• Title/Summary/Keyword: spectral

Search Result 8,261, Processing Time 0.033 seconds

Synthesis and Characterization of Thermally Cross-linkable Hole Transporting Material Based on Poly(p-phenylenevinylene) Derivative (열경화가 가능한 poly(p-phenylenevinylene)계 정공전달 물질의 합성 및 특성)

  • Choi, Jiyoung;Lee, Bong;Kim, Joo Hyun
    • Applied Chemistry for Engineering
    • /
    • v.19 no.3
    • /
    • pp.299-303
    • /
    • 2008
  • A thermally cross-linkable polymer, poly[(2,5-dimethoxy-1,4-phenylenevinylene)-alt-(1,4-phenylenevinylene)] (Cross-PPV), was synthesized by the Heck coupling reaction. In order for the polymer to be cross-linkable, 20 mol% excess divinylbenzene was added. The chemical structure of Cross-PPV and thermally crosslinked Cross-PPV were confirmed by FT-IR spectroscopy. From the FT-IR, UV-Vis, and PL spectral data, thermally crosslinked Cross-PPV was insoluble in common organic solvents. The HOMO and LUMO energy level of thermally cross-linked Cross-PPV were estimated -5.11 and -2.56 eV, respectively, which were determined by the cyclic voltammetry and UV-Vis spectroscopy. From the energy level data, one can easily notice that thermally crosslinked Cross-PPV can be used for hole injection layer effectively. Bilayer structured device (ITO/crosslinked Cross-PPV/PM-PPV/Al) was fabricated using poly(1,4-phenylenevinylene-(4-dicyanomethylene-4H-pyran)-2,6-vinylene-1,4-phenylenevinylene-2,5-bis(dodecyloxy)-1,4-phenylenevinylene (PM-PPV) as the emitting layer, which have HOMO and LUMO energy levels of -5.44 eV and -3.48 eV, respectively. The bilayered device had much enhanced the maximum efficiency (0.024 cd/A) and luminescence ($45cd/m^2$) than those of a single layer device (ITO/PM-PPV/Al, 0.003 cd/A, $3cd/m^2$). The enhanced performance originated from that fact that cross-linked Cross-PPV facilitatse the hole injection to the emissive layer and the injected hole and electron from ITO and Al are recombined in emitting layer (PM-PPV) effectively.

Two Cases of Long-Term Changes in the Retinal Nerve Fiber Layer Thickness after Intravitreal Bevacizumab for Diabetic Papillopathy (당뇨병유두병증에서 유리체강내 베바시주맙 주입술 후 망막시경섬유층 두께의 장기간 변화 2예)

  • Kim, Jong Jin;Im, Jong Chan;Shin, Jae Pil;Kim, In Taek;Park, Dong Ho
    • Journal of The Korean Ophthalmological Society
    • /
    • v.54 no.9
    • /
    • pp.1445-1451
    • /
    • 2013
  • Purpose: To report long-term changes in the average retinal nerve fiber layer (RNFL) thickness in 2 patients who had intravitreal bevacizumab (IVB) injection for diabetic papillopathy. Case summary: A 36-year-old patient with diabetes complained of decreased visual acuity (20/200) in the right eye. The fundus examination showed optic disc swelling in both eyes. The average RNFL thickness based on optical coherence tomography (OCT) increased to $278{\mu}m$ and Goldmann perimetry showed nasal visual field defect in the right eye. The IVB was injected into the right eye. Three weeks after the IVB injection, RNFL thickness decreased to $135{\mu}m$ and visual acuity improved to 20/25 in the right eye. However, RNFL thickness increased from 126 to $207{\mu}m$ and visual acuity decreased to 20/32 in the left eye. Thus, IVB was injected into the left eye. In week 3, RNFL thickness decreased to $147{\mu}m$ and visual acuity improved to 20/20 in the left eye. At 12 months after IVB injection, RNFL thickness was $87{\mu}m$ in the right eye and $109{\mu}m$ in the left eye. A 57-year-old patient with diabetes complained of decreased visual acuity (20/200) and showed optic disc swelling in the right eye. The average RNFL thickness increased to $252{\mu}m$ and Goldmann perimetry showed an enlarged blind spot in the right eye. IVB was injected into the right eye. After 3 weeks, RNFL thickness decreased to $136{\mu}m$ and visual acuity improved to 20/70 in the right eye. Six months after IVB injection, RNFL thickness was $83{\mu}m$ in the right eye. Conclusions: Visual acuity progressively improved within 3 weeks and RNFL thickness measured by spectral domain OCT showed progressive thickness reduction in 2 cases of diabetic papillopathy patients who had IVB injections.

