• Title/Summary/Keyword: smartRF

Search Result 175, Processing Time 0.026 seconds

Development of a LonRF Intelligent Device-based Ubiquitous Home Network Testbed (LonRF 지능형 디바이스 기반의 유비쿼터스 홈네트워크 테스트베드 개발)

  • 이병복;박애순;김대식;노광현
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.6
    • /
    • pp.566-573
    • /
    • 2004
  • This paper describes the ubiquitous home network (uHome-net) testbed and LonRF intelligent devices based on LonWorks technology. These devices consist of Neuron Chip, RF transceiver, sensor, and other peripheral components. Using LonRF devices, a home control network can be simplified and most devices can be operated on LonWorks control network. Also, Indoor Positioning System (IPS) that can serve various location based services was implemented in uHome-net. Smart Badge of IPS, that is a special LonRF device, can measure the 3D location of objects in the indoor environment. In the uHome-net testbed, remote control service, cooking help service, wireless remote metering service, baby monitoring service and security & fire prevention service were realized. This research shows the vision of the ubiquitous home network that will be emerged in the near future.

Measurements of Dark Area in Sensing RFID Transponders

  • Kang, J.H.;Kim, J.Y.
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.103-108
    • /
    • 2012
  • Radiofrequency(RF) signal is a key medium to the most of the present wireless communication devices including RF identification devices(RFID) and smart sensors. However, the most critical barrier to overcome in RFID application is in the failure rate in detection. The most notable improvement in the detection was from the introduction of EPC Class1 Gen2 protocol, but the fundamental problems in the physical properties of the RF signal drew less attention. In this work, we focused on the physical properties of the RF signal in order to understand the failure rate by noting the existence of the ground planes and noise sources in the real environment. By using the mathematical computation software, Maple, we simulated the distribution of the electromagnetic field from a dipole antenna when ground planes exist. Calculations showed that the dark area can be formed by interference. We also constructed a test system to measure the failure rate in the detection of a RFID transponder. The test system was composed of a fixed RFID reader and an EPC Class1 Gen2 transponder which was attached to a scanner to sweep in the x-y plane. Labview software was used to control the x-y scanner and to acquire data. Tests in the laboratory environment showed that the dark area can be as much as 43 %. One who wants to use RFID and smart sensors should carefully consider the extent of the dark area.

Water level forecasting for extended lead times using preprocessed data with variational mode decomposition: A case study in Bangladesh

  • Shabbir Ahmed Osmani;Roya Narimani;Hoyoung Cha;Changhyun Jun;Md Asaduzzaman Sayef
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.179-179
    • /
    • 2023
  • This study suggests a new approach of water level forecasting for extended lead times using original data preprocessing with variational mode decomposition (VMD). Here, two machine learning algorithms including light gradient boosting machine (LGBM) and random forest (RF) were considered to incorporate extended lead times (i.e., 5, 10, 15, 20, 25, 30, 40, and 50 days) forecasting of water levels. At first, the original data at two water level stations (i.e., SW173 and SW269 in Bangladesh) and their decomposed data from VMD were prepared on antecedent lag times to analyze in the datasets of different lead times. Mean absolute error (MAE), root mean squared error (RMSE), and mean squared error (MSE) were used to evaluate the performance of the machine learning models in water level forecasting. As results, it represents that the errors were minimized when the decomposed datasets were considered to predict water levels, rather than the use of original data standalone. It was also noted that LGBM produced lower MAE, RMSE, and MSE values than RF, indicating better performance. For instance, at the SW173 station, LGBM outperformed RF in both decomposed and original data with MAE values of 0.511 and 1.566, compared to RF's MAE values of 0.719 and 1.644, respectively, in a 30-day lead time. The models' performance decreased with increasing lead time, as per the study findings. In summary, preprocessing original data and utilizing machine learning models with decomposed techniques have shown promising results for water level forecasting in higher lead times. It is expected that the approach of this study can assist water management authorities in taking precautionary measures based on forecasted water levels, which is crucial for sustainable water resource utilization.

  • PDF

A RF Energy Harvesting Based Routing Protocol in Mobile Ad-hoc Wireless Sensor Networks (모바일 애드혹 무선 센서 네트워크에서 RF 에너지 하베스팅 기반 라우팅 프로토콜)

  • Shim, KyuHyun;An, Beongku
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.4
    • /
    • pp.87-93
    • /
    • 2016
  • In this paper, we propose a RF energy harvesting based routing protocol in mobile ad-hoc wireless sensor networks. The main features and contributions of the proposed routing protocol are as follows. First, establishment of routing route based on both remaining energy of mobile sensor nodes and RF energy harvesting. Second, establishment of routing route by considering availability and stability of route based on energy of mobile sensor nodes to increase lifetime of networks and route. The performance evaluation of the proposed routing protocol using OPNET shows that the routing method considering both route availability and route stability based on RF energy harvesting can increase efficiently route lifetime.

Analysis of Indoor Localization Technology for Exhibition Services and Application Method of VLC/RF Converged Localization (전시 서비스를 위한 실내 측위 기술 분석 및 VLC/RF 결합 측위 적용 방안)

  • Kim, Ki-Yun;Lee, Min-Woo;Cha, Jae-Sang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.1
    • /
    • pp.217-225
    • /
    • 2015
  • Recently, as the supply of smart phone is spreading and the exhibition industries are rapidly growing, future exhibitions are evolving toward active, customized, interactive, tangible services, which can give more satisfaction to visitors. To realize this services, the indoor localization in the exhibition of visitors is very important and according to the accuracy of localization the quality of services for exhibition are also different. In this paper, state-of-the art indoor localization techniques are investigated and new localization method are proposed. To achieve this goal, future exhibition service types are proposed, which are connected with IT technology. And also, BLE(Bluetooth Low Energy) technology including comparison of specifications and representative localization technologies are analysed. Furthermore we performed comparison study and simulation between RF and VLC channels. Finally based on this, we proposed converged VLC and RF(Wi-Fi and BLE) localization technique for exhibition.

