• Title/Summary/Keyword: source effect

Search Result 5,521, Processing Time 0.032 seconds

Measurement of Nonlinear Time-variant Source Characteristics of Intake and Exhaust Systems in Fluid Machines

  • Jang Seung-Ho;Ih Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.3E
    • /
    • pp.87-89
    • /
    • 2005
  • The acoustical sources of intake and exhaust systems in fluid machines are often characterized by the source impedance and strength using linear frequency-domain modeling. In the case of the sources which are nonlinear and time-variant, however, the source parameters were sometimes incorrectly obtained. In this paper, the source model and direct measurement technique are modified in order to evaluate the effect due to nonlinear and periodically time-varying source character as well as the linear property of the reflectivity of in-duct fluid machine source. With a priori known kinematical information of the source, the types of nonlinear time-variant terms can be presumed by a simple physical model, in which there is practically no restriction on the form of the model. The concept of source impedance can be extendable by introducing the linear frequency response function for each nonlinear or time-variant input. Extending the conventional method and adapting the reverse MISO technique, it is possible to develop a direct method that can deal with the nonlinear time-variant source parameters. The proposed direct method has a novel feature that there is no restriction on the probability or spectral natures of the excited sound pressure data. The present method is verified by the simulated measurements for simplified fluid machines. It is thought that the proposed method would be useful in predicting the insertion loss or the radiated sound level from intake or exhaust systems.

A Study of the Effect of Grouting Region on the Solution of Line Source Analysis (그라우팅 영역이 선형열원 해석에 미치는 영향에 관한 연구)

  • Lee, Se-Kyoun;Woo, Joung-Son;Ro, Jeong-Geun
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.143-150
    • /
    • 2010
  • Line source method of borehole system assumes the entire surrounding medium is uniform. However, thermal properties of grouting region are considerably different from those of surrounding soil. In this study we investigate the effect of grouting materials on the solution of line source method with the aid of numerical analysis. This numerical model generates the temperature of borehole fluid with which line source solution can be obtained. Then this solution can be compared with input condition of numerical model. The results of this comparison show that thermal conductivity and borehole thermal resistance of line source solution are approximately 86% and 91% of the input condition of numerical model. Chart method is developed in this study to find the numerical input conditions (thermal conductivity and borehole thermal resistance) from the line source solution. Thermal response test of test borehole is conducted, the results of which are approximately consistent with the Chart method. Thermal property changes of grouting materials on the line source solution are also examined.

The Effect of Dietary Selenium Source and Vitamin E Levels on Performance of Male Broilers

  • Choct, M.;Naylor, A.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.7
    • /
    • pp.1000-1006
    • /
    • 2004
  • Selenium and vitamin E are micronutrients essential for normal health and maintenance in poultry. They are necessary in preventing free radical damage to phospholipid membranes, enzymes and other important molecules. Two experiments were conducted in a semi-commercial environment to examine the effect of Se source and vitamin E level in diet on broiler performance and meat quality. Increasing vitamin E from 50 IU to 100 IU did not affect growth performance of broilers although the 24 h drip-loss was tended to be reduced (p=0.06). There was an interaction between vitamin E and the source of Se in glutathione peroxidase activity (GSH-Px) and Se concentration in excreta. Increasing vitamin E from 50 IU to 100 IU elevated GSH-Px and Se concentration in excreta by 42 IU/g Hb and 0.9 ppm for the organic Se group, respectively, but reduced GSH-Px and Se concentration in excreta by 16 IU/g Hb and 1.3 ppm for inorganic group, respectively. Vitamin E played no role in the feather coverage of the birds when scored on day 37. Organic Se is more effective in improving feather score and 24 h drip-loss, with a markedly higher deposition rate in breast muscle and a lower excretion rate in the excreta (p<0.05) compared to the inorganic Se source. Both vitamin E and the source of Se did not affect (p>0.05) the energy utilisation by birds.

