• Title/Summary/Keyword: sonographer

Search Result 20, Processing Time 0.019 seconds

A Study on Work-Related Musculoskeletal Disorders Related to Sonographer's (진단 초음파 검사자의 작업 관련 근골격계질환 연구)

  • An, Hyun
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.355-363
    • /
    • 2022
  • This study was to investigate the prevalence rate of musculoskeletal disorders in relation to general characteristic factors, living environment factors, and work environment factors for sonographer's. For the response questions, the guidelines for musculoskeletal burden work were used. For statistical analysis, SPSS 26.0 version was used. For the common body parts of the sonographer's who responded, the prevalence was investigated by dividing the group into a group with high pain or discomfort and a group with low pain or discomfort according to the degree to which they experienced symptoms during the past 12 months. Multiple logistic regression analysis was used to determine the variance inflation factor(VIF), odds ratio (OR) and corresponding 95% confidence interval (CI). A p-value of <0.05 was considered statistically significant. As a result, housework hours, examination history, regular physical activity, number of patient examinations per day, and sitting posture were investigated as variables for rate musculoskeletal disorders. The sonographer's occupational group was found to have a high prevalence rate of musculoskeletal disorders like various other occupational groups. Based on the results of this study, it is judged that musculoskeletal disorders can be reduced by recognizing musculoskeletal disorders and improving work environment factors.

Optimal Ambient Illumination Study for Soft-Copy Ultrasound Images (소프트 카피 초음파 이미지를 보기 위한 최적의 주변광 조도 연구)

  • An, Hyun;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.209-216
    • /
    • 2019
  • The purpose of this study was to suggest the optimum ambient illumination level for proper visualization in image inspection and reading on CRT and LCD monitors used for ultrasound and reading. The evaluators were divided into 4 groups: 20 (Ultra-sonographer: 20 groups (4 groups: ultra-sonographer, 1-5 years, 5 ultra-sonographers, 6 to 10 years, 5 ultra-sonographers, 11 to 15 years, The subjects were 32 questions. The evaluation method was image evaluation of ultrasonic soft copy images for 30 seconds per 10, 25, 100Lux ambient illumination. The evaluation results were evaluated as 6 points (Normal = Definitely no lesion), 2 points = possibly not a lesion, 3 points = probably not a lesion, 4 points = possibly a lesion, 5 points = probably a lesion, 6 points = Definitely a lesion). In this study, the results of ROC analysis according to ambient light illumination reading softcopy images used for lesion detection of all ultrasound images showed the highest sensitivity, specificity, and AUC results at 10Lux. It was found that optimal use of 10Lux for ambient light illumination would provide optimal detection of lesions in ultrasound soft copy images. Based on the future research data, it will be presented as basic data for designing ambient light brightness of ultrasound imaging laboratory and reading room.

A Study on the Perception of Infection Control in Ultrasound Diagnostic Room (초음파검사실 감염관리 인식에 대한 연구)

  • An, Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.367-374
    • /
    • 2020
  • The purpose of this study is to understand the infection prevention system and infection management perception of Ultrasound diagnostic room in medical institutions by sonographer's in general practitioner, semi and general hospitals. As a research method, a statistical analysis was conducted by surveying a total of 20 items in four category to determine the infection perception of sonographer's according to gender, age, working institution, and working period. As a result of infection awareness, males were in the ultrasound gel management category, women were in the transducer management category, all age groups were in the transducer management system category, and the General Practitioner, semi and general hospitals. were in the transducer management system category, and general hospitals showed a high degree of infection awareness in the category of disinfection and sterilization, and in the category of transducer management in the entire working period. In the results of the analysis of the correlation between the sub-factors of the perception of infection control in the Ultrasound diagnostic room the degree of correlation between each category showed a middle degree correlation(r>0.5) and a significant difference by category(p<.01). In conclusion, the prevention of infection in the ultrasound diagnostic room, which sonographer's firms think, was found to be the most efficient ultrasound diagnostic room infection control to implement transducer and gel management in accordance with the principles of disinfection and sterilization.

