• Title/Summary/Keyword: solar diffuser

Search Result 31, Processing Time 0.026 seconds

An Experimental Study on Heat Flow Characteristics of Inflowing Cool Air in the Room (실내(室內) 유입(流入) 냉기(冷氣)의 열유동(熱流動) 특성(特性)에 관한 실험적(實驗的) 연구(硏究))

  • Jang, Y.G.;Pak, J.W.;Pak, E.T.
    • Solar Energy
    • /
    • v.18 no.1
    • /
    • pp.57-67
    • /
    • 1998
  • A study on a buoyancy effect by the temperature difference between a inner room air and a inflowing cool air and also by Inlet velocity can contribute greatly to enhance performance of air conditioning system, so the study on the distribution characteristics of inflowed cool air is important to analyze the cool air storage in a room. For this study, in the real-sized model room, the temperature differences between inflowing cool air and inner room air are 10, 20, $30^{\circ}C$, and the inlet velocities of inflowing cool air are 1, 2, 3m/s respectively as dynamic parameters. Also, a anemos and a vane type diffuser are used as inlet geometric conditions. Following conclusions have been obtained through this study. 1) In case of the anemos type diffuser, it is found that a dimensionless temperature profile is low and the distribution of the inflowed cool air is uniform. and also, all diffuusers have a low temperature of the inner room as increasing the inlet velocity. 2) A mixing takes place rapidly in case of the anemos type diffuser when the temperature difference is low ${\Delta}T=10^{\circ}C$ and the inletvelocity is high V=3m/s. and the mixing degree is higher with the anemos type diffuser than the vane.

  • PDF

Thermal Stratification Effects Near an Interface by Horizontal Inflow of Cold Water in Thermal Storage Tank (냉수가 수평유입되는 열저장탱크의 중간 경계면 부근에서의 열성층 효과)

  • Hwang, Sung-Il;Pak, Ee-Tong
    • Solar Energy
    • /
    • v.8 no.2
    • /
    • pp.46-56
    • /
    • 1988
  • This investigation concerns thermal stratification of the water due to the temperature difference (${\Delta}T=T_{\infty}-T_i$) between the mean temperature of the water in the test tank (1m wide, 1m high, 2.1m long) and the temperature of the inflow water into the tank; flow rate of circulating water and height of the sink diffuser in the test tank. The additional objectives was to observe a stratification phenomena near an interface by measuring the velosities and the temperature difference and investigate an availabilities of the better effective hot water through establishing thermocline near an interface around the bottom of the tank. Following results were obtained through the experiments. 1. When the flow rate was constant and the temperature difference (${\Delta}T=T_{\infty}-T_i$) between the mean temperature of the flow in the test tank and the temperature of the inflow water increased by 5.6, 9.5, 13.5($^{\circ}C$), obtained the better effective advantage of hot water and the stress near an interface increased gradually. 2. When the ${\Delta}T=T_{\infty}-T_i$ was constant and flow rate increased by 4.0, 4.8, 6.4, 8.0 (LPM), obtained the better effective advent age of hot water and the mean stress near an interface increased gradually. 3. When the height of the sink diffuser was 25cm from tank bottom in comparison with 50cm, obtained the better effective advantage of hot water and the mean stress near an interface increased.

  • PDF

Prediction of Stratification Model for Diffusers in Underfloor Air Distribution System using the CFD (CFD를 활용한 바닥공조시스템 디퓨저의 성층화 모델 예측)

  • Son, Jeong-Eun;Yu, Byeong-Ho;Pang, Seung-Ki;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.105-110
    • /
    • 2017
  • Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings. UFAD systems use the underfloor plenum beneath a raised access floor to provide conditioned air through floor diffusers that create a vertical thermal stratification during cooling operations. Thermal stratification has significant effects on energy, indoor air quality, and thermal comfort performance. The purpose of this study was to characterize the influence of a linear bar grille diffuser on thermal stratification in both interior and perimeter zones by developing Gamma-Phi based prediction models. Forty-eight simulations were carried out using a Computational Fluid Dynamics (CFD) technique. The number of diffusers, the air flow supply, internal heat gains, and solar radiations varied among the different cases. Models to predict temperature stratification for the tested linear bar grille diffuser have been developed, which can be directly implemented into dynamic whole-building simulation software such as EnergyPlus.