The Persuasive Effects according to Types of Exercise Promotion Advertisements for Obesity Prevention in Elementary School Students (초등학생의 비만예방을 위한 운동증진 광고의 유형별 설득효과)

  • An Gyeong Ju;Choe Myoung-Ae;Kim Byoung Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.35 no.5
    • /
    • pp.817-828
    • /
    • 2005
  • Purpose: This study was to identify the persuasive effects of exercise promotion advertisements for obesity prevention according to the source types( ordinary people, experts, celebrity endorsers) and advertising message types(slices of life, testimonials). Method: Gender, height, body weight, BMI, attitude toward obesity(Aob) and exercise(Aex), and intention to exercise(Iex) were collected from 626 elementary school students in a pretest. After 2 months, six advertisements type attached to a questionnaire were provided for 20 minutes and then Aob, Aex, lex, source credibility and attitude toward advertisements(Aad) were collected in posttest. Result: 1) In posttest the lex of 6 the groups increased significantly compared with that of the pretest, 2) Source credibility of the Ordinary+Testimonial group was lower than the Celebrity+Testimonial, Celebrity+Slice of life, Ordinary+Slice of life, and Expert+Testimonial groups, Aad of the Celebrity+Testimonial group was higher than the Ordinary+ Testimonial group. 3) The Main effect and interaction effect of source types and advertising message types were significant in source credibility and Aad, Conclusion: Persuasive effects of exercise promotion advertisements in elementary school students was found to be the most effective in Celebrity+Testimonial. This study suggests that selection of health education advertisements according to demographic characteristics is important to promote persuasive effects.

Simulation Study of Optimizing Multicusp Magnetic Line Configurations for a Negative Hydrogen Ion Source

  • Kim, Jae-Hong;Hong, Seong-Gwang;Kim, Jong-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.250.1-250.1
    • /
    • 2014
  • A multicusp ion source has been used widely in negative hydrogen cyclotrons mainly for radioisotope productions. The ion source is designed to have cusp geometries of magnetic field inside plasma chamber, where ions are confining and their mean lifetimes increase. The magnetic confinement produced a number of permanent magnetic poles helps to increase beam currents and reduce the emittance. Therefore optimizing the number of magnets confining more ions and increasing their mean lifetime in plasma has to be investigated in order to improve the performance of the ion source. In this work a numerical simulation of the magnetic flux density from a number of permanent magnets is carried to optimize the cusp geometries producing the highest plasma density, which is clearly indicated along the full-line cusp geometry. The effect of magnetic fields and a number of poles on the plasma structure are investigated by a computing tool. The electron confinement effect becomes stronger and the density increases with increasing the number of poles. On the contrary, the escape of electrons from the loss cone becomes more frequent as the pole number increases [1]. To understand above observation the electron and ion's trajectories along with different cusp geometries are simulated. The simulation has been shown that the optimized numbers of magnets can improve the ion density and uniformity.

  • PDF

Effect of Partial Flow Reductions on DNAPL Source Dissolution Rate

  • Park, Eung-Yu;ParKer, Jeck C.
    • Proceedings of the KSEEG Conference
    • /
    • 2005.04a
    • /
    • pp.148-151
    • /
    • 2005
  • Field-scale DNAPL dissolution is controlled by the topology of DNAPL distributions with respect to the velocity field. A high resolution percolation model was developed and employed to simulate the distribution of DNAPL within source zones. Statistically anisotropic permeability values and capillary parameters were generated for 10${\times}$10${\times}$10 m domains at a resolution of 0.05 to 0.1 m for various statistical properties. TCE leakage was simulated at various rates and the distribution of residual DNAPL in 'fingers' and 'lenses' was computed. Variations in finger and lens geometries, frequencies, average DNAPL saturations, and overall source topology were predicted to be strongly influenced by statistical properties of the medium as well as by injection rate and fluid properties. Model results were found to be consistent with observations from controlled DNAPL release experiments reported in the literature. The computed distributions of aquifer properties and DNAPL were utilized to perform high-resolution numerical simulations of groundwater flow and dissolved transport. Simulations were performed to assess the effect of grout or foam injection in bore holes within the source zone and of shallow point-releases of fluids with various properties on dissolution in DNAPL dissolution rate, even for widely spaced injection points. The results indicate that measures that induced partial flow reductions through DNAPL source zones can significantly decrease dissolution rates from residual DNAPL. The benefit from induced partial flow reductions is two-fold: 1) local flow reduction in DNAPL contaminated zones reduces mass transfer rates, and 2) contaminant flux reductions occur due to the decrease in groundwater velocity

