• Title/Summary/Keyword: spectrophotometer

Search Result 1,501, Processing Time 0.044 seconds

Catalytic Wet Oxidation of Azo Dye Reactive Black 5 (아조염료 Reactive Black 5 폐수의 촉매습식산화)

  • Suh, Il-Soon;Yoo, Shin-Suk;Ko, Mi-So;Jeong, Samuel;Jung, Cheol-Goo;Hong, Jeong-Ah;Yoon, Wang-Lai
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.259-267
    • /
    • 2010
  • The catalytic wet oxidations of the wastewater containing azo dye Reactive Black 5(RB5) with heterogeneous catalyst of CuO have been carried out to investigate the effects of temperature($190{\sim}230^{\circ}C$) and catalyst concentration(0.00~0.20 g/l) on the removals of colour and total organic carbon TOC. The wastewater colour was measured with spectrophotometer, and the oxidation rate was estimated with TOC. About 90% of colour was removed during 120 min in thermal degradation of the RB5 wastewater at $230^{\circ}C$, while TOC was not removed at all. As increasing reaction temperature and catalyst concentration, the removal rates of colour and TOC increased in the catalytic wet oxidations of RB5 wastewater. The effects of catalyst were already considerable even at 0.01 g CuO/l, while the removal rates of colour and TOC increased negligibly with increasing the catalyst concentration above 0.05 g CuO/l. The initial destruction rates of the wastewater colour have shown the first-order kinetics with respect to the wastewater colour. TOC changes during catalytic wet oxidations have been well described with the global model, in which the easily degradable TOC was distinguished from non-degradable TOC of the wastewater. The impacts of reaction temperature on the destruction rate of the wastewater colour and TOC could be described with Arrhenius relationship. Activation energies of the colour removal reaction in thermal degradation, wet oxidation, and catalytic wet oxidation(0.20 g CuO/l) of the RB5 wastewater were 108.4, 78.3 and 74.1 kJ/mol, respectively. The selectivity of wastewater TOC into the non-degradable intermediates relative to the end products in the catalytic wet oxidations of RB5 wastewater was higher compared to that in phenol wet oxidations.

Effects of the color components of light-cured composite resin before and after polymerization on degree of conversion and flexural strength (광중합형 복합레진의 중합 전, 후의 색 성분이 중합률과 굴곡강도에 미치는 영향)

  • Yoo, Ji-A;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.324-335
    • /
    • 2011
  • Objectives: This study investigated the effects of the color components of light-cured composite resin before and after polymerization on degree of conversion (DC) and biaxial flexural strength (FS). Materials and Methods: Four enamel shades (A1, A2, A3, A4) and two dentin shades (A2O, A3O) of Premisa (Kerr Co.) and Denfil (Vericom Co.) were evaluated on their CIE $L^*,\;a^*,\;b^*$ color components using the spectrophotometer before curing, after curing and at 7 day. The DC of same specimens were measured with Near-infrared spectrometer (Nexus, Thermo Nicolet Co.) at 2 hr after cure and at 7 day. Finally, the FS was obtained after all the other measurements were completed at 7 day. The correlations between each color component and DC and FS were evaluated. Results: The light-curing of composite resin resulted in color changes of Premisa in red-blue direction and Denfil in green-blue direction. The DC and FS were affected by product, time and shade (3-way ANOVA, p < 0.05) and product and shade (2-way ANOVA, p < 0.05), respectively. Premisa only showed a significant correlation between the DC and CIE $a^*$ component - before and after polymerization (Pearson product moment correlation, p < 0.05). The FS of Premisa showed significant negative correlations with CIE $a^*$ and CIE $b^*$ components. Conclusions: The DC and FS of the light-curing composite resin were affected by the color components of the material before and after polymerization.

