• 제목/요약/키워드: sound reinforcement system

검색결과 20건 처리시간 0.03초

직선배열 마이크로폰을 사용한 회의용확성장치에 관한 연구 (A Study for the Sound Reinforcement System in Conference Room Using Linear Array Microphone)

  • 김천득
    • 한국음향학회지
    • /
    • 제4권1호
    • /
    • pp.35-42
    • /
    • 1985
  • This paper suggests a method on the use of very long linear array microphone in order to obtain clear loud sound reinforcement system without howling. According to the results of the theoretical investigation, we have made that a linear array microphone. This is made of one hundred small condenser microphone having 2 cm of spatical period. To estimate the effect of sound reinforcement system physically and subjectively, four cases have been experimented : In case of using no sound reinforcement, nondirectivity microphone, rectangular window and Hnning window in linear array microphone. The experimental results prove that the case of Hnning window in linear array microphone is more excellent.

  • PDF

잔향이 많은 공간에서 음향 시스템의 명료도 향상에 관한 연구 (A Study on the Improving Speech Intelligibility of Sound Reinforcement System in Reverberant Rooms)

  • 강성훈
    • 한국음향학회지
    • /
    • 제30권8호
    • /
    • pp.468-473
    • /
    • 2011
  • 잔향이 많은 공간에서는 음성을 명확하게 알아 듣기 어렵다. 음성의 명료도를 확보하는 데는 자음이 중요하므로 잔향음에 비하여 직접음을 크게 하는 것이 중요하다. 잔향이 많은 공간에 음향 시스템을 적절하게 설계하면 흡음 처리하지 않고도 높은 명료도를 얻을 수 있었다. 지향성이 좁은 스피커를 사용하여도 사람이 앉아 있는 영역으로 음을 집중시킬 수 있어서 음성의 명료도를 향상시킬 수 있다. 본 논문에서는 잔향이 많은 공간에서도 실내를 흡음 처리하지 않고 스피커의 지향성을 제어하여 높은 명료도를 얻을 수 있음을 실험을 통하여 제시하였으며, 음향 시스템을 적절히 튜닝함으로써 명료도를 더욱 향상시킬 수 있는 것을 제시하였다.

F.R.P 재료 보강에 의한 신개념 중량충격음 저감대책 (Heavy-weight Impact Noise Reduction of Concrete Slab Reinforcement Using F.R.P)

  • 정정호;유승엽;이평직;전진용;조아형
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.383-386
    • /
    • 2005
  • Low frequency heavy-weight impact noise is the most irritating noise in Korean high-rise reinforced concrete apartment buildings. This low frequency noise is generated by foot traffic due to the fact that Koreans do not wear shoes at home. The transmission of the noise is facilitated by a load bearing wall structural system without beams and columns which is used in these buildings. In order to control low frequency heavy-weight impact noise, floating floors using isolation materials such as glass-wool mat and poly-urethane mat are used. However, it was difficult to control low frequency heavy-weight impact sound using isolation material. In this study, reinforcement of concrete slab using beams and plate was conducted. Using the FEM analysis, the effect of concrete slab reinforcement using FRP(fiber-glass reinforced plastic) on the bang machine impact vibration acceleration level and sound were conducted at the standard floor impact sound test building. The $3{\sim}4dB$ floor impact vibration acceleration level and impact sound pressure level were reduced and the natural frequency of slabs were changed.

  • PDF

벽 및 천장이 흡음재로 마감된 다목적 체육관에서 음원종류에 따른 실내음향특성의 분석 (Analysis of the Room Acoustic Characteristics depending on the Sound Sources for a Multi-purpose Gymnasium finished with Absorbers on Walls and Ceiling)

  • 박현구;전지현;송혁;김선우
    • KIEAE Journal
    • /
    • 제2권1호
    • /
    • pp.41-48
    • /
    • 2002
  • This study aims to investigate and evaluate the room acoustic designs of a multi purpose gymnasiums which do not use adjustable treatments in order to change the acoustical characteristics. Considering the main uses of gymnasium and auditorium, experiments were carried out using both nondirectional speakers on the stage and loudspeaker installed on the ceiling. The result from the study are as follows; Measured RT under unoccupied condition was a little longer than the expected value, therefore, in the case of occupied condition RT would be close to the optimum value. However, parameters that evaluate intelligibility and speech transmission property appeared to be low and have large differences depending on the measuring points, therefore, more effective sound reflecting surfaces and sound reinforcement systems should be considered.

