• 제목/요약/키워드: spectral peak

검색결과 509건 처리시간 0.033초

Compressive sensing-based two-dimensional scattering-center extraction for incomplete RCS data

  • Bae, Ji-Hoon;Kim, Kyung-Tae
    • ETRI Journal
    • /
    • 제42권6호
    • /
    • pp.815-826
    • /
    • 2020
  • We propose a two-dimensional (2D) scattering-center-extraction (SCE) method using sparse recovery based on the compressive-sensing theory, even with data missing from the received radar cross-section (RCS) dataset. First, using the proposed method, we generate a 2D grid via adaptive discretization that has a considerably smaller size than a fully sampled fine grid. Subsequently, the coarse estimation of 2D scattering centers is performed using both the method of iteratively reweighted least square and a general peak-finding algorithm. Finally, the fine estimation of 2D scattering centers is performed using the orthogonal matching pursuit (OMP) procedure from an adaptively sampled Fourier dictionary. The measured RCS data, as well as simulation data using the point-scatterer model, are used to evaluate the 2D SCE accuracy of the proposed method. The results indicate that the proposed method can achieve higher SCE accuracy for an incomplete RCS dataset with missing data than that achieved by the conventional OMP, basis pursuit, smoothed L0, and existing discrete spectral estimation techniques.

Quantitation of relationship and development of nutrient prediction with vibrational molecular structure spectral profiles of feedstocks and co-products from canola bio-oil processing

  • Alessandra M.R.C.B. de Oliveira;Peiqiang Yu
    • Animal Bioscience
    • /
    • 제36권3호
    • /
    • pp.451-460
    • /
    • 2023
  • Objective: This program aimed to reveal the association of feed intrinsic molecular structure with nutrient supply to animals from canola feedstocks and co-products from bio-oil processing. The special objective of this study was to quantify the relationship between molecular spectral feature and nutrient availability and develop nutrient prediction equation with vibrational molecular structure spectral profiles. Methods: The samples of feedstock (canola oil seeds) and co-products (meals and pellets) from different bio-oil processing plants in Canada (CA) and China (CH) were submitted to this molecular spectroscopic technique and their protein and carbohydrate related molecular spectral features were associated with the nutritional results obtained through the conventional methods of analyses for chemical and nutrient profiles, rumen degradable and intestinal digestible parameters. Results: The results showed that the spectral structural carbohydrates spectral peak area (ca. 1,487.8 to 1,190.8 cm-1) was the carbohydrate structure that was most significant when related to various carbohydrate parameters of canola meals (p<0.05, r>0.50). And spectral total carbohydrate area (ca. 1,198.5 to 934.3 cm-1) was most significant when studying the various carbohydrate parameters of canola seeds (p<0.05, r>0.50). The spectral amide structures (ca. 1,721.2 to 1,480.1 cm-1) were related to a few chemical and nutrient profiles, Cornell Net Carbohydrate and Protein System (CNCPS) fractions, truly absorbable nutrient supply based on the Dutch protein system (DVE/OEB), and NRC systems, and intestinal in vitro protein-related parameters in co-products (canola meals). Besides the spectral amide structures, α-helix height (ca. 1,650.8 to 1,643.1 cm-1) and β-sheet height (ca. 1,633.4 to 1,625.7 cm-1), and the ratio between them have shown to be related to many protein-related parameters in feedstock (canola oil seeds). Multi-regression analysis resulted in moderate to high R2 values for some protein related equations for feedstock (canola seeds). Protein related equations for canola meals and carbohydrate related equations for canola meals and seeds resulted in weak R2 and low p values (p<0.05). Conclusion: In conclusion, the attenuated total reflectance Fourier transform infrared spectroscopy vibrational molecular spectroscopy can be a useful resource to predict carbohydrate and protein-relates nutritional aspects of canola seeds and meals.

