• Title/Summary/Keyword: specific discharge

Search Result 608, Processing Time 0.029 seconds

Phosphorus and Suspended Solid Loading in Lake Yongdam (용담호 소유역별 인 및 부유물질 유입부하량 산정)

  • Kwon, Sang-Yong;Kim, Young-Geel;Yih, Won-Ho;Kim, Bom-Chul;Heo, Woo-Myung
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.3 s.113
    • /
    • pp.322-333
    • /
    • 2005
  • Total phosphorus (TP) and suspended solids (SS) were measured in the discharge waters from 5 drainage basins of Lake Yongdam, from April, 2002 till March, 2004. The responses of SS and TP to rainfall were analyzed and their loadings into Lake Yongdam were calculated. The inflowing rivers into Lake Yongdam were the Juja River, the Jeongja River, the Jinan River, the Geum River and the Guryang River. Among these rivers Jinan River showed the highest TP that fluctuated very much according to the flow rate. TP and the flow rates (Q) of each river showed positive correlations with empirical relationsip of $TP\;=\;6.32Q^{0.30}$ for the Juia River, $TP\;=\;8.58Q^{0.49}$ for the Jeongia River, $TP\;=\;307.92Q^{0.10}$, for the Jinan River, $TP\;=\;17.91Q^{0.47}$, for the Geum River, $TP\;=\;20.11Q^{0.53}$ for Guryang River. In April 2002 ${\sim}$ March 2003, phosphorus loadings from the Juja River, the Jeongja River, the Jinan River, the Geum River and the Guryang River were calculated to be 3,677, 11,430, 36,412, 89,651, and 42,226 kgP ${\cdot}$ $yr^{-1}$ respectively. And the specific loadings from the Juja River, the Jeongia River, the Jinan River, the Geum River and the Guryang River were calculated to be 0.3, 2.9, 13.6, 9.3, and 13.0 kgP ${\cdot}$ $km^{-2}$ ${\cdot}$ $yr^{-1}$ respectively. In April 2002 ${\sim}$ March 2004, the suspended particles loading from the Juja River, the Jeongia River, the Jinan River, the Geum River and the Guryang River were 673, 1,232, 4,232, 30,902, 80,202 ton ${\cdot}$ $yr^{-1}$ respectively. The Guryang River showed the largest contribution of SS loading.

Three Cases of Menopausal Hot Flush and Sweating Treated by Ascending Kidney Water and Descending Heart Fire (AKDH) Pharmacopuncture Treatment (약침을 이용한 수화조절법으로 호전된 갱년기 상열감 및 발한과다 환자 치험 3례)

  • Jo, Na-Young;Roh, Jeong-Du
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.28 no.2
    • /
    • pp.193-203
    • /
    • 2015
  • Objectives : The purpose of this study is to evaluate the clinical effects of ascending kidney water and descending heart fire pharmacopuncture treatment for hot flush and sweating. Methods : Ascending kidney water and descending heart fire pharmacopuncture is achieved by injecting pharmacopuncture on a specific acupoint to change from the state of water-fire disharmony to harmonious state. Hwangryunhaedok-tang (黃連解毒湯) pharmacopuncture is injected on both side Gyeonjeong (GB 21 ), Pungji (GB 20 ). Total 0.4 cc was injected by 0.1 cc each point. BUM (Bear’s gall bladder, ox bezoar and musk) pharmacopuncture is injected on both side Jeonjung (CV 17 ), Jungwan (CV 12 ), Gihae (CV 6 ). Total 0.15 cc was injected by 0.05 cc each point. Treatment was done daily. The method of evaluation are Hot Flush Score (HFS), VAS and sweating areas. Results : In case 1, after treatment hot flush score was reduced from 24 to 4 points. VAS scale was reduced from 7 to 2. It took about two weeks for the symptoms to decrease by half. Associated symptoms almost did not stay at discharge. In case 2, after treatment hot flush score was reduced from 28 to 2 points. VAS scale was reduced from 10 to 3. And emotional symptoms were reduced about 70%. In case 3, after treatment hot flush score was reduced from 8 to 1 points. VAS scale was reduced from 6 to 1. And headache and chest discomfort symptoms have disappeared. Conclusions : Ascending kidney water and descending heart fire pharmacopuncture treatment is effective for improve ascending kidney water and descending heart fire energy. Therefore, it will be used to alleviate hot flush and sweating.

