• 제목/요약/키워드: sound absorption material

검색결과 152건 처리시간 0.026초

흡음에 의한 도시철도 곡선부 소음저감에 관한 연구 (A Study on Curving noise control by absorption treatment in Urban Rail Transit System)

  • 이재원;손진희;장서일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 춘계학술대회 논문집
    • /
    • pp.603-608
    • /
    • 2002
  • Sound absorbing materials are applied to the exposed surfaces of curved subway tunnel for the reduction of curving noise level. Before the treatment, acoustical engineering simulation is performed to predict the noise level reduction for different kinds and amounts of absorbing material. The principle of geometrical acoustics is utilized to Peform the simulation efficiently and accurately. The noise levels of the inside and outside of running car body are measured to find the noise level reduction. The average noise level reduction of 8 ㏈ has been attained. It has been shown that the simulated results are comparable to the measured ones.

  • PDF

도로교통소음의 방음벽 흡음효과에 관한 연구 (A Study on the Effects of Absorptive Treatments for the Highway Noise Barriers)

  • 김재석;루이스칸;김갑수
    • 소음진동
    • /
    • 제8권1호
    • /
    • pp.146-156
    • /
    • 1998
  • 자동차의 폭발적인 증가와 아울러 경부고속전철시대를 맞이함으로 인하여 소음공해는 큰 사회적 문제로 대두되고 있다. 본 연구는 이러한 소음공해에 대한 해결책의 일환으로 효율적인 방음벽을 연구 하는데 그 목적이 있다. 방음벽의 연구는 먼저 반사형 방음벽과 흡음형 방음벽에 대한 소음저감효과 를 산정한 다음, 흡음재료를 사용함으로서 감소되는 소음저감 효과를 산정하는데 큰 의의가 있다. 본 연구결과에 의하면 방음벽의 높이에 비하여 음의 파장이 대체로 짧을 때는 방음벽의 상단부분에 흡음재를 설치하면 방음벽 전체에 흡음재를 설치한 것과 같은 효과가 있다는 결론을 얻었다. 도로교통소음은 평균주파수가 550Hz 이므로 이때 파장은 60cm 정도이다. 방음벽 높이를 4m로 설치했을 때 방음벽 상단에서 60cm 정도만 흡음재를 사용하면 4m전체의 방음벽에 흡음재를 사용한 것과 같은 효과가 있는 것으로 나타났다. 흡음재를 사용한 소음저감의 효과는 점음원이고 수음자의 위치가 $135^{\circ}$ 일 때 평균 8dB(A)정도이고, 선음원일때는 평균 3dB(A)정도의 효과가 있는 것으로 나타났다 이러한 흡음형의 방음벽은 경제적일 뿐만 아니라 방음벽의 높이를 최소한 1m이상 줄일 수 있으므로 국토를 고도로 이용해야 되는 우리 나라의 여건에 대단히 효과적인 방음벽이라 사료된다.

  • PDF

음향시뮬레이션을 이용한 실내음향해석 - Multiplex 영화관을 대상으로 - (Indoor Acoustic Analysis Using Acoustic Simulation Of Multiplex Cinema)

  • 윤창연;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.587-593
    • /
    • 2000
  • The background noise and transmission loss of wall were measured on site for the multiplex cinema. The results from the simulation analysis was compared with the measurements from the site for different frequencies to review the acoustical parameters, and the analysis results in the relatively small error. Therefore, it is concluded that the reliable estimation can be made once accurate data such as sound source and sound absorption coefficient of interior material is utilized during the simulation process. However, the calibration is necessary for the test room with the small room volume.

  • PDF

다공성 재료의 물리적 성질 추정 방법에 대한 연구 (A Study on Estimation Method for Physical Properties of Sound Absorbing Materials)

  • 김윤재;강연준;김정수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.118-121
    • /
    • 2005
  • The acoustical performance of porous materials is determined by their seven or more macroscopic physical properties. However, it is not easy to measure all these properties in many cases. Furthermore, the measurement is compels engineers to spend much times. The effect of each property on the normal incidence absorption coefficient and normalized surface impedance was studied to estimate the properties of porous materials by numerical method. According to the investigation, Properties of porous materials are divided into several groups and estimated by each group. This paper is focused on the estimation procedure of porous materials by the numerical method.

  • PDF

웨이브렛 변환을 이용한 잔향시간의 측정 (Estimation of Reverberant Time Using Wavelet Transform)

  • 이상권;김봉기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1762-1766
    • /
    • 2000
  • Estimation of reverberant time is one of important factor for the calculation of absorption ration of absorption material. In general the digital filter bank has been used for the, estimation of decay curve of the sound pressure in a reverberant room. However at low frequency, it is not easy to get a good linear decay curve for the estimation of reverberant time. Now, wavelet transform is applied to this difficult task, a good result has been obtained at low frequency. The decay curve using wavelet filter bank is better than that using digital filter bank at low frequency. At higher frequency, both curves are similar.

  • PDF

유한요소법에 의한 흡음재 음향특성 연구 및 검증 (Finite Element analysis of Acoustic Behavior of Absorbent Materials with experimental Verification)

  • 정환익;김관주;박진규;김상헌
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.874-878
    • /
    • 2003
  • Acoustic materials are used for the purpose of absorbing noise and reducing transmission of sound into the receiving room. The purpose of this research is to predict the performance of absorbent materials with respect to absorbing behavior and transmission loss as possible as accurately. The performance of the absorbent materials are carried out systematically as follows: The Biot parameter are measured, first. Then using above parameters as input, LMS's SYSNOISE and VIOLINS programs are used to predict absorption coefficient and transmission loss values, which magnitudes are compared with experimental results. As an sample acoustic material, SK SKY VIVA and PET are selected.