대공간에서 전기음향 시스템에 따른 음향특성 변화 (The Effect of Sound Reinforcement Systems on the Acoustics of a Large-Span Spaces)

  • 정대업;주현경;최영지
    • 한국공간구조학회논문집
    • /
    • 제11권1호
    • /
    • pp.67-75
    • /
    • 2011
  • 본 연구는 컴퓨터 시뮬레이션을 이용하여 대공간에서 스피커 시스템의 변화에 따른 음장의 특성 변화를 검토하였다. 실의 음향특성변화는 실의 흡음력과 동시에 스피커 시스템의 지향성, 설치높이 및 개수를 조절하면서 예측 분석하였다. 연구 결과, 명료도 관련 지표인 D50 및 RASTI는 실의 흡음력 증가의 변화를 효과적으로 나타내는 것으로 분석되었다. 또 초기감쇠시간은 흡음력 증가에 따라 선형적으로 감소하였으나 저 고주파수대역에서는 오히려 증가하거나 변화를 보이지 않았으며, 잔향시간은 전체주파수대역에서 실의 흡음력 증가에 따라 감쇠하였으나 주파수대역별 결과에서는 오히려 증가하거나 비슷한 결과를 보였다. 이는 실의 음향특성이라기 보다는 감쇠구간의 비선형성에 기인한 것으로 판단된다. 스피커 시스템의 적용에 따른 분석결과, D50 및 RASTI는 실의 흡음력 증가에 크게 상관없이 거의 모든 시스템에서 'fair'이상으로 평가되었으며, 스피커의 설치위치가 높을수록 실의 흡음력 증가보다 스피커 지향특성 변화에 더 큰 영향을 받는 것으로 나타났다. 또한 스피커의 설치위치가 낮을수록 실의 잔향시간은 더 짧은 것으로 분석되었다. 시스템의 적용에 따른 잔향시간은 스피커 설치높이가 높을 경우 실의 흡음력 증가에 비례하여 감쇠하는 경향을 보였으나 스피커 설치높이가 낮은 경우 흡음력 증가에 의한 영향보다 시스템의 영향을 받는 것으로 나타났다.

콘크리트 슬래브 압축강도에 따른 바닥충격진동 및 소음특성 (Floor Impact Sound and Vibration Characteristics Affected by the Compressive Strength of Concrete)

  • 정정호;유승엽;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.796-799
    • /
    • 2005
  • In 2005, a regulation on the heavy-weight impact sound was released, which restricted concrete slab thickness of standard floor to 210mm. To reduce heavy-weight impact sound, damping materials and structural reinforcement system have been proposed. In this study, the effect of compressive strength on the heavy-weight impact vibration and sound were investigated. FEM analysis was conducted for the 34PY apartment with different concrete strength (210, 350, 420kg/cm$^2$). In addition, apartment floors with different concrete strength were constructed and the floor impact vibration and sound were measured. Results of FEM analysis and measurement show that the resonance frequency of concrete slab was increased by the increment of concrete strength. However, floor impact sound pressure level did not decrease because the nor impact vibration and sound pressure level in 63Hz band increased.

  • PDF

현장실험을 통한 목조바닥의 구성요소가 충격음 차단성능에 미치는 영향 평가 (Evaluation on Effect of Constitution of Timber Framed Floor on Insulation Performance Against Impact Sound by Field Measurements)