EVALUATING THE RELIABILITY AND REPEATABILITY OF THE DIGITAL COLOR ANALYSIS SYSTEM FOR DENTISTRY (치과용 디지털 색상 분석용 기기의 정확성과 재현 능력에 대한 평가)

  • Jeong, Joong-Jae;Park, Su-Jung;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.352-368
    • /
    • 2008
  • This study was done to evaluate the reliability of the digital color analysis system (ShadeScan, CYNOVAD, Montreal. Canada) for dentistry. Sixteen tooth models were made by injecting the A2 shade chemical cured resin for temporary crown into the impression acquired from 16 adults. Surfaces of the model teeth were polished with resin polishing cloth. The window of the ShadeScan handpiece was placed on the labial surface of tooth and tooth images were captured, and each tooth shade was analyzed with the ShadeScan software. Captured images were selected in groups, and compared one another. Two models were selected to evaluate repeatability of ShadeScan, and shade analysis was performed 10 times for each tooth. And, to ascertain the color difference of same shade code analyzed by ShadeScan, CIE $L^*a^*b^*$values of shade guide of Gradia Direct (GC, Tokyo, Japan) were measured on the white and black background using the Spectrolino (GretagMacbeth, USA), and Shade map of each shade guide was captured using the ShadeScan. There were no teeth that were analyzed as A2 shade and unique shade. And shade mapping analyses of the same tooth revealed similar shade and distribution except incisal third. Color difference (${\Delta}E^*$) among the Shade map which analyzed as same shade by ShadeScan were above 3. Within the limits of this study, digital color analysis instrument for dentistry has relatively high repeatability, but has controversial in accuracy.

Hair Heavy Metal Contents in Mentally Retarded Children III - In Association with Mercury - (정신지체아 두발 중 중금속 함량 III - 수은과의 관련성 -)

  • Han, Ki-Hwan;Jang, Bong-Ki;Park, Soon-Woo;Kim, Doo-Hie
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.3 s.27
    • /
    • pp.368-379
    • /
    • 1989
  • The relationship between mercury level of hair and mental retardation was investigated. The 297 subjects with mental retardation were drawn from two schools providing special educational services, one, consisted of children living in an orphan home, another, children with parents. The 117 centre] subjects were drawn from whom had got average or above average academic achivement in a regular elementary school. Hair sample were taken from the nape of the neck and the mercury analysis was carried out on an atomic absorption spectrophotometer(IL 551). There was no relationship between mercury contents and age, and there was a statistically significant difference in mercury contents between male and female in the mentally retarded children living with parents. Children in the retarded group had significantly higher mercury contents compared with control group except the female group with parents. Also, the mercury levels in the retarded group living in an orphan home were significantly higher than that of the retarded group with parents. The concomitant diseases were Down's syndrome, epilepsy, cerebral palsy and autism. There were statistically significant differences in hair mercury levels in the cases of accompanying Down's syndrome and cerebral palsy in male and Down's syndrome and autism in female compared with the control group of the same sex. The most accompanying handicap was speech disturbance(40.7%) and the others were crippled, emotional disturbance etc. The percentages of double handicap were 66.7% among 6 persons exceeding 6ppm of their hair mercury contents. 10.4% among $3{\sim}6$ ppm and 15.7% among the group of 3ppm or less. The findings of this study suggest that the more opportunities of exposure to mercury in mentally retarded children may have occurred, so it can not be excluded the possibility of mercury as a contributing factor to mental retardation. Therefore, the causal relationship between mercury levels and mental retardation should be established through the examinations about their living environments, dietary pattern, eating habit etc.

  • PDF

In Vivo Preperation of Standard Reference Materials of Lead in Blood (생체내 혈중 납 표준물질의 제조)