  • PDF

A Study on the Impedance Effect of Nonvolatile SNOSEFT EFFPROM Memory Devices (비휘발성 SNOSEFT EFFPROM 기억소자의 임피던스 효과에 관한 연구)

  • 강창수;김동진;김선주;이상배;이성배;서광열
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.86-89
    • /
    • 1995
  • In this pacer, The effect of the impedances in SNOSEFT s memory devices has been developed. The effect of source and drain impedances are measuring using the method of the field effect bias resistance in the inner resistance regions of the device structure and external bias resistance. The effect of impedance by source and drain resistance shows according to increasing to the storage of memory charges, shows according to a function of decreasing to the gate voltages, shows the delay of threshold voltages, The delay time of low conductance state and high conductance state by the impedance effect shows 3 [${\mu}$sec] and 1[${\mu}$sec] respectively.

  • PDF

Investigation of Junction-less Tunneling Field Effect Transistor (JL-TFET) with Floating Gate

  • Ali, Asif;Seo, Dongsun;Cho, Il Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.156-161
    • /
    • 2017
  • This work presents a novel structure for junction-less tunneling field effect transistor (JL-TFET) with a floating gate over the source region. Introduction of floating gate instead of fixed metal gate removes the limitation of fabrication process suitability. The proposed device is based on a heavily n-type-doped Si-channel junction-less field effect transistor (JLFET). A floating gate over source region and a control-gate with optimized metal work-function over channel region is used to make device work like a tunnel field effect transistor (TFET). The proposed device has exhibited excellent ID-VGS characteristics, ION/IOFF ratio, a point subthreshold slope (SS), and average SS for optimized device parameters. Electron charge stored in floating gate, isolation oxide layer and body doping concentration are optimized. The proposed JL-TFET can be a promising candidate for switching performances.

Degradation Characteristics of Mobility in Channel of P-MOSFET's by Hot Carriers (핫 캐리어에 의한 피-모스 트랜지스터의 채널에서 이동도의 열화 특성)

  • 이용재
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.1
    • /
    • pp.26-32
    • /
    • 1998
  • We have studied how the characteristics degradation between effective mobility and field effect mobility of gate channel in p-MOSFET's affects the gate channel length being follow by increased stress time and increased drain-source voltage stress. The experimental results between effective and field-effect mobility were analyzed that the measurement data are identical at the point of minimum slope in threshold voltage, the other part is different, that is, the effective mobility it the faster than the field-effect mobility. Also, It was found that the effective and field-effect mobility. Also, It was found that the effective and field-effect mobility of p-MOSFET's with short channel are increased by decreased channel length, increased stress time and increased drain-source voltage stress.

  • PDF

Size-of-source Effect and Self-radiation Effect of an Infrared Radiation Thermometer (적외선 복사온도계의 복사원 크기효과 및 자기복사효과)

  • Yoo, Yong-Shim;Kim, Bong-Hwak;Park, Chul-Woung;Park, Seung-Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.4
    • /
    • pp.133-138
    • /
    • 2010
  • All radiation thermometers have a size-of-source effect (SSE) and a self-radiation effect (SRE). The SSE,defined as dependence of the detector signal of a radiation thermometer on the diameter of a source, is critically dependent on the wavelength since diffraction is the main cause. In this paper, we have measured the SSE and the SRE of TRT2 (Transfer Radiation Thermometer 2, HEITRONICS) widely used as a transfer standard in low and middle temperature range. At $300^{\circ}C$, The radiation temperature difference between the 60 mm diameter blackbody and 10 mm diameter blackbody due to the SSE was estimated to be $3.5^{\circ}C$ in low temperature mode ($8-14\;{\mu}m$) and $0.5^{\circ}C$ in middle temperature mode ($3.9\;{\mu}m$). In addition, the measured radiation temperature difference of the blackbody due to the SRE was found to be 110 mK when the body temperature change of TRT2 was set at $2.6^{\circ}C$.