The Factor Which Influence Musculoskeletal Symptoms in Diagnostic Medical Sonographer (초음파 검사자의 근골격계 증상에 영향을 주는 요인)

  • Kang, Seon-Hee;Kim, Tae-Hyoun
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.227-236
    • /
    • 2007
  • We investigated the factors which influence the musculoskeletal symptoms in diagnostic medical sonographer. The Korean Society of Medical Sonographer conducted a survey through e-mail. Of the 400 subjects, 124 subjects responded(31%). The number of abdominal sonographer was 72(71.3%), obstetrics sonographer was 20(19.8%), echocardiographer was 9(8.9%) for effective 101 participant among themselves. According to the NIOSH diagnostic criteria, 86 subjects(85.1%) had musculoskeletal symptoms on their shoulders/neck, 73 subjects(72.3%) on their hands/wrists/arms/elbows, 44 subjects(43.6%) on their lower back. The factor of musculoskeletal symptoms were analyzed by the logistic regression analysis. The factors of symptoms for the hands/wrists/arms/ elbows were official autonomy, number of scans performed per week. The factors of symptoms for the shoulders/neck and the lower back were work break. However scan type were not observed as a significant factor. The study came to conclusion that many study subjects experienced musculoskeletal symptoms. These measures should be taken properly and promptly by the hospital's administrators.

  • PDF

Sonographer's Job Stress and its Effects on Job Satisfaction: Focused on Busan and Ulsan (초음파 검사자의 직무 스트레스가 직무만족도에 미치는 영향: 부산, 울산지역을 중심으로)

  • Yang, Sung-Hee;Lee, Jin-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.263-271
    • /
    • 2017
  • The purpose of this study was to investigate the relationship between general characteristics, job stress and job satisfaction of 150 sonographer working in Busan and Ulsan area and to identify the predictors of job satisfaction. As a result, the higher the age, experienced job change, the more job satisfaction increased. The sub-factors of job stress and job satisfaction are significantly negative correlated with organizational system, lack of reward, occupational climate, job insecurity, insufficient job control, job demand. The most influential variables in job satisfaction were organizational system and lack of reward. Therefore in order to increase the job satisfaction of the sonographer, it is important to establish and institutional device related to effective organization, manpower management and compensation to reduce job stress.

Study on the Agreement Values of Pulmonary Arterial Hypertension Measured by Cardiac Sonographers (심장초음파 검사자 간의 폐동맥고혈압 진단 측정값 일치도 분석 연구)

  • Seol Hwa KIM;Sundo JUNG
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.4
    • /
    • pp.269-275
    • /
    • 2023
  • Echocardiography is a non-invasive method that is useful for diagnosing pulmonary arterial hypertension. It is known that echocardiography depends on the experience, education, and knowledge level of the cardiac sonographer. This study aimed to compare the agreement values between cardiac sonographer with different practical experiences in the diagnosis of pulmonary arterial hypertension using echocardiography. Three readers re-evaluated the echocardiography images of 148 patients who were diagnosed with pulmonary arterial hypertension at the S Medical Center from January 1, 2020, to December 31, 2020. The echocardiography values measured by each reader were compared and analyzed. The results of the analysis of discrete variables revealed that the agreement values of the cardiac sonographers showed excellent consistency for both reader 3 and the cardiologist group, indicating that more experience leads to better predictive accuracy for diagnosis of the condition. Furthermore, in terms of continuous variables, all the cardiac sonographer demonstrated good agreement in the measured values of the right atrium, which was easier to assess and clearer than the structurally complex measurements of the right ventricle. This study represents the first analysis in Korea of the agreement values measured by medical technologists who are cardiac sonographers.

Job Competency in Ultrasonography of Korean Radiological Technologists (한국 방사선사의 초음파진단검사 직무역량에 관한 고찰)

  • Lim, Chang Seon;Kim, Chuk Bok;Namkung, Jang Sun;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.857-864
    • /
    • 2019
  • Many countries, including Canada, operate a sonographer license system separately from a radiological technologist license. However, in Korea, radiological technologists perform ultrasound imaging under the guidance of doctors. Therefore, in order to have the opportunity to provide a systematic education by analyzing the job competency of the radiological technologist's ultrasound imaging, based on the Canadian National Competency Profile (NCP) lists, this study measured the job content validity of the job competences and detailed competencies required for performing ultrasonography in Korea. From the results of comparing and analyzing the importance of the core competencies included in the Korean radiological technologist's job competencies and the degree of job performance, the average overall importance was 4.087, the average of overall performance was 3.640, showing that the importance was higher than the performance and that there was a statistically significant difference. In conclusion, 'A Communication', 'B Professional responsibilities', 'D Operation of equipment' and 'G Workplace health and safety' showed high job content validity. However, it is said that as 'C Patient assessment and care', 'E Critical thinking and problem solving', and 'H Image' showed low job content validity, it is necessary to seek ways to strengthen and complement these competencies.

