• Title/Summary/Keyword: solar absorption efficiency

Search Result 215, Processing Time 0.025 seconds

Viologen Based All-in-one Flexible Electrochromic Devices (바이올로진 기반의 일체형 유연 전기변색소자)

  • Park, Bo-Seong;Kim, Hyun-Jeong;Shin, Hyeonho;Park, Seongmin;Lee, Jaeun;Jeon, Sunggun;Nah, Yoon-Chae
    • Korean Journal of Materials Research
    • /
    • v.31 no.3
    • /
    • pp.132-138
    • /
    • 2021
  • Electrochromic devices (ECDs) have been drawing great attention due to their high color contrast, low power consumption, and memory effect, and can be used in smart windows, automatic dimming mirrors, and information display devices. As with other electronic devices such as LEDs (light emitting diodes), solar cells, and transistors, the mechanical flexibility of ECDs is one of the most important issue for their potential applications. In this paper, we report on flexible ECDs (f-ECDs) fabricated using an all-in-one EC gel, which is a mixture of electrolyte and EC material. The f-ECDs are compared with rigid ECDs (r-ECDs) on ITO glass substrate in terms of color contrast, coloration efficiency, and switching speed. It is confirmed that the f-ECDs embedding all-in-one gel show strong blue absorption and have competitive EC performance. Repetitive bending tests show a degradation of electrochromic performance, which must be improved using an optimized device fabrication process.

Synthesis and Photovoltaic Properties of Alternating Conjugated Polymers Derived from Thiophene-Benzothiadiazole Block and Fluorene/Indenofluorene Units

  • Li, Jianfeng;Tong, Junfeng;Zhang, Peng;Yang, Chunyan;Chen, Dejia;Zhu, Yuancheng;Xia, Yangjun;Fan, Duowang
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.2
    • /
    • pp.505-512
    • /
    • 2014
  • A new donor-accepter-donor-accepter-donor (D-A-D-A-D) type 2,1,3-benzothiadiazole-thiophene-based acceptor unit 2,5-di(4-(5-bromo-4-octylthiophen-2-yl)-2,1,3-benzothiadiazol-7-yl)thiophene ($DTBTTBr_2$) was synthesized. Copolymerized with fluorene and indeno[1,2-b]fluorene electron-rich moieties, two alternating narrow band gap (NBG) copolymers PF-DTBTT and PIF-DTBTT were prepared. And two copolymers exhibit broad and strong absorption in the range of 300-700 nm with optical band gap of about 1.75 eV. The highest occupied molecular orbital (HOMO) energy levels vary between -5.43 and -5.52 eV and the lowest unoccupied molecular orbital (LUMO) energy levels range from -3.64 to -3.77 eV. Potential applications of the copolymers as electron donor material and $PC_{71}BM$ ([6,6]-phenyl-$C_{71}$ butyric acid methyl ester) as electron acceptors were investigated for photovoltaic solar cells (PSCs). Photovoltaic performances based on the blend of PF-DTBTT/$PC_{71}BM$ (w:w; 1:2) and PIF-DTBTT/$PC_{71}BM$ (w:w; 1:2) with devices configuration as ITO/PEDOT: PSS/blend/Ca/Al, show an incident photon-to-current conversion efficiency (IPCE) of 2.34% and 2.56% with the open circuit voltage ($V_{oc}$) of 0.87 V and 0.90 V, short circuit current density ($J_{sc}$) of $6.02mA/cm^2$ and $6.12mA/cm^2$ under an AM1.5 simulator ($100mA/cm^2$). The photocurrent responses exhibit the onset wavelength extending up to 720 nm. These results indicate that the resulted narrow band gap copolymers are viable electron donor materials for polymer solar cells.

