• Title/Summary/Keyword: source magnitude

Search Result 418, Processing Time 0.042 seconds

Validation on the Bodywave Magnitude Estimation of the 2017 DPRK's Nuclear Test by Source Scaling (지진원 상대비율 측정법을 이용한 2017년 북한 핵실험의 실체파 규모 검증)

  • Kim, Tae Sung
    • Economic and Environmental Geology
    • /
    • v.51 no.6
    • /
    • pp.589-593
    • /
    • 2018
  • Democratic Peoples' Republic of Korea (DPRK) conducted the $6^{th}$ underground nuclear test at the Punggye-ri underground nuclear test site on September 27, 2017 12 hours 30 minutes of Korean local time. Comprehensive Nuclear-Test Ban Treaty Organization (CTBTO) under U.N. announced the body wave magnitude of the event was mb 6.1 while U.S. Geological Survey (USGS)'s calculation was mb 6.3. In this study, the differences of the magnitude estimates were investigated and verified. For this purpose, a source scaling between the $5^{th}$ and $6^{th}$ event, which's epicenters are 200 meters apart, was performed using seismic data sets from 30 broadband stations. The relative amplitude variations of the $6^{th}$ event compared to the $5^{th}$ event in the frequency domain was analyzed through the scaling. The increased amount of the bodywave magnitude $m_b$ for the $6^{th}$ event was calculated at 1 Hz, which was compared to those from USGS and CTBTO's calculations.

Estimation of b-value for Earthquakes Data Recorded on KSRS (KSRS 관측자료에 의한 b-값 평가)

  • 신진수;강익범;김근영
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.28-34
    • /
    • 2002
  • The b-value in the magnitude-frequency relationship logN(m) = $\alpha$ - bmwhere N(m) is the number of earthquakes exceeding magnitude m, is important seismicity parameter In hazard analysis. Estimation of the b-value for earthquake data observed on KSRS array network is done employing the maximum likelihood technique. Assuming the whole Korea Peninsula as a single seismic source area, the b-value is computed at 0.9. The estimation for KMA earthquake data is also similar to that. Since estimate is a function of minimum magnitude, we can inspect the completeness of earthquake catalog in the fitting process of b-value. KSRS and KMA data lists are probably incomplete for magnitudes less than 2.0 and 3.0, respectively. Examples from probabilistic seismic hazard assessment calculated for a range of b-value show that the small change of b-value has seriously effect on the prediction of ground motion.

  • PDF

Evaluation of Popular Photometry Analysis Softwares Using DSLR Camera

  • Shim, Hyunjin
    • Journal of the Korean earth science society
    • /
    • v.38 no.5
    • /
    • pp.323-332
    • /
    • 2017
  • The Digital Single Lens Reflex (DSLR) camera combined with a small aperture telescope is an efficient equipment for an astronomy-related lab exercise. This paper compares the different photometry softwares to provide insights on using the GUI-based photometry tool to the conventional command-line based photometry tool. The magnitude of the same point source measured within the aperture is consistent regardless of the software used although the background estimation, partial pixel treatment, and error estimation are slightly different. In a crowded field image where the aperture photometry is less reliable, the aperture photometry with varying aperture size is useful to see the qualitative trend for the magnitude. Due to the variation in ISO settings and the color dependence on the RGB Bayer system, an initial uncertainty of ~0.15mag is expected to be embedded in the magnitude derived from the DSLR images.

Source Identification in an Interior Sound Field (반사파가 존재하는 실내 공간에서의 음원 탐지 방법)

  • 최영철;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1203-1209
    • /
    • 2001
  • Identification of noise sources, their locations and strengths, have been taken great attention. The method that can identify noise sources normally assumes that noise sources are located at a free field. However, the sound in a reverberant field consists of that coming directly from the source plus sound reflected or scattered by the walls or objects in the field. In contrast to the exterior sound field, reflections are added to sound field. Therefore, we have to consider the reverberation effect on the source identification method. The main objective of this paper is to identify noise source in the reverberant field. At fist, we try to identify noise sources in a rigid wall enclosure using the spherical beamforming method. In many case of practical interest, the wall has an admittance so that complex reflection process occurred. In this paper, we assumed the complex reverberant field in the enclosure to be the sum of plane waves with random incidence and magnitude. Then the effects of reverberant field at interior source identification have been studied theoretically as well as experimentally

  • PDF

Searching for Electromagnetic Counterpart of Gravitational Wave Source with KMTNet

