• Title/Summary/Keyword: small-signal analysis

Search Result 593, Processing Time 0.026 seconds

Expression of Phospholipase C Isozymes in Human Lung Cancer Tissues (인체 폐암조직에서 Phospholipase C 동위효소의 발현양상)

  • Hwang, Sung-Chul;Mah, Kyung-Ae;Choi, So-Yeon;Oh, Yoon-Jung;Choi, Young-In;Kim, Deog-Ki;Lee, Hyung-Noh;Choi, Young-Hwa;Park, Kwang-Ju;Lee, Yi-Hyeong;Lee, Kyi-Beom;Ha, Mahn-Joon;Bae, Yoon-Su
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.3
    • /
    • pp.310-322
    • /
    • 2000
  • Background : Phospholipase C(PLC) plays an important role in cellular signal transduction and is thought to be critical in cellular growth, differentiation and transformation of certain malignancies. Two second messengers produced from the enzymatic action of PLC are diacylglycerol (DAG) and inositol 1, 4, 5-trisphosphate (IP3). These two second messengers are important in down stream signal activation of protein kinase C and intracellular calcium elevation. In addition, functional domains of the PLC isozymes, such as Src homology 2 (SH2) domain, Src homology 3 (SH3) domain, and pleckstrin homology (PH) domain play crucial roles in protein translocation, lipid membrane modificailon and intracellular memrane trafficking which occur during various mitogenic processes. We have previously reported the presence of PLC-${\gamma}1$, ${\gamma}2$, ${\beta}1$, ${\beta}3$, and ${\delta}1$ isozymes in normal human lung tissue and tyrosine-kinase-independent activation of phospholipase C-${\gamma}$ isozymes by tau protein and AHNAK. We had also found that the expression of AHNAK protein was markedly increased in various mstologic types of lung can∞r tissues as compared to the normallungs. However, the report concerning expression of various PLC isozymes in lung canærs and other lung diseases is lacking. Therefore, in this study we examined the expression of PLC isozymes in the paired surgical specimens taken from lung cancer patients. Methods : Surgically resected lung cancer tissue samples taken from thirty seven patients and their paired normal control lungs from the same patients, The expression of various PLC isozymes were studied. Western blot analysis of the tissue extracts for the PLC isozymes and immunohistochemistry was performed on typical samples for localization of the isozyme. Results : In 16 of 18 squamous cell carcinomas, the expression of PLC-${\gamma}1$ was increased. PLC-${\gamma}1$ was also found to be increased in all of 15 adenocarcinoma patients. In most of the non-small cell lung cancer tissues we had examined, expression of PLC-${\delta}1$ was decreased. However, the expression of PLC-${\delta}1$ was markedly increased in 3 adenocarcinomas and 3 squamous carcinomas. Although the numbers were small, in all 4 cases of small cell lung cancer tissues, the expression of PLC-${\delta}1$ was nearly absent. Conclusion : We found increased expression of PLC-${\gamma}1$ isozyme in lung cancer tissues. Results of this study, taken together with our earlier findings of AHNAK protein-a putative PLD-${\gamma}$, activator-over-expression, and the changes observed in PLC-${\delta}1$ in primary human lung cancers may provide a possible insight into the derranged calcium-inositol signaling pathways leading to the lung malignancies.

  • PDF

Design and fabrication of a 300A class general-purpose current sensor (300A급 일반 산업용 전류센서의 설계 및 제작)

  • Park, Ju-Gyeong;Cha, Guee-Soo;Ku, Myung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.1-8
    • /
    • 2016
  • Current sensors are used widely in the fields of current control, monitoring, and measuring. They have become more popular with the increasing demand for smart grids in a power network, generation of renewable energy, electric cars, and hybrid cars. Although open loop Hall effect current sensors have merits, such as low cost, small size, and weight, they have low accuracy. This paper describes the design and fabrication of a 300A open loop current sensor that has high accuracy and temperature performance. The core of the current sensor was calculated numerically and the signal conditioning circuits were designed using circuit analysis software. The characteristics of the manufactured open loop current sensor of 300 A class was measured at currents up to 300 A. According to the test of the current sensor, the accuracy error and linearity error were 0.75% and 0.19%, respectively. When the temperature compensation was carried out with the relevant circuit, the temperature coefficients were less than $0.012%/^{\circ}C$ at temperatures between $-25^{\circ}C$ and $85^{\circ}C$.

