• 제목/요약/키워드: solar radiation effect

검색결과 340건 처리시간 0.022초

Temperature variation in steel beams subjected to thermal loads

  • Abid, Sallal R.
    • Steel and Composite Structures
    • /
    • 제34권6호
    • /
    • pp.819-835
    • /
    • 2020
  • The effects of atmospheric thermal loads on the response of structural elements that are exposed to open environments have been recognized by research works and design specifications. The main source of atmospheric heat is solar radiation, which dominates the variation of the temperature of air, earth surface and all exposed objects. The temperature distribution along the depth of steel members may differ with the geometry configuration, which means that the different-configuration steel members may suffer different thermally induced strains and stresses. In this research, an experimental steel beam was instrumented with many thermocouples in addition to other sensors. Surface temperatures, air temperature, solar radiation and wind speed measurements were recorded continuously for 21 summer days. Based on a finite element thermal analysis, which was verified using the experimental records, several parametric studies were directed to investigate the effect of the geometrical parameters of AISC standard steel sections on their thermal response. The results showed that the overall size of the beam, its depth and the thickness of its elements are of significant effect on vertical temperature distributions and temperature differences.

THE EFFECT OF ATMOSPHERIC SCATTERING AS INFERRED FROM THE ROCKET-BORNE UV RADIOMETER MEASUREMENTS

  • Kim, Jhoon
    • Journal of Astronomy and Space Sciences
    • /
    • 제14권1호
    • /
    • pp.87-93
    • /
    • 1997
  • Radiometers in UV and visible wavelengths were onboard the Korean Sounding Rocket(KSR)-1 and 2 which were launched on June 4th and September 1st, 1993. These radiometers were designed to capture the solar radiation during the ascending period of the rocket flight. The purpose of the instrument was to measure the vertical profiles of stratospheric ozone densities. Since the instrument measured the solar radiation from the ground to its apogee, it is possible to investigate the altitude variation of the measured intensity and to estimate the effect of atmospheric scattering by comparing the UV and visible intensity. The visible channel was a reference because the 450-nm wavelength is in the atmospheric window region, where the solar radiation is transmitted through the atmosphere without being absorbed by other atmospheric gases. The use of 450-nm channel intensity as a reference should be limited to the altitude ranges above the certain altitudes, say 20 to 25km where the signals are not perturbed by atmospheric scattering effects.

  • PDF

대기 복사 모형에 의한 남극 세종기지에서의 복사학적 특징 : 지표면에서 UV-A와 Erythemal UV-B 자외선 양 변화 (Radiative Properties at King Sejong Station in West Antarctica with the Radiative Transfer Model : A Surface UV-A and Erythemal UV-B Radiation Changes)

  • 이규태;이방용;원영인;지준범;이원학;김윤정
    • Ocean and Polar Research
    • /
    • 제25권1호
    • /
    • pp.9-20
    • /
    • 2003
  • A solar radiation model was used to investigate the UV radiation at the surface offing Sejong Station in West Antarctica. The results calculated by this model were compared with the values measured by UV-Biometer and UV-A meter during 1999-2000. In this study, the parameterization of solar radiative transfer process was based on Chou and Lee(1996). The total ozone amounts measured by Breve. Ozone Spectrophotometer and the aerosol amounts by Nakajima et al.(1996) was used as the input data of the solar radiative transfer model. And the surface albedo is assumed to be 0.20 in summer and 0.85 in winter. The sensitivity test of solar radiative transfer model was done with the variation of total ozone, aerosol amount, and surface albedo. When the cosine of solar zenith angle is 0.3, Erythemal UV-B radiation decreased 73% with the 200% increase of total ozone from 100 DU to 300 DU, but the decrease of UV-A radiation is about 1%. Also, for the same solar zenith angle, UV-A radiation was decreased 31.0% with the variation of aerosol optical thickness from 0.0 to 0.3 and Erythemal UV-B radiation was decreased only 6.1%. The increase of Erythemal W-B radiation with the variation of surface albedo was twice that of UV-A increase. The surface Erythemal UV-B and UV-A radiation calculated by solar raditive transfer model were compared with the measured values fer the relatively clear day at King Sejong Station in West Antarctica. The model calculated Erythemal UV-B radiation at the surface coincide well with the measured values except for cloudy days. But the difference between the model calculated UV-A radiation and the measured value at the surface was large because of cloud scattering effect. So, the cloud property data is needed to calculate the UV radiation more exactly at King Sejong Station in West Antarctica.