Experimental Evaluation of a Fiber Optic Concentrator for Daylighting (실내조명용 화이버 광학 집광기의 성능에 관한 실험적 평가)

  • Han, Hyun-Joo;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.27-34
    • /
    • 2008
  • A series of outdoor tests were conducted on a fiber optic solar concentrator system for its performance on daylighting. The system is comprised of four main components - a parabolic dish reflector, a convex mirror, a homogenizer tube and an optical fiber cable. Results show that the system could be successfully applied for indoor lighting if some improvements are made for light transmiting (optical) cables. A maximum concentration ratio of 90 was observed delivering the illuminance of 4,800 lux at a distance of 1.2m from the diffuser for the outdoor illuminance of 102,100 lux.

Analysis of the ejector for low-pressure evaporative desalination system using solar energy (태양에너지 이용 저압 증발식 해수 담수시스템 이젝터 CFD 해석)

  • Hwang, In-Seon;Joo, Hong-Jin;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.137-143
    • /
    • 2010
  • In this study, the ejector design was modeled using Fluent 6.3 of FVM(Finite Volume Method) CFD(Computational Fluid Dynamics) techniques to resolve the flow dynamics in the ejector. A vacuum system with the ejector has been widely used because of its simple construction and easy maintenance. Ejector is the main part of the desalination system, of which designs determine the efficiency of system. The effects of the ejector was investigated geometry and the operating conditions in the hydraulic characteristics. The ejector consists mainly of a nozzle, suction chamber, mixing tube(throat), diffuser and draft tube. Liquid is supplied to the ejector nozzle, the fast liquid jet produced by the nozzle entrains and the non condensable gas was sucked into the mixing tube. In the present study, the multiphase CFD modeling was carried out to determine the hydrodynamic characteristics of seawater-air ejector. Two-dimensional geometry was considered with the quadrilateral-mashing scheme. The gas suction rate increases with increasing Motive flow circulating rate.

A Study on Thermally Stratied Hot Water Storage Tank in A Solar Heating System (태양열 난방 시스템에 적용되는 축열조의 성층화에 관한 연구)

  • Hong, Hi-Ki;Kim, Hyo-Kyung
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.1
    • /
    • pp.87-96
    • /
    • 1986
  • An experiment on the devices that enchance the stratification of storage tanks in a solar heat ins system has been carried out. The benefits of thermal stratification in sensible heat storage are to increase the system performance such as the collector efficiency or the fraction of the total load supplied by solar energy. Using the diffuser and the distributor as the stratification enchancement device, the expeliments were perfomed in the different condition of diameter and material of the distributor. As a result of experiments, there exists the diameter of distributor in which the stratification is made maximum under certain design and operation condition. Also it was identified that the kind of distributor material influenced the degree of stratification. Comparing the experimental result to the computational results calculated under the same conditions, the node number N(stratification index) was determined. The results of computer simulation that was performed about the actual solar heating system in Seoul for 24 hours show the relative advantage of stratified over well-mixed storage and the significant improvements in system performance.

  • PDF

A Computational Analysis on Candela Distribution Curves and Performance Prediction of a Fiber Optic Dish Daylighting System by Photopia (Photopia를 이용한 추적식 디쉬형 집광기의 배광분포 분석 및 자연채광 성능 예측)

  • Oh, Seung-Jin;Han, Hyun-Joo;Jeon, Young-Il;Chun, Won-Gee
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.104-113
    • /
    • 2012
  • A set of candela distribution curves(CDCs) were generated for a fiber optic dish daylighting system by Photopia under clear sky conditions at different solar altitudes. The candela distribution curves were then exported to Radiance for photometric analysis of a windowless lecture room. Observations were made on the Radiance rendered illuminance images, which provided photo realistic scenes varying with solar altitudes. If no tracking error were assumed, the daylight collection efficiency of the system remained at a constant value of 68.4% during its operation. Higher the solar altitude angle, greater in photometric quantities were observed, which are represented by candela(cd) and total lumens(lm). In all cases considered, however, the angle of light distribution remained fixed reflecting the solar tracking feature of the system. The illuminance uniformity on the workplane lingered around 0.12, which is quite low. This is quite a contrast to its average value of 0.68 of the $2.7m^2$ area directly below the terminal device (diffuser) of the system. The maximum illuminance of 1,340lux was obtained at a solar altitude of 80 degrees.