  • Chung, Kyou-Chull;Choi, Ho-Chun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.863-873
    • /
    • 1995
  • This report describes a preperation and characterization of canine blood lead(Pb) standard reference material(SRM). Three adult beagle dogs(A, B, and C)were orally dosed with gelatin capsules containing $Pb(NO_3)_2$, equivalent to $10\sim80mg$ Pb/kg body weight. Blood was drawn 24 hours after the dose from the cephalic vein into lead free 500ml Pyrex beaker in which EDTA.K was contained as an anticoagulant. The amount of lead given to individual dog was varied arbitrarily. Three month later, 3 canine animals were orally dosed with lead secondarily to make mixed SRM(D1) which was mixed different concentrations of lead in bloods with A1, B1, and C1 in vitro. The SRMs for A, B, C, A1, B1, C1, and D1 were distributed 2ml each into more than 300 lead free bottles, and were stored in refregerator at $4^{\circ}C$. The amount of lead in canine whole blood samples were determined using a Varian 30A atomic absorption spectrophotometer(AAS) with a model GTA-96 graphite tube atomizer with D2 background correction and a Hitachi Z-8100 AAS with Zeeman background correction. The sensitivity and detection limits for lead determination of Varian 30A were $0.46{\mu}g/L,\;0.34{\mu}g/L,\;and\;0.56{\mu}g/L,\;0.14{\mu}g/L$ of Hitachi Z-8100, respectively. Day to day variations in determination of blood lead concentration in a certain sample were $31.11{\pm}1.36{\mu}g/100ml$ by Varian 30A, and $33.08{\pm}0.82{\mu}g/100ml$ by Hitachi Z-8100, showing the difference of 3% between the two results. At the blood lead concentrations of $56.31{\pm}1.98{\mu}g/100ml(A),\;40.89{\pm}0.80{\mu}g/100ml(B),\;59.01{\pm}1.38{\mu}g/100ml(C)$, the precisions of replicated measurements by AAS were 3.52%, 1.96%, and 2.34%, respectively. Coefficient variation(CV) of SRMs(A, B, and C) within a standard sample were ranged from 0.92% to 7.50%, and those between 5 standard samples were 1.21%, 2.64%, and 1.11%, respectively, showing inter-vial variation of $1{\mu}g/100ml$. Lead levels in SRMs during one month storage were unchanged. The overall recoveries were $89.6\sim100.4%,\;91.6\sim101.9%,\;90.3\sim100.0%$ for A, B, and C SRMs, means were $56.46{\pm}2.69{\mu}g/100ml,\;39.35{\pm}1.89{\mu}g/100ml,\;57.40{\pm}2.31{\mu}g/100ml$, and measurement ranges were$52.88{\pm}59.26{\mu}g/100ml,\;37.47{\pm}41.68{\mu}g/100ml,\;54.80{\pm}60.69{\mu}g/100ml$, respectively. Those results were laid within confidence limits values. The lead concentrations in the mixed sample(D1) stored over one month period were ranged from $32.76{\mu}g/100ml\;to\;33.54{\mu}g/100ml$, with CV ranging from 1.2% to 2.7%. The results were similiar to each of single samples(A1, B1, and C1) in respect of homogeneity and stability. Results of the mixed blood sample analysed after 1 month storage at $4^{\circ}C$ by four other laboratories(L1, L2, L3, L4) were similar with those of our laboratory($L5;31.18{\pm}0.24{\mu}g/100ml$, acceptable range by $CDC;25.18\sim37.18{\mu}g/100ml$), showing the concentrations of $25.91{\pm}1.19{\mu}g/100ml(L1),\;34.16{\pm}0.22{\mu}g/100ml(L2),\;35.68{\pm}0.85{\mu}g/100ml(L3),\;30.95{\pm}0.46{\mu}g/100ml(L4)$ in a each samples.

  • PDF

A Comparative Study of Blood Lead Measurement by Polarized Zeman Effect Correction AAS and D2 Correction AAS Method (편광 Zeeman 보정 및 D2 보정 방법에 의한 혈중연 측정치의 비교 연구)

  • Lee, Seok Ki;Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • Blood lead assay by $D_2$ lamp background correction method of atomic absorption spectrophotometer(AAS) with wavelength of 283.3 nm is most popular in occupational health practice in Korea. On the other hand, $D_2$ lamp background correction method with wavelength of 217.0 nm is also often used in general chemical analysis for lead assay in general purpose. But both methods have some weakness of background correction which brought direct effect on the results of analysis. Recently blood lead assay with polarized Zeeman effect of AAS was introduced and is now preferred in many laboratory than $D_2$ correction method in blood lead analysis. But still AAS with $D_2$ lamp are widely used in the field of occupational health in Korea. This study compared blood lead assay data with $D_2$ correction methods(283.3 and 217.0 nm) and with that of polarized Zeeman effect correction method to evaluate the validity of 02 correction methods. The results obtained were as follows; 1. Taking the value of polarized Zeeman effect method as reference value of 1.00, the mean relative value of $D_2$ correction method with wavelength of 217.0 nm was 0.92 and that with wavelength of 283.3 nm was 0.90 respectively in the analysis of blood lead whose value were below $20.0{\mu}g/dl$(p<0.001). Both mean values were statistically smaller than polarized Zeeman effect correction method. But in the analysis of blood whose value were between 20.0 to $20.0{\mu}g/dl$, the mean relative value of $D_2$ correction method was 0.96 in both wavelength and did not differ from polarized Zeeman effect method(p<0.001). There was no difference of blood lead between $D_2$ correction method and polarized Zeeman effect method in the analysis of blood lead whose value were over $40.0{\mu}g/dl$. 2. The variations of background correction value in polarized Zeeman effect method were not changed by increase of blood lead, but those in $D_2$ correction methods were increased by the increase of blood lead. While then relative standard deviation(RSD) of data measured by Zeeman effect method were decreased by the increase of blood lead, those by $D_2$ methods were nol differed by the increase of blood lead.