지형효과를 고려한 강원지역의 태양광 발전지도 개발 (The Development of Photovoltaic Resources Map Concerning Topographical Effect on Gangwon Region)

  • 지준범;조일성;이규태;이원학
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.37-46
    • /
    • 2011
  • The GWNU (Gangnung-Wonju national university) solar radiation model was developed with radiative transfer theory by Iqbal and it is applied the NREL (National Research Energy Laboratory). Input data were collected and accomplished from the model prediction data from RDAPS (Regional Data Assimilated Prediction Model), satellite data and ground observations. And GWNU solar model calculates not only horizontal surface but also complicated terrain surface. Also, We collected the statistical data related on photovoltaic power generation of the Korean Peninsula and analyzed about photovoltaic power efficiency of the Gangwon region. Finally, the solar energy resource and photovoltaic generation possibility map established up with 4 km, 1 km and 180 m resolution on Gangwon region based on actual equipment from Shinan solar plant,statistical data for photovoltaic and complicated topographical effect.

태양광발전원(太陽光發電原)을 고려한 전력계통(電力系統)의 확률논적(確率論的)인 신뢰도(信賴度) 평가(評價)에 관한 연구(硏究) (A Study on Probabilistic Reliability Evaluation of Power System Considering Solar Cell Generators)

  • 박정제;오량;최재석;차준민
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.486-495
    • /
    • 2009
  • This paper proposes a new methodology on reliability evaluation of a power system including solar cell generators (SCG). The SCGs using renewable energy resource such as solar radiation(SR) should be modeled as multi-state operational model because the uncertainty of the resource supply may occur an effect as same as the forced outage of generator in viewpoint of adequacy reliability of system. While a two-state model is well suited for modeling conventional generators, a multi-state model is needed to model the SCGs due to the random variation of solar radiation. This makes the method of calculating reliability evaluation indices of the SCG different from the conventional generator. After identifying the typical pattern of the SR probability distribution function(pdf) from SR actual data, this paper describes modelling, methodology and details process for reliability evaluation of the solar cell generators integrated with power system. Two test results indicate the viability of the proposed method.

하절기 복사환경 관측을 통한 수목과 일사차폐 막 구조물의 자연냉각효과 (Analysis of Passive Cooling Effect of Membrane Shading Structure and the Tree by Field Observations in the Summer)

  • 최동호;이부용
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.137-146
    • /
    • 2007
  • This study is about the passive cooling effects of three outdoor solar shading facilities as trees, pergola with wistaria vine and membrane shading structure, which are expected to provide cool spots in the summer. Field observations of measuring thermal environment of selected facilities is executed. Thermal environment measuring was categorized as short wave radiation, long wave radiation, net radiation, globe temperature, surface temperature measured by infrared camera. Heat transfer mechanism is analyzed with overall data from field measurement. Results from this study are as below; 1) Radiation balance measured on shaded surface under membrane shading structure was 17%($86W/m^2$) of the unshaded surface radiation balance($511W/m^2$). 2) Surface temperature comparison between vegetation and membrane of the shading structure is performed at 3 o'clock in the afternoon. Surface temperature of vegetation was same as air temperature and that of membrane was $5^{\circ}C$ higher than air temperature. Vegetation transpiration is considered as the causing factor which make those differences. 3) Results from this study could be used as fundamental data for reducing heat island phenomena and continuos research on this subject would be needed.

Construction and Testing of a radiation-beam powered TA (ThermoAcoustic) washer for grease removal

  • ;;김영민;오승진;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.21-28
    • /
    • 2015
  • A small washer powered directly and solely by thermal radiation was constructed and tested to explore the feasibility of using solar energy or other types of thermal radiation for washing and cleaning. In principle, TA (ThermoAcoustic) washers have the benefits of simpler design and operation and fewer energy conversion processes, thus should be more energy efficient and cost less than electric washing/cleaning systems. The prototype TA converter we constructed could sustain itself with consistent fluid oscillations for more than 20 minutes when powered by either concentrated solar radiation or an IR (infrared) heater. The frequencies of water oscillations in the wash chamber ranged from 2.6 to 3.6 Hz. The overall conversion efficiency was lower than the typical efficiencies of TA engines. Change in water temperature had little effect on the oscillatory flow in the TA washer due to its low efficiency. On the other hand higher water temperatures enhanced grease removal considerably in our tests. Methods for measuring the overall conversion efficiency, frictional loss, and grease removal of the TA washing system we designed were developed and discussed.

