• Title/Summary/Keyword: solar heat system

Search Result 792, Processing Time 0.027 seconds

Optimal Supply Scheme of Solar Hot Water Heating Systems for the Apartment Complexes (공동주택용 태양열 급탕시스템 최적공급 방안 해석연구)

  • Lee, Chul-Sung;Park, Ja-Son;Park, Jae-Wan;Shin, U-Cheul;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.245-250
    • /
    • 2008
  • This study is on the availability of solar thermal energy in Korean high-rise apartment complex depending on the installation type of solar collectors to roof or facade of building. Firstly, solar access evaluation on the roof and the facade of apartment buildings was carried out. The total thermal load of each apartment unit and building was investigated and matched with the energy which was produced by solar thermal systems on the facade. The considered layout patterns of apartment buildings were '一type', 'alternative 一type', 'ㄱtype' and 'ㅁtype' and that was analyzed in prior studies. Extensive dynamic hourly energy simulations with the solar thermal system were Performed with the TRNSYS of SEL. We assumed that the apartment complex is composed of 9 buildings and located in Daejeon. The collectors are the heat-pip evacuated tube collectors and the number of collectors are 45 tubes We assumed that the collectors are installed on the balcony of each unit and the angle of incilnation is $90^{\circ}$. As a result, the supply amount of solar thermal systems is about 4,850,086kJ/hr and the solar fraction is about 66%. The solar fraction according to each azimuth is about 66% on the south, 62% on the south-east $30^{\circ}$ and 56% on the south-east $60^{\circ}$. So, we quantitatively got a line on the optimal azimuth for installing the solar thermal systems. The solar fraction has differences from 5% to 15% of each floor, 6th, 12th and 20th and those tendencies are same in analyzed each 4 types of the apartment complexes.

  • PDF

Development and Evaluation of an Apparatus to Measure the Solar Heat Gain Coefficient of a Fenestration System According to KS L 9107 (KS L 9107에 의한 태양열 취득률(SHGC) 측정장치 개발 및 평가)

  • Kim, Tae-Jung;Choi, Hyun-Jung;Kang, Jae-Sick;Park, Jun-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.11
    • /
    • pp.512-521
    • /
    • 2014
  • Recently, multiple glazing units, frames, complex fenestration systems, and windows with shading devices have been developed to save cooling energy in buildings. However, very little work has been conducted on developing a direct experimental test method of the solar heat gain coefficient(SHGC) for new fenestration techniques. This study aims to develop and evaluate a test apparatus to measure the SHGC, according to the KS L 9107 test method. The performance of the solar simulator was class A, B, and A, for spectral match, non-uniformity, and instability irradiance, respectively. The differences between the measured and calculated SHGC values were found to range between 0.001 and 0.011, and for all test specimens they agreed within 4%. These results establish the validity of the test apparatus. This system is thus expected to be useful in assessing the energy performance for various types of fenestration.

Development of a New Air Cooling System Utilizing the Stirling Engine for Preventing Solar Cell from Overheating (태양광 모듈의 과열 방지용 공랭형 스털링기관 냉각 시스템 개발)

  • Kim, Hyoungeun;Park, Chanwoo;Chu, Jinkyung;Keum, Dongyeop;Park, Silro;Kim, Jeongmin;Kim, Daejin
    • Transactions of the KSME C: Technology and Education
    • /
    • v.2 no.1
    • /
    • pp.57-63
    • /
    • 2014
  • In this paper new air-cooling system utilizing Stirling engine was proposed for improving efficiency in solar photovoltaic power generation. The solar cell plate was equipped with semi-circular channel for air flow on the backside. Beta-type Stirling engine was installed on the plate and its flywheel was connected to a motor fan by a transmission belt. A forced convective air flow for heat radiation was generated by the operation of the self-starting Stirling engine. The performance tests for power generation of solar cell with or without the proposed air-cooling system were conducted under halogen lamp. From the experimental results, it was found that decline in output voltage of the solar cell with proposed cooling system was 25% less than that of the solar cell without cooling system.

Research on the Performance of a Solar Air Conditioning System using a Liquid Desiccant in Summer (액체흡수제 이용 태양열 공조시스템의 하계 능력에 관한 연구)

  • Choi, K.H.;Yoon, J.I.;Kim, B.C.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.2
    • /
    • pp.33-38
    • /
    • 2002
  • In order to find out whether solar air conditioning system could be applied to building or not, the performance and evaluation on thermal environment of the system suggested was done during summer. A solar model house was constructed to find out the performance and thermal environment evaluation when it actually operated outside. As a result, regeneration rate increased rapidly when LiCl solution temperature was over $50^{\circ}C$ and the regeneration rate was $13\sim15kg$ during 9 hours operation. Furthermore the dehumidification rate was 12kg at maximum during 10 hours operating of a dehumidifier and indoor temperature and relative humidity was $28.4^{\circ}C$ and 39.1% in average respectively. On evaluation of thermal environment during summer, PMV value was slightly high, but thermal sensation vote was 71% within the comfort zone.

