• Title/Summary/Keyword: smoldering

Search Result 35, Processing Time 0.024 seconds

A Study on the Characteristics of Smouldering Fire by Cigarette Fires (담뱃불에 의한 훈소화재 특성에 관한 연구)

  • Hwang, T.Y.;Lee, C.W.;Choi, D.M.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.111-126
    • /
    • 2007
  • In this study, we drew identification techniques of cigarette fires through the cases analyses of the combustion characteristics, the combustion time, the combustion temperature, the combustion test of smoldering materials and the reappearance experiments of cigarette fires. To initiate fires by cigarette fire, the conditions of oxygen supply, combustible materials must be satisfied. On the other hand, fires were not spreaded easily under the insufficient combustion conditions.

  • PDF

A Study on Combusiton Properties of Natural Fiber Dust (천연섬유분진의 연소특성에 관한 연구)

  • 이창우;김정환;현성호
    • Fire Science and Engineering
    • /
    • v.13 no.1
    • /
    • pp.3-10
    • /
    • 1999
  • We had investigated combustion properties of natural textile dusts. Decomposition properles of natural textile dusts scavenged by precipitator of spinning factoη were investigated using D DSC(Differential Scanning Calorimeter) and TGA(Thermogravimetric Analysis) by temperature c changes. Combustion pro야rties of natural textile according to size distribution and amount were c checked as temperature variation according to time using spontan$\infty$us ignition apparatus. M Moreover, combustion properties with blowing or without blowing condition were checked in order to investigate combustion prope$\pi$ies in spontaneous ignition apparatus according to flow c condition of air. As results of thermal analyses, increase in r머sing tern야:rature causes initial smold벼ng t temperature to move towards low temperature section 뻐d i띠디떠 smoldering temperature was d de$\sigma$eased more remarkably in atmosphere than in inert gas and that condition allowed heating v value to increase considerably. In addition, as amount and size distribution of natural textile d dusts were increased, i띠ti머 smoldering temperature was lowered. All of combustion forms were s smoldering combustion. Initial smold밍ing temperature was low more slightly with blowing c condition than without blowing condition in sp$\alpha$ltaneoUS ignition apparatus, which condition m made heatim;!; value high.

  • PDF

A Study on Response Characteristics of ionization Smoke Detector Influenced by Air Stream (이온화식 연기감지기의 기류응답특성 연구)

  • 이복영;정길순;이병곤
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.6-9
    • /
    • 2003
  • Recently, forced ventilating air conditioning system has been widely used in modern buildings. However, It is obvious that this kind of system may affect on the response of fire detectors at real fire incidents, especially, on the ionization smoke detector, which is critically influenced by air stream. Therefore we studied to verify the response characteristics of air stream by ionization smoke detector for the design of facilities in practice. In this study, experiments were executed to examine the correlation between air velocity and the ionization detector's responses with var-ious air velocity and smoke densities in the simulated test room. As a result of experiments, ionization detector's operating time is in reverse proportion to air velocity. And the detector shows more sensitive reaction when the velocity of smoke stream increase over 60 cm/s. In addition, it was shown that ionization smoke detector is more sensitive to smoldering fires in paper than that in petro-chemicals.

Smoldering multiple myeloma which was claimed for multiple myeloma : a case report of medical claims review (다발골수종으로 청구한 무증상다발골수종 클레임의료자문 증례)

  • Lee, Sin-Hyung
    • The Journal of the Korean life insurance medical association
    • /
    • v.29 no.2
    • /
    • pp.33-35
    • /
    • 2010
  • Multiple myeloma is characterized by the neoplastic proliferation of a single clone of plasma cells producing a monoclonal immunoglobulin and it is frequently associated with primary amyloidosis. I experienced a medical claims review case of plasma cell dyscrasia with primary amyloidosis. This medical consulting work to insurance claims will be helpful for another similar claims administration.

  • PDF

A Study on Noxious Gases Analysis of Polyurethane foams (Polyurethane foam의 유해가스 분석에 관한 연구)

  • 이창우;김정환;현성호
    • Fire Science and Engineering
    • /
    • v.14 no.2
    • /
    • pp.7-13
    • /
    • 2000
  • We had investigated thermal stability, Ignition temperature and fire gas for polyurethane foams used for manikin, cushion and interior finishing material. Decomposition of polyurethane foams with temperature was investigated using a DSC and the weight loss with temperature increase using a TGA in order to find the thermal hazard of polyurethane foams, and the ignition temperature of polyurethane foams according to species. We studied constant temperature among ignition temperature measuring methods. In addition, noxious gases for polyurethane foams according to combustion condition were analyzed using gas analyzer and GASTEC. As results, initial decomposition temperature of polyurethane foam used for interior finishing material was lower than those for manikin and cushion, and exothermic energy was higher. Ignition temperature of polyurethane foam of interior finishing material was $420^{\circ}$. All of combustion forms at $427^{\circ}$ and under were smoldering combustion, and it was combustion at $500^{\circ}$. As furnace temperature was increased, concentration of noxious gases such as carbon oxide, carbon dioxide, and hydrogen cyanide was increased. And nitrogen oxide at combustion condition($500^{\circ}$) was over 10 ppm.