Long-term Results of Taking Anti-oxidant Nutritional Supplement in Intermediate Age-related Macular Degeneration (중기 나이관련황반변성 환자에서 항산화영양제 복용 후 장기 관찰 결과)

  • Bang, Seul Ki;Kim, Eung Suk;Kim, Jong Woo;Shin, Jae Pil;Lee, Ji Eun;Yu, Hyeong Gon;Huh, Kuhl;Yu, Seung-Young
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1152-1159
    • /
    • 2018
  • Purpose: We prospectively investigated clinical changes and long-term outcomes after administration of the drugs recommended by the Age-Related Eye Disease Study-2 to patients with intermediate age-related macular degeneration (AMD). Methods: This prospective multicenter study enrolled 79 eyes of 55 patients taking lutein and zeaxanthin. The primary endpoint was contrast sensitivity; this was checked every 12 months for a total of 36 months after treatment commenced. The secondary endpoints were visual acuity, central macular thickness, and drusen volume; the latter two parameters were assessed using spectral domain optical coherence tomography. Results: The mean patient age was $72.46{\pm}7.16years$. Contrast sensitivity gradually improved at both three and six cycles per degree. The corrected visual acuity was $0.13{\pm}0.14logMAR$ and did not change significantly over the 36 months. Neither the central macular thickness nor drusen volume changed significantly. Conclusions: Contrast sensitivity markedly improved after treatment, improving vision and patient satisfaction. Visual acuity, central retinal thickness, and drusen volume did not deteriorate. Therefore, progression of AMD and visual function deterioration were halted.

Choroidal Thickness in Thyroid-associated Ophthalmopathy between Normal Tension Glaucoma Using Optical Coherence Tomography (스펙트럼영역 빛간섭단층촬영으로 측정한 갑상선 안병증 환자와 녹내장환자의 맥락막 두께 분석)

  • Lee, Bo Young;La, Tae Yoon;Choi, Jin A
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.8
    • /
    • pp.960-967
    • /
    • 2017
  • Purpose: To compare the macular choroidal thickness in patients with thyroid-associated ophthalmopathy (TAO) with those with normal tension glaucoma (NTG). Methods: A total of 70 normal eyes, 74 eyes with TAO and 60 eyes with NTG were enrolled in this study. All patients underwent spectral-domain optical coherence tomography (SD-OCT) (Cirrus HD-OCT, Carl Zeiss Meditec Inc., Dublin, CA, USA). Macular choroidal thickness was assessed using enhanced depth imaging. The average macular choroidal thickness was defined as the average value of three measurements: at the fovea and at the points located 1.5 mm in the nasal and temporal directions from the fovea. Generalized estimating equations were used to uncover factors affecting the average macular choroidal thickness. Results: The average, superior and inferior quadrant retinal nerve fiber layer thicknesses were significantly thinner in the NTG group compared with the TAO and control groups (p < 0.001). The average macular choroidal thickness of the TAO group, NTG group and controls was $281.01{\pm}60.06{\mu}m$, $241.66{\pm}55.00{\mu}m$ and $252.07{\pm}55.05{\mu}m$, respectively, which were significantly different (p = 0.013). The subfoveal, nasal and temporal side choroidal thicknesses were significantly thinner in the NTG group compared with the TAO group (p = 0.014, 0.012 and 0.034, respectively). Subjects with TAO were associated with a thicker average macular choroidal thickness compared with the NTG group after adjusting for age, sex, spherical equivalent and intraocular pressure (${\beta}=32.61$, p = 0.017). Conclusions: Macular choroidal thickness was significantly thicker in patients with TAO compared with those with NTG. Further evaluation is required to determine if a thick choroid in subjects with TAO has any role in glaucomatous optic neuropathy.

