• Title/Summary/Keyword: specimen depth

Search Result 543, Processing Time 0.021 seconds

HYDROLYTIC DEGRADATION OF DENIAL COMPOSITE RESINS (수종 치과용 복합레진의 가수분해)

  • Yang, Kyu-Ho;Kim, Jung-Ran
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.370-378
    • /
    • 2000
  • The composite restorative resins have their insufficient resistance to wear. The subsurface degradation within the restoration is considered to be associated with wear. The aim of this study was to evaluate the resistance to degradation of six commercial composite resins in an alkaline solution. The brands studied were Clearfil APX(Kuraray), Heliomolar(Vivadent), Surefil(Dentsply), TPH(Dentsply), Tetric Ceram(Vivadent), and Z100(3M). Preweighed discs of each brand were exposed 0.1N NaOH solution at $60^{\circ}C$. After 14 days they were removed, neutralized with HCL, washed with water and dried to constant mass at $60^{\circ}C$. Resistance to degradation was evaluated on the basis of the following parameters: (a) mass loss(%) - determined from pre-and post-exposure specimen weights; (b) Si loss (ppm)-obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation depth$({\mu}m)$ - measured microscopically (SEM) from polished circular sections of exposed specimens. The results were as follows: 1. The mass loss was in descending order by Z100, TC H, S, CL, TPH and in the range of $0.45\sim3.64%$ 2. The degradation layer depth was in descending order by H, Z100, S, TC, TPH, CL and in the range of $10.85\sim73.38{\mu}m$ 3. For the Si concentration, Z100 was the highest of all 4. The highly significant correlation(r=0.81, p<0.05) was observed between mass loss and degradation depth. 5. Under scanning electronmicroscopy, the degradation of connection between resin matrix and fillers was observed 2 weeks after soaking in NaOH solution.

  • PDF

Histopathologic Changes of Articular Cartilage and Subchondral Bone in Cylindrical Biopsy Specimen from Talar Osteochondral Lesions (거골의 골연골 병변의 원주형 생검에서 관절 연골과 연골하 골의 조직병리학적 변화)

  • Lee, Ho-Seong;Jang, Jae-Suk;Lee, Jong-Suk;Cho, Kyung-Ja;Lee, Sang-Hoon;Jung, Hong-Keun;Kim, Yong-Min
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.2
    • /
    • pp.117-124
    • /
    • 2006
  • Purpose: This study was aimed at elucidating the pathogenesis of talar osteochondral lesion by analyzing the histopathological findings. Materials and Methods: Twenty specimens from 20 patients who underwent surgical treatment for talus osteochondral lesions were studied. Preoperative MRI images including T1, T2, and stir images were taken and cases were classified according to modification of the Anderson's classification. There were 5 cases of MRI group 1, 6 cases of group 2, 7 cases of group 3 and 2 cases of group 4. A full thickness osteochondral plug including the osteochondral lesion of the talus was harvested from each patient and reviewed histopathologic changes of osteochondral fragment using H-E staining. Mean diameter of specimens was 8.5 mm and mean depth was 10.3 mm. Pathologic changes of articular cartilage and subchondral bone were observed. Subchondral bone was divided into superficial, middle and deep zones according to depth. Cartilage formation, trabecular thickening and marrow fibrosis were observed in each zone. Results: There were detachment of the joint cartilage at the tidemark in 16 cases of 20 cases and the separated cartilages were almost necrotic on the histopathologic findings. Cartilage formation within subchondral bone was discovered beneath the tidemark in 12 cases. Trabeculae were increased and thickened in 17 cases. These pathologic changes were similar to fracture healing process and these findings were more conspicuous near the tidemark and showed transition to normal bone marrow tissue with depth. No correlation between the pathological progression and MRI stages was found. A large cyst shown on MRI's was microscopically turned out to be multiple micro-cysts accompanied by fibrovascular structure and newly formed cartilage tissue. Conclusion: The histopathologic findings of osteochondral lesions are detachment of overlying cartilage at the tidemark and subsequent changes of subchondral bone. Subchondral bone changes are summarized as cartilage formation, marrow fibrosis and trabecular thickening that mean healing process following repeated micro fractures of trabecular. These osteochondral lesions should have differed from osteochondral fractures.

