• Title/Summary/Keyword: specific energy curves

Search Result 44, Processing Time 0.028 seconds

EFFECTIVE REINFORCEMENT OF S-SHAPED FRONT FRAME WITH A CLOSED-HAT SECTION MEMBER FOR FRONTAL IMPACT USING HOMOGENIZATION METHOD

  • CHO Y.-B.;SUH M.-W.;SIN H.-C.
    • International Journal of Automotive Technology
    • /
    • v.6 no.6
    • /
    • pp.643-655
    • /
    • 2005
  • The frontal crash optimization of S-shaped closed-hat section member using the homogenization method, design of experiment (DOE) and response surface method (RSM) was studied. The optimization to effectively absorb more crash energy was studied to introduce the reinforcement design. The main focus of design was to decide the optimum size and thickness of reinforcement. In this study, the location of reinforcement was decided by homogenization method. Also, the effective size and thickness of reinforcements was studied by design of experiments and response surface method. The effects of various impact velocity for reinforcement design were researched. The high impact velocity reinforcement design showed to absorb the more crash energy than low velocities design. The effect of size and thickness of reinforcement was studied and the sensitivity of size and thickness was different according to base thickness of model. The optimum size and thickness of the reinforcement has shown a direct proportion to the thickness of base model. Also, the thicker the base model was, the effect of optimization using reinforcement was the bigger. The trend curve for effective size and thickness of reinforcement using response surface method was obtained. The predicted size and thickness of reinforcement by RSM were compared with results of DOE. The results of a specific dynamic mean crushing loads for the predicted design by RSM were shown the small difference with the predicted results by RSM and DOE. These trend curves can be used as a basic guideline to find the optimum reinforcement design for S-shaped member.

Study on the Axial Crushing Behaviors of UD Kevlar/Epoxy and Carbon-Kevlar/Epoxy Composite Tubes (단방향 케블라/에폭시, 탄소-케블라/에폭시 복합재 튜브의 축방향 압괴 거동에 대한 연구)

  • Kim, Hyung-Uk;Kim, Jung-Seok;Jung, Hyun-Seung;Yoon, Hyuk-Jin;Kwon, Tae-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.3
    • /
    • pp.271-277
    • /
    • 2010
  • In this paper, a numerical model for a Kevlar/Epoxy and Carbon-Kevlar/Epoxy tube used as an energy absorbing component has been developed and then results have been verified through experiment. The 2D shell element and Chang-Chang failure criterion of LS-DYNA that is commercial explicit FE code was used. Mechanical material properties for the model were obtained by material testing in advance. The numerical results were compared with quasi-static test results under axial compressive loading at 10mm/min. From the results, in the case of the Kevlar/Epoxy tube, load-crushed displacement curves were very close to the experiments and SEA (specific energy absorption) shows a good agreement with experimental one within less than 6%. However, the Carbon-Kevlar/Epoxy tube shows some differences with the experimental results.

Adsorption of Heavy Metal Cations by Fe and Al Hydroxides (철, 알루미늄 수산화물에 의한 중금속 Ion의 흡착)

  • Lee, Jyung-Jae;Chang, Sang-Moon;Choi, Jyung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.28 no.2
    • /
    • pp.105-113
    • /
    • 1995
  • Adsorption experiments of heavy metal cations by Fe- and Al-hydroxides was conducted to obtain clear information on their adsorption mechanisms. The adsorption isothermal curves of heavy metal cations by Fe- and Al-hydroxides conformed to Langmuir's equation. Increasing the crystallinity degree of Fe- and Al-hydroxides tended to decrease the adsorption capacity and binding energy of heavy metal cations. At the same crystallinity degree, Al-hydroxide showed higher adsorption capacity and energy for the heavy metal cations than Fe-hydroxide. The adsorption capacity and energy of heavy metal cations were directly related to CEC, specific surface area and charge density of hydroxides, and the sequence was in the order of $Cu^{+{+}}$ > $Zn^{+{+}}$ > $Cd^{+{+}}$. The adsorption mechanism of $M^{+{+}}$ form of heavy metal could be presumed as the specific adsorption of $M^{+{+}}$ and the desorption of two $H^+$ from the surface aquo($OH_2$) and/or hydroxo(-OH) group for each mole of $M^{+{+}}$ adsorbed. A ring structure between $M^{+{+}}$ and two surface aquo and/or hydroxo groups was postulated. Nonspecific adsorption involved the adsorption of $MCl^+$ and the desorption of one H+ from the surface aquo and/or hydroxo groups for each mole of $M^{+{+}}$ adsorbed. A single bond structure in which $MCl^+$ replaced one $H^+$ from the surface aquo and/or hydroxo groups was postulated. The ratio of specific to nonspecific adsorption increased with increasing pH.