Estimation of Precipitable Water from the GMS-5 Split Window Data (GMS-5 Split Window 자료를 이용한 가강수량 산출)

  • 손승희;정효상;김금란;이정환
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.1
    • /
    • pp.53-68
    • /
    • 1998
  • Observation of hydrometeors' behavior in the atmosphere is important to understand weather and climate. By conventional observations, we can get the distribution of water vapor at limited number of points on the earth. In this study, the precipitable water has been estimated from the split window channel data on GMS-5 based upon the technique developed by Chesters et al.(1983). To retrieve the precipitable water, water vapor absorption parameter depending on filter function of sensor has been derived using the regression analysis between the split window channel data and the radiosonde data observed at Osan, Pohang, Kwangiu and Cheju staions for 4 months. The air temperature of 700 hPa from the Global Spectral Model of Korea Meteorological Administration (GSM/KMA) has been used as mean air temperature for single layer radiation model. The retrieved precipitable water for the period from August 1996 through December 1996 are compared to radiosonde data. It is shown that the root mean square differences between radiosonde observations and the GMS-5 retrievals range from 0.65 g/$cm^2$ to 1.09 g/$cm^2$ with correlation coefficient of 0.46 on hourly basis. The monthly distribution of precipitable water from GMS-5 shows almost good representation in large scale. Precipitable water is produced 4 times a day at Korea Meteorological Administration in the form of grid point data with 0.5 degree lat./lon. resolution. The data can be used in the objective analysis for numerical weather prediction and to increase the accuracy of humidity analysis especially under clear sky condition. And also, the data is a useful complement to existing data set for climatological research. But it is necessary to get higher correlation between radiosonde observations and the GMS-5 retrievals for operational applications.

A Reflectance Normalization Via BRDF Model for the Korean Vegetation using MODIS 250m Data (한반도 식생에 대한 MODIS 250m 자료의 BRDF 효과에 대한 반사도 정규화)

  • Yeom, Jong-Min;Han, Kyung-Soo;Kim, Young-Seup
    • Korean Journal of Remote Sensing
    • /
    • v.21 no.6
    • /
    • pp.445-456
    • /
    • 2005
  • The land surface parameters should be determined with sufficient accuracy, because these play an important role in climate change near the ground. As the surface reflectance presents strong anisotropy, off-nadir viewing results a strong dependency of observations on the Sun - target - sensor geometry. They contribute to the random noise which is produced by surface angular effects. The principal objective of the study is to provide a database of accurate surface reflectance eliminated the angular effects from MODIS 250m reflective channel data over Korea. The MODIS (Moderate Resolution Imaging Spectroradiometer) sensor has provided visible and near infrared channel reflectance at 250m resolution on a daily basis. The successive analytic processing steps were firstly performed on a per-pixel basis to remove cloudy pixels. And for the geometric distortion, the correction process were performed by the nearest neighbor resampling using 2nd-order polynomial obtained from the geolocation information of MODIS Data set. In order to correct the surface anisotropy effects, this paper attempted the semiempirical kernel-driven Bi- directional Reflectance Distribution Function(BRDF) model. The algorithm yields an inversion of the kernel-driven model to the angular components, such as viewing zenith angle, solar zenith angle, viewing azimuth angle, solar azimuth angle from reflectance observed by satellite. First we consider sets of the model observations comprised with a 31-day period to perform the BRDF model. In the next step, Nadir view reflectance normalization is carried out through the modification of the angular components, separated by BRDF model for each spectral band and each pixel. Modeled reflectance values show a good agreement with measured reflectance values and their RMSE(Root Mean Square Error) was totally about 0.01(maximum=0.03). Finally, we provide a normalized surface reflectance database consisted of 36 images for 2001 over Korea.

