• 제목/요약/키워드: socketed depth

검색결과 9건 처리시간 0.019초

현장타설말뚝의 암반 근입부 암판정 사례연구 (Study on Rock classification of Rock Socketed Drilled Shaft)

  • 박완서;유재현;이우철;주용선
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.658-663
    • /
    • 2010
  • Recently the most of deep foundation were socketed into weathered rock or soft rock to carry large foundation loads. The end bearing behavior of piles socketed in rock is generally dependent on the rock mass conditions with discontinuities and rock strength. Therefore, it is very important that the estimating rock classification with relation of TCR, RQD and unpredicted rock condition. In this study, the construction failure example of drilled shaft due to mistaking to estimate the rock classification on penetration were analyzed in site, so we hope to discuss problems of determining the rock socketed length of drilled shaft on construction.

  • PDF

충격반향기법에 의한 현장타설 말뚝기초의 선단 조건 평가 (Evaluation of Drilled Shaft's End Condition by Impact-Echo Method)

  • 김동수;김형우
    • 비파괴검사학회지
    • /
    • 제23권2호
    • /
    • pp.89-97
    • /
    • 2003
  • 본 논문은 탄성파를 이용한 비파괴검사 방법 중에 하나인 충격반향기법에 의하여 현장타설 말뚝기초의 선단 조건을 평가하는 연구로, 실내실험 및 현장실험을 수행하였다. 말뚝 선단 조건 평가를 위하여 직경 6cm, 길이 2m인 시멘트 모르타르 모형말뚝을 제작하였으며, 선단 조건은 자유단 조건, 고정단 조건, 암반근입 조건, 그리고 연약 선단 조건의 네 가지로 구분하였고 연약 선단 조건은 다시 말뚝과 주위 지반과의 접착 상태가 양호한 경우와 불량한 경우로 나누어 실내실험을 실시하였다. 실내실험 결과 탄성파 전파방법에 의하여 말뚝 선단 조건 가운데 자유단 조건, 고정단 조건 및 암반근입 조건을 각각 구별, 평가할 수 있었다. 또한 암반에 근입되어 있는 깊이도 정확히 산정할 수 있었으며, 말뚝과 주위 지반과의 접착상태가 불량한 경우의 연약 선단도 탐지할 수 있었다. 탄성파 전파방법의 현장 적용성을 평가하기 위하여 국내 현장에 건설되어 있는 현장타설 말뚝기초에 대하여 현장실험을 수행한 결과, 탄성파 전파방법에 의하여 현장타설 말뚝기초의 선단 조건 평가가 가능함을 확인하였다.

대구경 말뚝정재하시험 및 하중전이 측정사례 (Static pile load test and load trasfer measurement for large diameter piles.)

  • 최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 말뚝기초 학술발표회
    • /
    • pp.107-141
    • /
    • 2000
  • Large diameter piles can be defined as piles with diameter of at least 0.76 m (2.5 ft). In bridge foundation, large diameter piles have been used as pier foundations and their use has been increased greatly. In this study, static pile load tests for large diameter piles peformed in Kwangan Grande Bridge construction site were introduced. Also, various sensor installation methods for several types of piles (that is, open-ended steel pipe pile, drilled shafts and socketed pipe piles), pipe axial load measuring method, load transfer analysis method and pile load test results (pile-head load - settlement curve, and pile axial load distribution curve along the pile depth) were introduced.

  • PDF

대수심 대형 복합기초에서 설계기법에 따른 대구경 현장타설말뚝의 거동 분석 연구 (A Study on Behavior Analysis of Large-diameter Drilled Shaft by Design Methods in Deep Water Depth Composite Foundation)

  • 한유식;최용규
    • 한국지반환경공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.5-16
    • /
    • 2015
  • 장대교량의 공사비에서 대형 해상기초가 차지하는 비중은 약 40% 수준이다(KICTEP, 2007). 본 연구에서는 가상의 초장대 사장교에서 대수심 대형 복합기초에 대하여 3가지 설계법(허용응력 설계, LRFD 설계, 유로코드 설계)으로 설계검토를 실시하였고, 3차원 유한요소 해석을 통하여 대구경 현장타설말뚝의 거동에 관한 연구를 수행하였다. 그 결과, 허용응력 설계에서 추정한 방법이 연암 소켓길이가 가장 길었다. LRFD와 유로코드 설계법 2에 의해 계산된 연암소켓 길이는 유사하였다. 대구경 현장타설말뚝의 연암소켓길이가 길어짐에 따라 대구경 현장타설말뚝 두부에 작용하는 축력은 작아졌으며 현장타설말뚝의 침하량도 작아졌다.

