• Title/Summary/Keyword: soft frequency operation

Search Result 138, Processing Time 0.03 seconds

Soft Start System of Induction Motor using Emergency Generator (비상 발전기를 이용한 유도전동기의 소프트 기동 시스템)

  • Hwangbo, Chan;Ko, Jae-Ha;Lee, Jung-Hwan;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.433-441
    • /
    • 2022
  • In general, in an emergency generator system for an electric facility including an induction motor load, an emergency power generation facility larger than the facility load capacity is built due to the initial starting current of the induction motor. In order to reduce this economic burden, various methods to reduce the inrush current of induction motors are applied to suppress the additional expansion of generators due to the reduction of power generation facilities and the increase in electrical facilities. Among these methods, when a system with a built-in soft start function of an induction motor using an inverter is built, it is the best way to reduce the inrush current of the induction motor to less than the rated current. However, in this case, the installation cost of the inverter to drive the induction motor increases. This paper proposes a soft start method of an induction motor by expanding the frequency and voltage control operation area of an emergency generator. In addition, proposed a speed calculation method based on power factor information, which is essential information for stable soft start of an induction motor, and a method for generating a speed command value of the governor for starting with maximum torque.

Quantitative analysis by derivative spectrophotometry (ll) Derivative spectrophotometry and methods for the reduction of high frequency noises

  • Park, Man-Ki;Cho, Jung-Hwan
    • Archives of Pharmacal Research
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 1987
  • One of the problems of derivatie spectrophotometry, the decrease of signal-to-noise ratio by derivative operations, was solved by three concepts of digital filtering, ensemble averaging, least squares polynomial smoothing and Fourier smoothing. The suthors made several compouter programs written in APPLE SOFT BASIC language for the actual applications of the concepts of these digital filters on UV spectrophotometer system. As a result, ensemble averaging could not be used as a routine operation for the spectrophotometer used. The maximum S/N ratio enhancement factors achieved by least squares polynomial smoothing were 6.17 and 7.47 for the spectra of Gaussian and Lorentzian distribution models, and by Fourier smoothing 16.42 and 11.78 for the spectra of two models, respectively.

  • PDF

A Hybrid PWM-Resonant DC-DC Converter for Electric Vehicle Battery Charger Applications

  • Lee, Il-Oun
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1158-1167
    • /
    • 2015
  • In this paper, a new hybrid DC-DC converter is proposed for electric vehicle 3.3 kW on-board battery charger applications, which can be modulated in a phase-shift manner under a fixed frequency or frequency variation. By integrating a half-bridge (HB) LLC series resonant converter (SRC) into the conventional phase-shift full-bridge (PSFB) converter with a full-bridge rectifier, the proposed converter has many advantages such as a full soft-switching range without duty-cycle loss, zero-current-switching operation of the rectifier diodes, minimized circulating current, reduced filter inductor size, and better utilization of transformers than other hybrid dc-dc converters. The feasibility of the proposed converter has been verified by experimental results under an output voltage range of 250-420V dc at 3.3 kW.

Soft Magnetic Properties of Annealed Co-Based Amorphous Co66Fe4Ni1B15Si14 Alloy Ribbon

  • Yang, J.S.;Cho, Y.;Son, D.;Ryu, K.S.
    • Journal of Magnetics
    • /
    • v.2 no.4
    • /
    • pp.130-134
    • /
    • 1997
  • The amorphous Co-based alloy Co66Fe4Ni1B15Si14 (Metglas 2714A) is a suitable magnetic core material for high frequency operation. Appreciable reduction of the coercive force can be achieved by proper heat treatment. In this study, samples annealed at wide temperature range were analyzed using differential scanning calorimetry, high frequency B-H loop tester, X-ray diffractometer and resistivity meter. The results show that coercive force at 10 kHz decreases with in-creasing annealing temperature up to 773 K, but dramatically increases above this temperature. The squareness shows that the magnetic anisotropy on longitudinal direction of the as-cast state remains up to 773 K. Above this temperature, it decreases down to 0.5 that represents random distribution of magnetic domains. The crystallization abruptly occurs between 781 K and 783 K.

  • PDF

Resonant CLL Non-Inverting Buck-Boost Converter

  • Jabbari, Masoud;Sharifi, Saead;Shahgholian, Ghazanfar
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • This paper presents a resonant non-inverting buck-boost converter in which all switches operate under ZCS conditions. In a symmetric configuration, a CLL resonant tank along with an inverter arm and a rectifying diode are employed. The diode is turned off at ZCS and hence the problem of its reverse recovery is obviated also. As a result switching losses and EMI are reduced and switching frequency can be increased. The converter can work at DCM and CCM depend on the switching frequency and the load-current. Experimental results from a 200W/200KHz laboratory prototype verify operation of the proposed converter and the presented theoretical analysis.