Assembly and Testing of a Visible and Near-infrared Spectrometer with a Shack-Hartmann Wavefront Sensor (샤크-하트만 센서를 이용한 가시광 및 근적외선 분광기 조립 및 평가)

  • Hwang, Sung Lyoung;Lee, Jun Ho;Jeong, Do Hwan;Hong, Jin Suk;Kim, Young Soo;Kim, Yeon Soo;Kim, Hyun Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.3
    • /
    • pp.108-115
    • /
    • 2017
  • We report the assembly procedure and performance evaluation of a visible and near-infrared spectrometer in the wavelength region of 400-900 nm, which is later to be combined with fore-optics (a telescope) to form a f/2.5 imaging spectrometer with a field of view of ${\pm}7.68^{\circ}$. The detector at the final image plane is a $640{\times}480$ charge-coupled device with a $24{\mu}m$ pixel size. The spectrometer is in an Offner relay configuration consisting of two concentric, spherical mirrors, the secondary of which is replaced by a convex grating mirror. A double-pass test method with an interferometer is often applied in the assembly process of precision optics, but was excluded from our study due to a large residual wavefront error (WFE) in optical design of 210 nm ($0.35{\lambda}$ at 600 nm) root-mean-square (RMS). This results in a single-path test method with a Shack-Hartmann sensor. The final assembly was tested to have a RMS WFE increase of less than 90 nm over the entire field of view, a keystone of 0.08 pixels, a smile of 1.13 pixels and a spectral resolution of 4.32 nm. During the procedure, we confirmed the validity of using a Shack-Hartmann wavefront sensor to monitor alignment in the assembly of an Offner-like spectrometer.

Quantitative Elemental Analysis in Soils by using Laser Induced Breakdown Spectroscopy(LIBS) (레이저유도붕괴분광법을 활용한 토양의 정량분석)

  • Zhang, Yong-Seon;Lee, Gye-Jun;Lee, Jeong-Tae;Hwang, Seon-Woong;Jin, Yong-Ik;Park, Chan-Won;Moon, Yong-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.5
    • /
    • pp.399-407
    • /
    • 2009
  • Laser induced breakdown spectroscopy(LIBS) is an simple analysis method for directly quantifying many kinds of soil micro-elements on site using a small size of laser without pre-treatment at any property of materials(solid, liquid and gas). The purpose of this study were to find an optimum condition of the LIBS measurement including wavelengths for quantifying soil elements, to relate spectral properties to the concentration of soil elements using LIBS as a simultaneous un-breakdown quantitative analysis technology, which can be applied for the safety assessment of agricultural products and precision agriculture, and to compare the results with a standardized chemical analysis method. Soil samples classified as fine-silty, mixed, thermic Typic Hapludalf(Memphis series) from grassland and uplands in Tennessee, USA were collected, crushed, and prepared for further analysis or LIBS measurement. The samples were measured using LIBS ranged from 200 to 600 nm(0.03 nm interval) with a Nd:YAG laser at 532 nm, with a beam energy of 25 mJ per pulse, a pulse width of 5 ns, and a repetition rate of 10 Hz. The optimum wavelength(${\lambda}nm$) of LIBS for estimating soil and plant elements were 308.2 nm for Al, 428.3 nm for Ca, 247.8 nm for T-C, 438.3 nm for Fe, 766.5 nm for K, 85.2 nm for Mg, 330.2 nm for Na, 213.6 nm for P, 180.7 nm for S, 288.2 nm for Si, and 351.9 nm for Ti, respectively. Coefficients of determination($r^2$) of calibration curve using standard reference soil samples for each element from LIBS measurement were ranged from 0.863 to 0.977. In comparison with ICP-AES(Inductively coupled plasma atomic emission spectroscopy) measurement, measurement error in terms of relative standard error were calculated. Silicon dioxide(SiO2) concentration estimated from two methods showed good agreement with -3.5% of relative standard error. The relative standard errors for the other elements were high. It implies that the prediction accuracy is low which might be caused by matrix effect such as particle size and constituent of soils. It is necessary to enhance the measurement and prediction accuracy of LIBS by improving pretreatment process, standard reference soil samples, and measurement method for a reliable quantification method.

