• Title/Summary/Keyword: spectral indices

Search Result 163, Processing Time 0.017 seconds

Age-related Changes of the Finger Photoplethysmogram in Frequency Domain Analysis (연령증가에 따른 지첨용적맥파의 주파수 영역에서의 변화)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.42-62
    • /
    • 2008
  • Objectives: It is well known that some parameters of the photoplethysmogram (PPG) acquired by time domain contour analysis can be used as markers of vascular aging. But the previous studies that have been performed for frequency domain analysis of the PPG to date have provided only restrictive and fragmentary information. The aim of the present investigation was to determine whether the harmonics extracted from the PPG using a fast Fourier transformation could be used as an index of vascular aging. Methods: The PPG was measured in 600 recruited subjects for 30 second durations, To grasp the gross age-related change of the PPG waveform, we grouped subjects according to gender and age and averaged the PPG signal of one pulse cycle. To calculate the conventional indices of vascular aging, we selected the 5-6 cycles of pulse that the baseline was relatively stable and then acquired the coordinates of the inflection points. For the frequency domain analysis we performed a power spectral analysis on the PPG signals for 30 seconds using a fast Fourier transformation and dissociated the harmonic components from the PPG signals. Results: A final number of 390 subjects (174 males and 216 females) were included in the statistical analysis. The normalized power of the harmonics decreased with age and on a logarithmic scale reduction of the normalized power in the third (r=-0.492, P<0.0001), fourth (r=-0.621, P<0.0001) and fifth harmonic (r=-0.487, P<0.0001) was prominent. From a multiple linear regression analysis, Stiffness index, reflection index and corrected up-stroke time influenced the normalized power of the harmonics on a logarithmic scale. Conclusions: The normalized harmonic power decreased with age in healthy subjects and may be less error prone due to the essential attributes of frequency domain analysis. Therefore, we expect that the normalized harmonic power density can be useful as a vascular aging marker.

  • PDF

Alterations of Heart Rate Variability upon β3-Adrenergic Receptor Polymorphism and Combined Capsaicin, Sesamin, and L-Carnitine in Humans (복합 캡사이신, 세사인, 그리고 카르니틴과 베타3 유전자 다형에 대한 심박수 변이성의 영향)

  • Shin, Ki-Ok;Kim, Hyun-Jun;Kang, Sung-Hwun
    • Journal of Life Science
    • /
    • v.18 no.3
    • /
    • pp.291-297
    • /
    • 2008
  • We investigated whether 1) the combined capsaicin (75 mg), sesamin (30 mg), and L-carnitine (900 mg) (CCSC) ingestion enhances autonomic nervous system (ANS) activities including thermogenic sympathetic activity as energy metabolic modulator, 2) ${\beta}_3-AR$ polymorphism of each subject influences with ANS activity. Seven healthy males $(22.0{\pm}0.5\;yr)$ volunteered for this study. The cardiac autonomic nervous activities evaluated by means of heart rate variability of power spectral analysis were continuously measured during 5 min every 30 min for total 120 min resting condition with CCSC or placebo oral administration chosen at random. The results indicated that, there are not $Arp/Arg^{64}$ variants of the ${\beta}_3-AR$ genotypes in our subjects. There were not also significant differences in heart rate during rest between both trials. The difference of ANS activity did not reach the statistical significance between both trials. However, the significant improvement showed TOTAL power, HF component, and the indices of SNS and PNS activities before and at 30 min after CCSC ingestion (p<0.05, respectively). In conclusions, although each component of combined CCSC is associated with lipolysis and/or fat oxidation, the combined CCSC consumption is not influenced in stimulation of thermogenic sympathetic activity as modulator of energy metabolism. In rather, our results suggested that CCSC ingestion improves the balance of both SNS and PNS activities. Therefore, it will be considered many combined nutrient components for ergogenic and/or lipolysis effects as well as genetic variants affecting ANS activity in further studies.

Evaluation of Effective Sensing Distance and Measurement Efficiency for Ground-Based Remote Sensors with Different Leaf Distribution in Tobacco Plant (연초의 엽위 분포형태에 따른 지상 원격센서의 유효 탐사거리와 측정 효율성 평가)

  • Jeong, Hyun-Cheol;Hong, Soon-Dal
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.2
    • /
    • pp.126-136
    • /
    • 2008
  • Tobacco plants grown in pots by sand culture for 70 days after transplanting were used to evaluate the sensing distance and measurement efficiency of ground-based remote sensors. The leaf distribution of tobacco plant and sensing distance from the sensors to the target leaves were controlled by two removal methods of leaves, top-down and bottom-up removal. In the case of top-down removal, the canopy reflectance was measured by the sensor located at a fixed position having an optimum distance from the detector to the uppermost leaf of tobacco every time that the higher leaves were one at a time. The measurement of bottom-up removal, a the other hand, was conducted in the same manner as that of the top-down removal except that the lower leaves were removed one by one. Canopy reflectance measurements were made with hand held spectral sensors including the active sensors such as $GreenSeeker^{TM}$ red and green, $Crop\;Circle\;ACS-210^{TM}$ red and amber, the passive sensors of $Crop\:Circle^{TM}$, and spectroradiometer $SD2000^{TM}$. The reflectance indices by all sensors were generally affected by the upper canopy condition rather than lower canopy condition of tobacco regardless of sensor type, passive or active. The reflectance measurement by $GreenSeeker^{TM}$ was affected sensitively at measurement distance longer than 120 cm, the upper limit of effective sensing distance, beyond which measurement errors are appreciable. In case of the passive sensors that has no upper limit of effective distance and $Crop\;Circle^{TM}(ACS210)$ that has the upper limit of effective sensing distance specified with 213 cm, longer than that of estimated distance, the measurement efficiency affected by the sensing distance showed no difference. This result suggests that it is necessary to use the sensor specified optimum distance. The result revealed that active sensors are more superior than their passive counterparts in establishing between the relative ratio of reflectance index and the dry weight of tobacco treated by top-down removal, and in the evaluation of biomass. $The\;Crop\;Circle\;ACS-210^{TM}$ red was proved to have the highest efficiency of measurement, followed by $Crop\;Circle^{TM}(ACS210)$ amber and $GreenSeeker^{TM}$ red, $Crop\;Circle^{TM}$ passive, $GreenSeeker^{TM}$ green, and spectroradiometer, in descending order.