The Effect of PDGF-Loaded Biodegradable Membrane on Early Healing Stage in Guided Tissue Regeneration (흡수성 차폐막의 치주조직 재생에 혈소판유래 성장인자가 미치는 영향)

  • Rhyu, In-Chul;Bae, Kyoo-Hyun;Seol, Yang-Jo;Ku, Young;Lee, Seung-Jin;Han, Soo-Boo;Choi, Sang-Mook;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.507-519
    • /
    • 1999
  • The ultimate objective of periodontal treatment is to stop disease progression and to regenerate destroyed periodontal tissues and thereby regain normal function. Growth factors are naturally found polypetides which stimulate many cellular activities pertaining to wound healing by acting as signal molecule in controlling cell movement, proliferation, and matrix production. Platelet derived growth factor (PDGF) is 28,000-35,000 Da molecular weight dimeric protein with 2 long positively charged polypeptide chains connected by sulfide bonds. The purpose of this study is to evaluate histologically the initial guided tissue regeneration in a periodontal defect f a beagle dog treated with a biodegradable membrane formed with polylactic acid (poly-L-lactic acid) and polyglycolic acid loaded with 200ng/$cm^2$ platelet derived growth factor. 2 beagle dogs were used in he experiment. $5mm{\times}6mm$ alveolar bone defect was formed in upper and lower canines and third premolars and a reference notch was placed. PDGF-BB non-containing membrane was used as control. Each defect was randomly assigned to the test roup or the control group. The dogs were sacrificed 3 weeks after membrane placement. Toluidine blue and multiple staining was done for histological analysis. In the 3 week specimen in the control group, no new one formation could be seen. Small amount f bone resorption below the notch could be seen. In the notch, loose connective tissue with infiltration of inflammatory cells could be seen. Also thin discontinuous new cementum could be seen and the membrane still retained its structure. Where PDGF-BB containing membrane was used, new bone formation could be seen in the notch at weeks and also continuous thin cementum could be seen. PDL cells were observed between new bone and new cementum and some were attached to bone and cementum. These results suggest that new bone and cementum formation seen when PDGF-BB loaded membrane was used was due to inhibition of downgrowth of epithelial cells and also due to continuous release of the growth factor. Further study on the resorption characteristics of the membrane nd the release characteristics of the PDGF-BB is necessary. Also, development of a membrane easier to use clinically is necessary.

  • PDF

Spine Computed Tomography to Magnetic Resonance Image Synthesis Using Generative Adversarial Networks : A Preliminary Study

  • Lee, Jung Hwan;Han, In Ho;Kim, Dong Hwan;Yu, Seunghan;Lee, In Sook;Song, You Seon;Joo, Seongsu;Jin, Cheng-Bin;Kim, Hakil
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.3
    • /
    • pp.386-396
    • /
    • 2020
  • Objective : To generate synthetic spine magnetic resonance (MR) images from spine computed tomography (CT) using generative adversarial networks (GANs), as well as to determine the similarities between synthesized and real MR images. Methods : GANs were trained to transform spine CT image slices into spine magnetic resonance T2 weighted (MRT2) axial image slices by combining adversarial loss and voxel-wise loss. Experiments were performed using 280 pairs of lumbar spine CT scans and MRT2 images. The MRT2 images were then synthesized from 15 other spine CT scans. To evaluate whether the synthetic MR images were realistic, two radiologists, two spine surgeons, and two residents blindly classified the real and synthetic MRT2 images. Two experienced radiologists then evaluated the similarities between subdivisions of the real and synthetic MRT2 images. Quantitative analysis of the synthetic MRT2 images was performed using the mean absolute error (MAE) and peak signal-to-noise ratio (PSNR). Results : The mean overall similarity of the synthetic MRT2 images evaluated by radiologists was 80.2%. In the blind classification of the real MRT2 images, the failure rate ranged from 0% to 40%. The MAE value of each image ranged from 13.75 to 34.24 pixels (mean, 21.19 pixels), and the PSNR of each image ranged from 61.96 to 68.16 dB (mean, 64.92 dB). Conclusion : This was the first study to apply GANs to synthesize spine MR images from CT images. Despite the small dataset of 280 pairs, the synthetic MR images were relatively well implemented. Synthesis of medical images using GANs is a new paradigm of artificial intelligence application in medical imaging. We expect that synthesis of MR images from spine CT images using GANs will improve the diagnostic usefulness of CT. To better inform the clinical applications of this technique, further studies are needed involving a large dataset, a variety of pathologies, and other MR sequence of the lumbar spine.

