• Title/Summary/Keyword: specificity

Search Result 4,464, Processing Time 0.046 seconds

Use of Mammary Lymphoscintigraphy and Intraoperative Radioguided Gamma Probe in Sentinel Lymph Node Biopsy of Breast Cancer (유방암 환자의 전초림프절 생검에서 유방림프신티그라피와 수술 중 감마프로우브의 유용성)

  • Kim, Soon;Zeon, Seok-Kil;Kim, Yu-Sa
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.478-486
    • /
    • 2000
  • Purpose: The sentinel lymph node is defined as the first draining node from a primary tumor and reflects the histologic feature of the remainder of the lymphatic basin status. The aim of this study was to evaluate the usefulness of lymphoscintigraphy and intraoperative radioguided gamma probe for identification and removal of sentinel lymph node in breast cancer. Materials and Methods: Lymphoscintigraphy was performed preoperatively in 15 patients with biopsy proven primary breast cancer. Tc-99m antimony sulfide colloid was injected intradermally at four points around the tumor. Imaging acquisition included dynamic imaging, followed by early and late static images at 2 hours. The sentinel lymph node criteria on lymphoscintigraphy is the first node of the highest uptake in early and late static images. We tagged the node emitting the highest activity both in vivo and ex vivo. Histologic study for sentinel and axillary lymph node investigation was done by Hematoxylin-Eosin staining. Results: On lymphoscintigraphy, three of 15 patients had clear lymphatic vessels in dynamic images, and 11 of 15 patients showed sentinel lymph node in early static image and three in late static 2 hours image. Mean detection time of sentinel lymph node on lymphoscintigraphy was $33.5{\pm}48.4$ minutes. The sentinel lymph node localization and removal by lymphoscintigraphy and intraoperative gamma probe were successful in 14 of 15 patients (detection rate: 93.3%). On lymphoscintigraphy, 14 of 15 patients showed $2.47{\pm}2.00$ sentinel lymph nodes. On intraoperative gamma probe, $2.36{\pm}1.96$ sentinel lymph nodes were detected. In 7 patients with positive results of sentinel lymph node metastasis, 5 patients showed positive results of axillary lymph node (sensitivity: 72%) but two did not. In 7 patients with negative results of sentinel lymph node metastasis, all axillary nodes were free of disease (specificity: 100%). Conclusion: Sentinel lymph node biopsy with lymphoscintigraphy and intraoperative gamma probe is a reliable method to predict axillary lymph node metastasis in breast cancer, and unnecessary axillary lymph node dissection can be avoided.

  • PDF

The Differentiation of Benign from Maligant Soft Tissue Lesions using FDG-PET: Comparison between Semi-quantitative Indices (FDG-PET을 이용한 악성과 양성 연부조직 병변의 감별: 반정량적 지표간의 비교)

  • Choi, Joon-Young;Lee, Kyung-Han;Choe, Yearn-Seong;Choi, Yong;Kim, Sang-Eun;Seo, Jai-Gon;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.90-101
    • /
    • 1997
  • The purpose of this study is to evaluate the diagnostic accuracy of various quantitative indices for the differentiation of benign from malignant primary soft tissue tumors by FDG-PET. A series of 32 patients with a variety of histologically or clinically confirmed benign (20) or malignant (12) soft tissue lesions were evaluated with emission whole body (5min/bed position) PET after injection of [$^{18}F$]FDG. Regional 20min transmission scan for the attenuation correction and calculation of SUV was performed in 16 patients (10 benign, 6malignant) followed by dynamic acquisition for 56min. Postinjection transmission scan for the attenuation correction and calculation of SUV was executed in the other 16 patients (10 benign, 6 malignant). The following indices were obtained. the peak and average SUV (pSUV, aSUV) of lesions, tumor-to-background ratio acquired at images of 51 min p.i. ($TBR_{51}$), tumor-to-background ratio of areas under time-activity curves ($TBR_{area}$) and the ratio between the activities of tumor ROI at 51 min p. i. and at the time which background ROI reaches maximum activity on the time-activity curves ($T_{51}/T_{max}$). The pSUV, aSUV, $TBR_{51}$, and $TBR_{area}$ in malignant lesions were significantly higher than those in benign lesions. We set the cut-off values of pSUV, aSUV, $TBR_{51},\;TBR_{area}$ and $T_{51}/T_{max}$ for the differentiation of benign and malignant lesions at 3.5, 2.8, 5.1, 4.3 and 1.55, respectively. The sensitivity, specificity and accuracy were 91.7%, 80.0%, 84.4% by pSUV and aSUV, 83.3%, 85.0%, 84.4% by $TBR_{51}$, 83.3%, 100%, 93.8% by $TBR_{area}$ and 66.7%, 70.0%, 68.8% by $T_{51}/T_{max}$. The time-activity curves did not give additional information compared to SUV or TBR. The one false negative was a case with low-grade fibrosarcoma and all four false positives were cases with inflammatory change on histology. The visual, analysis of FDG-PET also detected the metastatic lesions in malignant cases with comparable accuracy In conclusion, all pSUV, aSUV, $TBR_{51}$, and $TBR_{area}$ are useful metabolic semi-quantitative indices with good accuracy for the differentiation of benign from malignant soft-tissue lesions.