Comparisons in Volumes of Irrigation and Drainage, Plant Growth and Fruit Yield under FDR Sensor-, Integrated Solar Radiation-, and Timer-Automated Irrigation Systems for Production of Tomato in a Coir Substrate Hydroponic System (토마토 코이어 수경재배에서 FDR센서, 적산일사량센서 및 타이머 급액방식에 따른 급배액량, 생육 및 과실수량 비교)

  • Choi, Eun-Young;Kim, Hee-Yong;Choi, Ki-Young;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.25 no.1
    • /
    • pp.63-70
    • /
    • 2016
  • Water drainage from the open hydroponics often causes significant environmental pollution due to agrochemicals and loss of water and nutrients. The objectives of this study were to show the potential application of an irrigation schedule based on threshold values of volumetric substrate water content for tomato (Solanum lycopersicum L. 'Samsamgu') cultivation in a commercial hydroponic farm during spring to summer cultivation. This study was performed for minimizing effluent from coir substrate hydroponics using a frequency domain reflectometry (FDR) sensor-automated irrigation, as compared with an integrated solar-radiation (IR) and conventional timer-irrigation (TIMER) after transplanting. In results, no significant difference in daily irrigation volume was found among the treatments until 88 days after transplant (DAT). However, during the 88 to 107 DAT, the daily irrigation volume was in the order of IR (2125 mL) > TIMER (2063 mL) > FDR (1983 mL), and during the 108 to 120 DAT, it was in the order of IR (2000 mL) > TIMER (1664 mL) > FDR (1500 mL). The lowest drainage volume was observed in the FDR treatment with the order of IR (12~19%) > TIMER (4~12%) > FDR (0~7%) during the entire growing period. A lower irrigation volume in the FDR treatment after 88 DAT may be due to the sensor's detecting capacity for less water absorption by plant after completing fruit maturity with apical pruning and removal of lower leaves, while a higher irrigation volume in the IR treatment may be due to gradual increase in integrated solar-radiation amount as closer to summer season. There was no significant difference in plant growth and fruit yield among the treatments; however, a 11% and 18% of higher soluble sugar content was observed in the FDR than that of TIMER and IR treatment. respectively.

Nitrogen Balance in Paddy Soil of Control-Release Fertilizer Application (완효성비료 시용 논 토양중의 질소행동에 관한 연구)

  • Lee, Kyeong-Bo;Park, Chan-Won;Park, Kwang-Lai;Kim, Jong-Gu;Lee, Deog-Bae;Kim, Jae-Duk
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.3
    • /
    • pp.157-163
    • /
    • 2005
  • The increasing of greenhouse gases may change agricultural environment. The agronomic productivity will depend upon change of temperature, precipitation, solar radiation and fertilization. Particularly, nitrogen fertilization considerably influences rice productivity and agricultural environments. This experiment was conducted to study transformation of nitrogen and to determine the primary yield components responsible for yield differences in paddy soil. $NH_4-N$ concentration of NPK plot in surface water of paddy soil was $2.07mg\;L^{-1}$ at 5 days after transplanting, and then was decreased sharply due to rice absorption and loss to environment. $NO_3-N$ concentration of NPK plot in surface water was $3.97mg\;L^{-1}$ at 10 days after transplanting. $NO_3-N$ concentration range of CRF plot in surface water was $3-5mg\;L^{-1}$ at 30th after transplanting. The accumulation of $NH_3$ volatilization in NPK plot was $22.39kg\;ha^{-1}$, which accounted for 20% of N fertilizer applied but using of CRF fertilizer can reduce $NH_3$ volatilization by 67% in paddy soil. Use efficiency of N fertilizer was not different between CRF70% and CRF100% plot. Rate of N use efficiency were 27.4%, 51.2%, 49.0% in paddy field NPK, CRF70% and CRF100% plots respectively. The yield of CRF70% showed the best effect with 9.3% increase production ratio, compare with NPK plot.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 - (공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰-)

  • Choi, Yong-Don;Kang, Yong-Tae;Kim, Nae-Hyun;Kim, Man-Hoe;Park, Kyoung-Kuhn;Park, Byung-Yoon;Park, Jin-Chul;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.