• Title/Summary/Keyword: source-skin distance

Search Result 29, Processing Time 0.027 seconds

A Study on Effective Source-Skin Distance using Phantom in Electron Beam Therapy

  • Kim, Min-Tae;Lee, Hae-Kag;Heo, Yeong-Cheol;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.15-19
    • /
    • 2014
  • In this study, for 6-20 MeV electron beam energy occurring in a linear accelerator, the authors attempted to investigate the relation between the effective source-skin distance and the relation between the radiation field and the effective source-skin distance. The equipment used included a 6-20 MeV electron beam from a linear accelerator, and the distance was measured by a ionization chamber targeting the solid phantom. The measurement method for the effective source-skin distance according to the size of the radiation field changes the source-skin distance (100, 105, 110, 115 cm) for the electron beam energy (6, 9, 12, 16, 20 MeV). The effective source-skin distance was measured using the method proposed by Faiz Khan, measuring the dose according to each radiation field ($6{\times}6$, $10{\times}10$, $15{\times}150$, $20{\times}20cm^2$) at the maximum dose depth (1.3, 2.05, 2.7, 2.45, 1.8 cm, respectively) of each energy. In addition, the effective source-skin distance when cut-out blocks ($6{\times}6$, $10{\times}10$, $15{\times}15cm^2$) were used and the effective source-skin distance when they were not used, was measured and compared. The research results showed that the effective source-skin distance was increased according to the increase of the radiation field at the same amount of energy. In addition, the minimum distance was 60.4 cm when the 6 MeV electron beams were used with $6{\times}6$ cut-out blocks and the maximum distance was 87.2 cm when the 6 MeV electron beams were used with $20{\times}20$ cut-out blocks; thus, the largest difference between both of these was 26.8 cm. When comparing the before and after the using the $6{\times}6$ cut-out block, the difference between both was 8.2 cm in 6 MeV electron beam energy and was 2.1 cm in 20 MeV. Thus, the results showed that the difference was reduced according to an increase in the energy. In addition, in the comparative experiments performed by changing the size of the cut-out block at 6 MeV, the results showed that the source-skin distance was 8.2 cm when the size of the cut-out block was $6{\times}6$, 2.5 cm when the size of the cut-out block was $10{\times}10$, and 21.4 cm when the size of the cut-out block $15{\times}15$. In conclusion, it is recommended that the actual measurement is used for each energy and radiation field in the clinical dose measurement and for the measurement of the effective source-skin distance using cut-out blocks.

Development of Multi-Purpose Variable Polarization Imaging System for Clinical Diagnosis (임상 진단용 다목적 가변 편광 영상장치 개발)

  • Bae, Young-Woo;Jung, Byung-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.265-270
    • /
    • 2007
  • Polarization imaging systems have been widely used to selectively characterize skin lesions. Nevertheless, current systems are used in single-mode due to the limitations of a fixed polarization mode and a single-working distance of light source, in which uniform light distribution is achieved on target area. To address such limitations, we developed a variable polarization imaging system based on multi-working distance of light source for various clinical diagnoses. In this study, we characterize the imaging system and present experiment results demonstrating its clinical usefulness. The imaging system consists of a CCD color camera, linear polarization filters, and a single-layered LED ring light source which provides uniform light distribution at multi-working distances. The first polarizer was placed on the light source and the second polarizer placed on objective lens provides continuous linear polarization angle from $0^{\circ}\;to\;90^{\circ}$. The clinical efficacy of the imaging system was investigated by acquiring and analyzing clinical images of skin wrinkle and dental plaque. With the experiments, we verified the potential usefulness of the imaging system for other clinical applications.

Penumbra Effect on Integral Absorbed Dose in Co-60 Teletherapy

  • Moon, Philip S.
    • Nuclear Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.87-93
    • /
    • 1973
  • Due to the Co-60 source size, the penumbra in Co-60 teletheraphy poses a serious problem, even if the extended collimators are used, Here an empirical formula for the calculation of integral absorbed dose in the penumbra region was derived. Through a numerical calculation, the penumbra effect on integral absorbed dose was investigated. The longer the source-to-skin distance, the larger the integral absorbed dose of penumbra region, and the larger the source diameter, the larger the integral absorbed dose of penumbra region. It was also found that in some case the integral absorbed dose in penumbra region becomes several times larger than the integral absorbed dose of treatment region itself if the source-to-skin distance becomes greater. Therefore, one must consider the penumbra effect in Co-60 teletherapy.

  • PDF

Research of 6MeV electron dose distribution (Electron therapy에서의 dose distribution에 관한 연구)

  • Je Jae Yong;Park Chul Woo;Jin Sung Jin;Park Eun Tae
    • 대한방사선치료학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.27-32
    • /
    • 2005
  • Electron is used for the treatment of skin cancer, breast cancer, and head and neck cancer in clinic. Our study is performed to check the isodose distribut ion in source surface distance(SSD) and source bolus distance(SBD) setup, nipple influence to isodose distribution of electron, junctional area isodose variation of photon and electron field. Dosimetry is carried out with phantom, acryl, and film as the same condition of treatment setup. $8\%$ of isodose difference is noted with the surface distance(SSD) and source bolus distance(SBD) setup. To reduce the influence of nipple. corresponding volume of bolus should be removed. And bolus covering all the electron field reduced hot and cold spot of junctional area of photon.