The Performance of Large-diameter Bored Piles and Large-section Barrettes in Decomposed Geomaterials in Hong Kong

  • Ng Charles W.W.
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 추계 학술발표회
    • /
    • pp.334-408
    • /
    • 2006
  • In Hong Kong, large-diameter (${\ge}600mm$) bored piles and large-section excavated rectangular barrettes are commonly used to support tall buildings to resist both vertical and horizontal loads. These piles and barrettes penetrate through and may found in saprolitic soils and decomposed rocks. Generally, the design of these large bored piles and barrettes involves considerable amount of uncertainty and design parameters must usually be verified by field tests. In this paper, over 50 full-scale load tests on large-diameter bored piles and over 15 large-section of rectangular barrettes in Hong Kong are reviewed and interpreted critically, in particular the degree of mobilisation of side shear resistance using a mobilization rating (MR) factor and a displacement index (DI) for floating bored piles and barrettes and rock-socketed piles, respectively. The author was heavily involved with many of these load tests. The diameter of the bored piles tested ranges from 0.6m to 1.8m and the depth varies from 12m to 75m. Sizes of barrettes critically reviewed include $2.2m{\times}0.6m,\;2.2m{\times}0.8m,\;2.8m{\times}0.8m\;and\;2.8m{\times}1.0m$ (on plan) and the depth varies from 36m and 63m. Based on these field tests, a new failure load criterion for large-diameter bored piles and barrettes is developed and proposed. The side shear resistance of the bored piles and barrettes is quantitatively analyzed with respect to local displacements, standard penetration tests, unconfined compressive strength (UCS) for rock sockets and using the effective stress principle. In addition, the effects of construction including post-grouting, construction time, side scraping and excavation tools on side shear resistance are investigated and reported.

  • PDF

수치해석을 통한 암반에 근입된 현장타설말뚝의 주면부 거동특성 분석 및 설계차트 제시 (Numerical Analyses on the Behavioral Characteristics of Side of Drilled Shafts in Rocks and Suggestion of Design Charts)

  • 이혁진;김홍택
    • 대한토목학회논문집
    • /
    • 제26권6C호
    • /
    • pp.407-419
    • /
    • 2006
  • 현장타설말뚝이 주면저항력에 의해서만 지지되는 상황은 천공홀 바닥을 청소할 수 없어서 선단부 지지력의 반현 여부를 확신할 수 없을 때이다. 반대로, 신선한 기반암이 낮은 강도의 상부 재료 하부에 있는 경우는 암반에서의 선단지지력만으로 상부 하중을 지탱할 수 있으며, 상부 재료에서는 지지력 발현을 기대하지 않아도 된다. 그러나 신선암에서 일정 깊이 천공을 실시한 경우, 현장타설말뚝은 주면저항력과 선단지지력 모두를 기대할 수 있다. 암반에 근입된 현장타설말뚝의 거동에 관한 이론적 연구와 현장 시험을 통하여 작용 하중의 대부분이 통상 주면저항력에 의해서 지지되게 된다는 사실이 알려져 있다. 암-콘크리트 접촉면에서의 수직응력은 두 가지 기구에 의해 증가하게 된다. 먼저, 말뚝 상부에 작용하는 압축하중에 의해서 콘크리트는 탄성 다이레이션이 발생하고 두 번째로 거친 천공홀 표면에서 전단 변위를 통해서 접촉면의 역학적 다이레이션이 발생되게 된다. 수직 변위에 대한 근입부 주변 물질의 강성도가 일정하면, 작용하중이 증가함에 따라서 수직응력은 증가하게 되며 따라서, 전단강도의 증가 현상이 발생하게 된다. 본 연구에서는 수치해석을 통하여 암반에 근입된 현장타설말뚝의 주면부 거동특성을 조사하였다. 또한, 두부의 하중-침하량(선단부 침하량+말뚝의 탄성변형량) 관계가 비선형성을 띠는 원인 및 파괴기구를 충분히 조사함으로써 암반에 근입된 현장타설말뚝의 주면저항력에 영향을 미치는 요소들을 모두 고려하여 국내 풍화암 및 연암에 근입되는 현장타설말뚝의 설계차트를 제시하고 이를 검증하였다.

대수심 대구경 현장타설말뚝의 지지력에 대한 신뢰성 해석을 이용한 허용응력 설계의 파괴확률 평가 연구 (A Study on Estimation of Failure Probability of Allowable Stress Design using Reliability Analysis to the Bearing Capacity the Deep Water Depth Large-diameter Drilled Shaft)

  • 한유식;이윤규;최용규
    • 한국지반환경공학회 논문집
    • /
    • 제15권4호
    • /
    • pp.43-51
    • /
    • 2014
  • 시험 설계된 초장대 사장교의 고주탑을 지지하는 대수심 대형 복합기초의 지중 대구경 현장타설말뚝을 허용응력 설계법으로 설계하고, 지지력에 대한 신뢰성 해석을 통해 파괴확률을 평가하였다. 말뚝의 지지력에 대한 허용응력 설계 결과를 신뢰성 해석으로 분석하였으며 파괴확률은 CFEM의 경우 0.12 %, 한국도로공사기준 방법의 경우 0.0002 %, 구조물기초설계기준의 경우 0.003 %였다. 허용응력 설계에서는 안전율 3을 적용하여 대구경 현장타설말뚝의 허용지지력을 구하였으며, 그 결과에 대한 신뢰성 해석을 실시하였다. AASHTO(2007)에서 제시하고 있는 파괴확률($P_f$) 0.02 %일 때 CFEM 방법에서는 근입 깊이가 25 % 만큼 증가하였으며 한국도로공사기준(KHCC)에서는 근입깊이를 60 %, 구조물기초설계기준(SFDC)에서는 근입 깊이를 89 % 만큼 감소시킬 수 있었다.