  • PDF

Study of the Characteristics of Roasted Coffee Bean in Seoul (서울시 유통 원두커피의 품질 특성)

  • Cho, In-soon;Hong, Mi-sun;Lee, Eun-seon;Kim, Si-jung;Lee, Yong-cheol;Kim, Sung-dan;Jo, Han-bin;Kim, Jung-hun;Jung, Kweon
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.3
    • /
    • pp.236-241
    • /
    • 2015
  • This study was performed to survey and evaluate the contents of pH, total acidity, caffeine, harmful metals (Pb, Cd) and total polyphenol in coffee extraction. In total, coffee bean. Total fifty coffee samples were analysed. A 5 g portion of roasted ground coffee samples were extracted in coffee-maker with 100 mL of distilled water and the extraction were used in all experiments. The pH range was 4.72~5.25 (mean value = 4.99). According to increase of the roasting temperature, the pH were shown a tendency to increase. The contents of total acidity was 0.72~2.25% (mean value = 1.59%). According to increase of the roasting temperature, the contents of total acidity were shown a tendency to decrease. The contents of harmful metals (Pb, Cd) in coffee extractions were determined by ICP. The average contents of Pb and Cd were 0.0112 and 0.0011 mg/kg, respectively. The contents of caffeine in coffee extractions were determined by HPLC, the range of detection was 0.51~20.28 mg/mL (mean value = 12.29 mg/mL). According to increase of the roasting temperature, the contents of caffeine were shown a tendency to increase. The contents of total polyphenol in coffee extractions were determined by spectrophotometer, the range of detection was 18.88~43.90 mg/mL (mean value = 31.94 mg/mL). According to increase of the roasting temperature, the contents of total polypenol were shown a tendency to decrease.

A Study on Migration of Heavy Metals from Kitchen Utensils Including Glassware, Ceramics, Enamel, Earthenware and Plastics (유리제 등 조리기구 중 중금속 이행에 관한 연구)

  • Choi, Jae-Chon;Park, Se-Jong;Goh, Hyeah;Lee, Ju Yeun;Eom, Mi Ok;Kim, Meehye
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.4
    • /
    • pp.334-339
    • /
    • 2014
  • The purpose of our study was to investigate the migration level of lead (Pb), cadmium (Cd), antimony (Sb), arsenic (As), hexavalent chromium ($Cr^{6+}$) and mercury (Hg) from cookwares into food simulants and to evaluate the safety of each heavy metals. The test articles for heavy metals were glassware, ceramics, enamel, earthenware, polypropylene and polyethylene cookwares for Pb and Cd, enamel for Sb, earthenware for As, polyethylene and polypropylene cookwares for $Cr^{6+}$ and Hg. All the article samples of 391 intended for contact with foods were purchased in domestic markets. Pb, Cd, Sb and As were analyzed by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES), $Cr^{6+}$ by UV visible spectrophotometer and Hg by mercury analyzer. The migration levels of heavy metals in all the samples were within the migration limits of Ministry of Food and Drug Safety (MFDS). As a result of safety evaluation, our results showed that the estimated daily intakes (EDI, mg/kg bw/day) were $9.12{\times}10^{-6}$ and $8.83{\times}10^{-7}$ for Pb and Cd from ceramics and $1.19{\times}10^{-5}$, $1.23{\times}10^{-5}$ and $7.52{\times}10^{-6}$ for Pb, Cd and Sb from enamel. Tolerable daily intakes (TDI, mg/kg bw/day) were established respectively as 0.0036, 0.00081, 0.0021, and 0.0006 for Pb, Cd, As and Hg by JECFA (Joint FAO/WHO Expert Committee on Food Additives), as 0.0060 for Sb by WHO (World Health Organization). When comparing with TDIs, the EDIs accounted for 0.25% and 0.11% for Pb and Cd from ceramics and 0.33%, 1.52% and 0.13% for Pb, Cd and Sb from enamel.