A Study on the Heat Flow Characteristics and High Efficiency Thermal Storage of Inflowing Warm Air in the Room (실내유입온기의 열유동특성과 고효율 축열에 관한 연구)

  • Pak, Ee-Tong;Jeong, Un-Chul;Lee, Do-Young
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.13-22
    • /
    • 1997
  • A study on the distribution characteristics of inflowed warm air is important to analyze warm air storage in a room. Also, in point of energy saving during heating, warm air flow characteristics occurred by circulation and distribution of inflowed warm air should be analyzed, and the storage efficiency should be considered in order to increase efficiency of heating system. For this study, in the real-sized model room, the temperature differences between inflowing warm air and inner room air are 10, 20, $30^{\circ}C$(3steps), and the flow rates of inflowing warm air are 0.5, 1, 2, 3m/s(4steps) respectively as dynamic parameters. Also, anemos and vane diffuser are used as inlet geometric condition. Consequently, on geometric conditions, high thermal storage efficiency can be obtained with the vane diffuser, and heat flow characteristics depend on the inflowing velocity more than reference temperature difference.

  • PDF

Analysis of the Water Temperature Stratification-Maintaining Conditions Using CFD in Case of Intake of Deep, Low-Temperature Water (댐의 심층저온수 취수시 수온 성층화 유지 조건에 대한 CFD를 이용한 분석)

  • Lee, Jin-Sung;Cho, Soo;Sim, Kyung-Jong;Jang, Moon-Soung;Sohn, Jang-Yeul
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.2
    • /
    • pp.31-38
    • /
    • 2009
  • This study was conducted to forecast inner water temperature strata change by extracting deep water from a dam. For the methodology, the scope wherein the balance between the volume of low-temperature water intake through the virtual water intake opening as installed within the stored water area and the volume of water intake from the surrounding area is not destroyed was calculated through the CFD simulation technique using the computational fluid dynamics(CFD) interpretation method. This study suggested a supplementary method(diffuser) to avoid destroying the water temperature strata, and the effect was reviewed. In case of intake of the same volume, when the velocity of flow of water intake is reduced by increasing the pipe diameter, the destruction of water temperature strata can be minimized. When the area(height) where the intake of water is possible is low, a diffuser for interrupting the vertical direction inflow should be installed to secure favorable water intake conditions in case of water intake on the upper part. This study showed that there was no problem if the intake-enabled, low-temperature area was secured approximately 10m from the bottom when the scope that does not destroy the water temperature strata in case of water intake was forecast using the regression formula.

Development of the GOCI Radiometric Calibration S/W (정지궤도 해양위성(GOCI) 복사보정 S/W 개발)

  • Cho, Seong-Ick;Ahn, Yu-Hwan;Han, Hee-Jeong;Ryu, Joo-Hyung
    • Proceedings of the KSRS Conference
    • /
    • 2009.03a
    • /
    • pp.167-171
    • /
    • 2009
  • 정지궤도에서는 세계 최초의 해양관측위성으로 개발된 정지궤도 해양위성(GOCI, Geostationary Ocean Color Imager)은 통신해양기상위성(COMS, Communication, Ocean and Meterological Satellite)의 탑재체로서 2009년말 발사 예정이다. 정지궤도 해양위성의 복사보정은 센서의 전기적 특성에 의한 잡음을 제거하기 위한 암흑전류 교정(Dark Current Correction)을 먼저 수행한 다음, 주운영지상국인 해양위성센터(KOSC, Korea Ocean Satellite Center)에서 수신된 위성의 원시자료의 Digital Number(DN)를 실제 해양원격탐사에서 이용하는 물리량인 복사휘도(Radiance, $W/m^2/{\mu}m/sr$)로 변환하는 복사보정을 수행한다. 정확도 높은 복사보정을 수행하기 위해서는 기준광원의 복사휘도와 센서의 물리적 특성을 정확하게 알아야 한다. 정지궤도 해양위성 궤도상 복사보정(on-orbit radiometric calibration)에서는 태양이 기준광원이기 때문에, 기준 태양복사모델(Thuillier 2004 Solar Irradiance Model)에서 지구-태양간 거리 변화(1년 주기)를 보정한 태양의 방사도 (Irradiance)를 이용하고, 태양입사각에 대한 태양광 확산기의 감쇄 특성 변화를 고려하여 센서에 입력되는 복사휘도를 계산한다. 센서의 물리적 특성으로 인한 복사보정의 오차를 줄이기 위해 우주방사선 및 우주먼지(space debris)로 인해 위성 운용기간 중 그 특성이 저하되는 태양광 확산기(solar Diffuser)의 특성변화를 모니터링하기 위한 DAMD(Diffuser Aging Monitoring Device)를 이용한다. 정지궤도 해양위성 주관운영기관인 한국해양연구원의 해양위성센터에서는 정지궤도 해양위성 복사보정을 수행하기 위한 S/W를 통신해양기상위성 자료처리시스템 개발사업의 일환으로 개발하였으며, 관련 성능 시험을 수행하고 있다.

  • PDF