  • PDF

Principal Components of Thermal Stimulation while the Warm Needling: Diameter of the Acupuncture Needle and Distance from the Skin (온침 표준화를 위한 열자극 요소 연구: 침 두께 및 피부-뜸 거리를 중심으로)

  • Yang, Seung-Bum;Kwon, O Sang
    • Korean Journal of Acupuncture
    • /
    • v.36 no.4
    • /
    • pp.210-220
    • /
    • 2019
  • Objectives : Warm needling is a combined treatment technique of acupuncture and moxibustion. In this study, we aimed to find out the components related with the thermal stimulation of the warm needling and to provide basic data for the guideline of the warm needling technique in the clinic. Methods : In this study, we measured thermal change of 3% agarose phantom embedding K-type thermocouples in depths of 0, 1, 2, 4, 8 and 16 mm. The warm needling was performed with acupuncture needles of various specifications (0.50×30, 0.50×40, 0.30×30, 0.30×40, 0.20×30 and 0.20×40 mm). A linear regression analysis was performed to find out the major component and quantify the effectiveness of the thermal stimulation during warm needling. Results : As a result of the measurement of temperature change, we could observe the thermal change pattern from the surface of the phantom to the 16mm deep part of the phantom. The thermal pattern was similar among the needles of different specifications. The regression analysis pointed the distance between the moxa cautery and the skin surface as the main component for the thermal stimulation of the warm needling. Conclusions : The authors suggest considering the distance between moxa cautery and the skin rather than the diameter of the acupuncture needle in accordance to the result of the study.

The Physical Penumbra of the 6MV X-ray (6MV 방사선의 물리학적 Penumbra)

  • Cho Moon-June;Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.333-336
    • /
    • 1991
  • High energy Photon beam has a sharp beam margin due to a less side scatter and the other things. But there still remains a penumbra where the dose changes rapidly in the region near the edge of a radiation beam, although it is short in width. It is suggested that the width of the penumbra depends on the source size, distance from source to diaphragm, source to skin distance, and depth in tissue. However, it is also supposed that the other factors influence the penumbra width. In this paper, we investigate changes of the physical penumbra widths according to various field sizes and depths, by using the three dimensional dosimetry system. As a result, we found that as field size and depth increase, the physical penumbra width also increases.

  • PDF

A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries (복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구)

  • Jang, Ji-Sung;Choi, Weon-Keun;Jung, Jae-Yon;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF

Dose Effect of Tissue Compensator for 6 MV X-Ray (두경부 방사선조사시 3차원조직보상체에 의한 피부선량)

  • Lee, Ho-Jun;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.147-153
    • /
    • 1992
  • It is ideal thing to compensate tissue deficit without skin contamination in curvatured irradiation field of high energy photon beam. The 3-dimensional compensating technique utilizing tissue equivalent materials to ensure an adequate dose distribution and skin sparing effect was described. This compensator was made of paraffin ($70\%$) and stearin wax ($30\%$) compound. The parameters for evaluation of the effect on skin dose in application of compensator were considered in the size of the field, the thickness of the compensator and the source-to-axis distance. The results are as follows; the skin doses were not changed even though application of the compensator, but depended on the field size and the source-to-axis distance, and the skin doses were only slightly changed within $1\%$ relative errors as increasing the thickness of the compensator in these experiments.

  • PDF

The Study on the Laser in the Safety Device for Dangerous Machine (위험기계 방초장치에 적용되는 레이저에 관한 연구)

  • 이충렬;김창봉
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.3
    • /
    • pp.22-29
    • /
    • 2002
  • The safety device of infrared type for dangerous machine being used currently has a harmful effect on human's eye and skin. In this paper we explain about the characteristics of lasr source and analyze the amount of harmfulness on human's eye by simulation method. We used the datas given by ANSI in this simulation.

Non Darcy Mixed Convection Flow of Magnetic Fluid over a Permeable Stretching Sheet with Ohmic Dissipation

  • Zeeshan, A.;Majeed, A.
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.153-158
    • /
    • 2016
  • This paper aims to discuss the Non Darcy boundary layer flow of non-conducting viscous fluid with magnetic ferroparticles over a permeable linearly stretching surface with ohmic dissipation and mixed convective heat transfer. A magnetic dipole is applied "a" distance below the surface of stretching sheet. The governing equations are modeled. Similarity transformation is used to convert the system of partial differential equations to a system of non-linear but ordinary differential equations. The ODEs are solved numerically. The effects of sundry parameters on the flow properties like velocity, pressure, skin-friction coefficient and Nusselt number are presented. It is deduced the frictional resistance of Lorentz force decreases with stronger electric field and the trend reverses for temperature. Skin friction coefficient increase with increase in ferromagnetic interaction parameter. Whereas, Nusselt number decrease.