• Title/Summary/Keyword: speckle

Search Result 484, Processing Time 0.026 seconds

Applicability estimation of ESPI on the vibration mode analysis of rectangular plate (직사각형 평판의 진동모드 해석에 관한 ESPI의 적용성 평가)

  • 김경석;정현철;박경주;양승필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.61-67
    • /
    • 1997
  • The electronic speckle pattern interferometer (ESPI) has been applied to many technical problems such as deformation and displacement measurement, strain visualization and surface roughness monitoring. In this study, we used an ESPI system based on the dual beam speckle interferometer method in order to measure in-plane displacement and vibration mode using the ESIP technique. This research was carried out for the purpose of applying the vibration analysis method employing Electro-Optic holographic interference technique to the vibration analysis of uniform rectangular cantilevers plate(SS400,STS304) with cantilevers span to breadth ratio of 150 by 75. And thickness of 1mm and 0.8mm respectively. We improved the ESPI technique in order to obtain the distribution of displacement component resolved in one direction through a CCD camera combined with an image processing system. To certify and to assess the accuracy in measuring by this ESPI, the results obtained with the speckle method and vibration mode analysis are to be compared with those results by Warbuton's Theoretical expression and vibration made in FEM analysis.

  • PDF

Laser Speckle Contrast Imaging for Measuring Cerebral Blood Flow Changes Caused by Electrical Sensory Stimulation

  • Cho, Ahra;Yeon, Chanmi;Kim, Donghyeon;Chung, Euiheon
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.88-93
    • /
    • 2016
  • Recently laser speckle contrast (LSC) imaging has become a widely used optical method for in vivo assessment of blood flow in the animal brain. LSC imaging is useful for monitoring brain hemodynamics with relatively high spatio-temporal resolution. A speckle contrast imaging system has been implemented with electrical sensory stimulation apparatus. LSC imaging is combined with optical intrinsic signal imaging in order to measure changes in cerebral blood flow as well as neural activity in response to electrical sensory stimulation applied to the hindlimb region of the mouse brain. We found that blood flow and oxygen consumption are correlated and both sides of hindlimb activation regions are symmetrically located. This apparatus could be used to monitor spatial or temporal responses of cerebral blood flow in animal disease models such as ischemic stroke or cortical spreading depression.

A NOVEL PARALLEL METHOD FOR SPECKLE MASKING RECONSTRUCTION USING THE OPENMP

  • LI, XUEBAO;ZHENG, YANFANG
    • Journal of The Korean Astronomical Society
    • /
    • v.49 no.4
    • /
    • pp.157-162
    • /
    • 2016
  • High resolution reconstruction technology is developed to help enhance the spatial resolution of observational images for ground-based solar telescopes, such as speckle masking. Near real-time reconstruction performance is achieved on a high performance cluster using the Message Passing Interface (MPI). However, much time is spent in reconstructing solar subimages in such a speckle reconstruction. We design and implement a novel parallel method for speckle masking reconstruction of solar subimage on a shared memory machine using the OpenMP. Real tests are performed to verify the correctness of our codes. We present the details of several parallel reconstruction steps. The parallel implementation between various modules shows a great speed increase as compared to single thread serial implementation, and a speedup of about 2.5 is achieved in one subimage reconstruction. The timing result for reconstructing one subimage with 256×256 pixels shows a clear advantage with greater number of threads. This novel parallel method can be valuable in real-time reconstruction of solar images, especially after porting to a high performance cluster.

Speckle Noise Reduction in SAR Images using Wavelet Transform (SAR 영상에서 웨이블렛 변환을 이용한 스펙클 잡음제거 방법)

  • Lim, Dong-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.3
    • /
    • pp.123-130
    • /
    • 2007
  • It is difficult to analyse images because of multiplicative characteristics of speckle noises in SAR images. In this paper. wavelet transform is proposed for restoring SAR images corrupted by speckle noise. The multiplicative noise is transformed into a form of additive noise and then the additive noise is denoised using wavelet thresholding selections such as VisuShrink, SureShrink, BayesShrink and modified BayesShrink. Experimental results on several test images show that the modified BayesShrink yields significantly superior image quality and better Peak Signal to Noise Ratio(PSNR).

