• Title/Summary/Keyword: sodium leakage

Search Result 56, Processing Time 0.028 seconds

A Numerical Design and Feasibility Study of Self-Wastage Experiment Using Simulant Material in a Sodium Fast Reactor

  • Jang, Sunghyon;Takata, Takashi;Yamaguchi, Akira
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.368-375
    • /
    • 2016
  • A sodiume-water reaction takes place when high-pressured water vapor leaks into sodium through a tiny defect on the surface of the heat transfer tube in a steam generator of the sodium-cooled fast reactor. The sodiume-water reaction brings deterioration of the mechanical strength of the heat transfer tube at the initial leakage site. As a result, it damages the crack itself, which may eventually enlarge into a larger opening. This self-enlargement is called "self-wastage phenomenon." In this study, a simulant experiment was proposed to reproduce the self-enlargement of a crack and to evaluate the mechanism of the self-wastage. The damage on the surface of the crack was simulated by making the neutralization reaction with hydrochloric acid solution and sodium hydroxide solution. A numerical investigation was carried out to validate the feasibility of the approach and to determine experimental conditions. From the computation results, it is observed that when 5M HCl is injected into 5M of NaOH with 0.05 m/s inlet velocity, the temperature at the surface near the crack increased over 319.26 K. The computational results show that the self-wastage phenomenon is capable of being reproduced by the simulant experiment.

The effect of MTAD as a final root canal irrigants on the coronal bacterial leakage of obturated root canals (최종 근관세척제로서의 MTAD 근관세척제가 치관부 세균미세누출에 미치는 영향)

  • Kim, Tae-Woo;Chang, Seok-Woo;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.397-404
    • /
    • 2008
  • The purpose of this study was to evaluate the effects of MTAD, EDTA and sodium hypochlorite(NaOCl) as final irrigants on coronal leakage resistance to Enterococcus faecalis. Forty extracted human maxillary molars were used in this experiment. The teeth were randomly divided into positive control group (Group 1; n = 5), negative control group (Group 2; n = 5) and three experimental groups (n = 30). In Group 3 (n = 10), the root canals were irrigated with sodium hypochlorite. In Group 4 (n = 10) and 5 (n = 10), the root canals were irrigated with sodium hypochlorite and rinsed with EDTA and MTAD, respectively. The teeth in each group were cleaned and shaped to #40 profile with .04 taper, and obturated with gutta-percha and AH-26 root canal sealer. The coronal portion of each tooth was placed in contact with inoculum of Enterococcus faecalis in Brain Heart Infusion (BHI) culture media. Each root tip was placed in a vial containing sterile culture media. The vials were placed in anaerobic chamber and observed everyday for turbidity for 180 days. Statistical analysis was performed using Fisher's Exact Test. After 180 days, Group 3, 4, and 5 showed 7, 4 and 5 leaking samples respectively. The differences in leakage resistance were not statistically significant among Group 3, 4 and 5.

Corrosion Failure Analysis of the Convection Part of District Heating Peak Load Boiler (지역난방 첨두부하보일러 대류부 부식 파손 분석)

  • Kim, Youngsu;Chae, Hobyung;Hong, Minki;Song, Min Ji;Cho, Jeongmin;Kim, Woo Cheol;Ha, Tae Baek;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.55-60
    • /
    • 2019
  • Corrosion failure in the convection part of peak load boiler (PLB) of the district heating system led to water leakage. Herein, Internal Rotary Inspection System (IRIS) inspection was employed to examine wall thinning and the cause of leakage in the flue tube. The corrosive products of the turbulator and tube were investigated using scanning electron microscope combined with energy dispersive spectroscopy, X-ray diffraction, and inductively coupled plasma (ICP). Majority of the serious corrosion damage was observed near the turbulator located in the upper flue tube. ICP analysis of the boiler water revealed oxide formation of sodium chloride in the lower end part of the flue tube. A cross-sectional view of the turbulator revealed the presence of double-layers of the oxide film, indicating environmental change during operation associated with water leakage. The outer surface of the turbulator consisted of the acid oxides such as $NO_x$ and $SO_x$ along with sodium and chloride ions. Dew-point corrosion is hypothesized as the main cause for the formation of acid oxides in the region of contact of the flue tube and the turbulator.