Water quality prediction of inflow of the Yongdam Dam basin and its reservoir using SWAT and CE-QUAL-W2 models in series to climate change scenarios (SWAT 및 CE-QUAL-W2 모델을 연계 활용한 기후변화 시나리오에 따른 용담댐 유입수 및 호내 수질 변화 예측)

  • Park, Jongtae;Jang, Yujin;Seo, Dongil
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.10
    • /
    • pp.703-714
    • /
    • 2017
  • This paper analyzes the impact of two climate change scenarios on flow rate and water quality of the Yongdam Dam and its basin using CE-QUAL-W2 and SWAT, respectively. Under RCP 4.5 and RCP 8.5 scenarios by IPCC, simulations were performed for 2016~2095, and the results were rearranged into three separate periods; 2016~2035, 2036~2065 and 2066~2095. Also, the result of each year was divided as dry season (May~Oct) and wet season (Nov~Apr) to account for rainfall effect. For total simulation period, arithmetic average of flow rate and TSS (Total Suspended Solid) and TP (Total Phosphorus) were greater for RCP 4.5 than those of RCP 8.5, whereas TN (Total Nitrogen) showed contrary results. However, when averaged within three periods and rainfall conditions the tendencies were different from each other. As the scenarios went on, the number of rainfall days has decreased and the rainfall intensities have increased. These resulted in waste load discharge from the basin being decreased during the dry period and it being increased in the wet period. The results of SWAT model were used as boundary conditions of CE-QUAL-W2 model to predict water level and water quality changes in the Yongdam Dam. TSS and TP tend to increase during summer periods when rainfalls are higher, while TN shows the opposite pattern due to its weak absorption to particulate materials. Therefore, the climate change impact must be carefully analyzed when temporal and spatial conditions of study area are considered, and water quantity and water quality management alternatives must be case specific.

Nomogram of Transcutaneous Bilirubin Level after Birth Driven from a Single Center (단일기관에서 도출된 출생 후의 경피적 빌리루빈의 노모그램)

  • Han, Young-Ji;Kim, Eun-Ryoung;Lee, Myung-Sook;Lee, Won-Uk;Park, Su-Hwa;Lee, Jung-Ju
    • Neonatal Medicine
    • /
    • v.17 no.1
    • /
    • pp.102-108
    • /
    • 2010
  • Purpose : The goal of this study was to measure bilirubin levels over 6 hours using a transcutaneous bilirubinometer. The change in the bilirubin levels were recorded in anomogram. The natural progress of jaundice in neonates was monitored using the nomogram and cases were identified that needed further follow-up observation and treatment. Methods : The subjects of this study were 986 healthy term or near-term infants at the age of 35 weeks or older who were born at Sung-Ae General Hospital during the period from October 1, 2007 to April 30, 2009 and whose parents were both Koreans. Transcutaneous bilirubin measurements were obtained using a transcutaneous bilirubinometer (Minolta, JM-103) from 6 hours of life to discharge at intervals of 6 hours. A nomogram was derived from the obtained data and compared to the delivery method, gestational age, and feeding method. Results : Percentile graphs were drawn according to time. Based on the graphs, phototherapy was necessary in more than 90 percent of the infants between 35 and 37.6 weeks of age and in 95 percent of the infants 38 weeks and older. The mean bilirubin level at 24, 48, 72 and 96 hours after birth were compared according to the delivery method, gestational age, and feeding method. The bilirubin level in 48 hours was significantly higher in neonates born via cesarean section delivery compared to the neonates born via vaginal delivery, however the levels were not statistically different at the other hours. Conclusion : The results of this study show the nomogram derived from hour-specific transcutaneous bilirubin levels. This information can be used to predict the risk for subsequent significant hyperbilirubinemia.

Analysis and Design of Profiling Adaptor for XML based Energy Storage System (XML 기반의 에너지 저장용 프로파일 어댑터 분석 및 설계)

  • Woo, Yongje;Park, Jaehong;Kang, Mingoo;Kwon, Kiwon
    • Journal of Internet Computing and Services
    • /
    • v.16 no.5
    • /
    • pp.29-38
    • /
    • 2015
  • The Energy Storage System stores electricity for later use. This system can store electricity from legacy electric power systems or renewable energy systems into a battery device when demand is low. When there is high electricity demand, it uses the electricity previously stored and enables efficient energy usage and stable operation of the electric power system. It increases the energy usage efficiency, stabilizes the power supply system, and increases the utilization of renewable energy. The recent increase in the global interest for efficient energy consumption has increased the need for an energy storage system that can satisfy both the consumers' demand for stable power supply and the suppliers' demand for power demand normalization. In general, an energy storage system consists of a Power Conditioning System, a Battery Management System, a battery cell and peripheral devices. The specifications of the subsystems that form the energy storage system are manufacturer dependent. Since the core component interfaces are not standardized, there are difficulties in forming and operating the energy storage system. In this paper, the design of the profile structure for energy storage system and realization of private profiling system for energy storage system is presented. The profiling system accommodates diverse component settings that are manufacturer dependent and information needed for effective operation. The settings and operation information of various PCSs, BMSs, battery cells, and other peripheral device are analyzed to define profile specification and structure. A profile adapter software that can be applied to energy storage system is designed and implemented. The profiles for energy storage system generated by the profile authoring tool consist of a settings profile and operation profile. Setting profile consists of configuration information for energy device what composes energy saving system. To be more specific, setting profile has three parts of category as information for electric control module, sub system, and interface for communication between electric devices. Operation profile includes information in relation to the method in which controls Energy Storage system. The profiles are based on standard XML specification to accommodate future extensions. The profile system has been verified by applying it to an energy storage system and testing charge and discharge operations.