Temperature analysis of a long-span suspension bridge based on a time-varying solar radiation model

  • Xia, Qi;Liu, Senlin;Zhang, Jian
    • Smart Structures and Systems
    • /
    • 제25권1호
    • /
    • pp.23-35
    • /
    • 2020
  • It is important to take into account the thermal behavior in assessing the structural condition of bridges. An effective method of studying the temperature effect of long-span bridges is numerical simulation based on the solar radiation models. This study aims to develop a time-varying solar radiation model which can consider the real-time weather changes, such as a cloud cover. A statistical analysis of the long-term monitoring data is first performed, especially on the temperature data between the south and north anchors of the bridge, to confirm that temperature difference can be used to describe real-time weather changes. Second, a defect in the traditional solar radiation model is detected in the temperature field simulation, whereby the value of the turbidity coefficient tu is subjective and cannot be used to describe the weather changes in real-time. Therefore, a new solar radiation model with modified turbidity coefficient γ is first established on the temperature difference between the south and north anchors. Third, the temperature data of several days are selected for model validation, with the results showing that the simulated temperature distribution is in good agreement with the measured temperature, while the calculated results by the traditional model had minor errors because the turbidity coefficient tu is uncertainty. In addition, the vertical and transverse temperature gradient of a typical cross-section and the temperature distribution of the tower are also studied.

동계 이중외피와 내부식재에 의한 실내 온도 특성에 관한 연구 (The Characteristics of the winter season window and indoor temperature due to the indoor plant)

  • 윤영일;조주영
    • KIEAE Journal
    • /
    • 제15권5호
    • /
    • pp.107-112
    • /
    • 2015
  • Purpose: This study desires to investigate an effect of indoor temperature, humidity, and illuminance targeting a planting system of double-skin facade and cavity space adjacent to the outside within a certain period of winter. Through this, the study suggests a basic material about an energy conservation effect of double window system using planting to reduce heating load of a building in winter, so desires to contribute to indoor thermal comfort effect and illuminance correction study of double window and indoor plant. Method: Considering effects such as day and night climatic elements and air conditions in winter, illuminance measurement was conducted through a double-skin facade of space, a subject of the measurement, on the basis of practical residence time of a resident, and this study analyzed characteristics of indoor illuminance about this. The study measured and compared a change of insolation, dry-bulb temperature, and relative humidity at each indoor-outdoor measuring point, so measured and compared characteristics of an indoor temperature effect by elements of double-skin facade and indoor plant. Result: Through this study, the researcher could determine that indoor plant within double window in winter not only blocks solar radiation but also photosynthesizes, so is somewhat disadvantageous to winter thermal comfort reducing heating load. In addition, solar radiation going through interior plays a role to bring down somewhat high humidity to about 50% of reasonable humidity, so plays a direct role of maintenance of comfortable indoor space. Although there are effects such as blocking of solar radiation and temperature reduction, this has a positive influence on humidity control and proper illuminance distribution. The researcher could determine that illuminance, temperature, and humidity by solar radiation penetration for the whole measuring time play a role to supplement indoor environment mutually.

태양열 온수 시스템에 적용 가능한 100 W급 열전발전 모듈 성능에 관한 연구 (A Study on the Performance of 100 W Thermoelectric Power Generation Module for Solar Hot Water System)

  • 서호영;이경원;윤정훈;이순환
    • 한국태양에너지학회 논문집
    • /
    • 제39권1호
    • /
    • pp.21-32
    • /
    • 2019
  • Solar hot water system produces hot water using solar energy. If it is not used effectively, overheating occurs during the summer. Therefore, a lot of research is being done to solve this. This study develops thermoelectric power module applicable to solar hot water system. A thermoelectric material can directly convert thermal energy into electrical energy without additional power generation devices. If there is a temperature difference between high and low temperature, it generate power by Seebeck effect. The thermoelectric module generates electricity using temperature differences through the heat exchange of hot and cold water. The water used for cooling is heated and stored as hot water as it passes through the module. It can prevent overheating of Solar hot water system while producing power. The thermoelectric module consists of one absorption and two radiation part. There path is designed in the form of a water jacket. As a result, a temperature of the absorption part was $134.2^{\circ}C$ and the radiation part was $48.6^{\circ}C$. The temperature difference between the absorption and radiation was $85.6^{\circ}C$. Also, The Thermoelectric module produced about 122 W of irradiation at $708W/m^2$. At this time, power generation efficiency was 2.62% and hot water conversion efficiency was 62.46%.