• 제목/요약/키워드: soluble chloride content

검색결과 54건 처리시간 0.025초

Effects of Relative Humidity and Temperature on the Transport of Chloride in the Concrete

  • Nam Jin-Gak;Hartt William H.;Kim Ki-Joon
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.821-828
    • /
    • 2005
  • To investigate the role of RH and temperature on the transport of chloride in the concrete, two groups of specimens were configured. For both groups, mix design was based on w/c=0.45, $400kg/m^3$ cement, $794kg/m^3$ fine aggregate and $858kg/m^3$ coarse aggregate. After specimen fabrication these were exposed to four different RH (35, 55, 75 and $95\%$ RH) and temperature (0, 20, 30 and $40^{\circ}C$) conditions. After 3 and 6 months $15\%$ NaCl exposure 5mm cores were taken. These cores were sliced and individual cores were ground to powder. In addition, to evaluate the effect of temperature on the chloride binding some powder samples were leached in the each of four temperature chambers. Chloride titration fur these was performed using FDOT acid titration method. Based upon the resultant data conclusions were reached regarding that 1) effective diffusion coefficient, $D_e$, increased with increasing exposure RH, suggesting that the size and number of water paths increased with elevated moisture content in the specimens, 2) $D_e$ increased with increasing temperature in the range of 0 to $40^{\circ}C$ possibly by elevated thermal activation of chloride ions and reduced chloride binding at higher temperature, 3) water soluble chloride concentration, $[Cl^-]_s$, increased with increasing temperature, and 4) chloride concentration profile for initially dry concrete specimens was higher than for the initially wet ones indicating pronounced capillary suction (sorption) occurred for the dry concrete specimens.

CA2 혼입 페이스트의 부식저항성에 관한 연구 (A Study on Corrosion Resistance of CA2-Mixed Paste)

  • 김재돈;장일영
    • 한국산업융합학회 논문집
    • /
    • 제25권2_2호
    • /
    • pp.289-297
    • /
    • 2022
  • Deterioration in durability of structures due to the steel corrosion is difficult to determine whether or not corrosion is initiated and how much propagated, and moreover, repair and maintenance are not easy to deal with. Therefore, preventive treatments can be the best option to avoid the deterioration. Various methods for preventing corrosion of steel, such as electrochemical treatments, anti-corrosion agents and steel surface coatings, are being developed, but economic and environmental aspects make it difficult to apply them to in-situ field. Thus, the purpose of this study was to improve corrosion resistance by using CA-based clinker that are relatively simple and expected to be economically profitable Existing CA-based clinkers had problems such as flash setting and low strength development during the initial hydration process, but in order to solve this problem, CA clinker with low initial reactivity were used as binder in this study. The cement paste used in the experiments was replaced with CA2 clinker for 0%, 10%, 20%, and 30% in OPC. And the mixture used in the chloride binding test for the extraction of water-soluble chloride was intermixed with Cl- 0.5%, 1%, 2%, and 3% by weight of binder content. To evaluate characteristic of hydration heat evolution, calorimetry analysis was performed and simultaneously chloride binding capacity and acid neutralization capacity were carried out. The identification of hydration products with curing ages was verified by X-ray diffraction analysis. The free chloride extraction test showed that the chlorine ion holding ability improved in order OC 10 > OC 30 > OC 20 > OC 0 and the pH drop resistance test showed that the resistance capability in pH 12 was OC 0 > OA 10 > OA 20 > OA 30. The XRD analyses showed that AFm phase, which can affect the ability to hold chlorine ions, tended to increase when CA2 was mixed, and that in pH12 the content of calcium hydroxide (Ca(OH)2), which indicates pH-low resistance, decreased as CA2 was mixed

융빙제 사용으로 인해 열화된 콘크리트 구조물의 내구성 조사 (The Investigation of Deteriortion of Concrete Structures due to the De-icing Salts)

  • 문한영;김성수;류재석;김홍삼
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.77-82
    • /
    • 1996
  • The study was performed for the purpose of obtaining the fundamental data to improve the durability of concrete structures due to de-icing salts. To assume the degree of concrete deterioration, soluble chloride content in concrete, the depth of carbonation and compressive strength of core specimens were measured. The porgress of corrosion of concrete bridge was electrochemically monitored. The results show that the concrete structure was deteriorated and reinforced steel in concrete was corroded due to de-icing salts.