  • PDF

Improved Clinical Staging of Esophageal Cancer with FDG-PET (양전자단층촬영술을 이용한 식도암의 병기 결정 성적 향상)

  • Kim, Young-Hwan;Choi, Joon-Young;Lee, Kyug-Soo;Choi, Yong-Soo;Lee, Eun-Jeong;Chung, Hyun-Woo;Lee, Su-Jin;Lee, Kyung-Han;Shim, Young-Mog;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.282-287
    • /
    • 2004
  • Purpose: Since preoperative staging in esophageal cancer is important in both therapy and prognosis, there had been many efforts to improve its accuracy. Recent studies indicate that whole body FDG-PET has high sensitivity in detection of metastasis in esophageal cancer. Therefore, we added FDG-PET to other conventional methods in staging esophageal cancer to evaluate the usefulness of this method. Materials & Methods: Subjects were 142 esophageal cancer patients (average $62.3{\pm}8.3$ yrs) who received CT and PET just before operation. First, we compared N stage and M stage of the CT or PET with those of the post-operative results. Then we compared the stage according to the EUS (T stage) and CT (N and M stage) or SUS (T stage) and CT & PET (N and M stage) to that according to the post-operative results. Results: Among 142 patients, surgical staging of 69 were N0 and 73 were N1. In M staging, 128 were M0 and 14 were M1. Sensitivity, specificity, and accuracy of N staging were 35.6%, 89.9%, 62.0% with CT and 58.9%, 71.0%, 64.7% with PET, respectively. In M staging, 14.3%, 96.9%, 88.7% with CT and 50.0%, 94.5%, 90.1%, with PET, respectively. The concordances of [EUS+CT] and [EUS+CT+PET] with post-operative results were 41.2% and 54.6%, respectively and there was significant improvement of staging with additional PET scan (p<0.005). Conclusion: The concordance of [EUS+CT+PET] with post-operative result was significantly increased compared to that of [EUS+CT]. Thus, the addition of FDG-PET with other conventional methods may enable more accurate preoperative staging.

Comparison of Thallium-201 Scan and Tc-99m Sestamibi Scan in the Differential Diagnosis of Breast Mass (유방암 진단에 있어서 탈륨스캔과 Tc-99m MIBI 스캔의 비교)

  • Cho, Ihn-Ho;Won, Kyu-Jang;Lee, Hyung-Woo;Lee, Soo-Jung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.76-83
    • /
    • 1999
  • Purpose: We performed this study to compare T1-201 and Tc-99m MIBI scans for the differentiation of malignant from benign breast mass. Materials and Methods: Thirty-eight female patients underwent T1-201 breast scan and thirty-two of them also underwent Tc-99m MIBI scan of the breast. After intravenous injection of 74-111 MBq of T1-201, early (10 minutes) and delayed (3 hours) images were obtained. Then, 555-740 MBq of Tc-99m MIBI was injected and images after 30 minutes were obtained. We compared T1-201 and Tc-99m MIBI scans with pathologic results. Results: Twenty-three patients were confirmed to have infiltrating duct carcinoma and fifteen patients to have benign breast mass by excisonal biopsy. The sensitivity of early and delayed T1-201 scan and Tc-99m MIBI scan in the detection of malignant breast lesion were 100% (23/23), 82% (18/22), and 90% (18120), respectively. The sensitivity of early T1-201 scan was significantly higher than that of delayed T1-201 scan (p<0.05). The specificity of early and delayed T1-201 scan and Tc-99m MIBI scan were 73% (l1/15), 73% (l1/15) and 83% (10/12), respectively (p: not significant). Three patients out of nine with fibroadenoma and one patient with atypical duct hyperplasia were false positive in both early and delayed T1-201 scans. The size of fibroadenoma with false positive in early and delayed T1-201 scan (4 cases) was larger than that of 11 fibroadenoma with true negative scan (p<0.01). Metastatic axillary lymph node involvement was present in fifteen patients. The sensitivity to detect metastatic nodes was 38% (5/13) for early T1-201 images, 15% (2/13) for delayed T1-201 images, 58% (7/12) for Tc-99m MIBI planar images and 67% (4/6) for Tc-99m MIBI SPECT. The sensitivity of Tc-99m MIBI planar or SPECT was significantly higher than that of delayed T1-201 images (p<0.05). Conclusion: Early T1-201 and Tc-99m MIBI scan are useful noninvasive methods to differentiate malignant from benign mass of breast Tc-99m MIBI scan was sensitive in detecting axillary lymph node metastasis in patients with breast cancer.

