• 제목/요약/키워드: soft-start

Search Result 92, Processing Time 0.024 seconds

Electronic Ballast with Modified Valley fill and Charge Pump Capacitor for Prolonged Filaments Preheating and Power Factor Correction (변형된 벨리필 구조와 전하펌프 커패시터가 결합되어 필라멘트 예열기능과 역률개선능력을 가진 형광등용 전자식 안정기)

  • Chae, Gyun;Ryoo, Tae-Ha;Cho, Gyu-Hyeong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2798-2800
    • /
    • 1999
  • A new circuit, modified valley fill (MVF) combined with resonant inductor of the self-excited resonant inverter and charge pump capacitors(CPCs), is presented to achieve high PF electronic ballast providing sufficient preheat current to lamp filaments for soft start maintaining low DC bus voltage. The MVF can adjust the valley voltage higher than half the peak line voltage. The CPCs draw the current from the input line to make up the current waveform during the valley interval. The measured PF and THD are 0.99 and 12%, respectively. The lamp current CF is also acceptable in the proposed circuit. The proposed circuit is suitable for implementing cost-effective electronic ballast.

  • PDF

Development of Dimming control system for 400W Metal Halide Lamp by Electronic Ballast and Power Line Modem (전력선모뎀 및 조광제어 안정기를 이용한 400W Metal Halide Lamp의 조광제어 시스템 개발)

  • Park, Chong-Yeon;Choi, Wang-Seop
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.193-198
    • /
    • 2009
  • In this paper, we developed remote dimming control system of electronic ballast for 400W metal halide lamp. This ballast could limit ignition current and soft start-up technique by the inverter with LCsCp resonance tank. The dimming circuit can dim from 400W to 200W by varying of the inverter switching frequency. The PLM consists of coupling circuit, BPF(Band-Pass Filter), FSK(Frequency Shift Keying) Modem and ${\mu}$-controller(Micro Controller). By coupling electronic ballast with PLM, the system that able to dimming the lamp through PLM is demonstrated by experimental results.

  • PDF

A Design of Battery Charger using Phase-Lock technique (Phase-Lock 기법을 이용한 Battery 충전기 설계)

  • Song, Eui-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.456-458
    • /
    • 1997
  • The phase-lock technique is applied to a three-phase semi-bridge type battery charger system. Using an inner fast dynamic loop, the phase-locked voltage control (PLVC) technique of three-phase semi-bridge converter is proposed to give a frequency synchronism and to reduce the subharmonics due to the unbalance of transformer or power line. To protect the power devices, the two stage soft-start, function with softly locking the phase and softly increasing the current is presented. As limiting the reference voltage of the inner voltage control loop, muti-lock phenomena are removed on the PLVC loop. A current limit function is also proposed to limit the current of battery and converter. The proposed controller is confirmed through experiment results.

  • PDF

Isolated Boost Converter with Bidirectional Operation for Supercapacitor Applications

  • Hernandez, Juan C.;Mira, Maria C.;Sen, Gokhan;Thomsen, Ole C.;Andersen, Michael A.E.
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.507-515
    • /
    • 2013
  • This paper presents an isolated bidirectional dc/dc converter based on primary parallel isolated boost converter (PPIBC). This topology is an efficient solution in low voltage high power applications due to its ability to handle high currents in the low voltage side. In this paper, the converter has been modeled using non-ideal components and operated without any additional circuitry for startup using a digital soft-start procedure. Simulated and measured loop gains have been compared for the validity of the model. On-the-fly current direction change has been achieved with a prototype interconnecting two battery banks. A second prototype has been constructed and tested for supercapacitor operation in constant power charge mode.

The Efficiency Improvement of Flocculation Facilities in Water Treatment Plants (정수장 응집설비의 효율증대 방안연구)

  • Jeon, Bok-Su;Lee, Eun-Woong;Lim, Su-Saemg;Choi, Jae-Young;Kim, Hong-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.952-954
    • /
    • 2000
  • In the cleaning-water treatment process, the flocculation machine is operated by the V.S motor when the coagulation-facility of the coagulation-process is operated. But after the flocculation machine is stopped by an instantaneous power failure, the transient takes place when the coagulation facility is re-started. To improve the transient state, we developed the reinforcement-circuit which had the function of soft-start and adapted to the field. As a result of this study, we reduced the damage of facilities and had the safety in maintaining the quality of water and improved the efficiency in the maintenance and the management.

  • PDF

Primary Current Generation for a Contactless Power Transfer System Using Free Oscillation and Energy Injection Control

  • Li, Hao Leo;Hu, Aiguo Patrick;Covic, Grant Anthony
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.256-263
    • /
    • 2011
  • This paper utilizes free oscillation and energy injection principles to generate and control the high frequency current in the primary track of a contactless power transfer system. Here the primary power inverter maintains natural resonance while ensuring near constant current magnitude in the primary track as required for multiple independent loads. Such energy injection controllers exhibit low switching frequency and achieve ZCS (Zero Current Switching) by detecting the high frequency current, thus the switching stress, power losses and EMI of the inverter are low. An example full bridge topology is investigated for a contactless power transfer system with multiple pickups. Theoretical analysis, simulation and experimental results show that the proposed system has a fast and smooth start-up transient response. The output track current is fully controllable with a sufficiently good waveform for contactless power transfer applications.

