• Title/Summary/Keyword: soft clay thickness

Search Result 28, Processing Time 0.024 seconds

Clogging behavior of recycled aggregates and crushed stone as horizontal drains in soft ground (연약지반에서 수평배수재용 순환골재와 쇄석의 막힘 거동)

  • Lee, Dal-Won;Noh, Jae-Jin
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.3
    • /
    • pp.253-260
    • /
    • 2013
  • In this study, laboratory model test carried out to present the suitable range of particle size distribution and clogging behavior of recycled aggregates and crushed stone as horizontal drains in soft ground. The recycled aggregates and crushed stone showed clogging phenomenon because the top fill material and bottom clay inflow into the horizontal drains. The pp mat was the most effective method to minimize clogging phenomenon. The horizontal coefficient of permeability in case of installing the pp mat showed largely 2.1 times more than the case of not installing. When the pp mat is not installing, the thickness of fine grained soil inflow into the horizontal drains showed 6.7~13.3% range in top fill material and 3.3~6.7% range in bottom clay. Overall, the reduction of the discharge capacity by fine grained soil inflow showed small in recycled aggregates and crushed stone. Also, the appropriate criterion range of particle size distribution is presented to make use of a horizontal drains in soft ground on the basis of laboratory test.

A Study on Design Factors of Geogrid-Encased Stone Column in Soft Ground (연약지반에서 지오그리드 보강 쇄석기둥 공법의 설계 영향인자에 관한 연구)

  • Yoo, Chung-Sik;Song, Ah-Ran;Kim, Sun-Bin;Lee, Dae-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.327-334
    • /
    • 2008
  • This paper presents the results of investigation on the influencing factors for GESC(Geogrid-Encased Stone Column) method in soft ground. A parametric study was then conducted on the influencing factors such as replacement ratio, geogrid stiffness and thickness of soft ground using stress-porepressure coupled analysis. The results indicate that the relationship between these parameters and settlement ratio, and the relationship between these parameters and stress concentration factor can be identified.

  • PDF

Ultimate Uplift Capacity of Circular Anchors in Layered Soil

  • Shin, Eun-Chul;Das, Braja-M
    • Geotechnical Engineering
    • /
    • v.14 no.3
    • /
    • pp.63-72
    • /
    • 1998
  • Laboratory model test results for ultimate uplift capacity of horizontal circular anchors embedded in soft clay overlain by dense sand are presented. The effect of the critical embedment ratio on the thickness of the clay layer was evalyated. An approximate preocedure for estimating the net ultimate capacity is presented.

  • PDF

A Study on Undrained Shear Strength Characteristic of Pusan Clay (부산 점토의 비배수전단강도 특성에 관한 연구)

  • Ryu, Woongryul;Byun, Yoseph;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.3
    • /
    • pp.43-51
    • /
    • 2010
  • In the downstream areas of the Nakdong river, Pusan clays are commonly found and thickness may reach to maximum of 100m. From geological point of view, Pusan clay are characterized as holocene clays, deposited for approximately 20,000 years ago. Recently, there have been many construction projects based on these soft ground areas. It is needed to know clearly soil properties of the areas for design and safety analysis, especially undrained shear strength of soft clays. However, Pusan clay have not been studied systematically because the clay layers are usually very deep, having high sensitivity characteristic. In this study, undisturbed UD samples obtained from the downstream areas of the Nakdong river were researched using laboratory tests (CthUE, CKcUC, CIUC, UU and UC) and in-situ tests (Field Vane, CPTu). The undrained shear strength characteristics of the samples were depicted using stress-strain relationship.

A Study on Replacement Depth in Soft Soil with Inter Sand Layer (중간 모래층이 있는 연약지반내 제방하부 강제치환 깊이 산정에 관한 연구)

  • Chung, Hyung-Sik;Bang, Chang-Kug
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.4
    • /
    • pp.61-71
    • /
    • 2003
  • On the soft soil consisted of silty clay, the compulsion replacement method is useful for revetment and its safety is very much affected by compulsion replacement depth. Usual method calculating the compulsion replacement depth on silty clay is considered the bearing capacity of soft soil with undrained shear strength increase from ground surface and weight of revetment. But according to soil deposit, there are some cases of soft soil with inter sand layer or clayed silt, which affect the compulsion replacement depth. In this paper, the compulsion replacement depth on soft soil with inter sand layer is analyzed by layered weighted average bearing capacity considering influence effect of Perloff et al.(1967) and compared with numerical method(FLAC). In the result, the calculated depth from numerical method is nearest to layered weighted average bearing capacity in case that contact width under revetment is $0.2B_o$(soft soil with inter sand layer), $0.5B_o$(only soft soil) and the effect of contact width under revetment is less than undrained shear strength, thickness and location of inter sand layer. Also the compulsion replacement depth is as much as the inter sand thickness($d_2/B_o$) is thinner, the inter sand layer location($d_1/B_o$) is farther, and undrained shear strength is less.