  • PDF

흡음재 배치를 이용한 정숙 공간 형성 방법 (Quiet Zone Generation by Absorption Materials)

  • 박주배;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.403-408
    • /
    • 2000
  • An acoustic field in a 3 dimensional enclosure is caused from interference between sound sources and the complex reflections from wall. Therefore, changing an acoustic property of wall such as admittance means generating another acoustic field. The purpose of this paper is utilizing the characteristic to make a quiet zone. First, this paper shows that the control material is essentially on the same road as active noise control(ANC). That is, we can consider the control material as the control source of ANC. However we cannot control the reflection strength of it. Second, through a numerical simulation, this paper shows that the position of the control material is an important variable of the control.

  • PDF

축척 모형을 이용한 근접 저상 방음벽의 음향성능평가 및 예측 (Acoustic Performance Evaluation and Prediction for Low Height Noise Barriers Installed Adjacent To Rails Using Scale Down Model)

  • 윤제원;장강석;조용성
    • 한국철도학회논문집
    • /
    • 제19권2호
    • /
    • pp.124-134
    • /
    • 2016
  • 철도 선로에 근접하여 설치하는 근접 저상 방음벽은 방음벽 높이를 저감시키기 위한 방안으로 외국에서는 많은 연구가 수행되고 있으나 국내에서의 연구는 매우 미흡한 실정이다. 본 논문에서는 근접 저상 방음벽의 음향특성을 파악하고자 축척 모형을 제작하여 성능평가를 수행하였다. 실험결과, 'ㄱ'자형 방음벽 설치 시에는 방음벽의 안쪽뿐만 아니라 상부에도 흡음재를 설치하는 것이 삽입손실의 개선효과가 있는 것으로 분석되었고, 방음벽의 삽입손실 평가를 위해 단순한 경험식 대신에 경계요소법과 같은 보다 해석적인 방법으로 삽입손실을 예측할 필요가 있다. 또한, 흡음재를 부착한 근접 방음벽을 설치하면 승객 위치에서의 소음 증가현상은 미미한 것으로 분석되었다. 그리고, 근접 방음벽의 음향성능 예측을 위해 2차원 경계요소법을 이용한 소음해석을 수행하였으며, 측정결과와의 비교 분석을 수행함으로서 예측 프로그램의 활용 가능성을 검증하였다.

방음판의 음향투과손실 측정규격에 관한 연구 (A study on the standard for determining airborne sound insulation performance of sound barrier panels)

  • 오양기
    • 한국음향학회지
    • /
    • 제41권3호
    • /
    • pp.302-311
    • /
    • 2022
  • 방음벽은 도심구간의 도로 및 철도에서 환경소음 저감을 위한 가장 효율적 대안의 하나이다. 도로교통소음 등에 대한 방음벽의 삽입손실은 방음판의 음향투과손실, 흡음손실 및 방음벽의 회절감쇠에 의한 음에너지 저감량의 합으로 이루어진다. 방음판의 음향투과손실은 방음벽의 삽입손실을 결정하는 중요한 요인 중 하나로 방음벽의 성능을 결정하는 기본적인 지표이다. 그럼에도 불구하고 아직까지 우리나라는 방음판의 음향투과손실 측정방법에 관한 별도의 규격이 없다. 방음판의 일반적 재질에 대해 규정하고 있는 KS F 4770 시리즈의 한두 항목으로 가볍게 다루고 있을 뿐이다. 이 논문은 방음판의 음향투과손실 측정 및 평가 규격의 필요성에 대해 고찰하고, 실내 건축부재와 달리 외부공간에 설치되는 방음벽의 특성을 감안한 자유음장(무향실) 수음실에서의 측정방법을 모색하였다. 아울러 도로변이나 철로변 등 다양한 설치장소에 따른 방음효과를 간단히 표시할 수 있도록 기준 스펙트럼을 활용한 단일수치 평가법을 제안하였다.

저속 주행시 자기부상열차의 실내소음저감에 관한 연구 (A Study Interior Noise Reduction of a Maglev Train at Low Speed)

  • 김현실;김재승;강현주;김봉기;김상렬
    • 한국소음진동공학회논문집
    • /
    • 제11권7호
    • /
    • pp.253-260
    • /
    • 2001
  • A Study of interior noise reduction in the magelv train is presented. Tarin speed of interest is low such that aero-dynamic noise is negligible and power supply system is a dominant noise source. Based on the measurements of interior noise and acceleration levels during running and zero speed conditions, dominant noise sources are identified. After spectra characteristics of noise sources are investigated several noise reducing methods are studied such as STL increasement of floor panels. sealing. and absorption treatment It is found that the most important noise sources are VVVF inverter and SLM in running condition, whereas air conditioner and DC/DC converter are dominant in zero speed. Sine the major noise sources are under the floor complete sealing and high STL of the floor panel are shown to be the most crucial factors in noise reduction After sound absorbing material, which is polyurethan foam of 50 mm thickness, is thickness, is attached to the downward side of the floor in addition to sealing treatment, the interior noise is reduced by 3~4 dB.

  • PDF