A study of polymerization shrinkage of composite resins cured by various light intensities

  • Lim, Mi-Young;Hong, Chan-Ui
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.613-613
    • /
    • 2003
  • The purpose of this study was to compare the effect of exponential curing method with conventional curing and two step soft start curing method on polymerization shrinkage of composite resins. Three brands of composite resins (Synergy Duo Shade, Z-250, Supreme) and three brands of light curing units (Spectrum 800, Elipar Highlight, Elipar Trillight) were used. In this study, the diameter of specimen was 5.5mm and height 1.6mm and the specimen was cured for 40 seconds. The shrinkage was measured by custom made linometer. The amount of linear polymerization shrinkage recorded in the computer every 0.5 second for 90 seconds. Each group was measured 10 times.(omitted)

  • PDF

Development of the Inverter System with UPS Function for the Air-Conditioning Blower (UPS 기능을 갖는 A/C Blower용 Inverter 시스템 개발)

  • Lim, Seung-Beom;Lee, Yun-Ha;Ji, Jun-Keun;Mok, Hyung-Soo;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.345-346
    • /
    • 2010
  • The HVAC(Heating Ventilation and Air Conditioning) system is only controlled by turn on/turn off operations against to AC 380V input. Therefore, the efficiency of the system is reduced and noise occurs. Also, the blower is shut down at the AC power failure. In this paper, the inverter system with UPS function for the A/C(Air Conditioning) blower is proposed. Proposed inverter system which is powered from the AC and DC voltage can control speed, operation mode, and soft-start time using CAN communication. In case of the CAN communication failure, RS-232 communication could be used to control the hardware directly by the engineer that can solve existing problems. To verify the validity of proposed inverter system, simulations and experiments are carried out.

  • PDF

Soft-Start Method of Three Phase AC/DC converter for DC Distribution System Using Sliding Mode Controller. (슬라이딩 모드 제어기를 이용한 직류(DC)배전용 3상 AC/DC컨버터의 소프트 스타트 운전기법)

  • Park, Hyeon Woo;Shin, Soo Cheol;Eom, Ju Kyoung;Lee, Taeck Kie;Lee, Kyung Ho;Won, Chung Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.186-187
    • /
    • 2010
  • 최근 직류 출력을 갖는 분산전원 시스템의 증가와 높은 에너지 변환효율을 갖는 직류(DC) 배전 시스템에 대한 관심이 증가하고 있다. 직류(DC) 배전을 빌딩에 적용하기 위해서는 계통연계형 AC/DC 컨버터가 필수적이다. 빌딩용 직류(DC)배전 시스템에서는 다양한 부하들이 상시 대용량의 AC/DC 컨버터에 연결되어 있기 때문에 컨버터의 기동시 과도상태를 최소화한 안정적인 DC전압 확보가 필수적이다. 본 논문에서는 외부 파라미터 변화나 외란에 대한 강인한 성능을 가지는 슬라이딩 모드 제어기를 사용하여 3상 AC/DC 컨버터의 초기 운전 시 발생할 수 있는 DC전압의 오버슈트 저감을 시뮬레이션에 의해 검증하였다.

  • PDF

Analysis of Forefoot Bending Angle in Sprint Spikes According to Bobsleigh Start Lap Time for Development of Korean-Specific Bobsledding Shoes

  • Park, Seungbum;Lee, Kyungdeuk;Kim, Daewoong;Yoo, Junghyeon;Jung, Jaemin;Park, Kyunghwan;Park, Sungwon;Kim, Jinhoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.3
    • /
    • pp.315-321
    • /
    • 2016
  • Objective: The aim of this study was to analyze effects of the toe-spring angle of bobsleigh shoes on start speed lap time to develop Korean-specific bobsled shoes suitable for winter environments and for domestic players on the basis of sports science and optimized biomechanical performance. Method: Seven Korean bobsleigh athletes participated in this study, with three pairs of sprint spikes from three companies (Type A, Type B, Type C). To analyze sprint lap time and forefoot bending angle for each shoe, participants were instructed to drag a sled 15 meters from the start line at a maximum sprint. forefoot bending angle was collected by a high speed camera, and lap time speed was measured. Results: Lap time for type B shoes was $3.52{\pm}0.17sec$, type A was $3.55{\pm}0.19sec$, and type C was $3.56{\pm}0.18sec$. Forefoot bending angles were: angle 1, $6.88{\pm}5.55^{\circ}$; angle 2, $9.23{\pm}6.38^{\circ}$; angle 3, $15.56{\pm}5.39^{\circ}$; angle 4, $9.54{\pm}3.85^{\circ}$; angle 5, $9.22{\pm}5.08^{\circ}$; angle 6, $7.66{\pm}6.44^{\circ}$; and angle 7, $4.30{\pm}6.24^{\circ}$ (p<.001). Forefoot bending in angle 3 was as follows: type A, $16.47{\pm}6.01^{\circ}$; type B, $14.30{\pm}4.96^{\circ}$; and type C, $15.90{\pm}5.17^{\circ}$. Conclusion: Hard outsoles and midsoles are better than soft type for reduced start lap time when developing a prototype Korean bobsled shoe.