암반에 근입된 현장타설말뚝의 주면부 거동특성 분석 (An Analysis on the Behavior Characteristics of the Side of Drilled Shafts in Rocks)

  • 이혁진;이형규
    • 한국지반환경공학회 논문집
    • /
    • 제7권6호
    • /
    • pp.101-111
    • /
    • 2006
  • 현장타설말뚝은 상부의 연약층을 관통하여 하부의 강한 암반층 상부에 거치시키는 경우, 말뚝은 선단지지말뚝으로 간주되며, 최소단면에서 말뚝에 발생하는 응력이나 실제 요구되는 설계기준에 따라서 작용하중은 결정된다. 연약하거나 풍화된 암반의 일정 깊이까지 현장타설말뚝을 설치하는 경우, 선단지지력과 주면저항력에 의해 지지력이 발현된다. 선단지지력 성분은 말뚝의 극한지지력에서 큰 비중을 차지한다. 그러나, 일반적으로 주면저항력은 선단지지력에 비해 훨씬 작은 말뚝 침하시 발현된다. 또한, 선단지지력은 근입부 바닥에 잔존하는 슬라임에 의해 영향을 받는다. 따라서, 근입부에 슬라임을 얼마나 잘 확인하는가와 시공법에 따라 선단지지력의 신뢰도는 결정되게 된다. 이것은 실제로 매우 어렵고 고가이며, 깊은 근입부에서는 더욱 심각하다. 따라서 이들 요소들로 인해서 작용하중하에서 말뚝의 거동은 주면저항력에 의해 지배되게 된다. 따라서 현장타설말뚝의 거동예측을 위한 연구는 주로 주면저항력 발현기구에 관심을 가지게 되는 것이다. 본 연구에서는 말뚝 두부에서의 하중 조건을 변화시켜가며 암반에 근입된 현장타설말뚝의 거동 차이를 분석하기 위하여 수치 해석을 수행하였다. 또한, 거칠기 요소의 모델링 유무에 따른 주면부 거동 특성도 조사하였다.

  • PDF

암반에 근입된 현장타설말뚝의 주면부 거동에 영향을 미치는 변수분석을 위한 수치해석 (Numerical Analyses for Evaluating Factors which Influence the Behavioral Characteristics of Side of Rock Socketed Drilled Shafts)

  • 이혁진;김홍택
    • 대한토목학회논문집
    • /
    • 제26권6C호
    • /
    • pp.395-406
    • /
    • 2006
  • 상부의 큰 하중을 지탱해야 하는 경우에는 일반적인 기초 형식으로서 현장타설말뚝공법이 많이 사용된다. 이러한 현장타설말뚝의 시공은 연약한 토사 지반을 관통하여 암반까지 굴착을 실시하는 것이 일반적이며, 지지력의 대부분은 암반층 근입부에서 발휘되게 된다. 현장타설말뚝의 지지력은 선단지지력과 주면저항력의 조합으로 이루어지게 되며, 과도한 침하가 발생하지 않고 지지력을 얻기 위해서는 근입부의 직경과 길이가 충분하여야 한다. 말뚝의 극한지지력에 있어서 선단지지력은 큰 비중을 차지한다. 그러나, 일반적으로 주면저항력은 선단지지력에 비해서 훨씬 작은 두부 침하량에서 발현된다. 또한 선단부 거동특성은 천공과정에서 발생하는 근입부 바닥에서의 잔류물에 의해서 영향을 받게 된다. 그러나 이러한 잔류물을 근입부에 잔류시키지 않기 위해서는 시공과 검사가 제대로 이루어져야 한다. 이것은 매우 어려우며 비경제적이다. 특히 암반층 근입부가 깊은 경우에는 물이나 천공 슬러리를 사용하여야 하므로 더욱 어렵다. 이러한 이유들로 인해서 작용 하중하에서 말뚝의 거동은 주면부 거동특성에 따라 좌우되게 된다. 따라서 복잡한 발현기구를 가진 주면저항력에 대해서 주로 관심을 가지게 되는 것이다. 본 연구에서는 주면저항력에 관해서만 연구를 하였다. 콘크리트 말뚝체와 주변 암반 사이의 상호작용은 말뚝 거동특성에 있어서 가장 중요한 요소이며, 시공방법에 따라서 큰 영향을 받는다. 본 연구에서는, 탄소성 해석(FLAC 2D)을 통하여 근입부의 거칠기 경사, 높이와 같은 거칠기 특성, 근입부를 형성하는 주변 암반의 강도 특성과 변형 특성, 근입부의 깊이와 길이 등이 최대단위주면저항력에 미치는 영향에 대한 검토를 실시하였다. 변수 연구를 통하여 최대단위주면저항력에 있어서는 근입부의 연직응력, 거칠기 높이와 근입부 암반의 점착력 및 포아슨비가 중요한 요소임을 확인하였다.