Characterization of Selectively Absorbing Properties of Indium Tin Oxide Thin Films by UV-VIS-IR Spectroscopy (UV-VIS-IR 분광법에 의한 산화 인듐 주석 박막의 선택적 투과 흡수 특성 관찰)

  • Lee, Jeon-Kook;Lee, Dong-Heon;Cho, Nam-Hee
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.135-142
    • /
    • 1992
  • Indium tin oxide(ITO) films coated on the window glass selectively transmit the solar energy and infrared. We call this system passive solar collectors. Selectively absorbing properties of sol gel dip coated ITO films were characterized by UV-VIS-NIR spectroscopy. The effects of heat treating temperature, time, atmosphere, substrate and barrier layers are concerned. Indium tin oxide films heat-treated at $500^{\circ}C$ in a reducing atmosphere show intrinsic properties. Efficiency of solar energy transmittance was enhanced by coating of $SiO_2-ZrO_2$ as an alkali ion barrier layer. Energy was saved by the double layers of $SiO_2-ZrO_2$ and ITO since solar energy is transmitted and heat generated inside(${\lambda}$ > 2700nm) is reflected.

  • PDF

A Study on the Heat Storage System for Chemical Heat Pump Using Inorganic Hydrates(I) - Heat Storage Characteristics - (화학열펌프에 있어서의 무기수화물계 축열시스템에 관한 연구(I) - 탈수 축열 성능연구 -)

  • Park, Young-Hae;Kim, Jong-Shik
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.29-38
    • /
    • 1995
  • The heat-storage characteristics accompanied by exothermic reaction at the regeneration of $Ca(OH)_2$ in tile heat-storage mode of a chemical heat pump system using a $Ca(OH)_2/CaO$ reversible thermochemical reaction was examined in a lab-scale unit. In this heat-storage mode, the particle bed of CaO could be regenerated by heating the $Ca(OH)_2$ packed bed to the higher temperature at which the equilibrium pressure in the reactor is greater than the water vapor pressure in the condenser. The results are i) the dehydration, thermal decomposition, rate of $Ca(OH)_2$ was higher at the lower part of particle bed than at the upper part, ii) in the reactor, the dehydration was proceeded along radial and axial direction, from inner part to the outer part, which explains heat transfers from the center to wall and from the tenter to lower or upper part of reactor.

  • PDF

A development of solar hot water system for anchovy proceeding (멸치가공을 위한 태양열 온수기 개발)

  • Kong, T.W.;Ji, M.K.;Lee, Y.H.;Chung, H.S.;Jeong, H.M.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.671-676
    • /
    • 2001
  • This study are development results of solar hot water system for anchovy proceeding. The heat amounts of boiling vessel are calculated 292.66W at forward and backward direction, and surface direction are calculated 373.14W. The polyenoic rate of anchovy are measured lower as high temperature, but monoenoic and polyacid are higher. Then the others. The maximum radiation of anchovy fishing grounds are shown $350kcal/m^2h$ at pm. 13:00, Chungdo in CHINA. Distributions of Velocity and temperature in boiling vessel are calculation. Solar collector and boiling vessel for anchovy proceeding ship are developed to automatic control system.

  • PDF

Solar Energy Utilization in a Greenhouse Bulk Curing and Drying System. (II) (Greenhouse Bulk 건조기에 의한 태양열이용에 관한 연구 (제2보))

  • 이철환;변주섭
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.5 no.1
    • /
    • pp.79-85
    • /
    • 1983
  • The greenhouse bulk curing and drying system utilization of the direct solar energy was tested to evaluate that how much fuel could be saved for curing flue-cured tobacco at the Dae Gu Experiment Station (North latitude : $35^{\circ}$49'), in 1979-1982. The air temperature and total radiation were 19.0 to 38.5$^{\circ}C$ and 1311.0 to 1412.7 cal/$\textrm{cm}^2$/day during the 4 replicated curing test, respectively. The greenhouse bulk curing and drying system was able to cut fuel consumption by 32% compared with the conventional bulk curing barn. We could obtain almost same utilization efficiency of solar energy in 1982 compare with normal year, mainly increasing the heat receiving area.

  • PDF

Performance Characteristics of the Desiccant Cooling System in Various Outdoor and Load Conditions (외기조건에 따른 제습냉방시스템의 성능 특성)

  • Lee, Dae-Young;Chang, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.623-628
    • /
    • 2009
  • Desiccant based air conditioning system offers a promising alternative to conventional one using vapour compression refrigeration for energy saving and greenhouse gas reduction. It is a heat driven cycle which has high potential for the use of low grade heat source such as the waste heat from the cogeneration plant or the solar thermal energy. In this study, the cooling performance of a desiccant cooling system incorporating a regenerative evaporative cooler was characterized in various operation conditions through numerical simulation. The cooling capacity and COP were evaluated at various outdoor conditions, regeneration temperatures, and supply flow rates. Based on the performance characteristics, the optimal control scheme was discussed to minimize the cooling cost at part load condition.

  • PDF