  • PDF

Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT (심근관류 SPECT에서 가역적인 병변을 보인 환자의 3차원 심장 SPECT/CTA 퓨전영상의 유용성)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Kang, Won-Jun;Kim, Seong-Min;Won, Kyoung-Sook;Lim, Seok-Tae;Hwang, Kyung-Hoon;Lee, Byeong-Il;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.513-518
    • /
    • 2009
  • Purpose: Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Materials and Methods: Forty-eight patients (M:F=26:22, Age: $63.3{\pm}10.4$ years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Results: Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Conclusion: Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

Usefulness of F-18 FDG PET/CT in Staging of Peripheral T Cell Lymphoma (말초성 T 세포 림프종의 병기 설정시 F-18 FDG PET/CT의 유용성)

  • Kang, Yun-Hee;Lim, Seok-Tae;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee;Yim, Chang-Yeol
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.369-374
    • /
    • 2008
  • Purpose: F-18 FDG PET/CT has excellent sensitivity and specificity for staging non-Hodgkin lymphomas, but to the author's knowledge few studies to date have evaluated FDG PET/CT in peripheral T cell lymphoma. We evaluated the usefulness of F-18 FDG PET/CT in staging of patients with peripheral T cell lymphoma, especially indolent cutaneous T cell lymphomas. Materials and Methods: Twenty five patients (M:F=17:8, age $53.7{\pm}14.8$ yrs) with biopsy-proven indolent cutaneous T cell (CL) or noncutaneous T cell lymphomas (NCL) underwent PET/CT scans for staging at baseline. Peak standardized uptake values (p-SUV) of all abnormal foci were measured and compared between cutaneous and noncutaneous lesions. F-18 FDG PET/CT was performed on 6 patients with indolent CL and on 19 patients with NCL. Results: All 6 patients with indolent CL had no significant FDG avidity in the skin despite histologically positive cutaneous lesions. However, FDG avidity appeared in extracutaneous lesions (lymph nodes) in two patients with CL where CT imaging suggested lymphoma involvement (mean p-SUV $4.26{\pm}0.37$ in noncutaneous lesions in CL). In NCL, FDG avidity was demonstrated in all lesions where CT imaging suggested lymphoma involvement (mean p-SUV, $8.52{\pm}5.00$ in noncutaneous lesions in NCL). Conclusion: F-18 FDG PET/CT has the limitation of usefulness for the evaluation of the skin in indolent CL. In contrast, F-18 FDG PET/CT is sensitive in staging evaluation of extracutaneous lesions regardless of CL or NCL.

Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPET in Coronary Artery Disease (관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jeong-Sun;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.354-361
    • /
    • 2008
  • Purpose: N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Materials and Methods: Seventeen patients (male 13 : $63{\pm}11$ years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Results: Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/89% vs MPS: 65%/82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversibile by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Conclusion: Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability.

Usefulness of Prone Position on PET-CT in Breast Cancer (유방암 PET-CT 검사에서 Prone(복와위)자세의 유용성 평가)