  • PDF

Solute patterns of four halophytic plant species at Suncheon Bay in Korea

  • Choi, Sung-Chul;Choi, Deok-Gyun;Hwang, Jeong-Sook;Kim, Jong-Guk;Choo, Yeon-Sik
    • Journal of Ecology and Environment
    • /
    • 제37권3호
    • /
    • pp.131-137
    • /
    • 2014
  • To investigate the solute pattern of salt marsh plants in Suncheon Bay in Korea, plants and soil samples were collected at three sites from July to September 2011. The soil pH around the investigated species was weakly alkaline, 6.9-8.1. The total ion and Cl- content of site 1 gradually increased, while those of site 2 and site 3 were lowest in August and highest in September. The exchangeable $Ca^{2+}$, $Mg^{2+}$ and $K^+$ in the soil were relatively constant during the study period, but the soil exchangeable $Na^+$ content was variable. Carex scabrifolia and Phragmites communis had constant leaf water content and very high concentrations of soluble carbohydrates during the study period. However, Suaeda malacosperma and S. japonica had high leaf water content and constant very low soluble carbohydrate concentrations. Carex scabrifolia accumulated similar amounts of $Na^+$ and $K^+$ ions in its leaves. Phragmites communis contained a high concentration of $K^+$ ions. Suada japonica and S. malacosperma had more $Na^+$ and $Cl^-$ ions than $K^+$ ions in their leaves. Suaeda japonica had higher levels of glycine betaine in its leaves under saline conditions than C. scabrifolia and P. communis. Consequently, the physiological characteristics of salt marsh chenopodiaceous plants (S. japonica and S. malacosperma) were the high storage capacity for inorganic ions (especially alkali cations and chloride) and accumulation of glycine betaine, but monocotyledonous plant species (C. scabrifolia and P. communis) showed high $K^+$concentrations, efficient regulation of ionic uptake, and accumulation of soluble carbohydrates. These characteristics might enable salt marsh plants to grow in saline habitats.

염화물에 의한 철근콘크리트 구조물의 철근부식 정도의 조사 및 평가 (An Investigation and Evaluation of Steel Corrosion Due to Chlorides in Concrete Structure)

  • 문한영;이창수;김성수;김홍삼;이종상
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.633-636
    • /
    • 1998
  • This study is performed for the purpose of obtaining the fundamental datum to analyse the cause of steel corrosion in concrete and establish the repair strategies of deteriorated reinforced concrete structures due to steel corrosion. To investigate the degree of concrete deterioration, soluble chloride content in harden concrete, the depth of carbonation, cover depth and compressive strength are measured. The progress of corrosion of concrete bridge is electrochemically evaluated. The result shows that in approximately 43% of the structures below -350mV(vs. CSE), the exessive chloride contents is a direct cause of steel corrosion in reinforced concrete structures.

  • PDF

Evaluation of feed value of a by-product of pickled radish for ruminants: analyses of nutrient composition, storage stability, and in vitro ruminal fermentation

  • Jeon, Seoyoung;Sohn, Keun-Nam;Seo, Seongwon
    • Journal of Animal Science and Technology
    • /
    • 제58권9호
    • /
    • pp.34.1-34.9
    • /
    • 2016
  • Background: By-products of pickled radish (BPR) are considered food waste. Approximately 300 g/kg of the total mass of raw materials becomes BPR. Production of pickled radish has grown continuously and is presently about 40,000 metric tons annually in Korea. The objective of the present study was thus to explore the possibility of using BPR as a ruminant feed ingredient. Results: BPR contained a large amount of moisture (more than 800 g/kg) and ash, and comprised mostly sodium (103 g/kg DM) and chloride (142 g/kg DM). On a dry matter basis, the crude protein (CP) and ether extract (EE) levels in BPR were 75 g/kg and 7 g/kg, respectively. The total digestible nutrient (TDN) level was 527 g/kg and the major portion of digestible nutrients was carbohydrate; 88 % organic matter (OM) was carbohydrate and 65 % of total carbohydrate was soluble or degradable fiber. The coefficient of variation (CV) of nutrient contents among production batches ranged from 4.65 to 33.83 %. The smallest CV was observed in OM, and the largest, in EE. The variation in CP content was relatively small (10.11 %). The storage stability test revealed that storage of BPR at $20^{\circ}C$ (room temperature) might not cause spoilage for 4 d, and possibly longer. If BPR is refrigerated, spoilage can be deferred for 21 d and longer. The in vitro ruminal fermentation study showed that substitution of annual ryegrass straw with BPR improved ruminal fermentation, as evidenced by an increase in VFA concentration, DM degradability, and total gas production. Conclusion: The major portion of nutrients in BPR is soluble or degradable fiber that can be easily fermented in the rumen without adverse effects, to provide energy to ruminant animals. Although its high sodium chloride content needs to be considered when formulating a ration, BPR can be successfully used as a feed ingredient in a ruminant diet, particularly if it is one component of a total mixed ration.

The Regulation of Sugar Metabolism in Huangguan Pears (Pyrus pyrifolia Nakai) with Edible Coatings of Calcium or Pullulan during Cold Storage

  • Kou, Xiaohong;Jiang, Bianling;Zhang, Ying;Wang, Jun;Xue, Zhaohui
    • 원예과학기술지
    • /
    • 제34권6호
    • /
    • pp.898-911
    • /
    • 2016
  • Sugars play many important roles in plant metabolism and directly influence fruit quality. The effects of two edible coatings, 2% calcium chloride and 1% pullulan, on sugar metabolism in postharvest Huangguan pear fruit were investigated during cold storage. The respiration rate, sugar content and composition, sucrose metabolism enzyme activities [acid invertase (AIV), neutral invertase (NI), sucrose synthase (SS), and sucrose phosphate synthase (SPS)] and expression of the AIV gene were analyzed during storage at $0^{\circ}C$ for 210 days. Coating treatments slowed the decrease of sucrose and hexose, the respiration rate, and the activities of AIV, NI, SS and SPS, thus maintaining high total soluble solids (TSS) and titratable acid (TA) contents in the fruit. There were no significant differences in AIV expression or activity between the treated and control groups of fruits. Both of the coatings could inhibit the activities of sucrose-cleaving enzymes, thus slowing the decrease of sugar content and maintaining high fruit quality during cold storage.