  • PDF

Identification of Irradiated Food Additives by Photostimulated Luminescence (PSL) Method (Photostimulated Luminescence (PSL) 방법에 의한 국내 유통 분말형 식품가공원료의 방사선 조사 여부 모니터링)

  • Yun, Hyejeong;Hur, Jungmu;Yang, Suhyung;Lee, Byoung-Hun;Kwon, Joong-Ho;Kim, Dongho
    • Journal of Radiation Industry
    • /
    • v.2 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • Photostimulated luminescence (PSL), electron spin resonance (ESR) and thermoluminescence (TL) analyses were conducted to detect whether 258 kinds of extracted and powdered forms food additives were irradiated or not. In a view of the PSL results, 9 kinds of the extracted and powdered samples (3.2%) showed over 5,000 photon counts $(60sec)^{-1}$ and these samples were judged to be irradiation-positive. Thirty nine kinds of the samples (15.6%) yielded 700~5,000 photon counts $(60sec)^{-1}$ and these samples were grouped into irradiation-potential, while the samples showed below 700 photon counts $(60sec)^{-1}$ sec were judged to be irradiation-negative. TL glow curves for minerals separated from 5 samples were detected at $150^{\circ}C$ with high intensity. However, TL analysis did not apply to other irradiation-positive and irradiation-potential samples because the minerals for TL detection were not separated from the samples. ESR measurements for irradiation-positive and irradiation-potential samples, judged by PSL detection, showed no specific signals to irradiation. The results indicated that PSL could be applied to identify irradiation treatment of extracted and powdered food additives, while TL was optional and ESR was not suitable for detection extracted and powdered food additives.

Study on Axial Crushing Behaviors of UD Kevlar/Epoxy with Different Trigger Models (트리거 모델에 따른 일방향 케블라/에폭시 복합재 튜브의 축방향 압괴 거동 연구)

  • Kim, Hyung-Uk;Kim, Jung-Seok;Jung, Hyun-Seung;Yoon, Hyuk-Jin;Kwon, Tae-Soo
    • Composites Research
    • /
    • v.23 no.4
    • /
    • pp.28-34
    • /
    • 2010
  • In this paper, in order to develop a realistic trigger model for a unidirectional Kevlar/Epoxy tube, the numerical model has been established and then verified by comparison with the experimental result. To achieve this goal, four different trigger models were candidated and evaluated using the commercial explicit FE code LS-DYNA. In the finite element analysis, the 2D shell element and Chang-Chang failure criterion was used. Mechanical material properties for the model were obtained by material testing in advance. The numerical results were compared with quasi-static test results under axial compressive loading at 10mm/min. The load-crushed displacement curves were very close to the experiments and SEA (specific energy absorption) showed a good agreement with experimental one within less than 5%.

Investigation of Fatigue Damage of the Mooring Lines for Submerged Floating Tunnels Under Irregular Waves (불규칙 파랑 중 해중 터널 계류선의 단기 피로 손상 분석)