  • Kim, Joonho;Im, Myungshin;Lee, Chung-Uk;Kim, Seung-Lee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.62.3-62.3
    • /
    • 2019
  • After first identification of electromagnetic counterpart of gravitational wave source (GW170817), era of multi-messenger astronomy has begun. For specifying coordinate, magnitude, and host galaxy information, optical follow-up observation of GW source becomes important. With following engineering run and O3 run of LIGO and VIRGO starting in March 2019, we present searching strategy for optical counterpart of GW source using KMTNet. 24 hours monitoring system and large field of view (4 square-degree) of KMTNet are advantage to discover a transient like GW event. By performing tiling observation of high probability area in GW localization map, we expect to observe early light-curve of GW optical counterpart. After identification, follow-up observation with various KMTNet bands and other telescopes like Gemini and UKIRT will also be performed. We will study collision mechanism, progenitor, and characteristics of host galaxy using observation data of GW source.

  • PDF

Utility Interactive Photovoltaic Generation System using PWM Current Source Inverter (PWM 전류형인버터를 이용한 계통연계형 태양광 발전시스템)

  • 박춘우;성낙규;이승환;강승욱;이훈구;한경희
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.109-112
    • /
    • 1996
  • In this paper, we composed utility interactive photovoltaic generation system of current source inverter, and controlled that low harmonic and high power factor are hold by supposing control and compensation method which is concerned with synchronous signal distortion and modulation delay. And we put parallel resonant circuit into dc link, so, magnitude of direct reactance was reduce by restraining direct current pulsation which had accumulation of pulsating power in alternating electrolytic condenser. Also we controlled that modulation factor is operated around maximum output of solar cell.

  • PDF

Effects of Circulating current on the controlled Circulating current Cycloconverter (순환전류제어형 싸이크로콘버터에서 순환전류의 영향)

  • Go, Seok-Jin;Lee, Kyu-Jong;Seong, Se-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.140-143
    • /
    • 1988
  • In this study, so called high frequency cycloconverter which converts commercial so power source directly to high frequency power source is proposed. In this system, the circulating current play very important role. Its state and magnitude effects on system characteristics. This paper deals with the control method of the circulating current and side band component analysis of high frequency side current which is produced by it.

  • PDF

A Study on the Characteristics of Electric Shock in Water due to the Leakage of Submerged Electric Facility (침수된 전기설비의 누전으로 인한 수중에서의 감전특성에 관한 연구)

  • 김두현;강동규
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.3
    • /
    • pp.61-65
    • /
    • 2002
  • A study on the characteristics of electric shock in fresh water due to the leakage of submerged electric facility is conducted by using a reduced scale model at a scale of 1:10 in laboratory. Electric potential as a function of distance from leakage source, type of the leakage source, magnitude of the source voltage, submerged depth and diameter of a copper rod electrode is measured. On the basis of safety standard, separation for guarantee of safety is determined by the measured potential. Also supposing that body resistance is 500[$\Omega$], the human reaction was estimated by calculating body current for some shock duration. Thus, in this paper, the hazard of the electric shock is assessed by introducing representative safety factors, body voltage and body current due to leakage source.

Development and Application of Measuring Method of Instantaneous Intensity (순시 인텐시티 측정 기법의 개발 및 응용)

  • 이장우;김영종;안병하;이운섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.560-563
    • /
    • 1997
  • Sound intensity method is well known as a visualization technique of sound field and sound propagation in noise control. Sound intensity is a vector quantity that describes the magnitude and the direction of net flow of acoustic energy at a given position. The current measuring method is expensive and difficult to identify the noise source exactly. In this paper, we have studied the noise source identification and the characteristics of noise source of rotary compressor for air conditioner using complex sound intensity method. The new method for instantaneous sound intensity is also proposed and it is useful for transient state and steady state. The criteria of these states select auto correlation coefficient. The advantage, simplicity and economic attribution of this method are verified by analyzing the characteristics of noise source with instantaneous sound intensity compared to mean sound intensity.

  • PDF

Development and Application of Measuring Method for Instantaneous Intensity (순시 인텐시티 측정 기법의 개발 및 응용)

  • 이장우;안병하
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.960-963
    • /
    • 2003
  • Sound intensity method is well known as a visualization technique of sound field and sound propagation in noise control. Sound intensity is a vector quantity that describes the magnitude and the direction of net flow of acoustic energy at a given position. The current measuring method is expensive and difficult to identify the noise source exactly. In this paper, we have studied the noise source identification and the characteristics of noise source of rotary compressor for air conditioner using complex sound intensity method. The new method for instantaneous sound intensity is also proposed and it is useful for transient state and steady state. The criteria of these state, select auto correlation coefficient. The advantage, simplicity and economic attribution of this method are verified by analyzing the characteristics of noise source with instantaneous sound intensity compared to mean sound intensity.

  • PDF