  • PDF

A Study on Field Applicability of Underground Electric Heating Mesh (매설용 전기 발열 매시의 융설 효과에 대한 현장 적용성 연구)

  • Suh, Young-Chan;Seo, Byung-Seok;Song, Jung-Kon;Cho, Nam-Hyun
    • International Journal of Highway Engineering
    • /
    • v.15 no.2
    • /
    • pp.19-27
    • /
    • 2013
  • PURPOSES : This study aims to investigate the snow-melt effects of an underground electric heater's snow-melt system via a field performance test, for evaluating the suitability of the system for use on a concrete pavement. The study also investigates the effectiveness of dynamic measures for clearing snow after snowfall events. METHODS : In order to check the field applicability, in November 2010, specimens were prepared from materials used for constructing concrete pavements, and underground electric heating meshes (HOT-mesh) were buried at depths of 50 mm and 100 mm at the site of the Incheon International Airport Construction Research Institute. Further, an automatic heating control system, including a motion sensor and pavement-temperature-controlled sensor, were installed at the site; the former sensor was intended for determining snow-melt effects of the heating control system for different snowfall intensities. Pavement snow-melt effects on snowy days from December 2010 to January 2011 were examined by managing the electric heating meshes and the heating control system. In addition, data on pavement temperature changes resulting from the use of the heating meshes and heating control system and on the dependence of the correlation between the outdoor air temperature and the time taken for the required temperature rise on the depth of the heating meshes were collected and analyzed. RESULTS : The effects of the heating control system's preheat temperature and the hot meshes buried at depths of 50 mm and 100 mm on the melting of snow for snowfalls of different intensities have been verified. From the study of the time taken for the specimen's surface temperature to increase from the preheat temperature ($0^{\circ}C$) to the reference temperature ($5{\sim}8^{\circ}C$) for different snowfall intensities, the correlation between the burial depth and outdoor air temperature has been determined to be as follows: Time=15.10+1.141Depth-6.465Temp CONCLUSIONS : The following measures are suggested. For the effective use of the electric heating mesh, it should be located under a slab it may be put to practical use by positioning it under a slab. From the management aspect, the heating control system should be adjusted according to weather conditions, that is, the snowfall intensity.

Experimental Study for GFRP Reinforced Concrete Beams without Stirrups (스터럽이 없는 GFRP 보강근 콘크리트 보에 대한 실험적 연구)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.21-29
    • /
    • 2014
  • This paper evaluates the shear strength, behavior and failure mode of reinforced concrete beams with deformed GFRP reinforcing bar. Four concrete beam specimens were constructed and tested. It was carried out to observe failure behavior and load-deflection of simply supported concrete beams subjected to four-point monotonic loading. In order to eliminate of the uncertainty by the shear reinforcements, any stirrups were not used. Variables of the specimens were shear span-depth ratio, effective reinforcement ratio. The dimensions of specimen is 3,300 or $1,950mm{\times}200mm{\times}240mm$. Clear span and shear span were 2,900mm, 1,000mm respectively. Shear span-depth ratios were 6.5 and 2.5. Effective ratios of Longitudinal GFRP reinforcing bar were $1.126{\rho}_{fb}$, $2.250{\rho}_{fb}$, $3.375{\rho}_{fb}$ and $0.634{\rho}_{fb}$. All beam specimens were broken by diagonal-tension shear and the ACI 440.1R, CSA S806 and ISIS, which was used to design test beams, showed considerable deviation between prediction and test results of shear strengths.

COMPARISON OF APICAL SEALING EFFICACIES USING DIFFERENT PLUGGING DEPTH IN CONTINUOUS WAVE OF OBTURATION TECHNIQUE (Continuous wave of obturation technique에서 플러거의 다양한 적용 깊이에 따른 근단부 폐쇄효율 비교)

  • Lee, Sang-Jin;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.491-497
    • /
    • 2007
  • The purpose of this study was to compare apical sealing ability of continuous wave canal filling technique according to various heat source plugging depths. Eighty one extracted human premolars with straight root were cleaned and shaped to size 35 using .06 taper rotary NiTi file. After cleansing and shaping, the teeth were divided into 5 groups following the heat source probing depths from the apex; 3, 4, 5, 6 and 7 mm. All specimens were filled using E&Q plus with #35/.06 tapered gutta-percha cone. The positive control teeth were not filled. All teeth were coated with nail varnish except the apical 1 mm around the apical foramen. Negative control teeth were completely sealed include the apical foramen. All specimens were immersed in 1% methylene blue solution for 72 hours. Then the specimens were sectioned horizontally at 1, 2 and 3 mm from the root apex. Each sectioned surface was photographed using a digital camera attached to the stereomicroscope at $12.5{\times}2.5$ fold magnification. All points at 1, 2 and 3 mm were summed as final score of one specimen. Statistical analysis of the collected data was performed. Under the condition of this study. there was no significant difference between the heat source plugging depths of 3, 4, 5, 6 and 7 mm in apical sealing ability. All of apical heat source plugging depth from 3 to 7 mm including Buchanan's protocol -from 5 to 7 mm- seems to be acceptable in clinical application.