Verification of the Planetary Boundary Layer Height Calculated from the Numerical Model Using a Vehicle-Mounted Lidar System (차량탑재 라이다 시스템을 활용한 수치모델 행성경계층고도 검증)

  • Park, Chang-Geun;Nam, Hyoung-Gu
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.793-806
    • /
    • 2020
  • In this study,for YSU (Yonsei University), MYJ(Mellor-Yamada-Janjic), ACM2 (Asymmetric Convective Model), and BouLac (Bougeault-Lacarrere) PBL schemes, numerical experiments were performed for the case period (June 26-30, 2014). The PBLH calculated by using the backscatter signal produced by the mobile vehicle-mounted lidar system (LIVE) and the PBLH calculated by the prediction of each PBL schemes of WRF were compared and analyzed. In general, the experiments using the non-local schemes showed a higher correlation than the local schemes for lidar observation. The standard deviation of the PBLH difference for daylight hours was small in the order of YSU (≈0.39 km), BouLac (≈0.45 km), ACM2 (≈0.47 km), MYJ (≈0.53 km) PBL schemes. In the RMSE comparison for the case period, the YSU PBL scheme was found to have the highest precision. The meteorological lider mounted on the vehicle is expected to provide guidance for the analysis of the planetary boundary layer in a numerical model under various weather conditions.

Development of Gravity Gradient Referenced Navigation and its Horizontal Accuracy Analysis (중력구배기반 항법 구현 및 수평위치 정확도 분석)

  • Lee, Jisun;Kwon, Jay Hyoun;Yu, Myeongjong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.1
    • /
    • pp.63-73
    • /
    • 2014
  • Recently, researches on DBRN(DataBase Referenced Navigation) system are being carried out to replace GNSS(Global Navigation Satellite System), as weaknesses of GNSS were found that are caused by the intentional interference and the jamming of the satellite signal. This paper describes the gravity gradient modeling and the construction of EKF(Extended Kalman Filter) based GGRN(Gravity Gradient Referenced Navigation). To analyze the performance of GGRN, fourteen flight trajectories were made for simulations over whole South Korea. During the simulations, we considered the errors in both DB(DataBase) and sensor as well as the flight altitudes. Accurate performances were found, when errors in the DB and the sensor are small and they located at lower altitude. For comparative evaluation, the traditional TRN(Terrain Referenced Navigation) was also developed and performances were analyzed relative to those from the GGRN. In fact, most of GGRN performed better in low altitude, but both of precise gravity gradient DB and gradiometer were required to obtain similar level of precisions at the high altitude. In the future, additional tests and evaluations on the GGRN need to be performed to investigate on more factors such as DB resolution, flight speed, and the update rate.

Design of a SQUID Sensor Array Measuring the Tangential Field Components in Magnetocardiogram (심자도용 접선성분자장 측정방식 스퀴드 센서열 설계)

  • Kim K.;Lee Y. H;Kwon H;Kim J. M;Kim I. S;Park Y. K;Lee K. W
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.56-63
    • /
    • 2004
  • We consider design factors for a SQUID sensor array to construct a 52-channel magnetocardiogram (MCG) system that can be used to measure tangential components of the cardiac magnetic fields. Nowadays, full-size multichannel MCG systems, which cover the whole signal area of a heart, are developed to improve the clinical analysis with high accuracy and to provide patients with comfort in the course of measurement. To design the full-size MCG system, we have to make a compromise between cost and performance. The cost is involved with the number of sensors, the number of the electronics, the size of a cooling dewar, the consumption of refrigerants for maintenance, and etc. The performance is the capability of covering the whole heart volume at once and of localizing current sources with a small error. In this study, we design the cost-effective arrangement of sensors for MCG by considering an adequate sensor interval and the confidence region of a tolerable localization error, which covers the heart. In order to fit the detector array on the cylindrical dewar economically, we removed the detectors that were located at the corners of the array square. Through simulations using the confidence region method, we verified that our design of the detector array was good enough to obtain whole information from the heart at a time. A result of the simulation also suggested that tangential-component MCG measurement could localize deeper current dipoles than normal-component MCG measurement with the same confidence volume; therefore, we conclude that measurement of the tangential component is more suitable to an MCG system than measurement of the normal component.

  • PDF

The efficiency Analysis of study using brainwave measurement device (Biopac 뇌파측정 장치를 이용한 학습의 효율성 분석)

  • An, Young-Jun;Lee, Chung-Heon;Park, Mun-Kyu;Ji, Hoon;Lee, Dong-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.951-953
    • /
    • 2015
  • Learning for thinking says the behavior of the organism changes as a result of practice or experience. It is very difficult to identify focusing ability objectively when students study. But, brain of the body is not so. EEG signal means continuously electric records of brain potential variation between two points on the scalp when brain activities take place. In types of EEG, there are delta(0~4Hz), theta(4~8Hz), alpha(8~13Hz), beta(13~30Hz) and gamma waves(30~50Hz). SMR waves and Mid-beta waves appear when focused for studying. Part for the most influence on concentrating reported that Mid-beta waves. In relation to brain activities, EEG has been actively researched for evaluating brain focus index system during learning and study. So, By using Biopac system for this study, measured brain wave was converted into FFT for extracting Mid-beta domain signals that are related to learning after giving focus invoked subjects to a small number of people. When concentrating, we measured the change in the power of the Mid-beta frequency domain and presented a correlation. Based on these results, we analyzed whether students are concentrated objectively on learning or not. and hope to offer more efficient learning method.