깊이별 토양 부식산의 분자량분포 및 분광학적 특성 규명 (Molecular Size Distribution and Spectroscopic Characterization of Humic and Fulvic Acids Extracted from Soils in Different Depth)

  • 신현상;이동석;정근호;이창우
    • 분석과학
    • /
    • 제15권4호
    • /
    • pp.373-380
    • /
    • 2002
  • 본 연구는 토양에 침적된 방사능 물질의 거동에 부식산이 미치는 영향을 평가하기 위한 기초연구로서 깊이별 토양에 존재하는 휴믹산과 풀빅산을 추출하여 그 특성을 분석하였다. 휴믹산과 풀빅산의 분자량 분포는 한외여과법을 이용하여 조사하였으며, 분광학적 특성으로는 자외선-가시광선, 적외선 및 형광분광 분석을 실시하였다. 휴믹산의 주요 분자량 분포 영역은 30~100 kDa (46~56%)이었으며, 풀빅산은 10~30 kDa (33~43%) 이었다. 토양 깊이가 증가할수록 휴믹산과 풀빅산 분자의 분자량은 전체적으로 감소하는 경향을 보였다. 자외선-가시광선 분석 결과, 휴믹산이 풀빅산에 비하여 전체적으로 1.4~1.5배 더 높은 흡광계수 (280 nm)를 나타내었고, 휴믹산의 경우 토양 깊이가 증가할수록 흡광계수가 증가하였다. Synchronous 형광 분석 결과, 휴믹산과 풀빅산의 방향족 고리화합물은 428 nm 영역 (type 1)과 498 nm 영역 (type II)에서의 형광피크에 해당하는 두 가지 특성 구조를 가짐을 알 수 있었다. 휴믹산 분자는 대부분 장파장 영역 (type II)에서의 방향족 고리구조 특성을 보였으며, 휴믹산과 풀빅산 모두 토양층의 깊이가 증가할수록 장파장 영역의 방향족 고리 특성이 증가하는 경향을 보였다. 적외선 분석 결과, 풀빅산이 휴믹산에 비해 카르복실기 (${\sim}1720cm^{-1}$)의 피크세기가 높았으며, 토양 깊이가 증가할수록 휴믹산과 풀빅산분자의 카르복실기의 피크세기가 증가하는 특성을 보였다.

하이포이드 기어의 진동 스펙트럼 분석 (Spectral Analysis of Hypoid Gear Vibration)

  • 김영배;이종원
    • 대한기계학회논문집
    • /
    • 제6권4호
    • /
    • pp.346-352
    • /
    • 1982
  • The vibration characteristics of hyoid gears are experimentally investigated with backlash and tooth mesh frequency varied. Experiments are performed with two types of gear sets; well-machined and over-lapped gears. Through the experimental works, a constant torque 0.8kg.m is applied to th gears and a pulse type of trigger signal synchronizing tooth contact is used to measure the tooth mesh frequency and to average the gear vibration signal in the time domain. The time averaged vibration signals are frequency analyzed by a digital signal analyzer. The experimental results show the vibration characteristics of the two different types of gears in relation to backlash amount and mesh frequency variations are well differentiated by harmonic amplitudes and their ratios, and peak-to-peak amplitude of the gear vibration.

AlGaAs 진행파 반도체 레이저 광증폭기의 모드록킹 (Mode Locking of AlGaAs Semicondctor Laser Traveling Wave Amplifiers)

  • 이창희;강승구;정기웅;임시종;유태경
    • 전자공학회논문지A
    • /
    • 제32A권1호
    • /
    • pp.119-128
    • /
    • 1995
  • We report hybrid and passive mode-locking results of tilted-stripe AlGaAs semiconductor laser traveling wave amplifiers with saturable absorbers. Dependence ofthe pulse width on the mode locking frequency, the bandwidth of spectral filters, and the bias current of the laser amplifier are investigated. We generate 4 ps optical pulses by using the hybrid mode locking technique. The repetition rate and the peak power of generated pulses are 516 MHz and 170 mW, respectively. The tuning range of uor mode locked laser is 10 nm with the center wavelength of 780 nm. We also generate 2.6 ps optical pulses with peak power of 830 mW by using the passive mode locking technique.

  • PDF

축류팬 익단누설와류의 비정상 특성 (Unsteady Nature of a Tip Leakage Vortex in an Axial Flow Fan)

  • 장춘만;김광용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.845-850
    • /
    • 2003
  • Unsteady nature of a tip leakage vortex in an axial flow fan operating at a design and off-design operating conditions has been investigated by measuring the velocity fluctuation in a blade passage with a rotating hotwire probe sensor. Two hot-wire probe sensors rotating with the fan rotor were also introduced to obtain the cross-correlation coefficient between the two sensors located in the vortical flow as well as the fluctuating velocity. The results show that the vortical flow structure near the rotor tip can be clearly observed at the quasi-orthogonal planes to a tip leakage vortex. The leakage vortex is enlarged as the flow rate is decreased, thus resulting in the high blockage to main flow. The spectral peaks due to the fluctuating velocity near the rotor tip are mainly observed in the reverse flow region at higher flow rates than the peak pressure operating condition. However, no peak frequency presents near the rotor tip for near stall condition.