EFFECT OF INCREMENTAL FILLING TECHNIQUE ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN (적층충전법이 복합레진의 중합수축에 미치는 영향)

  • Kim, Hyo-Suk;Lee, Nan-Young;Lee, Sang-Ho;Oh, You-Hyang
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.481-490
    • /
    • 2005
  • The aim of this study was to investigate the relationship between the C-factor and shrinkage strain values of composite resin and examine the strain values in different incremental filling techniques. The strain gauge method was used for measurement of polymerization shrinkge strain. Experiment was divided two step. In a first experiment, we compared with strain value in three different depth (2mm, 3mm, 4mm) and microhardness of each samples after 24hours were measured. In a second experiment, we examined the strain values in five different filling techniques(Group 1: bulk filling, Group 2: oblique incremental filling, Group 3: horizontal incremental filling, Group 4: vertical incremental filling, Group 5: lining of flowable resin and bulk filling) The results of the present study can be summarized as follows: 1. Composite resin in acrylic molds showed the initial expansion at the early phase of polymerization. 2. Contraction stress was not revealed significant difference between depth of 2mm and 3mm(P>0.05). 3. Contraction stress in sample of 4mm was showed the lowest value(P<0.05). 4. Microhardness of specimen was revealed more difference between upper and lower surface in depth of 4mm than 2 and 3mm(P<0.05). 5. Lining of flowable resin and bulk filling (Group 5) was showed the lowest contraction stress, Group 2 and 3 was showed the highest contraction stress(P<0.05). On the basis above results, the stress that result from the polymerization shrinkage, when incremental curing techniques are used, showed that there is no advantage in incremental placement and curing.

  • PDF

EFFECT OF FLUORIDE IN NATURAL POLYMER ON ENAMEL DEMINERALIZATION (천연고분자 화합물을 이용한 불소겔이 법랑질 탈회에 미치는 영향)

  • Kim, Ji-Yeon;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.1
    • /
    • pp.35-43
    • /
    • 2010
  • We have developed a sodium fluoride containing gelatin and methyl cellulose gel. Cariostatic abilities of those gel were investigated and compared with APF gel and fluoride varnish($Cavityshield^{TM}$). We prepared the bovine tooth samples and divided into two surface, control side and experimental side in same specimen for exclusion of difference between specimens. The experiment was consisted of 4 groups : (I) APF gel : (II) $Cavityshield^{TM}$ : (III) Gelatin F gel : (IV) Methyl cellulose F gel Decalcification were produced by placing each specimen into artificial acidic solution(pH 4.0) for 72 hours. Surface microhardness were measured and depth of demineralization lesion were measured by polarizing light microscope. The results were as follows: 1. The difference of VHN between control and experimental side is smallest in group I (p<0.05). 2. The largest difference was shown in group II (p<0.05). 3. There were no significant difference between group III and IV in microhardness test (p>0.05). 4. The difference of lesion depth is smallest in group I (p<0.05). 5. There were no significant difference between group II, III and IV in lesion depth (p>0.05). The result of the present study indicate that the fluoride containing gelatin and methyl cellulose gel is more effective than APF gel and is similar to fluoride varnish application for prevention of demineralization.