A Clinical Study of Hypersensitive rhinitis including Allergic rhinitis (알레르기성 비염을 포함하는 과민성 비염 환자에 관한 임상적 연구)

  • Choi, In-Hwa
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.15 no.2
    • /
    • pp.169-182
    • /
    • 2002
  • Background: Allergic rhinitis(AR) is a heterogeneous disorder that despite its high prevalence is often undiagnosed. It is characterized by one or more symptoms including sneezing, itching, nasal congestion, and rhinorrhea. And it is frequently accompanied by symptoms involving the eyes, ears, and throat, including postnasal drainage. There are many different causes of rhinitis in children and adults. Approximately 50$\%$ of all cases of rhinitis are caused by allergy. In the case of rhinitis caused by allergens, symptoms arise as a result of inflammation induced by a gamma globulin E-mediated immune response to specific allergens such as pollens, molds, animal dander, and dust mites. The immune response involves the release of inflammatory mediators and the activation and recruitment of cells to the nasal mucosa. AR is similar to 鼻?, hypersensitive rhinitis in Oriental Medicine. I think hypersensitive rhinitis is including of AR, vasomotor rhinitis and non-allergic rhinitis related with eosinophil increased and so on. Purpose: To perform a clinical analysis of hypersensitive rhinitis including allergic rhinitis and estimate the efficacy of Oriental Medical treatment. Objective: We studied 96 patients who had visited our hospital with complaints of nasal symptoms from March 2000 to February 2002; they had the signs more than 2 - nasal obstruction, watery discharge, sneezing and eye or nasal itching. Parameters Observed & Methods: We treated them with acupuncture & herb-medication. Sometime they used aroma oil or external medicine. 1) the distribution of sex & age groups 2) the clinical type based on duration & the severity of symptom 3) the breakdown of complication & pasl history of Otolaryngologic or allergic disease 4) the clinical assessment and classification of rhinitis(sneezers and runners & blockers) 5) the associated symptoms and signs 6) the classification of Byeonjeung 7) the classification of prescriptions and 8) the efficacy of treatment. Result: 1. In the clinical type of based on duration, the intermittent type was 42.7$\%$ and the persistent was 57.3$\%$. 2. We observed the severity of symptoms based on the quality of life. The mild type was 24.0$\%$ and the moderate-severe was 76.0$\%$. 3. In the clinical assessment and classification of rhinitis, the sneezers and runners type was 69.8$\%$ and the blockers was 30.2$\%$. 4. The most common family history with otolaryngologic or allergic disease were allergic rhinitis(17.7$\%$), urticaria, paranasal sinusitis and T.B.(3.1$\%$). 5. The most common past history with otolaryngologic or allergic disease were paranasal sinusitis(14.6$\%$), atopic dermatitis and asthma(8.3$\%$). It was 31.3$\%$ they had a family history and 44.8$\%$, past history. 6. The most common complication was paranasal sinusitis(15.6$\%$). In decreasing order the others were otitis media with effusion(9.4$\%$), GERD and headache(6.3$\%$), asthma, bronchitis, nasal bleeding and allergic dermatitis(5.2$\%$). 7. Classification through Byeonjeung : ⅰ) 39 cases(34.9$\%$) were classified as showing Deficiency syndrome. The insuffficiency of Qi was 17.7$\%$, deficiency of Kidney-Yang, 12.5$\%$ and Lung-Cold, 10.4$\%$. ⅱ) 57 cases(59.4$\%$) were classified as showing Excess syndrome. The Fever of YangMing-meridian was 35.4$\%$, Lung-Fever, 24.0$\%$. 8. The efficacy of treatments showed: an improvement in 22cases(22.9$\%$); an improvement partly in 24 cases(25.0$\%$); no real improvement or changes in 16 cases(16.7$\%$); and couldn't check the results 18cases(18.6$\%$). Conclusion: We suggest that this study could be utilized as a standard of clinical Oriental Medical treatment when we treat hypersensitive rhinitis including allergic rhinitis.