Analysis of Voice and Swallowing Symptoms after Thyroidectomy in Patients without Recurrent Laryngeal Nerve Injury in Early Postoperative Period (반회후두신경 손상을 동반하지 않은 갑상선 절제술 환자에서 수술 초기의 음성 및 연하 기능의 변화에 대한 분석)

  • Kim, Heejin;Keum, Bo-Ram;Kim, Geun Hee;Jeon, Seung Sik;Kim, Hyejeen;Kim, Sung Kyun;Hong, Seok Jin;Hong, Seok-Min;Kim, Yong-Bok;Park, Il-Seok
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.27 no.2
    • /
    • pp.108-113
    • /
    • 2016
  • Background and Objectives : After thyroidectomy, many patients experience problems report such things as reduced voice range and vocal fatigue, swallowing problems without superior and recurrent laryngeal nerve injury. The purpose of this study was to evaluate voice and swallowing problems before and after thyroid surgery without laryngeal nerve injury. Materials and Methods : Ninety-three patients who underwent thyroidectomy without laryngeal nerve injury and completed the follow-up evaluations were studied between June 2013 and December 2015. Each evaluation was performed preoperatively, as well as 1 week, 1 month postoperatively. Analysis was performed including voice handicap index (VHI), dysphagia handicap index (DHI), and acoustic voice analysis. Results : Patients show significant variation of parameters in the fundamental frequency (F), maximal phonation time (MPT), shimmer, jitter and soft phonation index (SPI) early after operation, and most of them showed recovery of parameters after 1month of operation. Perceptive complaint of voice and swallowing also showed significant decreased after operation (p<0.005). After 1month of operation, MPT, highest frequency and frequency ranges still showed significant decreased parameters. Comparing acoustic and perceptive parameters of total thyroidectomy and lobectomy, there was no significant changes between them except highest frequency (p=0.042). Conclusion : The results from both subjective and objective evaluations show voice and swallowing disturbance after thyroidectomy even in the absence of laryngeal nerve and provide patients information about the recovery process after surgery. Highest frequency parameter showed most significant changes after operation.

  • PDF

Research Trend of Soft Magnetic Composite Materials with High Energy Efficiency (고에너지효율 연자성 복합 분말 소재의 연구개발 동향)

  • Kim, Hwi-Jun
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.2
    • /
    • pp.77-82
    • /
    • 2011
  • The use of soft magnetic materials have been increasing in the various industrial fields according to the increasing demand for high performance, automatic, miniaturing equipments in the recent our life. In this study, we investigated the effect of factors on the core loss and magnetic properties of electrical steel and soft magnetic composites. Furthermore, we reviewed the major efforts to reduce the core loss and improve the soft magnetic properties in the two main soft magnetic materials. Domain purification which results from reduced density of defects in cleaner electrical steels is combined with large grains to reduce hysteresis loss. The reduced thickness and the high electrical conductivity reduce the eddy current component of loss. Furthermore, the coating applied to the surface of electrical steel and texture control lead to improve high permeability and low core loss. There is an increasing interest in soft magnetic composite materials because of the demand for miniaturization of cores for power electronic applications. The SMC materials have a broad range of potential applications due to the possibility of true 3-D electromagnetic design and higher frequency operation. Grain size, sintering temperature, and the degree of porosity need to be carefully controlled in order to optimize structure-sensitive properties such as maximum permeability and low coercive force. The insulating coating on the powder particles in SMCs eliminates particle-to-particle eddy current paths hence minimizing eddy current losses, but it reduces the permeability and to a small extent the saturation magnetization. The combination of new chemical composition with optimum powder manufacturing processes will be able to result in improving the magnetic properties in soft magnetic composite materials, too.

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극 (1.0mm 및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.156-158
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is avaliable to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is avaliable Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극차이에 따른 동작출력 변화에 관한 연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.52-54
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor. Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is available to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is available. Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage. Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Design Guidelines for a Capacitive Wireless Power Transfer System with Input/Output Matching Transformers

  • Choi, Sung-Jin
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1656-1663
    • /
    • 2016
  • A capacitive wireless power transfer (C-WPT) system uses an electric field to transmit power through a physical isolation barrier which forms a pair of ac link capacitors between the metal plates. However, the physical dimension and low dielectric constant of the interface medium severely limit the effective link capacitance to a level comparable to the main switch output capacitance of the transmitting circuit, which thus narrows the soft-switching range in the light load condition. Moreover, by fundamental limit analysis, it can be proved that such a low link capacitance increases operating frequency and capacitor voltage stress in the full load condition. In order to handle these problems, this paper investigates optimal design of double matching transformer networks for C-WPT. Using mathematical analysis with fundamental harmonic approximation, a design guideline is presented to avoid unnecessarily high frequency operation, to suppress the voltage stress on the link capacitors, and to achieve wide ZVS range even with low link capacitance. Simulation and hardware implementation are performed on a 5-W prototype system equipped with a 256-pF link capacitance and a 200-pF switch output capacitance. Results show that the proposed scheme ensures zero-voltage-switching from full load to 10% load, and the switching frequency and the link capacitor voltage stress are kept below 250 kHz and 452 V, respectively, in the full load condition.