Clothing Management System Using the Smart Hanger Embedded RFID (RFID가 내장된 스마트 옷걸이를 이용한 의류 관리 시스템)

  • Chung, Sung Boo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.8
    • /
    • pp.185-194
    • /
    • 2014
  • In this paper, we proposed the clothing management system using the smart hanger. Proposed system consists of smart hanger, base module, and server, and the smart hanger consists of MCU, LED, RFID reader, RF chip, ring sensor, and battery. The smart hanger reads the RFID tag attached to the clothes and wirelessly transmitted to the server. The server associated base module communicates with the smart hanger and transmits information to the server. The server manages clothing through the DB, and can display various information through the web page and the smart phone. In order to verify the usefulness of the proposed system, we did experiment with the management system for clothing store and laundry where using a lot of hangers. Performance tests of the smart hanger are applied to check the current consumption and can be predicted the battery life with the proposed low power algorithm. The clothing store management system can be increased sales and convenience of the consumer. The laundry management system can be increased the efficiency of laundry category and convenience of the consumer.

Highly Elastic Two-wire Transmission Line E-textile Band for Smart Wearable Circuit Formation (스마트 웨어러블 회로 구성을 위한 고신축성 이선 전송선형 전자섬유 밴드)

  • Roh, Jung-Sim
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.2
    • /
    • pp.367-374
    • /
    • 2022
  • Herein, a highly elastic e-textile band with a two-wire transmission line was designed and fabricated for smart clothing applications. A conductive yarn with a very uniform low electrical resistance of 0.0357 Ω/cm was developed and used for the signal and ground lines. To control the elasticity of the e-textile band, spandex yarns were added in the warp direction during knitting and the tension was adjusted. As the length of the e-textile band increased, its RF performance deteriorated. Furthermore, the frequency corresponding to -3 dB S21 was lower in the 30% stretched band than in the unstretched band. For the e-textile bands with lengths 10, 50, and 100 cm, the frequencies corresponding to -3 dB S21 were 107.77, 24.56, and 13.02 MHz when not stretched, and 88.74, 22.02, and 12.60 MHz when stretched by 30%. The fabricated bands were flatter, more flexible, and more elastic than transmission line cables; thus, they can be easily integrated into wearables and smart clothing. However, to increase RF performance and achieve optimum utilization, future studies must focus on the fabrication of transmission lines with lower resistance and reduced distance between the signal and ground lines, and thus the number of transmission lines can be increased.

High Performance RF Passive Integration on a Si Smart Substrate for Wireless Applications

  • Kim, Dong-Wook;Jeong, In-Ho;Lee, Jung-Soo;Kwon, Young-Se
    • ETRI Journal
    • /
    • v.25 no.2
    • /
    • pp.65-72
    • /
    • 2003
  • To achieve cost and size reductions, we developed a low cost manufacturing technology for RF substrates and a high performance passive process technology for RF integrated passive devices (IPDs). The fabricated substrate is a conventional 6" Si wafer with a 25${\mu}m$ thick $SiO_2$ surface. This substrate showed a very good insertion loss of 0.03 dB/mm at 4 GHz, including the conductive metal loss, with a 50 ${\Omega}$ coplanar transmission line (W=50${\mu}m$, G=20${\mu}m$). Using benzo cyclo butene (BCB) interlayers and a 10 ${\mu}m$ Cu plating process, we made high Q rectangular and circular spiral inductors on Si that had record maximum quality factors of more than 100. The fabricated inductor library showed a maximum quality factor range of 30-120, depending on geometrical parameters and inductance values of 0.35-35 nH. We also fabricated small RF IPDs on a thick oxide Si substrate for use in handheld phone applications, such as antenna switch modules or front end modules, and high-speed wireless LAN applications. The chip sizes of the wafer-level-packaged RF IPDs and wire-bondable RF IPDs were 1.0-1.5$mm^2$ and 0.8-1.0$mm^2$, respectively. They showed very good insertion loss and RF performances. These substrate and passive process technologies will be widely utilized in hand-held RF modules and systems requiring low cost solutions and strict volumetric efficiencies.

  • PDF

A 0.18-um CMOS 920 MHz RF Front-End for the IEEE 802.15.4g SUN Systems (IEEE 802.15.4g SUN 표준을 지원하는 920 MHz 대역 0.18-um CMOS RF 송수신단 통합 회로단 설계)

  • Park, Min-Kyung;Kim, Jong-Myeong;Lee, Kyoung-Wook;Kim, Chang-Wan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.423-424
    • /
    • 2011
  • This paper has proposed a 920 MHz RF front-end for IEEE 802.15.4g SUN (Smart Utility Network) systems. The proposed 920 MHz RF front-end consists of a driver amplifier, a low noise amplifier, and a RF switch. In the TX mode, the driver amplifier has been designed as a single-ended topology to remove a transformer which causes a loss of the output power from the driver amplifier. In addition, a RF switch is located in the RX path not the TX path. In the RX mode, the proposed low noise amplifier can provide a differential output signal when a single-ended input signal has been applied to. A LC resonant circuit is used as both a load of the drive amplifier and a input matching circuit of the low noise amplifier, reducing the chip area. The proposed 920 MHz RF Front-end has been implemented in a 0.18-um CMOS technology. It consumes 3.6 mA in driver amplifier and 3.1 mA in low noise amplifier from a 1.8 V supply voltage.

  • PDF