Professional Certification of Medical Technologists in Korea, Japan, and United States of America (한국, 일본, 미국 임상병리사 전문자격)

  • Koo, Bon-Kyeong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.1
    • /
    • pp.1-14
    • /
    • 2019
  • The names of medical technologist in Korea, Japan, and the United State of America vary depending on the medical system, educational system, and work areas. Conventionally, jobs equal or similar to medical technologist (commonly known as clinical laboratory technologist, medical laboratory technologist, clinical laboratory scientist, and medical laboratory scientist), histotechnologist, cytotechnologist, and genetic technologist. Jobs, such as extracorporeal technologist, medical electrophysiology technologist, and medical sonographer, allow other allied health professionals including medical technologists, to obtain their qualification. The work areas of medical technologists are classified into clinical pathologic technology, pathologic technology, clinical genetics technology, nuclear medicine in vitro technology, and clinical physiologic technology. New titles of Korean specialized medical technologists refer to certification systems, such as CLMJ, CMAJ, ASCP, IAC, ABRET, and ARMDS. Currently, there are eight types of specialized medical technologists under the cooperation of specialized academic societies. They are hematology, transfusionology, chemistry, immunology, microbiology, histology, cytology, nuclear medicine. It can be further divided into 20 categories according to the work areas such as mass spectrometry, infection control, Pathologists' Assistant, flow cytometry, HLA, cytogenetics, molecular genetics, cardiopulmonary physiology, neurophysiology (EEG/EMG/PSG/etc.), cardiac sonography, neurosonography (TCD/carotid), and medical device quality manager.

A Scope of Work of Radiological Technologists for Ultrasound Examinations (초음파검사에 대한 방사선사 업무범위의 법적 고찰)

  • Lim, Chang Seon;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.481-490
    • /
    • 2021
  • There is no qualification system for sonographers in Korea. But the MEDICAL SERVICE TECHNOLOGISTS, ETC. ACT stipulates that radiological technologists can handle ultrasound equipment. However, there is controversy about the scope of the work allowed for radiological technologists to perform ultrasound examinations. Accordingly, the authoritative interpretation of the Ministry of Health and Welfare of Korea, the adjudication of administrative judgment, and the judgment of the courts were analyzed. As a result, the authoritative interpretation expresses that when a radiological technologist performs an ultrasound examination, a diagnosis and specific guidance should be made in real time while the doctor simultaneously watches the radiological technologist's images. In the adjudication of administrative judgment, it was decided that the handling of ultrasound-related equipment was the work of the radiological technologist. The court ruled that it was illegal for a radiological technologist to make a medical judgment on ultrasound examination. In the United States, Canada, etc., the sonographer independently conducts ultrasound examination according to the doctor's prescription, prepares a summary of what they saw and this is passed on to the doctor. Therefore, in Korea, there is a need for institutional improvement so that radiological technologists can perform ultrasound examinations according to doctors' prescriptions without real-time guidance.

Gage R&R Study on Abdominal Sonography for Measuring Distance from Sangwan (CV13) to Pancreas - A Pilot Study - (복부초음파를 이용한 상완혈(上脘穴)-췌장 수직거리 측정시스템의 재현성 반복성 평가실험-A Pilot Study-)

  • Nam, Dong-Hyun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.2
    • /
    • pp.75-84
    • /
    • 2010
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from Sangwan (CV13) to pancreas. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from CV13 to pancreas with a ultrasound device three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from CV13 to pancreas was 6.29. So we concluded that repeatability and reproducibility of the ultrasound device system for measuring distance from CV13 to pancreas was acceptable.