  • 박주생;이상준;김세종
    • Journal of the Korean Wood Science and Technology
    • /
    • 제40권6호
    • /
    • pp.431-444
    • /
    • 2012
  • 바닥구조의 충격음 차단성능은 바닥의 구성요소에 의해 많은 영향을 받는데, 그중 목조 바닥구조의 경우 중량의 흡읍층과 바닥구조의 강성이 주요한 영향인자로 고려되어 왔다. 본 연구에서는 국내 시공된 목조 건축물에 대해서 현장 실험을 통해 바닥 구성요소가 충격음 차단성능에 미치는 영향에 대해서 살펴보았다. 목조 바닥의 충격음 차단성능은 상대적으로 낮은 저주파수 대역에서의 음압레벨에 의해 전체적인 성능이 좌우되었으며, 흡읍층과 바닥구조의 강성 보강에 의해 저주파수 대역 음압레벨을 감소시켜 충격음 차단성능을 향상시킴을 알 수 있었다. 특히, 바닥난방을 위해 설치되는 시멘트 몰탈층과 같은 충격음 흡수층과 원래 경간의 중간 지점에 보를 설치하여 장선 경간을 줄여줌으로써 목조 바닥의 강성을 증가시킨 경우에 중량 충격음 차단성능이 크게 향상되었다.

노후 아파트의 바닥충격음 및 급·배수 소음 저감방안에 관한 연구 (A Study on the Reduction Method of Heavy-weight floor impact sound and Plumbing noise in Decrepit Apartment houses)

  • 주문기;한명호;오양기
    • KIEAE Journal
    • /
    • 제9권2호
    • /
    • pp.99-106
    • /
    • 2009
  • The noise in apartment buildings are major factor that determine the quality of indoor noise environment. Particularly, the noise from children's running footsteps and plumbing noise have caused the residents who live in decrepit apartment houses to uncomfortable environment. And as time go by, sound performance are getting worse according to the aging of the facilities. So this study deals with the plans to improve the sound performance of decrepit apartment house. To compare the noise reduction, we measured the heavy-weight impact sound level and plumbing noise level before and after changes the measurement conditions. As the results of measurements, the heavy-weight impact sound level were decreased when stiffness reinforcement were installed on slab. Especially the sound level were decreased 2.1-7.6dB in 50-80Hz of low frequency range. Instead of PVC pipe system, cast iron pipe and triple elbow drain pipe systems were installed. Noise level were decreased 15dB(A) in 250Hz. Noise level of pipe system's on the slab is less than under slab one. On the contrary water saving stool showed increasing the noise level.

학교체육관에서 스피커 배치방식에 따른 실내음향특성에 관한 연구 (A Study on the Room Acoustic Characteristics according to the Layout System of Speakers in the School Gymnasium)

  • 이주엽;김종빈;박현구;최형욱;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.462-467
    • /
    • 2000
  • The aim of this study is to provide fundamental data for acoustic design by analyzing the room acoustic characteristics according to the PA system used in the school gymnasium. The measurements were carried out accordance with the ISO 3382. The sources used in this study were four types; omni-directional, centralized, distribution, the combination of centralized and distribution sound source system. Omni-directional system is recommended by ISO for the acoustic test and the others are installed on the wall, column and ceiling in the school gymnasium for sound reinforcement.

  • PDF

우리나라 내수면어업의 경쟁력 강화 방안 (A Study on the Reinforcement of the competitive power of Korean Inland Fisheries)

  • 김대영
    • 수산경영론집
    • /
    • 제39권3호
    • /
    • pp.111-137
    • /
    • 2008
  • Fisheries resources living in inland have continuously reduced due to over-fishing and development thoughtless for the environment. Inland fisheries that target the fisheries resources have been also confronted by several problems such as insufficiency of inland fisheries management systems, inconsistent fisheries management system, inferior infrastructure of inland fisheries, and decreasing fishermen's real income. These problems have demotivated fishermen who want to focus on fishing and farming activation. Therefore, this paper provides alternatives of reorganization for turning to sound and healthy inland fisheries industries by reviewing Korean inland fisheries management systems. The reorganization should be preferentially granted resource management by water system considering geographical conditions, seed release, and establishment of fisheries order for maintenance of sound and healthy inland fisheries. Also, the reorganization should be moved toward the competitive strengthening of "company unit" for inland fisheries, the nourishment of fisher-oriented fisheries management system, strong relationship among inland fishermen, the systematic management of inland fisheries, the strengthening of guidance service for inland fisheries, the extension of infrastructure related to fisheries production, the development of inland fisheries policy including public people, and the improvement of inland fisheries system and law reflecting various users of inland fisheries.

  • PDF