Condition assessment of aged underground water tanks-Case study

  • Zafer Sakka;Ali Saleh;Thamer Al-Yaqoub;Hasan Karam;Shaikha AlSanad;Jamal Al-Qazweeni;Mohammad Mosawi;Husain Al-Baghli
    • Structural Engineering and Mechanics
    • /
    • 제90권5호
    • /
    • pp.493-504
    • /
    • 2024
  • This paper presents the methodology and results for the investigation of the structural safety of 40 aged underground water tanks to support the weight of photovoltaic (PV) systems that were supposed to be placed on their roof reinforced concrete (RC) slabs. The investigation procedure included (1) review of available documents; (2) visual inspection of the roof RC slabs; (3) carrying out a series of nondestructive (ND) tests; and (4) analysis of results. Out of the 40 tanks, eleven failed the visual inspection phase and were discarded from further investigation. The roof RC slabs of the tanks that passed the visual inspection were subjected to a series of ND tests that included infrared thermography, impact echo, ultrasonic pulse velocity (UPV), Schmidt hammer, concrete core compressive strength, and water-soluble chloride content. The NDT results proved that eight more tanks were not suitable to support the PV systems. Based on the results of the visual inspection and testing, a probabilistic decision-making criterion was established to reach a decision regarding the structural integrity of the roof slabs. The study concluded that the condition of the drainage filter was essential in protecting the tanks and its intact presence can be used as a strong indication of the structural integrity of the roof RC slabs.

폴리(비닐 알코올)과 N-(2-하이드록시)프로필-3-트리메틸 키토산 클로라이드 블렌드의 제조와 특성 분석 (Preparation and Characterization of the Blends of Poly(vinyl alcohol) and N-(2-hydroxy)propyl-3-trimethylammonium Chitosan Chloride)

  • 김영호;최재원;이은영
    • 폴리머
    • /
    • 제27권5호
    • /
    • pp.405-412
    • /
    • 2003
  • 수용성 고분자인 폴리(비닐 알코올) (PVA)과 키토산에 제 4급 암모늄염을 도입하여 합성한 수용성 키토산 유도체인 N-(2-하이드록시)프로필-3-트리메틸 키토산 클로라이드 (HTCC)를 수용액 상태로 하여 용액 블렌딩하고 이를 캐스팅하여 PVA/HTCC 블렌드 필름을 제조한 후 두 고분자 사이의 혼화성과 블렌드 필름의 특성을 FT-IR, DSC, DMA 및 TGA를 사용하여 검토하였다. HTCC 함량을 50%까지 변화시킨 본 연구의 혼합 범위에서 블렌드 필름들은 모두 투명한 상태를 나타내었으며, T$_{g}$와 T$_{m}$ 이 하나로 나타나 두 고분자 사이에 혼화성이 있음을 확인하였다. 또, HTCC의 우수한 항미생물성 때문에 HTCC가 1%만 포함되더라도 블렌드 필름은 우수한 항미생물성을 나타내었다.

서울시내 위치한 콘크리트 고가차도의 내구성능 조사 및 평가 (Investigation and Evaluation on Performance of Durability for Freeway Concrete Viaducts in Seoul Metropolitan Area)

  • 이창수;윤인석
    • 한국방재학회 논문집
    • /
    • 제2권1호
    • /
    • pp.143-152
    • /
    • 2002
  • 본 연구는 서울시내 위치한 39개 콘크리트 고가차도의 중성화 깊이, 가용성 염화물량 및 철근의 자연전위 등을 측정하여 열화의 원인을 분석하기 위한 기초자료를 얻고자 하였다. 전체 조사대상 구조물 가운데 철근위치까지 중성화 깊이가 진행된 구조물은 약 25%에 해당되었으며 중성화 속도는 물-시멘트비 60%, R=1의 조건인 kishitani의 제안식 3.727 $\sqrt{t}$ 보다 5%가 빠른 3.92 $\sqrt{t}$로 나타났다. 콘크리트의 염화물량의 조사결과에서는 전체 측정부위의 24%가 임계염화물량을 초과하였으며 철근의 자연전위는 -350mV(vs. CSE)이하로 측정된 것이 약 31%에 해당되는 구조물로서 과다한 염화물량이 철근부식의 주요 원인이 되는 것으로 조사되었다. 자연전위 -350mV 이하인 구조물에 한한 철근부식의 주요요인을 추정한 결과, 약 60%에 해당하는 부위가 치대 허용염화물량을 초과하였기 때문으로 분석된다.