ABRASION AND CHEMICAL DEGRADATION OF LIGHT-CURED COMPOSITE RESIN FOR UPDATED RESIN DEVELOPMENT (차세대 레진개발을 위한 광중합형 복합레진의 마모와 화학적 분해)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Yook, Geun-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.685-695
    • /
    • 2004
  • The aim of this study was to evaluate the resistance to degradation and to compare the wear resistance characteristics of four composite resins in an alkaline solution. The resistance to degradation was evaluated on the basis of mass loss(%), degradation depth(${\mu}m$), Si loss(ppm) and wear depth. The brands studied were Heliomolar flow, Filtek supreme, Point4, Tetric flow. The results were as follows: 1. The sequence of the mass loss was in descending order by Heliomolar flow, Filtek supreme, Point4, Tetric flow. There was significant differences among the materials except Heliomolar flow and Filtek supreme. 2. The sequence of the degree of degradation layer depth was in descending order by Filtek supreme, Heliomolar flow, Tetric flow, Point4. There were significant differences among the materials except Heliomolar flow and Tetric flow. 3. The sequence of Si loss was in descending order by Filtek supreme, Heliomolar flow, Point4, Tetric flow. There were significant differences among the materials except Point 4 and Tetric flow. 4. The sequence of maximum wear depth was in descending order by Heliomolar flow, Point4, Fillet supreme, Tetric flow and there was increasing wear depth on soaking in 0.1N NaOH solution. 5. When observed with SEM, destruction of bonding between matrix and filler was observed and when observed with CLSM, the depth of degradation layer of specimen surface was observed. There results indicate that wear and hydrolytic degradation could be considered to be evaluation factors of composite resins.

  • PDF

CHEMICAL DEGRADATION OF LIGHT-CURED DENTAL COMPOSITE RESINS (수종 치과용 광중합형 복합레진의 화학적 분해)

  • Yang, Kuy-Ho;Choi, Nam-Ki;Park, Mi-Ran;Park, Eun-Hae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.403-411
    • /
    • 2001
  • The aim of this study was to evaluate the resistance to degradation of four commercial composite resins in an alkaline solution. The brands studied were Unifil(GC, Japan), Palfique(Tokuyama Japan). Definite$Degussa-H\ddot{u}ls$ AG, Germany). Revolution(Kerr, U.S.A.). Preweighed discs of each brand were exposed 0.1N NaOH solution at $60^{\circ}C$. After 14 days they were removed, neutralized with HCl, washed with water and dried. Resistance to degradation was evaluated on the basis of following parameters: (a) mass loss(%) - determined from pre-and post-exposed specimen weights; (b) Si loss(ppm) - obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation depth$({\mu}m)$ - measured microscopically (SEM) from polished circular sections of exposed specimens. The results were follows: 1. The mass loss of Unifil was 3.21%, it was the highest of materials. But, there was no significant difference among the materials. 2. The degree of degradation layer depth was $107.69\sim47.40{\mu}m$, the sequence of the degree pf degradation layer depth was in descending order by Unifil, Palfique, Revolution, Definite. There was significant difference among the materials except Palfique and Definite. 3. The Si loss of Paltique was 8940.0ppm, it was the highest. There was significant difference among the materials, except Revolution and Definite(p<0.05). 4. The correlation coefficient between mass loss and degradation depth was relatively high(r = 0.06, p<0.05). 5. There was no significant coefficient correlation between Si loss and mass loss, and/or the degree of degradation layer depth and Si loss. 6. When observed with SEM, destruction of bonding is observed between resin matrix and filler. Above results suggested that the hydrolytic degradation is considered as evaluation factor of composite resins.

  • PDF

WEAR AND CHEMICAL DEGRADATION OF ESTHETIC RESTORATIVE MATERIALS (심미수복 재료의 마모와 화학적 분해)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Kim, Hun-Ju;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.190-201
    • /
    • 2004
  • The aim of this study was to evaluate the resistance to degradation and to compare the wear resistance characteristics of four esthetic restorative materials in an alkaline solution. The brands studied were Charmfil, Charmfil flow(composite resin), Compoglass F and PrimaFlow(compomer). The results were as follows: 1. The mass loss were not significantly different among the materials(p>0.05). 2. The sequence of the degree of degradation layer depth was in descending order by Compoglass F, PrimaFlow, Charmfil, and Charmfil flow. There were significant differences between Compoglass F and the others(p<0.05). 3. The sequence of the Si loss was in descending order by Charmfil flow, Charmfil, PrimaFlow, and Compoglass F. There were significant differences among these materials(p<0.05). 4. When observed with SEM, destruction of bonding between matrix and filler was observed and when observed with CLSM, the depth of degradation layer of specimen surface was observed. 5. The sequence of maximum wear depth was in descending order by Comfoglass, PrimaFlow Charmal, and Charmfil flow. There were significant differences among these materials(p<0.05). 6. The correlation coefficient between Si loss and degradation layer depth (r=0.602, p<0.05) Vicker's hardness number and maximum wear depth (r=0.501, p<0.05) were relatively high. These results indicate that wear and hydrolytic degradation may be considered to be evaluation factors of composite resins and compomers.

  • PDF