  • PDF

Observation of Ice Gradient in Cheonji, Baekdu Mountain Using Modified U-Net from Landsat -5/-7/-8 Images (Landsat 위성 영상으로부터 Modified U-Net을 이용한 백두산 천지 얼음변화도 관측)

  • Lee, Eu-Ru;Lee, Ha-Seong;Park, Sun-Cheon;Jung, Hyung-Sup
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_2
    • /
    • pp.1691-1707
    • /
    • 2022
  • Cheonji Lake, the caldera of Baekdu Mountain, located on the border of the Korean Peninsula and China, alternates between melting and freezing seasonally. There is a magma chamber beneath Cheonji, and variations in the magma chamber cause volcanic antecedents such as changes in the temperature and water pressure of hot spring water. Consequently, there is an abnormal region in Cheonji where ice melts quicker than in other areas, freezes late even during the freezing period, and has a high-temperature water surface. The abnormal area is a discharge region for hot spring water, and its ice gradient may be used to monitor volcanic activity. However, due to geographical, political and spatial issues, periodic observation of abnormal regions of Cheonji is limited. In this study, the degree of ice change in the optimal region was quantified using a Landsat -5/-7/-8 optical satellite image and a Modified U-Net regression model. From January 22, 1985 to December 8, 2020, the Visible and Near Infrared (VNIR) band of 83 Landsat images including anomalous regions was utilized. Using the relative spectral reflectance of water and ice in the VNIR band, unique data were generated for quantitative ice variability monitoring. To preserve as much information as possible from the visible and near-infrared bands, ice gradient was noticed by applying it to U-Net with two encoders, achieving good prediction accuracy with a Root Mean Square Error (RMSE) of 140 and a correlation value of 0.9968. Since the ice change value can be seen with high precision from Landsat images using Modified U-Net in the future may be utilized as one of the methods to monitor Baekdu Mountain's volcanic activity, and a more specific volcano monitoring system can be built.

Midterm Patency after Off-Pump Coronary Artery Bypass Grafting (심폐바이패스없이 심박동상태에서 시행한 관상동맥우회술후 중기 개통율)

  • Lee, Cheul;Chang, Woo-Ik;Lim, Cheong;Kim, Ki-Bong;Chae, In-Ho;Oh, Byung-Hee;Lee, Myoung-Mook;Park, Young-Bae
    • Journal of Chest Surgery
    • /
    • v.34 no.8
    • /
    • pp.583-590
    • /
    • 2001
  • The aim of this study was to compare one-year graft patency after coronary artery bypass grafting without cardiopulmonary bypass(OPCAB) with that of conventional CABG and that of on-pump beating CABG, and to demonstrate any differences in patency of various conduits among the three groups. Material and Method: We analyzed the results of OPCAB cases(group I; n=122) compared with those of conventional CABG cases(group II; n=65) and those of on-pump beating CABG cases(group III; n=19). In group I, coronary angiography(CAG) was performed immediately postoperatively and 1 year after surgery. In group II and III, CAG was performed 1 year after surgery. Graft patency was graded as grade A(excellent), grade B(fair), or grade O(occluded). Result: The average number of distal anastomoses in groups I, II, and II were 3.1$\pm$1.1, 3.7$\pm$0.9, and 3.6$\pm$0.9, respectively. In group I, postoperative CAG was performed in 92%(112/122) of patients before discharge. The patency rate(grade A+B) was 96.4$(162/168) for arterial grafts, and 85.6%(160/187) for saphenous vein grafts(SVG). One-year follow-up CAG was performed in 74%(90/122) of patients. The patency rate was 97.8%(132/135) for arterial grafts, and 67.9%(106/156) for SVG. In group II, one-year follow-up CAG was performed in 65%(42/65) of patients. The patency rate(grade A+B) was 93.5%(43/46) for arterial grafts, and 86.8%(33/38) for SVG. Conclusion: Our results demonstrated that the patency rate of SVG after OPCAB was significantly lower than that of arterial grafts in the early postoperative CAG(p<0.001), and was also significantly lower than those of SVG of group II(p<0.001) and group III(p<0.01) in the postoperative one-year CAG, although there was no significant difference is one-year patency of arterial grafts among the three groups. Our data suggest that a specific perioperative anticoagulant therapy may be advisable in patients undergoing OPCAB with SVG.

  • PDF