  • PDF

Stress-strain Behavior of Hardened Barrier on Soft Soil (연약지반 위에 포설된 고화차수재의 응력-변형 특성)

  • 장연수;이종호;임학수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.607-614
    • /
    • 2000
  • Settlement with crack on the hardened liners may occur in the weak clay due to waste load since the stiffness of the hardened liner is greater than that of the clay layers. Way of reducing deformation crack in the hardened liner is investigated using two computer programs, CONSOL and FLAC. The computer program CONSOL estimates the magnitude of settlement with time in clay layers and FLAC analyses the stress and deformation relationship between the foundation of landfill and waste load. The results show that a representative block of the analyzed area reaches the consolidation settlement of 1.32m, 8.8 years after the disposal of waste started with the degree of consolidation U=90%. The stress within the hardened liner exceeds the allowable vertical stress of 5kg/$\textrm{cm}^2$ and horizontal stress of 1.67kg/$\textrm{cm}^2$ at the concave part of the liner where the main and branch drainage pipes of leachate are located. It was recognized that the thickness of the interested area should be enlarged or the strength of the same area should be improved to tolerate the planned waste load.

  • PDF

A Study on Applicability of Soil Strength for Surface Treatment (표층처리를 위한 현장의 강도적용에 관한 연구)

  • Yang, Tae-Seon;Kim, Byeong-Ho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.3
    • /
    • pp.45-52
    • /
    • 2005
  • Most marine structures are constructed on very soft soil, soil improvements are needed for the area of road, buildings. In this paper, some considerations of several case studies on soil placement method after geotextile placement, known as surface treatment, are done. Considerations of strength applicability on the advanced construction method of sand and soil placement are proposed in this paper. Typical tensile strength of geotextile used in the surface soil stabilization method is 15t/m, and thickness of sand and soil placement between 1.6m and 3.1m. Undrained shear strength of soft clay layer ranges $0.2{\sim}1.2t/m^2$. In order to minimize the difficulties which include soil disturbance, soft soil gush and overturn of vertical drain installation rig more studies are needed.

  • PDF

The Behaviour Characteristics of Strength and Deformation of the Deposited Soft Clay Owing to Contamination (퇴적 연약점토의 오염에 따른 강도 및 변형 거동특성)

  • Chun Byung-Sik;Ha Kwang-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.6
    • /
    • pp.117-126
    • /
    • 2005
  • The chemical property analysis on the deposited clay using scanning electron microscope and energy dispersive x-ray spectrometer were performed. Also, the triaxial compression tests and consolidation tests using NaCl aqueous solution and leachate as substitute pore (or saturated) water in samples were carried out to find out the behaviour characteristics of strength and deformation of contaminated deposited clay. from the chemical composition analysis results of clay samples, the magnitudes of composition ratio were revealed in the order of O, C, Si, Al, and Fe. Of these, why the ratio of carbon appeared to be large is estimated as due to the increase of the phyto-planktons after the construction of tide embankment. In the triaxial compression test and consolidation test results, the shear strength and compression properties have increased with the increase in concentration of contaminant (NaCl). This phenomenon is considered as to be caused by the changes of soil structure to flocculent structure owing to the decrease in the thickness of diffuse double layer in proportion to increase in the concentration of electrolyte.

Suggestion of the Prediction Method about Upheaval Shape and Volume for SCP Construction (SCP 시공에 따른 융기토 형상과 체적의 예측기법 제안)

  • Jeong, Gyeong-Hwan;Park, Chan-Woo;Shin, Min-Sik;Hideo-Tsuboi;Mitsuo-Nozu;Lee, Sang-Jae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.497-508
    • /
    • 2006
  • Busan-Geoje Fixed Link, total length of 8.2km, consist of bridge and immersed tunnel connects Gaduk island, Busan and Jangmokmyon, Geoje, in extension of the $58^{th}$ local road. The immersed tunnel, a total length of 3.7km within Busan-Geoje Fixed Link, was planed first timein domestic but the deep water depth like maximum of 50m with offshore conditions and the 35m thickness of soft clay layer under the immersed tunnel, migth be some problems like the differential settlement during or after works. So it was designed to install SCP(Sand Compaction Pile) column partially to improve the soft ground under the immersed tunnel. In this paper, it is presented to illustrate the design including ground condition under the immersed tunnel, improvement design, upheaval shape and ratio due to SCP test construction.

  • PDF

A Study on the Calculation of Lateral Flow Pressure of Polluted Soils with Various Water Contents (함수량이 다른 오염지반의 측방유동압 산정에 관한 연구)

  • 안종필;박경호
    • The Journal of Engineering Geology
    • /
    • v.12 no.1
    • /
    • pp.75-88
    • /
    • 2002
  • When unsymmetrical surcharge is worked on polluted soft soils, large plastic shearing deformation such as settlements, lateral displacement, upheavals and shearing failure occured in the soils and they have often done considerable damages to the soils and structures. Accordingly, this study conducts laboratory pilots test to investigate the determination method of lateral flow pressure of polluted soft soils by comparing it to existing equations. The model test is performed that a model stock device is made and polluted soils are filled in a container which fires the soils. Then the displacement is observed as surcharge load is increased by regular intervals at untrained condition. The result shows that test the lateral flow pressure is adequately calculated by the equation (P=K$_{0}$YH) and the maximum value of lateral flow pressure Is found near 0.3H of layer thickness(H) and is higher to ground surface than synthesis pattern, Poulos distribution pattern and soft clay soils(CL, CH) which is not polluted.