Study on Rheological Characterization and Chemical Composition by Cooking Method of Yeongebacksuk (Korean traditional cooked chicken) (조리조건이 연계백숙의 성분과 관능적 품질에 미치는 영향)

  • 장영수;이효지
    • Korean journal of food and cookery science
    • /
    • v.4 no.2
    • /
    • pp.31-38
    • /
    • 1988
  • The chicken cooked by three different methods were put and sensory evaluation, mechanical and chemical composition test. The results were as following : 1. Standard recipe were as followig : \circled1 Kettle cooking was chicken 700 g, waxyrice 100 g, garlic 30 g, water 2000 cc, time 60 min. \circled3 Pressure cooking was chicken 700 g, waxyrice 100 g, garlic 30 g, water 2000 cc, time 30 min. \circled3 Microwave cooking was chicken 700g, waxyrice 100 g, garlic 30 g, water 1000 cc, time 30 min. 2. Sensory evaluation \circled1 There were no typical difference of the color of soupstock with in the three cooking methods. \circled2 The turbidity of soupstock was from Kettle cooking, microwave cooking and pressure cooking in turn. \circled3 There were no typical difference of the viscosity of soupstock with in the three cooking methods. \circled4 The kettle cooking was the best of mouthfeel and taste. \circled5 There were no typical difference of muscle, with in the three cooking methods. 3. Mechanical Test \circled1 The result of the cutting force of muscle which measured by rheomether were the leg muscle was more tough than breast muscle. \circled2 The viscosity of boiled rice was from kettle cooking, pressure cjooking and microwave cooking in turn. \circled3 The result of the turbidity of soupstock which measured by spectrophotmeter was from kettle cooking, pressure cooking and microwave cooking in turn. 4. Proximate chemical composition \circled1 Protein of muscle was 20.30-25.67%, Soupstock was 0.29-0.72% \circled2 Fat of muscle was 27.29-47.15% , Soupstock was 37-68.38%. \circled3 Potasium of muscle was 2.75-3.6 mg, Soupstock was 1.15-6.3 mg. \circled4 Iron of muscle was 1.17-1.39 mg, Soupstock was 0.96 mg.

  • PDF

Studies on the Determination Method of Monascus Pigments in Foods (식품 중 홍국색소의 분석법에 관한 연구)

  • Lee, Tal-Soo;Lee, Young-Ja;Kwon, Yong-Kwan;Park, Jae-Seok;Ko, Hyun-Sook;Sim, Kyu-Chang;Lee, Ju-Yeun;Shin, Jae-Wook;Song, Jee-Won;Lee, Chul-Won
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.641-644
    • /
    • 2001
  • This study was performed for development of new analytical method of monascus pigments in foods. In this method, analysis of monascus pigment in foods has been carried out by detection of monascin and ankaflavin of the main color component of monascus pigment as indicator compounds. Monascin and ankaflavin were isolated and identified by TLC, HPLC, Prep. HPLC, $^{1}H-NMR$ and Mass spectrophotometer. The analysis of monascin and ankaflavin in foods such as massal, sausage, mixed press ham, mixed fish sausage, semi-dried sausage and syrup was performed by using reverse phase high performance liquid chromatograph with Capcell Pak C18 column at wave length 390 nm. The quantitative results of monascin were as follows : $0.01{\sim}3.31\;{\mu}g/g$ item in massal, $0.05{\sim}0.10\;{\mu}g/g$ in mixed fish sausage, and $0.34{\sim}0.35\;{\mu}g/g$ in semi-dried sausage. But the quantitative results of ankaflavin were as follows: $0.02{\sim}0.89\;{\mu}g/g$ in massal, ankaflavin were not founded in other samples.

  • PDF