  • Kim, Seungjun;Won, Deok Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.1
    • /
    • pp.49-60
    • /
    • 2017
  • As well as the strength check, fatigue life check is also mainly required for designing mooring lines of the floating structures. In general, forces which induce dynamic structural response significantly affect to fatigue design of the mooring lines. So, waves are mainly considered as the governing loading for fatigue design of the mooring lines. In this study, characteristics of the fatigue damage of the mooring lines for submerged floating tunnels (SFT) under irregular waves are investigated. For this study time domain hydrodynamic analysis is used to obtain motion of the tunnel and tension and stresses of the mooring lines under the specific environmental conditions. Also, the Rainflow-counting method, the Palmgren-Miner's rule, and S-N curves for floating offshore structures presented by DNV recommendation is applied to calculate the fatigue damage due to the fluctuating stresses. Referring to the design plactice of the tendon pipes for TLP (tension-leg platform), which is very similar structural system to SFT, it is assumed that a 100 year return period wave attacks the SFT systems during 48 hours and the fatigue damages due to the environmental loading are calculated. Following the analysis sequence, the effects of the tunnel draft, spacing and initial inclination angle of the mooring lines on the fatigue damage under the specific environmental loadings are investigated.

Identification of Bulgogi Sauce Added with Low Quantity of Electron Beam-Irradiated Garlic Powders by Thermoluminescence Analysis: An Inter-Laboratory Study (전자선 조사 처리한 마늘분말 첨가 불고기소스의 혼합비와 살균처리에 따른 열발광 판별특성: 실험실 교차 검증시험)

  • Ahn, Jae-Jun;Lee, Jeongeun;Baek, Ji-Yeong;Jeong, Il-Yun;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.11
    • /
    • pp.1857-1863
    • /
    • 2013
  • Bulgogi sauces containing electron beam-irradiated garlic powder (1%, 3%, and 5%) were used to compare their irradiation status before and after pasteurization ($85^{\circ}C$, 30 min), using a thermoluminescence (TL) analysis by two different laboratories. The sauces with non-irradiated ingredient only provided a background TL glow curve with a maximum peak after $300^{\circ}C$. However, the presence of irradiated ingredient (1 and 10 kGy) was evident through the typical TL glow curves in a temperature range of 150 to $250^{\circ}C$. The concentration of irradiated ingredients showed a greater impact on identification characteristics than their radiation doses. TL ratios ($TL_1/TL_2$) were not able to confirm the results showing evidence of irradiation through the TL glow curve shapes. Pasteurization showed a negligible effect on the key identification parameters and did not change the shape or temperature range of radiation-specific TL glow peak, but reduced TL glow curve intensity. TL glow curve shape with the maximum peak in a temperature range of $150{\sim}250^{\circ}C$ was the most useful characteristic providing information required for confirming the irradiation status.

A Study on Flame Extinction in Oxymethane Combustion (메탄 산소 연소에 있어서 화염 소화에 대한 연구)

  • Kim, Tae Hyung;Kwon, Oh Boong;Park, Jeong;Keel, Sang-In;Yun, Jin-Han;Park, Jong Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.4
    • /
    • pp.34-41
    • /
    • 2015
  • Oxy-methane nonpremixed flames diluted with $CO_2$ were investigated to clarify impact of radiation heat loss and chemical effects of additional $CO_2$ to oxidizer stream on flame extinction. Flame stability maps were presented with functional dependencies of critical diluents mole fraction upon global strain rate at several oxidizer stream temperatures in $CH_4-O_2/N_2$, $CH_4-O_2/CO_2$, and $CH_4-O_2/CO_2/N_2$ counterflow flames. The effects of radiation heat loss on the critical diluent mole fractions for flame extinction are not significant even at low strain rate in nonpremixed $CH_4-O_2/N_2$ diffusion flame, whereas those are significant at low strain rate and are negligible at high strain rate (> $200s^{-1}$) in $CH_4-O_2/CO_2$ and $CH_4-O_2/CO_2/N_2$ counterflow flames. Chemical effects of additional $CO_2$ to oxidizer stream on the flame extinction curves were appreciable in both $CH_4-O_2/CO_2$ and $CH_4-O_2/CO_2/N_2$ flames. A scaling analysis based on asymptotic solution of stretched flame extinction was applied. A specific radical index, which could reflect the OH population in main reaction zone via controlling the mixture composition in the oxidizer stream, was identified to quantify the chemical kinetic contribution to flame extinction. A good correlation of predicted extinction limits to those calculated numerically were obtained via the ratio between radical indices and oxidizer Lewis numbers for the target and baseline flames. This offered an effective approach to estimate extinction strain rate of nonpremixed oxy-methane flames permitting air infiltration when the baseline flame was taken to nonpremixed $CH_4-O_2/N_2$ flame.