  • PDF

Inhibition of SKTI Synthesis in Agrobacterium rhizogenes-induced Hairy Root Reduces the Number of Nodule in Soybean (Kunitz Trypsin Inhibitor 발현 억제에 의한 콩 뿌리혹 수의 감소)

  • Kim, Sun-Hyung;Lim, Chae-Woo;Park, Ji-Young;Hwang, Cheol-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.54 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • In nitrogen-limited conditions, rhizobia lead to formation of nitrogen-fixing nodules on the roots of leguminous plants. The process of nodulation is autoregulated by pre-existing nodules in the same root system. The altered profile of sap proteins by inoculation with B. japonicum may indicate presence of a signal responsible for autoregulation transferred through stem. The 20 kDa protein enhanced by innoculation significantly decreased in intensity from 2.5 to 7 days after inoculation (DAI). However 6 kDa protein did increase during such a transition period. Western blot analysis showed that both 20 kDa and 6 kDa were cross-reacted with the SKTI antiserum. This suggests that SKTI may be involved in soybean nodulation by specific induction and degradation in stem sap during early stage of nodulation. RNAi technique and Agrobacterium rhizogenes-mediated transformation were applied to investigate the function of SKTI in nodulation. We have found that the number of rhizobium-induced nodule was much less in SKTIi-silenced hairy roots than the non-silenced. Indeed the quantitative RT-PCR showed that the expression level of SKTI gene was reduced over 40% in the transgenic hairy roots compared to the non-transgenic. It appears that the observed early induction of SKTI and degradation into small peptide in a specific time manner may be involved in autoregulation of nodulation in soybean and the specific mechanism of such regulation remains to be investigated.

Effects of Chromium on Energy Metabolism in Lambs Fed with Different Dietary Protein Levels

  • Yan, Xiaogang;Zhang, Fangyu;Li, Dong;Zhu, Xiaoping;Jia, Zhihai
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.2
    • /
    • pp.205-212
    • /
    • 2010
  • The effects of chromium (Cr), dietary crude protein (CP) level, and potential interactions of these two factors were investigated in term of energy metabolism in lambs. Forty-eight 9-week-old weaned lambs (Dorper${\times}$Small-tail Han sheep, male, mean initial body weight = 22.96 kg${\pm}$2.60 kg) were used in a 2${\times}$3 factorial arrangement of supplemental Cr (0 ${\mu}g$/kg, 400 $\mu{g}$/kg or 800 ${\mu}g$/kg from chromium yeast) and protein levels (low protein: 157 g/d to 171 g/d for each animal, or high protein: 189 g/d to 209 g/d for each animal). Blood samples were collected at the beginning and end of the feeding trial. The lambs were then sacrificed and tissue samples were frozen for further analysis. Chromium at 400 ${\mu}g$/kg decreased fasting insulin level and the ratio of plasma insulin to glucagon, but these differences were not statistically significant; in contrast, chromium at 800 ${\mu}g$/kg increased the ratio significantly (p<0.05). Protein at the high level increased plasma tumor necrosis factor $\alpha$ (TNF-$\alpha$) level (p = 0.060). Liver glycogen content was increased significantly by Cr (p<0.05), which also increased liver glucose-6-phosphatase (G-6-Pase) and adipose hormone-sensitive lipase (HSL) activity. At 400 ${\mu}g$/kg, Cr increased muscle hexokinase (HK) activity. High protein significantly increased G-6-Pase activities in both the liver (p<0.05) and the kidney (p<0.05), but significantly decreased fatty acid synthase (FAS) activity in subcutaneous adipose tissue (p<0.05). For HSL activity in adipose tissue, a Cr${\times}$CP interaction (p<0.05) was observed. Overall, Cr improved energy metabolism, primarily by promoting the glycolytic rate and lipolytic processes, and these regulations were implemented mainly through the modulation by Cr of the insulin signal transduction system. High protein improved gluconeogenesis in both liver and kidney. The interaction of Cr${\times}$CP indicated that 400 $\mu{g}$/kg Cr could reduce energy consumption in situations where energy was being conserved, but could improve energy utilization when metabolic rate was increased.