  • PDF

In-Vivo 및 In-Vitro 실험을 통한 기계식 판막의 혈전현상 검출을 위한 기초연구 (Basis or In-Vivo and In-Vitro Thrombosis Detection of Mechanical Valve)

  • 이혁수;이상훈;김삼현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.113-117
    • /
    • 1997
  • In this paper we detected the thrombosis formation by spectral analysis and neural network. Using microphone and amplifier, we measured the sound from the mechanical valve which is attached to the pneumatic ventricular assist device. The sound was sampled by A/D converter and the periodogram is the main algorithm or obtaining spectrum. We made the valvular thrombosis models using pellethane and silicon and they are thrombosis model on the disk, around the sewing ring and fibrous tissue growth across the orifice of valve. The spectrum of normal and 5 kinds of thrombotic valve were obtained and primary and secondary peak appeared in each spectrum waveform. So to distinguish the secondary peak of normal and thrombotic valve quantatively, 3 layer back propagation neural network.

  • PDF

원자로음분석에 의한 원내동발생 요 (A Study of Reactor Internal Dynamics by Reactor Noise Analysis)

  • Chun, Hee-Young;Koh, Byoung-Joon;Shin, Kyun-Kook
    • 대한전기학회논문지
    • /
    • 제31권10호
    • /
    • pp.109-115
    • /
    • 1982
  • Reactor dynamics were studied by reactor noise at TRIGA MARK Il reactor whose rated power is 250KW thermal. The power spectral densities(PSD) of the noise were measured by stochastic method with high resolution digital filters and Fast Fourier Transformers. The transfer function of the reactor at zero power was identical to the theoretical characteristics. When the power was increasec above 1KW, reactor showed its poswer resonances at 3Hz and 10 Hz. It was analyzed that 3Hz peak was generated by heat transfer and coolant flow effects and 10Hz peak by nuclear reaction effects.

  • PDF

Performance Analysis for Secured Service Signals of RNSS Systems

  • Han, Kahee;Lee, Subin;Lee, Kihoon;Won, Jong-Hoon
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제11권4호
    • /
    • pp.341-349
    • /
    • 2022
  • When designing a new RNSS signal, the performance analysis for the legacy signal providing the same service, is required to determine the performance requirements. However, there are few studies on the secured service (SS) signal performance analysis, and the waveform is the only published information on the signal design component of the SS signal. Therefore, in this paper, we introduce several figures-of-merit (FoMs) that can be used for performance analysis in terms of the waveform. And then, we calculate the FoMs, such as autocorrelation main peak to secondary peak ratio (AMSR), spectral efficiency, Gabor bandwidth, multipath error, and jamming resistance quality factor, for the existing SS signals and discuss the analysis results. Finally, we conclude that the superior waveform for each FoM is different, and that the consideration of the trade-off relationship between the FoMs is required for waveform design.

$AgGa_{1-x}In_{x}Se_{2}$ 박막의 광학적 특성 (Optical Properties of $AgGa_{1-x}In_{x}Se_{2}$ Thin Films)

  • 김형곤;김화택
    • 대한전자공학회논문지
    • /
    • 제23권5호
    • /
    • pp.706-711
    • /
    • 1986
  • The AgGa1-xInxSe2 films are deposited by a flash evaporation method onto pyrex glass substrates at temperatures between 5\ulcorner and 360\ulcorner. The single crystalline films which have X-ray diffraction peak of only (112) plane are preared at substrate temperature above 360\ulcorner. The prepared AgGa 1-xInxSe2 films are high photosensitive. The temperature coefficients of energy gap are found to be (-1.2~-4.0)x10**4 eV/K and (-3.1~-5.2)x10**-4 eV/K, and that of peak energy of spectral photoresponse curve are found to be (-1.1 ~ -3.0)x10**-4 eV/K(50K~100K) and (-2.4~-5.1)x10**-4 eV/K(100K~300K).

  • PDF