Energy Budgets for the Developmental Stages of Palaemon macrodactylus (Palaemon macrodactylus의 생활사에 따른 에너지 수지)

  • CHIN Pyung;KIM Heung-Yun;SIN Yun-Kyong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.5
    • /
    • pp.341-358
    • /
    • 1992
  • In order to estimate energy budgets of Palaemon macrodactylus, larvae of the shrimp were reared in the laboratory at constant conditions $(25^{\circ}C: 31-32\%o),$ and then juvenile to adult of the shrimp were reared at $15^{\circ}C\;and\;25^{\circ}C$ in the laboratory. Energy used by the reared shrimps were calculated from estimates of data on feeding, growth, molting, metabolism, nitrogen excretion, and energy content. Juveniles and adults reared in the laboratory, which fed on Artemia nauplii, had an average daily growth rates of 0.079 mm/day at $15^{\circ}C\;and\;of\;0.122mm/day\;at\;25^{\circ}C$. The average growth factor* of P. macrodactylus males and females ranged from $3.2\%$ for adult to $13.2\%$ for juveniles individuals, respectively. Intermolt periods were related to body size of the shrimp and to temperature. Average laboratory growth curves were calculated from data on growth factors and intermolt periods to body size of the shrimp at $15^{\circ}C\;and\;25^{\circ}C$. The calorie contents of the shrimp, their molts, eggs and larvae were determined by biochemical composition and oxygen bomb calorimetry. The average amount of energy used in growth for larvae and juvenile to adult were 4.94 cal and 4.55 cal per dry weight in milligram, respectively. The ammount of oxygen used in metabolism was calculated from size, temperature-specific respiration rate. To convert the ammount of oxygen used in respiration into the equivalent energy lost heat was estimated from the data on chemical composition for the larvae and adult, the values was 4.58 cal/ml $O_2$. The energy content per egg was 0.078 cal. The assimilation efficiency estimated by nitrogen content of food and egested faeces gave $61.5\%$ for the larvae. The efficiencies for juvenile to adult ranged between $79.4\%$ and $90.1\%$ The gross growth efficiencies $(K_1)$ and net growth efficiencies $(K_2)$ of P macrodactylus showed $18.33\%\;and 32.63\%$ for total larval stages, ranged from $21.30\%\;to\;31.04\%\;and\;from\;30.03\%\;to\;39.34\%$ for juvenile to adult, respectively.

  • PDF

An Experimental Study on Explosion Hazard of Dry Cleaning Solvent Recovery Machine in Laundry (세탁소 유기용제 회수건조기의 폭발 위험성에 관한 실험적 연구)

  • Choi, Jung-Min;Son, Bong-Se;Kim, Dong-Suk
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.39-45
    • /
    • 2013
  • This study analyzes the explosion hazard of dry cleaning solvent recovery machine in laundry shop in two aspects, i.e. combustible and ignition source, and determines the explosive conditions of this machine by conducting mockup explosion tests repeatedly, varying conditions and using real dry cleaning solvent recovery machines. As to combustibles, two kinds of combustibles used widely in Korea have been selected and tested. The flash points, LEL's, and saturation vapor pressures of those combustibles have been measured, and their explosion specific curves have been drawn, based on the results of the measurements, so that the explosion risks of those materials may be determined, depending on the temperatures. Potential voltages generated from materials for laundry and foreign materials of metals have been assumed to be the ignition sources in this application, and their potential voltages have been measured, depending on temperature, humidity, and antistatic agent, by using real materials for laundry and a potential voltage measuring device. Tests have been conducted, varying the quantities, concentrations, and operating temperatures of materials for laundry. As a result, explosions have not been generated with potential voltages of materials for laundry, but explosions have been observed when applying artificial spark energy of 2.0 mJ.