Effects of Extracellular Calcium and Starvation on Biochemical Indices of the Rat Hepatocytes

  • Kim, Ki-Sung
    • Toxicological Research
    • /
    • v.11 no.2
    • /
    • pp.199-203
    • /
    • 1995
  • The focus of this study was to investigate that cellular parameters and glucose uptake might be altered by extracellular calcium and starvation. Addition of 1 mM $Ca^{++}$ to hepatocytes (equalling to the free calcium concentration of blood) significantly increased intracellular $Na^+$ and decreased $Na^+$ & LDH leakage. This pertains to the hepatocytes of control rats as well as those of rats fasted for 24 and 48. hr. These effects might be come from the membrane-stabilizing effects of calcium. But calcium had no effects on cell volumes, superoxide-formation and glucose uptake. Actually hepatocytes of starved rats showed changes in several cellular parameters. Starvation increased LDH leakage, glucose uptake and the total concentration of $Na^+$ and $Na^+$ whereas it markedly decreased cell volumes. Since total tonicity remained unchanged, intracellular $Na^+$ and $Na^+$ could contribute to a higher share of total osmolarity in starvation. Starvation increased the cytoplasmic pH because $R-NH^{3+}$ions and their corresponding counterions disappeared. This increase may be related to suppress the protonization of amino groups in proteins. Starvation decreased hepatic glycogen, a major compound that affects cytosolic volume of hepatocytes. The data indicate that starvation increases the glucose transport activity. The possible molecular basis will be discussed.

  • PDF

Uranium Enrichment Reduction in the Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) with PBO Reflector

  • Kim, Chihyung;Hartanto, Donny;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.351-359
    • /
    • 2016
  • The Korean Prototype Gen-IV sodium-cooled fast reactor (PGSFR) is supposed to be loaded with a relatively-costly low-enriched U fuel, while its envisaged transuranic fuels are not available for transmutation. In this work, the U-enrichment reduction by improving the neutron economy is pursued to save the fuel cost. To improve the neutron economy of the core, a new reflector material, PbO, has been introduced to replace the conventional HT9 reflector in the current PGSFR core. Two types of PbO reflectors are considered: one is the conventional pin-type and the other one is an inverted configuration. The inverted PbO reflector design is intended to maximize the PbO volume fraction in the reflector assembly. In addition, the core radial configuration is also modified to maximize the performance of the PbO reflector. For the baseline PGSFR core with several reflector options, the U enrichment requirement has been analyzed and the fuel depletion analysis is performed to derive the equilibrium cycle parameters. The linear reactivity model is used to determine the equilibrium cycle performances of the core. Impacts of the new PbO reflectors are characterized in terms of the cycle length, neutron leakage, radial power distribution, and operational fuel cost.

Signal processing method of bubble detection in sodium flow based on inverse Fourier transform to calculate energy ratio

  • Xu, Wei;Xu, Ke-Jun;Yu, Xin-Long;Huang, Ya;Wu, Wen-Kai
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3122-3125
    • /
    • 2021
  • Electromagnetic vortex flowmeter is a new type of instrument for detecting leakage of steam generator, and the signal processing method based on the envelope to calculate energy ratio can effectively detect bubbles in sodium flow. The signal processing method is not affected by changes in the amplitude of the sensor output signal, which is caused by changes in magnetic field strength and other factors. However, the detection sensitivity of the electromagnetic vortex flowmeter is reduced. To this end, a signal processing method based on inverse Fourier transform to calculate energy ratio is proposed. According to the difference between the frequency band of the bubble noise signal and the flow signal, only the amplitude in the frequency band of the flow signal is retained in the frequency domain, and then the flow signal is obtained by the inverse Fourier transform method, thereby calculating the energy ratio. Using this method to process the experimental data, the results show that it can detect 0.1 g/s leak rate of water in the steam generator, and its performance is significantly better than that of the signal processing method based on the envelope to calculate energy ratio.

Reaction Phenomena of the Ferrite Steel by Water Leakage into Liquid Sodium (소듐분위기에서 물 누출로 인한 Ferrite Steel에서의 반응현상)

  • Jeong, Kyung-chai;Kim, Byung-ho;Kwon, Sang-woon;Kim, Kwang-rag;Hwang, Sung-tai
    • Applied Chemistry for Engineering
    • /
    • v.9 no.2
    • /
    • pp.268-272
    • /
    • 1998
  • Water leak phenomena in the liquid sodium which is a coolant of liquid metal reactor, were investigated by carrying out sodium-water reaction experiment. It was confirmed that sodium and water react each other by the analysis of material composition of aspecimen at the end of experiment. When steam of $100kg/cm^2$ was passed through the leak path of the specimen for 4 hours, reaction products from sodium-water reaction were observed on the leak site. However, re-opening phenomena were not observed at this condition. It was interpretted that the reaction product precipitated on leak path and thermal transient caused self-plugging and re-openning phenomena, respectively.

