태국 중앙 지역을 흐르는 차오프라야 강의 수위는 상류의 홍수가 하류로 내려옴에 따라 범람하여 수도 방콕까지 침수되었다. 본 연구에서는 홍수범람시 시공간적 침수상황이 파악 가능한 Terra MODIS (Moderate Resolution Imaging Spectroradiometer) 영상을 이용하여 태국 차오프라야 강 유역의 홍수에 의한 침수지역을 추정하고자 하였다. 2011년 7월 29일에서 2012년 1월 9일까지의 500 m 해상도인 MODIS product MOD09 (Surface Reflectance) 8일 합성 영상을 수집하고 식생지수 (EVI; Enhanced Vegetation Index), 지표수분지수 (LSWI; Land Surface Water Index))와 DVEL지수 (Difference Value between EVI and LSWI)를 이용하여 홍수범람 지역과 수역관련지역을 정보화 기법을 제시하였다. 본 연구의 결과는 홍수 범람지역의 자료를 정보화하고 그 결과를 정량적으로 제시하는 방법으로 활용될 수 있으며, MODIS 자료의 이용은 시공간적 하천 홍수범람지역 탐지의 가능성을 알 수 있었다.

  • PDF

원격탐사 기반 기준 증발산 산정 모의: 낙동강 유역조사 분석 (Estimation of Reference Evapotranspiration Based on Remote Sensing: Nakdong River Hydrologic Survey)

  • 서찬양;이종진;박재영;최민하
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2012년도 학술발표회
    • /
    • pp.67-70
    • /
    • 2012
  • 현재 국내외에서는 양질의 증발산을 관측하여 활용하기 위해 증발접시 (evaporation pan), 침루계 (lysimeter) 등을 이용하여 실측하거나 Flux Tower에서 Eddy covariance technique, Bowen ratio method 등을 이용하여 경험적으로 산정하고 있다. 이러한 방법으로 산정되는 증발산은 크게 두 분류로 나눌 수 있다. 일반적인 기후 상태에서 유역의 토양이 증발산에 방해를 받지 않을 정도로 충분히 물을 포함하고 있고, 식생이 조밀한 상태에서의 증발산량을 의미하는 잠재 증발산과 실제 산정치인 실제 증발산으로 나눌 수 있다 (Thornthwait, 1939). 본 연구에서는 유역의 잠재 증발산을 산정하여 실제 증발산과 비교를 통해 적용성을 확인하고자 한다. 잠재 증발산을 산정하는 방법은 Moderate Resolution Imaging Spectroradiometer (MODIS) 인공위성 데이터를 이용한 원격탐사 기술을 적용하여 산정한다. 원격탐사 기술은 지상 관측의 단점을 보완한 것으로써, 날씨, 인간 활동 등 주변 외부 환경의 영향에 민감하게 반응하여 공간적인 분포 현황을 파악하는 것이 어려운 지상 관측의 한계점을 대체하기 위한 방법이다. 이들 방법으로는 가장 널리 쓰이는 Penman-Monteith (Penman, 1948; Monteith, 1965), 일별 최대, 최저, 평균 기온을 이용한 Hargreaves 방법 (Hargreaves, 1985)과 Priestley-Taylor 방법 (Priestley and Taylor, 1972) 등의 세 가지 방법을 소개하였다. 세 가지 방법으로 산정된 잠재 증발산을 통해 해당 유역의 잠재 증발산의 공간적인 거동을 파악해 볼 수 있다.

  • PDF