  • PDF

An Intelligent Fire Detection Algorithm for Fire Detector

  • Hong, Sung-Ho;Choi, Moon-Su
    • International Journal of Safety
    • /
    • v.11 no.1
    • /
    • pp.6-10
    • /
    • 2012
  • This paper presents a study on the analysis for reducing the number of false alarms in fire detection system. In order to intelligent algorithm fuzzy logic is adopted in developing fire detection system to reduce false alarm. The intelligent fire detection algorithm compared and analyzed the fire and non-fire signatures measured in circuits simulating flame fire and smoldering fire. The algorithm has input variables obtained by fire experiment with K-type thermocouple and optical smoke sensor. Also triangular membership function is used for inference rules. And the antecedent part of inference rules consists of temperature and smoke density, and the consequent part consists of fire probability. A fire-experiment is conducted with paper, plastic, and n-heptane to simulate actual fire situation. The results show that the intelligent fire detection algorithm suggested in this study can more effectively discriminate signatures between fire and similar fire.

IR 불꽃화재감지기 개발

  • Gwon, O-Seung;Lee, Bok-Yeong;Park, Sang-Tae
    • Fire Protection Technology
    • /
    • s.29
    • /
    • pp.39-45
    • /
    • 2000
  • All objects emit thermal radiation and this radiation is the basis of the techniques used to detect flames. The usual phenomena occurring in the initial stage of a fire are generally invisible products of a combustion and visible smoke. Liquid or gaseous materials do not undergo a smoldering stage such fires develop very rapidly. Also, the heat generated by the initial flames is usually not sufficient to active a heat detector. In this case the most effective criterion for automatic fire detection is the flame. In fire regulation of korea, the compulsory standard provided that a flame detector shall be installed a place of the attachment hight of detector is higher than 20 m, chemical plants, hangar, refinery, etc.. The result of the research and development are discriminated between a flame and other radiant emitters, developed PZT pyroelectric element is based on the use of photo-voltanic cell, developed IR band-pass filter that only allow a 4.3 radiation wavelength to reach the sensors and developed IR flame detector.

  • PDF

SMOLDERING IGNITION OF FLAMMABLE SUBSTRATE

  • Yi, Sung-Chul;Kim, Hee-Taik;Ryu, Kyong-Ok
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.162-168
    • /
    • 1997
  • A theoretical model for the interaction of the moving heat source and a solid substrate when they are in contact is described. for purposes of the model the substrate is assumed to act as a continuum and the Fourier equation for transient. three-dimensional conduction is solved using Laplace and Fourier transformations. Unlike most previous models, this model shows the explicit relations between the properties of heat source and that of the substrate. Since the size, shape and speed of heat source impact the ignition of substrate, considerable attention is devoted to evaluating these parameters. Results are presented which show the effects of the size, shape and speed of heat source on the substrate.

  • PDF

Study on the Ignition of Fallen Leaves by a Cigarette Butt (담뱃불에 의한 낙엽 착화에 대한 연구)

  • Kim, Dong-Hyun;Lee, Myung-Bo
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.39-49
    • /
    • 2010
  • In order to find out the environment vulnerable to cigarette fire in which smoldering fire grows into flame fire, a cigarette combustion test and numerical analysis were performed using fallen leaves of P. densiflora and Q. variabilis. Tests were repeated five times on 2,304 conditions with four cases of fuel moisture content, six cases of velocity, two cases of cigaret location against direction of the wind, three cases of cigaret location against fallen leaves, two species of thickness of cigaret, two cases of slope conditions and two cases of fragileness of fallen leaves. Cigaret fire's flammability to the fallen leaves was monitored by analyzing heat transfer process using CFD (Computational Fluid Dynamic) under the most optimal condition through an ignition test on 2,304 conditions. The result of a cigaret fire ignition test for fallen leaves, found ignition in 197 conditions out of 2,304 conditions representing 8.6% while 13 conditions representing approximately 0.6% saw ignition across five repeated tests. The result of CFD analysis, the temperature of the bottom of fallen leaves was reached on self-ignition and pilot-ignition temperature.

Consideration on Fire-prevention Facilities for Wooden Cultural Heritages (목조문화재 보존을 위한 소방시설에 대한 고찰)

  • Kim, Tae-Goo
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.155-171
    • /
    • 2010
  • Wooden cultural heritages have many factors of fires and structural characteristics vulnerable to the fire extinguishing. Also, they are surrounded with forests and so remote from fire stations, which make it difficult to handle it quickly when fires break out. Wooden cultural heritages made of wood materials belong to the general fire in a Class A. Taking characteristics such as a smoldering and a backfire from the that fire of wooden materials into consideration, extinguishing the fire by the cooling system is the most effective. If the fire can't be put out at the early stage, it is almost impossible to protect wooden cultural heritages from the fire, because wooden structures can be destroyed in a high temperature and in a short time and it takes around average 7 minutes to reach its peak of flames in the process of a fire. According to the geographical and environmental situation of the cultural heritages, currently, the fire-prevention facilities such as the auto fire detector for the prompt detection, the water mist fire suppression system for the 1st early and urgent fire suppression and the outdoor fire hydrant and the water curtain etc. for the 2nd full-scale suppression and the prevention of the fire gaining force are being installed for the wooden cultural heritages.

  • PDF