Detection of Forest Fire Damage from Sentinel-1 SAR Data through the Synergistic Use of Principal Component Analysis and K-means Clustering (Sentinel-1 SAR 영상을 이용한 주성분분석 및 K-means Clustering 기반 산불 탐지)

  • Lee, Jaese;Kim, Woohyeok;Im, Jungho;Kwon, Chunguen;Kim, Sungyong
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_3
    • /
    • pp.1373-1387
    • /
    • 2021
  • Forest fire poses a significant threat to the environment and society, affecting carbon cycle and surface energy balance, and resulting in socioeconomic losses. Widely used multi-spectral satellite image-based approaches for burned area detection have a problem in that they do not work under cloudy conditions. Therefore, in this study, Sentinel-1 Synthetic Aperture Radar (SAR) data from Europe Space Agency, which can be collected in all weather conditions, were used to identify forest fire damaged area based on a series of processes including Principal Component Analysis (PCA) and K-means clustering. Four forest fire cases, which occurred in Gangneung·Donghae and Goseong·Sokcho in Gangwon-do of South Korea and two areas in North Korea on April 4, 2019, were examined. The estimated burned areas were evaluated using fire reference data provided by the National Institute of Forest Science (NIFOS) for two forest fire cases in South Korea, and differenced normalized burn ratio (dNBR) for all four cases. The average accuracy using the NIFOS reference data was 86% for the Gangneung·Donghae and Goseong·Sokcho fires. Evaluation using dNBR showed an average accuracy of 84% for all four forest fire cases. It was also confirmed that the stronger the burned intensity, the higher detection the accuracy, and vice versa. Given the advantage of SAR remote sensing, the proposed statistical processing and K-means clustering-based approach can be used to quickly identify forest fire damaged area across the Korean Peninsula, where a cloud cover rate is high and small-scale forest fires frequently occur.

GOCI-II Capability of Improving the Accuracy of Ocean Color Products through Fusion with GK-2A/AMI (GK-2A/AMI와 융합을 통한 GOCI-II 해색 산출물 정확도 개선 가능성)

  • Lee, Kyeong-Sang;Ahn, Jae-Hyun;Park, Myung-Sook
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_2
    • /
    • pp.1295-1305
    • /
    • 2021
  • Satellite-derived ocean color products are required to effectively monitor clear open ocean and coastal water regions for various research fields. For this purpose, accurate correction of atmospheric effect is essential. Currently, the Geostationary Ocean Color Imager (GOCI)-II ground segment uses the reanalysis of meteorological fields such as European Centre for Medium-Range Weather Forecasts (ECMWF) or National Centers for Environmental Prediction (NCEP) to correct gas absorption by water vapor and ozone. In this process, uncertainties may occur due to the low spatiotemporal resolution of the meteorological data. In this study, we develop water vapor absorption correction model for the GK-2 combined GOCI-II atmospheric correction using Advanced Meteorological Imager (AMI) total precipitable water (TPW) information through radiative transfer model simulations. Also, we investigate the impact of the developed model on GOCI products. Overall, the errors with and without water vapor absorption correction in the top-of-atmosphere (TOA) reflectance at 620 nm and 680 nm are only 1.3% and 0.27%, indicating that there is no significant effect by the water vapor absorption model. However, the GK-2A combined water vapor absorption model has the large impacts at the 709 nm channel, as revealing error of 6 to 15% depending on the solar zenith angle and the TPW. We also found more significant impacts of the GK-2 combined water vapor absorption model on Rayleigh-corrected reflectance at all GOCI-II spectral bands. The errors generated from the TOA reflectance is greatly amplified, showing a large error of 1.46~4.98, 7.53~19.53, 0.25~0.64, 14.74~40.5, 8.2~18.56, 5.7~11.9% for from 620 nm to 865 nm, repectively, depending on the SZA. This study emphasizes the water vapor correction model can affect the accuracy and stability of ocean color products, and implies that the accuracy of GOCI-II ocean color products can be improved through fusion with GK-2A/AMI.