  • PDF

Plugging and Re-opening Phenomena of the 5Cr-1Mo Steel Leak Hole by Water Leakage in Sodium Atmosphere (소듐 분위기에서 물누출에 의한 5Cr-1Mo Ferrite강 구멍의 막힘과 재개방 현상)

  • Jeong, Kyung-Chai;Kim, Tae-Joon;Choi, Jong-Hyeun;Park, Jin-Ho;Hwang, Sung-Tai
    • Applied Chemistry for Engineering
    • /
    • v.9 no.5
    • /
    • pp.674-679
    • /
    • 1998
  • Small water leak experiment was carried out in liquid sodium atmosphere using a specimen of ferrite steel, which will be expected to be a material of the heat transfer tube of liquid metal fast breeder reactor. Self-plugging phenomena of leak path could be explained by the products of reaction and corrosion by sodium-water reaction. Also, re-opening mechanism of self-plugged path could be explained by the thermal transient and vibration of heat transfer tube. As a result, perfect re-opening time of self-plugged leak path was observed to be 129 minutes after water leak initiation. Re-opening shape of a specimen was appeared with double layer of circular type, and re-opening size of this specimen surface was about 2 mm diameter on sodium side.

  • PDF

Effect of Selenium on Storability of Basil (Ocimum basilicum) in Hydroponics (양액재배 시 selenium의 첨가가 basil의 저장에 미치는 영향)

  • Kim, Min-Soon;Park, Kuen-Woo
    • Horticultural Science & Technology
    • /
    • v.19 no.1
    • /
    • pp.87-91
    • /
    • 2001
  • The aim of this study was to select the proper temperature for MA storage and to study the effect of sodium selenate ($Na_2SeO_4$) on storability of hydroponically grown sweet basil. Sweet basil was cultured with 1 fold using the nutrient solution developed by European Vegetable R & D Center in Belgium. Three-weeks before harvest, sodium selenate ($Na_2SeO_4$) was treated 2, 4, 6 and $8mg{\cdot}L^{-1}$ in the nutrient solution. Although electrolyte leakage of sweet basil was remarkably increased because of chilling injury at $5^{\circ}C$ MA storage, storage life was extended for three more days by selenium supplement. The weight loss was lower at $10^{\circ}C$ than at $5^{\circ}C$ and vitamin C content was higher at $10^{\circ}C$ than $5^{\circ}C$ storage treatment. Se treatment increased vitamin C content and decreased ion leakage in the plant. Accumulation of Se in the leaves of basil was increased with Se concentration of the nutrient solution. Se accumulation was $66{\mu}g{\cdot}g^{-1}$ dry mass at $2mg{\cdot}L^{-1}$ treatment and $422{\mu}g{\cdot}g^{-1}$ dry mass at $8mg{\cdot}L^{-1}$ treatment. The results suggest that storage at $10^{\circ}C$ is good for reduction of chilling injury and maintain marketability of basil. Less than $2mg{\cdot}L^{-1}$ sodium selenate treatment is acceptable for human health.

  • PDF

THE STUDY ON THE LEAKAGE OF BLEACHING AGENTS THROUGH CERVICAL AREA ACCORDING TO THE BASING METHOD (이장재 도포 방법에 따른 표백제의 치경부 누출에 대한 연구)

  • Kim, Sung-Chul;Yoon, Tae-Chull;Park, Dong-Soo
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.250-260
    • /
    • 1995
  • Bases have been used in order to prevent the leakage of bleachingagents through dentinal tubules in bleached teeth. But the proximal surfaces where the actual resorption takes place havenot been protected. The purpose of this study was to compare the conventional basing method with the basing of the labial and two proximal surfaces to the cementoenamel junction. The bases were placed after conventional root canal treatment. Group I: 2mm thickness bases were placed to the level of labial cementoenamel junction line. Group II : 2mm thickness bases were placed to the level of all c-e J lines including cervical area. Control : No bases were placed. After placement of sodium perborate and 30% hydrogen peroxide mixtureinto the teeth, the changes of pH were measured. The results were as follows. 1. Group II showed smaller leakage of bleaching agents and was statistically significant difference compared to Group I.(p<0.05) 2. Group I showed no statistically significant difference compared to the control group. (p>0.05) 3. There were no significant among the upper and lower teeth groups in each group and between the groups.(p>0.05). According to the above results, it was considered that basing of the labial and proximal surfaces to the cementoenamel junction can reduce the leakage of bleaching agents during bleaching procedure of pulplessteeth.

  • PDF