  • PDF

RESIDUAL STRESS MEASUREMENT ON THE BUTT-WELDED AREA BY ELECTRONIC SPECKLE PATTERN INTERFEROMETRY

  • KIM, KYEONGSUK;CHOI, TAEHO;NA, MAN GYUN;JUNG, HYUNCHUL
    • Nuclear Engineering and Technology
    • /
    • v.47 no.1
    • /
    • pp.115-125
    • /
    • 2015
  • Background: Residual stress always exists on any kind of welded area. This residual stress can cause the welded material to crack or fracture. For many years, the hole-drilling method has been widely used for measuring residual stress. However, this method is destructive. Nowadays, electronic speckle pattern interferometry (ESPI) can be used to measure residual stress with or without the hole-drilling method. ESPI is an optical nondestructive testing methods that use the speckle effect. Mechanical properties can be measured by calculation of the phase difference by the variation of temperature, pressure, or loading force. Methods: In this paper, the residual stress on the butt-welded area is measured by using ESPI with a suggested numerical calculation. Two types of specimens are prepared. Type I is made of pure base metal part and type II has a welded part at the center. These specimens are tensile tested with a material test system. At the same time, the ESPI system was applied to this test. Results: From the results of ESPI, the elastic modulus and the residual stress around the welded area can be calculated and estimated. Conclusion: With this result, it is confirmed that the residual stress on the welded area can be measured with high precision by ESPI.

Enhancement of the Ultrasonic Image Using the Adaptive Window Log Filter for NDI of Aircraft Composite Materials (항공기 복합 재료의 비파괴 검사(NDI)를 위한 가변 창 필터를 이용한 초음파 영상 개선)

  • Hong, G.Y.;Hong, S.B.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.11 no.2
    • /
    • pp.33-42
    • /
    • 2003
  • In this paper, we propose an enhancement of the ultrasonic image for non-destructive inspection of aircraft composite materials. The ultrasonic images are corrupted by a speckle noise which has the characteristic of granular pattern noise and is in all types of coherent imaging systems, the signal independent and multiplicative noise. In this paper, we derive a filter, called the AWLF(Adaptive Window Log Filter), from the nature of the speckle. The filter is made of the MEAN Filter in the edge region and Log Filter in the flat or noise region. To make a distinction between edge and flat region, we calculate the inclination around the local window instead of computing the local statistics of pixels such as local mean ${\bar{M}}$ and standard deviation ${\sigma}_s$. According to the obtained region, edge region is performed by the mean filter and flat region by the Log filter. Performance of the proposed filter is evaluated by the Enhanced Factor$(F_e)$ and the Speckle Index(SI).

  • PDF

Two-dimensional speckle-tracking of antral contraction in dogs

  • Park, Junghyun;An, Soyon;Hwang, Tae Sung;Lee, Hee Chun
    • Korean Journal of Veterinary Research
    • /
    • v.60 no.2
    • /
    • pp.55-59
    • /
    • 2020
  • This study was purposed to make the referenced range of stomach antral contraction strain in 50 dogs using 2-dimensional speckle tracking. In addition, the strain results were compared among body condition scores to reveal the correlations of obesity among the subjects of the study. Finally, the medetomidine group that was comprised of 10 dogs was compared with the normal group to identify the medetomidine pharmacologic effect in the stomach antral contraction. Clinically healthy 50 dogs were recruited for the study. In an ultrasonographic examination, the stomach antrum region was scanned, and at least one cycle of antral contraction was recorded. The peak strain of antral contraction in healthy dogs was 58.2 ± 20.47% (mean ± SD). The obesity group showed a high strain result and there were significant correlations between the body condition score (BCS) 2, BCS 3 groups and BCS 8 group. The medetomidine group revealed a low strain result and was significantly correlated with normal group. Two-dimensional speckle tracking was useful to the evaluation of stomach motility disorders.