  • Park, Hoon-Hee;Kim, Sei-Yung;Kim, Jung-Yul;Park, Min-Soo;Lim, Han-Snag;Jung, Suk;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho;Lee, Yung-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.44-48
    • /
    • 2008
  • Purpose: In FDG-PET/CT of breast cancer, a sensitivity was 80~96% and a specificity was 75~95% commonly. It was valuable to identify a cancer in early stage been difficult in Mammography. Most of the PET/CT scans have been examined on supine position, so, the image of breast has been acquired by reconstructed whole body scan image. However, using prone position with a compensator, a shape of breast was reassembly shown to be real by gravity. Therefore, the purpose of this study was to evaluate diagnostic value of prone position in FDG PET-CT of breast cancer. Materials and Methods: 30 female patients with doubtful or positive breast cancer were examined. The PET-CT whole body scan was acquired at 60 minutes after $^{18}F$-FDG injection on Supine position. Then, regional breast spot scan was progressed on prone position using a compensator. Each image was evaluated by physicians blinded to patient's data, and statistical analysis did through SUVs measured in PET-CT images. Results: In 27 of 30 patients, prone position was shown accurate discrimination and diagnostic value, but in another 3 patients had a lesion 1cm below, PET-CT couldn't detect it, unlike MRI. Consequently, prone position distinguished a lesion better than Supine position, because of low degree of metamorphosis by gravity. The SUVs analysis of each position was significant (p value=0.004). Conclusion: In PET-CT of breast cancer, prone position could detect micrometastasis as well as primary lesion, better than supine position. Therefore, this study proposes that any technical change considered morphological feature like prone position can offer adequate and useful diagnostic information, together with complementary quantitative analysis.

  • PDF

Development of Rapid Analytical Method of Forbidden Medicines in Dietary Supplements Using LC-ESI-Tandem MS (LC-ESI-tandem MS를 이용한 기능성표방식품 중 부정유해물질 신속검사체계 개발)

  • Kim, Hee-Yun;Jang, Young-Mi;Joo, Hyun-Jin;Jung, Young-Hyun;Lee, Myoung-Sook;Park, Jong-Seok;Lee, Kwang-Ho;Lee, Hwa-Mi
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.372-379
    • /
    • 2007
  • A high-performance liquid chromatography-electrospray ionization (HPLC-ESI) tandem MS was developed for the rapid and simultaneous determination of forbidden medicines in dietary supplements. Thirteen medicinal components such as PDE-5 inhibitors and their analogues, and the newly identified dimethylsildenafil and xanthoanthrafil, were included in this study. After tentative standardization of molecular ions in both polarities using thirteen references on the mass spectrometer, with ESI-continuous infusion via the syringe pump method, the relative intensity of the ions present in the resulting spectra was quantitatively compared. From the results, the ion mode was selected depending on each reference's characteristics. A HPLC method coupled with the ESI mode was developed considering the matrix effect and interference depending on the type of sample. The validation test of the developed method was followed by carrying out precision, accuracy, recovery, sensitivity and linearity, etc. The method showed sufficiently high sensitivity, reproducibility, and specificity, and produced 4 times faster results when compared with the existing HPLC/UV method for the determination of forbidden compounds in dietary supplements.

Clinical Significance of Follow-up CT after Ultrasonography for Acute Appendicitis in Children (소아 급성 충수염에서 복부초음파 이후 전산화단층촬영 추적 검사의 임상적 의의)

  • Yu, Seong-Keun;Moon, Jin-Soo;Kim, Nam-Hee;Hwang, Jong-Hee;Nam, Seung-Yeon;Kim, Dong-Wook;Lee, Chong-Guk;Seo, Jung-Wook;Heo, Tae-Gil
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.10 no.1
    • /
    • pp.36-43
    • /
    • 2007
  • Purpose: The ultrasonography (USG) and computed tomography (CT) are popular diagnostic tools for the diagnosis of acute appendicitis in children, but there are many debates about their clinical significance. The purpose of this study is to clarify the clinical significance of USG, CT and follow-up CT performed subsequently to USG, especially in perforated acute appendicitis in children. Methods: We have reviewed 419 cases of surgically confirmed acute appendicitis in children under the age of sixteen, who had been treated in Inje University Ilsan Paik Hospital from March 2002 to February 2006. All the clinical data including the results of USG and CT were collected and analyzed. Results: Sensitivity, specificity, positive and negative predictive values of USG were 98.7%, 96.8%, 98.1%, 97.8% in non-perforation group and 90.8%, 100%, 100%, 81.9% in perforation group. Those of CT were 96.4%, 100%, 100%, 96.5% and 86.6%, 100%, 100%, 87.5% respectively. Those of follow-up CT after USG were 100%, 100%, 100%, 100% and 87.5%, 100%, 100%, 92.0% respectively. The duration of using antibiotics in seven patients showed positive correlation with the interval between two imaging studies (r=0.0472, p=0.019). There was no statistical significance of correlation when these imaging studies performed within 30 hours together. Conclusion: In most of the cases, single choice between USG and CT would be enough to diagnose the acute appendicitis in children. But, it may be helpful to perform CT as early as possible subsequently to USG when there is discrepancy between initial USG and clinical impression.

  • PDF