Development Of Four-Dimensional Digital Speckle Tomography For Experimental Analysis Of High-Speed Helium Jet Flow (고속 헬륨 제트 유동의 실험적 분석을 위한 4차원 디지털 스펙클 토모그래피 기법 개발)

  • Ko, Han-Seo;Kim, Yong-Jae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.2
    • /
    • pp.193-203
    • /
    • 2006
  • A high-speed and initial helium jet flow has been analyzed by a developed four-dimensional digital speckle tomography. Multiple high-speed cameras have been used to capture movements of speckles in multiple angles of view simultaneously because a shape of a nozzle for the jet flow is asymmetric and the initial jet flow is fast and unsteady. The speckle movements between no flow and helium jet flow from the asymmetric nozzle controlled by a solenoid valve have been obtained by a cross-correlation tracking method so that those distances can be transferred to deflection angles of laser rays for density gradients. The four-dimensional density fields for the high-speed helium jet flow have been reconstructed from the deflection angles by a developed real-time tomography method.

A Study of Measurement of In-plane Displacement by CW Laser Speckle Photography and Image Processing (연속파 레이저 스페클 사진법(寫眞法)과 화상처리(畵像處理)에 의한 면내섭위(面內燮位) 측정(測定)에 관한 연구(硏究))

  • Kim, K.S.;Na, G.D.;Kim, T.H.;Chung, N.K.;Kim, C.W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.1
    • /
    • pp.47-55
    • /
    • 1990
  • This paper presents experimental results which explore the capability of a CW laser speckle photography for tile measurement of in-plane displacement at high temperature. The serious restrictions on the application of the method seem to be the ambient air turbulence and the change of surface texture caused by the oxidation, as they tend to decorrelate the double exposured speckle patterns. In order to assess only the effect of air turbulence, a ceramics-coated stainless steel plate is heated in air and Ar-laser specklegrams are made with combination of temperature and lateral translation displacement. The slight reduction in visibility of Young's fringes is observed at $1000^{\circ}C$. The analyses of Young's fringes are carried out by a image processing system using a TV-camera and computers, and the result agrees well with the micrometer reading. Futhermore, uncoated stainless steel and Hastelloy X plates are tested and the effect of oxidation is also evaluated. The experimental results demonstrate that a CW laser speckle photography is applicable at temperatures up to $1000^{\circ}C$.

  • PDF

Speckle Removal of SAR Imagery Using a Point-Jacobian Iteration MAP Estimation

  • Lee, Sang-Hoon
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.1
    • /
    • pp.33-42
    • /
    • 2007
  • In this paper, an iterative MAP approach using a Bayesian model based on the lognormal distribution for image intensity and a GRF for image texture is proposed for despeckling the SAR images that are corrupted by multiplicative speckle noise. When the image intensity is logarithmically transformed, the speckle noise is approximately Gaussian additive noise, and it tends to a normal probability much faster than the intensity distribution. MRFs have been used to model spatially correlated and signal-dependent phenomena for SAR speckled images. The MRF is incorporated into digital image analysis by viewing pixel types as slates of molecules in a lattice-like physical system defined on a GRF Because of the MRF-SRF equivalence, the assignment of an energy function to the physical system determines its Gibbs measure, which is used to model molecular interactions. The proposed Point-Jacobian Iterative MAP estimation method was first evaluated using simulation data generated by the Monte Carlo method. The methodology was then applied to data acquired by the ESA's ERS satellite on Nonsan area of Korean Peninsula. In the extensive experiments of this study, The proposed method demonstrated the capability to relax speckle noise and estimate noise-free intensity.